.. BSD LICENSE Copyright(c) 2016 Intel Corporation. All rights reserved. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: * Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. * Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. * Neither the name of Intel Corporation nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. I40E Poll Mode Driver ====================== The I40E PMD (librte_pmd_i40e) provides poll mode driver support for the Intel X710/XL710/X722 10/40 Gbps family of adapters. Features -------- Features of the I40E PMD are: - Multiple queues for TX and RX - Receiver Side Scaling (RSS) - MAC/VLAN filtering - Packet type information - Flow director - Cloud filter - Checksum offload - VLAN/QinQ stripping and inserting - TSO offload - Promiscuous mode - Multicast mode - Port hardware statistics - Jumbo frames - Link state information - Link flow control - Mirror on port, VLAN and VSI - Interrupt mode for RX - Scattered and gather for TX and RX - Vector Poll mode driver - DCB - VMDQ - SR-IOV VF - Hot plug - IEEE1588/802.1AS timestamping Prerequisites ------------- - Identifying your adapter using `Intel Support `_ and get the latest NVM/FW images. - Follow the DPDK :ref:`Getting Started Guide for Linux ` to setup the basic DPDK environment. - To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms" section of the :ref:`Getting Started Guide for Linux `. Pre-Installation Configuration ------------------------------ Config File Options ~~~~~~~~~~~~~~~~~~~ The following options can be modified in the ``config`` file. Please note that enabling debugging options may affect system performance. - ``CONFIG_RTE_LIBRTE_I40E_PMD`` (default ``y``) Toggle compilation of the ``librte_pmd_i40e`` driver. - ``CONFIG_RTE_LIBRTE_I40E_DEBUG_*`` (default ``n``) Toggle display of generic debugging messages. - ``CONFIG_RTE_LIBRTE_I40E_RX_ALLOW_BULK_ALLOC`` (default ``y``) Toggle bulk allocation for RX. - ``CONFIG_RTE_LIBRTE_I40E_INC_VECTOR`` (default ``n``) Toggle the use of Vector PMD instead of normal RX/TX path. To enable vPMD for RX, bulk allocation for Rx must be allowed. - ``CONFIG_RTE_LIBRTE_I40E_RX_OLFLAGS_ENABLE`` (default ``y``) Toggle to enable RX ``olflags``. This is only meaningful when Vector PMD is used. - ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` (default ``n``) Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte. - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``) Number of queues reserved for PF. - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VF`` (default ``4``) Number of queues reserved for each SR-IOV VF. - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``) Number of queues reserved for each VMDQ Pool. - ``CONFIG_RTE_LIBRTE_I40E_ITR_INTERVAL`` (default ``-1``) Interrupt Throttling interval. Driver Compilation ~~~~~~~~~~~~~~~~~~ To compile the I40E PMD see :ref:`Getting Started Guide for Linux ` or :ref:`Getting Started Guide for FreeBSD ` depending on your platform. Linux ----- Running testpmd ~~~~~~~~~~~~~~~ This section demonstrates how to launch ``testpmd`` with Intel XL710/X710 devices managed by ``librte_pmd_i40e`` in the Linux operating system. #. Load ``igb_uio`` or ``vfio-pci`` driver: .. code-block:: console modprobe uio insmod ./x86_64-native-linuxapp-gcc/kmod/igb_uio.ko or .. code-block:: console modprobe vfio-pci #. Bind the XL710/X710 adapters to ``igb_uio`` or ``vfio-pci`` loaded in the previous step: .. code-block:: console ./tools/dpdk_nic_bind.py --bind igb_uio 0000:83:00.0 Or setup VFIO permissions for regular users and then bind to ``vfio-pci``: .. code-block:: console ./tools/dpdk_nic_bind.py --bind vfio-pci 0000:83:00.0 #. Start ``testpmd`` with basic parameters: .. code-block:: console ./x86_64-native-linuxapp-gcc/app/testpmd -c 0xf -n 4 -w 83:00.0 -- -i Example output: .. code-block:: console ... EAL: PCI device 0000:83:00.0 on NUMA socket 1 EAL: probe driver: 8086:1572 rte_i40e_pmd EAL: PCI memory mapped at 0x7f7f80000000 EAL: PCI memory mapped at 0x7f7f80800000 PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a Interactive-mode selected Configuring Port 0 (socket 0) ... PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0. ... Port 0: 68:05:CA:26:85:84 Checking link statuses... Port 