doc: fix spelling in i40e guide
[dpdk.git] / doc / guides / nics / i40e.rst
1 ..  SPDX-License-Identifier: BSD-3-Clause
2     Copyright(c) 2016 Intel Corporation.
3
4 I40E Poll Mode Driver
5 ======================
6
7 The i40e PMD (librte_pmd_i40e) provides poll mode driver support for
8 10/25/40 Gbps Intel® Ethernet 700 Series Network Adapters based on
9 the Intel Ethernet Controller X710/XL710/XXV710 and Intel Ethernet
10 Connection X722 (only support part of features).
11
12
13 Features
14 --------
15
16 Features of the i40e PMD are:
17
18 - Multiple queues for TX and RX
19 - Receiver Side Scaling (RSS)
20 - MAC/VLAN filtering
21 - Packet type information
22 - Flow director
23 - Cloud filter
24 - Checksum offload
25 - VLAN/QinQ stripping and inserting
26 - TSO offload
27 - Promiscuous mode
28 - Multicast mode
29 - Port hardware statistics
30 - Jumbo frames
31 - Link state information
32 - Link flow control
33 - Mirror on port, VLAN and VSI
34 - Interrupt mode for RX
35 - Scattered and gather for TX and RX
36 - Vector Poll mode driver
37 - DCB
38 - VMDQ
39 - SR-IOV VF
40 - Hot plug
41 - IEEE1588/802.1AS timestamping
42 - VF Daemon (VFD) - EXPERIMENTAL
43 - Dynamic Device Personalization (DDP)
44 - Queue region configuration
45 - Virtual Function Port Representors
46
47 Prerequisites
48 -------------
49
50 - Identifying your adapter using `Intel Support
51   <http://www.intel.com/support>`_ and get the latest NVM/FW images.
52
53 - Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
54
55 - To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms"
56   section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
57
58 - Upgrade the NVM/FW version following the `Intel® Ethernet NVM Update Tool Quick Usage Guide for Linux
59   <https://www-ssl.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-linux-usage-guide.html>`_ and `Intel® Ethernet NVM Update Tool: Quick Usage Guide for EFI <https://www.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-efi-usage-guide.html>`_ if needed.
60
61 Pre-Installation Configuration
62 ------------------------------
63
64 Config File Options
65 ~~~~~~~~~~~~~~~~~~~
66
67 The following options can be modified in the ``config`` file.
68 Please note that enabling debugging options may affect system performance.
69
70 - ``CONFIG_RTE_LIBRTE_I40E_PMD`` (default ``y``)
71
72   Toggle compilation of the ``librte_pmd_i40e`` driver.
73
74 - ``CONFIG_RTE_LIBRTE_I40E_DEBUG_*`` (default ``n``)
75
76   Toggle display of generic debugging messages.
77
78 - ``CONFIG_RTE_LIBRTE_I40E_RX_ALLOW_BULK_ALLOC`` (default ``y``)
79
80   Toggle bulk allocation for RX.
81
82 - ``CONFIG_RTE_LIBRTE_I40E_INC_VECTOR`` (default ``n``)
83
84   Toggle the use of Vector PMD instead of normal RX/TX path.
85   To enable vPMD for RX, bulk allocation for Rx must be allowed.
86
87 - ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` (default ``n``)
88
89   Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte.
90
91 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
92
93   Number of queues reserved for PF.
94
95 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
96
97   Number of queues reserved for each VMDQ Pool.
98
99 - ``CONFIG_RTE_LIBRTE_I40E_ITR_INTERVAL`` (default ``-1``)
100
101   Interrupt Throttling interval.
102
103
104 Runtime Config Options
105 ~~~~~~~~~~~~~~~~~~~~~~
106
107 - ``Number of Queues per VF`` (default ``4``)
108
109   The number of queue per VF is determined by its host PF. If the PCI address
110   of an i40e PF is aaaa:bb.cc, the number of queues per VF can be configured
111   with EAL parameter like -w aaaa:bb.cc,queue-num-per-vf=n. The value n can be
112   1, 2, 4, 8 or 16. If no such parameter is configured, the number of queues
113   per VF is 4 by default.
