From: Heinrich Kuhn Date: Thu, 3 Sep 2020 11:23:51 +0000 (+0200) Subject: doc: improve multiport PF in nfp guide X-Git-Url: http://git.droids-corp.org/?a=commitdiff_plain;h=979f2bae0714;p=dpdk.git doc: improve multiport PF in nfp guide The Agilio CX family of smartNIC's generally have a 1:many mapping of PF to physical ports. Elaborate on this mapping in the PF multiport section of the NFP PMD documentation. Fixes: d625beafc8be ("doc: update NFP with PF support information") Cc: stable@dpdk.org Signed-off-by: Heinrich Kuhn Signed-off-by: Simon Horman --- diff --git a/doc/guides/nics/nfp.rst b/doc/guides/nics/nfp.rst index 5f2a0698f6..020e37d131 100644 --- a/doc/guides/nics/nfp.rst +++ b/doc/guides/nics/nfp.rst @@ -102,22 +102,39 @@ directory per firmware application. Options 1 and 2 for firmware filenames allow more than one SmartNIC, same type of SmartNIC or different ones, and to upload a different firmware to each SmartNIC. + .. Note:: + Currently the NFP PMD supports using the PF with Agilio Basic Firmware. See + https://help.netronome.com/support/solutions for more information on the + various firmwares supported by the Netronome Agilio CX smartNIC. PF multiport support -------------------- -Some NFP cards support several physical ports with just one single PCI device. -The DPDK core is designed with a 1:1 relationship between PCI devices and DPDK -ports, so NFP PMD PF support requires handling the multiport case specifically. -During NFP PF initialization, the PMD will extract the information about the -number of PF ports from the firmware and will create as many DPDK ports as -needed. +The NFP PMD can work with up to 8 ports on the same PF device. The number of +available ports is firmware and hardware dependent, and the driver looks for a +firmware symbol during initialization to know how many can be used. -Because the unusual relationship between a single PCI device and several DPDK -ports, there are some limitations when using more than one PF DPDK port: there -is no support for RX interrupts and it is not possible either to use those PF -ports with the device hotplug functionality. +DPDK apps work with ports, and a port is usually a PF or a VF PCI device. +However, with the NFP PF multiport there is just one PF PCI device. Supporting +this particular configuration requires the PMD to create ports in a special way, +although once they are created, DPDK apps should be able to use them as normal +PCI ports. +NFP ports belonging to same PF can be seen inside PMD initialization with a +suffix added to the PCI ID: wwww:xx:yy.z_port_n. For example, a PF with PCI ID +0000:03:00.0 and four ports is seen by the PMD code as: + + .. code-block:: console + + 0000:03:00.0_port_0 + 0000:03:00.0_port_1 + 0000:03:00.0_port_2 + 0000:03:00.0_port_3 + + .. Note:: + + There are some limitations with multiport support: RX interrupts and + device hot-plugging are not supported. PF multiprocess support -----------------------