0 Link Up - speed 10000 Mbps - full-duplex Done testpmd> SR-IOV: Prerequisites and sample Application Notes ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ #. Load the kernel module: .. code-block:: console modprobe i40e Check the output in dmesg: .. code-block:: console i40e 0000:83:00.1 ens802f0: renamed from eth0 #. Bring up the PF ports: .. code-block:: console ifconfig ens802f0 up #. Create VF device(s): Echo the number of VFs to be created into the ``sriov_numvfs`` sysfs entry of the parent PF. Example: .. code-block:: console echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs #. Assign VF MAC address: Assign MAC address to the VF using iproute2 utility. The syntax is: .. code-block:: console ip link set vf mac Example: .. code-block:: console ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0 #. Assign VF to VM, and bring up the VM. Please see the documentation for the *I40E/IXGBE/IGB Virtual Function Driver*. Sample Application Notes ------------------------ Vlan filter ~~~~~~~~~~~ Vlan filter only works when Promiscuous mode is off. To start ``testpmd``, and add vlan 10 to port 0: .. code-block:: console ./app/testpmd -c ffff -n 4 -- -i --forward-mode=mac ... testpmd> set promisc 0 off testpmd> rx_vlan add 10 0 Flow Director ~~~~~~~~~~~~~ The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues. The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload. The default input set of each flow type is:: ipv4-other : src_ip_address, dst_ip_address ipv4-frag : src_ip_address, dst_ip_address ipv4-tcp : src_ip_address, dst_ip_address, src_port, dst_port ipv4-udp : src_ip_address, dst_ip_address, src_port, dst_port ipv4-sctp : src_ip_address, dst_ip_address, src_port, dst_port, verification_tag ipv6-other : src_ip_address, dst_ip_address ipv6-frag : src_ip_address, dst_ip_address ipv6-tcp : src_ip_address, dst_ip_address, src_port, dst_port ipv6-udp : src_ip_address, dst_ip_address, src_port, dst_port ipv6-sctp : src_ip_address, dst_ip_address, src_port, dst_port, verification_tag l2_payload : ether_type The flex payload is selected from offset 0 to 15 of packet's payload by default, while it is masked out from matching. Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``: .. code-block:: console ./app/testpmd -c ffff -n 4 -- -i --disable-rss --pkt-filter-mode=perfect \ --rxq=8 --txq=8 --nb-cores=8 --nb-ports=1 Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1: .. code-block:: console testpmd> flow_director_filter 0 mode IP add flow ipv4-udp \ src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \ fwd pf queue 1 fd_id 1 Check the flow director status: .. code-block:: console testpmd> show port fdir 0 ######################## FDIR infos for port 0 #################### MODE: PERFECT SUPPORTED FLOW TYPE: ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other l2_payload FLEX PAYLOAD INFO: max_len: 16 payload_limit: 480 payload_unit: 2 payload_seg: 3 bitmask_unit: 2 bitmask_num: 2 MASK: vlan_tci: 0x0000, src_ipv4: 0x00000000, dst_ipv4: 0x00000000, src_port: 0x0000, dst_port: 0x0000 src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000, dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000 FLEX PAYLOAD SRC OFFSET: L2_PAYLOAD: 0 1 2 3 4 5 6 ... L3_PAYLOAD: 0 1 2 3 4 5 6 ... L4_PAYLOAD: 0 1 2 3 4 5 6 ... FLEX MASK CFG: ipv4-udp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ipv4-tcp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ipv4-sctp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ipv4-other: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ipv4-frag: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ipv6-udp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ipv6-tcp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ipv6-sctp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ipv6-other: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ipv6-frag: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 l2_payload: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 guarant_count: 1 best_count: 0 guarant_space: 512 best_space: 7168 collision: 0 free: 0 maxhash: 0 maxlen: 0 add: 0 remove: 0 f_add: 0 f_remove: 0 Delete all flow director rules on a port: .. code-block:: console testpmd> flush_flow_director 0