114
115 - ``Support multiple driver`` (default ``disable``)
116
117   There was a multiple driver support issue during use of 700 series Ethernet
118   Adapter with both Linux kernel and DPDK PMD. To fix this issue, ``devargs``
119   parameter ``support-multi-driver`` is introduced, for example::
120
121     -w 84:00.0,support-multi-driver=1
122
123   With the above configuration, DPDK PMD will not change global registers, and
124   will switch PF interrupt from IntN to Int0 to avoid interrupt conflict between
125   DPDK and Linux Kernel.
126
127 - ``Support VF Port Representor`` (default ``not enabled``)
128
129   The i40e PF PMD supports the creation of VF port representors for the control
130   and monitoring of i40e virtual function devices. Each port representor
131   corresponds to a single virtual function of that device. Using the ``devargs``
132   option ``representor`` the user can specify which virtual functions to create
133   port representors for on initialization of the PF PMD by passing the VF IDs of
134   the VFs which are required.::
135
136   -w DBDF,representor=[0,1,4]
137
138   Currently hot-plugging of representor ports is not supported so all required
139   representors must be specified on the creation of the PF.
140
141 Driver compilation and testing
142 ------------------------------
143
144 Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
145 for details.
146
147
148 SR-IOV: Prerequisites and sample Application Notes
149 --------------------------------------------------
150
151 #. Load the kernel module:
152
153    .. code-block:: console
154
155       modprobe i40e
156
157    Check the output in dmesg:
158
159    .. code-block:: console
160
161       i40e 0000:83:00.1 ens802f0: renamed from eth0
162
163 #. Bring up the PF ports:
164
165    .. code-block:: console
166
167       ifconfig ens802f0 up
168
169 #. Create VF device(s):
170
171    Echo the number of VFs to be created into the ``sriov_numvfs`` sysfs entry
172    of the parent PF.
173
174    Example:
175
176    .. code-block:: console
177
178       echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
179
180
181 #. Assign VF MAC address:
182
183    Assign MAC address to the VF using iproute2 utility. The syntax is:
184
185    .. code-block:: console
186
187       ip link set <PF netdev id> vf <VF id> mac <macaddr>
188
189    Example:
190
191    .. code-block:: console
192
193       ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0
194
195 #. Assign VF to VM, and bring up the VM.
196    Please see the documentation for the *I40E/IXGBE/IGB Virtual Function Driver*.
197
198 #. Running testpmd:
199
200    Follow instructions available in the document
201    :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
202    to run testpmd.
203
204    Example output:
205
206    .. code-block:: console
207
208       ...
209       EAL: PCI device 0000:83:00.0 on NUMA socket 1
210       EAL: probe driver: 8086:1572 rte_i40e_pmd
211       EAL: PCI memory mapped at 0x7f7f80000000
212       EAL: PCI memory mapped at 0x7f7f80800000
213       PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a
214       Interactive-mode selected
215       Configuring Port 0 (socket 0)
216       ...
217
218       PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are
219       satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0.
220
221       ...
222       Port 0: 68:05:CA:26:85:84
223       Checking link statuses...
224       Port 0 Link Up - speed 10000 Mbps - full-duplex
225       Done
226
227       testpmd>
228
229
230 Sample Application Notes
231 ------------------------
232
233 Vlan filter
234 ~~~~~~~~~~~
235
236 Vlan filter only works when Promiscuous mode is off.
237
238 To start ``testpmd``, and add vlan 10 to port 0:
239
240 .. code-block:: console
241
242     ./app/testpmd -l 0-15 -n 4 -- -i --forward-mode=mac
243     ...
244
245     testpmd> set promisc 0 off
246     testpmd> rx_vlan add 10 0
247
248
249 Flow Director
250 ~~~~~~~~~~~~~
251
252 The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
253 The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload.
254
255 The default input set of each flow type is::
256
257    ipv4-other : src_ip_address, dst_ip_address
258    ipv4-frag  : src_ip_address, dst_ip_address
259    ipv4-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
260    ipv4-udp   : src_ip_address, dst_ip_address, src_port, dst_port
261    ipv4-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
262                 verification_tag
263    ipv6-other : src_ip_address, dst_ip_address
264    ipv6-frag  : src_ip_address, dst_ip_address
265    ipv6-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
266    ipv6-udp   : src_ip_address, dst_ip_address, src_port, dst_port
267    ipv6-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
268                 verification_tag
269    l2_payload : ether_type
270
271 The flex payload is selected from offset 0 to 15 of packet's payload by default, while it is masked out from matching.
