From 73247f1ced303c16987bb366d38a2d8a0fc40db4 Mon Sep 17 00:00:00 2001 From: Xiaolong Ye Date: Thu, 15 Nov 2018 15:20:05 +0800 Subject: [PATCH] net/ixgbe: fix maximum wait time in comment As the code has changed the max wait time to 1000ms, the comment should be changed accordingly. Fixes: 64f1c8539c8c ("net/ixgbe: wait longer for link after fiber MAC setup") Cc: stable@dpdk.org Signed-off-by: Xiaolong Ye Acked-by: Qi Zhang --- drivers/net/ixgbe/base/ixgbe_common.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/net/ixgbe/base/ixgbe_common.c b/drivers/net/ixgbe/base/ixgbe_common.c index 21f973e5e0..fb50719fb0 100644 --- a/drivers/net/ixgbe/base/ixgbe_common.c +++ b/drivers/net/ixgbe/base/ixgbe_common.c @@ -5259,7 +5259,7 @@ s32 ixgbe_setup_mac_link_multispeed_fiber(struct ixgbe_hw *hw, ixgbe_flap_tx_laser(hw); /* Wait for the controller to acquire link. Per IEEE 802.3ap, - * Section 73.10.2, we may have to wait up to 500ms if KR is + * Section 73.10.2, we may have to wait up to 1000ms if KR is * attempted. 82599 uses the same timing for 10g SFI. */ for (i = 0; i < 10; i++) { -- 2.20.1