272
273 Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``:
274
275 .. code-block:: console
276
277    ./app/testpmd -l 0-15 -n 4 -- -i --disable-rss --pkt-filter-mode=perfect \
278                  --rxq=8 --txq=8 --nb-cores=8 --nb-ports=1
279
280 Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1:
281
282 .. code-block:: console
283
284    testpmd> flow_director_filter 0 mode IP add flow ipv4-udp  \
285             src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \
286             fwd pf queue 1 fd_id 1
287
288 Check the flow director status:
289
290 .. code-block:: console
291
292    testpmd> show port fdir 0
293
294    ######################## FDIR infos for port 0      ####################
295      MODE:   PERFECT
296      SUPPORTED FLOW TYPE:  ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other
297                            ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other
298                            l2_payload
299      FLEX PAYLOAD INFO:
300      max_len:       16          payload_limit: 480
301      payload_unit:  2           payload_seg:   3
302      bitmask_unit:  2           bitmask_num:   2
303      MASK:
304        vlan_tci: 0x0000,
305        src_ipv4: 0x00000000,
306        dst_ipv4: 0x00000000,
307        src_port: 0x0000,
308        dst_port: 0x0000
309        src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000,
310        dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000
311      FLEX PAYLOAD SRC OFFSET:
312        L2_PAYLOAD:    0      1      2      3      4      5      6  ...
313        L3_PAYLOAD:    0      1      2      3      4      5      6  ...
314        L4_PAYLOAD:    0      1      2      3      4      5      6  ...
315      FLEX MASK CFG:
316        ipv4-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
317        ipv4-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
318        ipv4-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
319        ipv4-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
320        ipv4-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
321        ipv6-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
322        ipv6-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
323        ipv6-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
324        ipv6-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
325        ipv6-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
326        l2_payload:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
327      guarant_count: 1           best_count:    0
328      guarant_space: 512         best_space:    7168
329      collision:     0           free:          0
330      maxhash:       0           maxlen:        0
331      add:           0           remove:        0
332      f_add:         0           f_remove:      0
333
334
335 Delete all flow director rules on a port:
336
337 .. code-block:: console
338
339    testpmd> flush_flow_director 0
340
341 Floating VEB
342 ~~~~~~~~~~~~~
343
344 The Intel® Ethernet 700 Series support a feature called
345 "Floating VEB".
346
347 A Virtual Ethernet Bridge (VEB) is an IEEE Edge Virtual Bridging (EVB) term
348 for functionality that allows local switching between virtual endpoints within
349 a physical endpoint and also with an external bridge/network.
350
351 A "Floating" VEB doesn't have an uplink connection to the outside world so all
352 switching is done internally and remains within the host. As such, this
353 feature provides security benefits.
354
355 In addition, a Floating VEB overcomes a limitation of normal VEBs where they
356 cannot forward packets when the physical link is down. Floating VEBs don't need
357 to connect to the NIC port so they can still forward traffic from VF to VF
358 even when the physical link is down.
359
360 Therefore, with this feature enabled VFs can be limited to communicating with
361 each other but not an outside network, and they can do so even when there is
362 no physical uplink on the associated NIC port.
363
364 To enable this feature, the user should pass a ``devargs`` parameter to the
365 EAL, for example::
366
367     -w 84:00.0,enable_floating_veb=1
368
369 In this configuration the PMD will use the floating VEB feature for all the
370 VFs created by this PF device.
371
372 Alternatively, the user can specify which VFs need to connect to this floating
373 VEB using the ``floating_veb_list`` argument::
374
375     -w 84:00.0,enable_floating_veb=1,floating_veb_list=1;3-4
376
377 In this example ``VF1``, ``VF3`` and ``VF4`` connect to the floating VEB,
378 while other VFs connect to the normal VEB.
379
380 The current implementation only supports one floating VEB and one regular
381 VEB. VFs can connect to a floating VEB or a regular VEB according to the
382 configuration passed on the EAL command line.
383
384 The floating VEB functionality requires a NIC firmware version of 5.0
385 or greater.
386
387 Dynamic Device Personalization (DDP)
388 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
389
390 The Intel® Ethernet 700 Series except for the Intel Ethernet Connection
391 X722 support a feature called "Dynamic Device Personalization (DDP)",
392 which is used to configure hardware by downloading a profile to support
393 protocols/filters which are not supported by default. The DDP
394 functionality requires a NIC firmware version of 6.0 or greater.
395
396 Current implementation supports GTP-C/GTP-U/PPPoE/PPPoL2TP,
397 steering can be used with rte_flow API.
398
399 Load a profile which supports GTP and store backup profile:
400
401 .. code-block:: console
402
403    testpmd> ddp add 0 ./gtp.pkgo,./backup.pkgo
404
405 Delete a GTP profile and restore backup profile:
406
407 .. code-block:: console
408
409    testpmd> ddp del 0 ./backup.pkgo
410
411 Get loaded DDP package info list:
412
413 .. code-block:: console
414
415    testpmd> ddp get list 0
416
417 Display information about a GTP profile:
418
419 .. code-block:: console
420
421    testpmd> ddp get info ./gtp.pkgo
422
423 Input set configuration
424 ~~~~~~~~~~~~~~~~~~~~~~~
425 Input set for any PCTYPE can be configured with user defined configuration,
426 For example, to use only 48bit prefix for IPv6 src address for IPv6 TCP RSS:
427
428 .. code-block:: console
429
430    testpmd> port config 0 pctype 43 hash_inset clear all
431    testpmd> port config 0 pctype 43 hash_inset set field 13
432    testpmd> port config 0 pctype 43 hash_inset set field 14
433    testpmd> port config 0 pctype 43 hash_inset set field 15
434
435 Queue region configuration
436 ~~~~~~~~~~~~~~~~~~~~~~~~~~~
437 The Intel® Ethernet 700 Series supports a feature of queue regions
438 configuration for RSS in the PF, so that different traffic classes or
439 different packet classification types can be separated to different
440 queues in different queue regions. There is an API for configuration
441 of queue regions in RSS with a command line. It can parse the parameters
442 of the region index, queue number, queue start index, user priority, traffic
443 classes and so on. Depending on commands from the command line, it will call
444 i40e private APIs and start the process of setting or flushing the queue
445 region configuration. As this feature is specific for i40e only private
446 APIs are used. These new ``test_pmd`` commands are as shown below. For
447 details please refer to :doc:`../testpmd_app_ug/index`.
448
449 .. code-block:: console
450
451    testpmd> set port (port_id) queue-region region_id (value) \
452                 queue_start_index (value) queue_num (value)
453    testpmd> set port (port_id) queue-region region_id (value) flowtype (value)
454    testpmd> set port (port_id) queue-region UP (value) region_id (value)
455    testpmd> set port (port_id) queue-region flush (on|off)
456    testpmd> show port (port_id) queue-region
457
458 Limitations or Known issues
459 ---------------------------
460
461 MPLS packet classification
462 ~~~~~~~~~~~~~~~~~~~~~~~~~~
463
464 For firmware versions prior to 5.0, MPLS packets are not recognized by the NIC.
465 The L2 Payload flow type in flow director can be used to classify MPLS packet
466 by using a command in testpmd like:
467
468    testpmd> flow_director_filter 0 mode IP add flow l2_payload ether \
469             0x8847 flexbytes () fwd pf queue <N> fd_id <M>
470
471 With the NIC firmware version 5.0 or greater, some limited MPLS support
472 is added: Native MPLS (MPLS in Ethernet) skip is implemented, while no
473 new packet type, no classification or offload are possible. With this change,
474 L2 Payload flow type in flow director cannot be used to classify MPLS packet
475 as with previous firmware versions. Meanwhile, the Ethertype filter can be
476 used to classify MPLS packet by using a command in testpmd like:
477
478    testpmd> ethertype_filter 0 add mac_ignr 00:00:00:00:00:00 ethertype \
479             0x8847 fwd queue <M>
480
481 16 Byte RX Descriptor setting on DPDK VF
482 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
483
484 Currently the VF's RX descriptor mode is decided by PF. There's no PF-VF
485 interface for VF to request the RX descriptor mode, also no interface to notify
486 VF its own RX descriptor mode.
487 For all available versions of the i40e driver, these drivers don't support 16
488 byte RX descriptor. If the Linux i40e kernel driver is used as host driver,
489 while DPDK i40e PMD is used as the VF driver, DPDK cannot choose 16 byte receive
490 descriptor. The reason is that the RX descriptor is already set to 32 byte by
491 the i40e kernel driver. That is to say, user should keep
492 ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC=n`` in config file.
493 In the future, if the Linux i40e driver supports 16 byte RX descriptor, user
494 should make sure the DPDK VF uses the same RX descriptor mode, 16 byte or 32
495 byte, as the PF driver.
496
497 The same rule for DPDK PF + DPDK VF. The PF and VF should use the same RX
498 descriptor mode. Or the VF RX will not work.
499
500 Receive packets with Ethertype 0x88A8
501 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
502
503 Due to the FW limitation, PF can receive packets with Ethertype 0x88A8
504 only when floating VEB is disabled.
505
506 Incorrect Rx statistics when packet is oversize
507 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
508
509 When a packet is over maximum frame size, the packet is dropped.
510 However, the Rx statistics, when calling `rte_eth_stats_get` incorrectly
511 shows it as received.
512
513 VF & TC max bandwidth setting
514 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
515
516 The per VF max bandwidth and per TC max bandwidth cannot be enabled in parallel.
517 The behavior is different when handling per VF and per TC max bandwidth setting.
518 When enabling per VF max bandwidth, SW will check if per TC max bandwidth is
519 enabled. If so, return failure.
520 When enabling per TC max bandwidth, SW will check if per VF max bandwidth
521 is enabled. If so, disable per VF max bandwidth and continue with per TC max
522 bandwidth setting.
523
524 TC TX scheduling mode setting
525 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
526
527 There're 2 TX scheduling modes for TCs, round robin and strict priority mode.
528 If a TC is set to strict priority mode, it can consume unlimited bandwidth.
529 It means if APP has set the max bandwidth for that TC, it comes to no
530 effect.
531 It's suggested to set the strict priority mode for a TC that is latency
532 sensitive but no consuming much bandwidth.
533
534 VF performance is impacted by PCI extended tag setting
535 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
536
537 To reach maximum NIC performance in the VF the PCI extended tag must be
538 enabled. The DPDK i40e PF driver will set this feature during initialization,
539 but the kernel PF driver does not. So when running traffic on a VF which is
540 managed by the kernel PF driver, a significant NIC performance downgrade has
541 been observed (for 64 byte packets, there is about 25% line-rate downgrade for
542 a 25GbE device and about 35% for a 40GbE device).
543
544 For kernel version >= 4.11, the kernel's PCI driver will enable the extended
545 tag if it detects that the device supports it. So by default, this is not an
546 issue. For kernels <= 4.11 or when the PCI extended tag is disabled it can be
547 enabled using the steps below.
548
549 #. Get the current value of the PCI configure register::
550
551       setpci -s <XX:XX.X> a8.w
552
553 #. Set bit 8::
554
555       value = value | 0x100
556
557 #. Set the PCI configure register with new value::
558
559       setpci -s <XX:XX.X> a8.w=<value>
560
561 Vlan strip of VF
562 ~~~~~~~~~~~~~~~~
563
564 The VF vlan strip function is only supported in the i40e kernel driver >= 2.1.26.
565
566 DCB function
567 ~~~~~~~~~~~~
568
569 DCB works only when RSS is enabled.
570
571 Global configuration warning
572 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
573
574 I40E PMD will set some global registers to enable some function or set some
575 configure. Then when using different ports of the same NIC with Linux kernel
576 and DPDK, the port with Linux kernel will be impacted by the port with DPDK.
577 For example, register I40E_GL_SWT_L2TAGCTRL is used to control L2 tag, i40e
578 PMD uses I40E_GL_SWT_L2TAGCTRL to set vlan TPID. If setting TPID in port A
579 with DPDK, then the configuration will also impact port B in the NIC with
580 kernel driver, which don't want to use the TPID.
581 So PMD reports warning to clarify what is changed by writing global register.
582
583 High Performance of Small Packets on 40GbE NIC
584 ----------------------------------------------
585
586 As there might be firmware fixes for performance enhancement in latest version
587 of firmware image, the firmware update might be needed for getting high performance.
588 Check the Intel support website for the latest firmware updates.
589 Users should consult the release notes specific to a DPDK release to identify
590 the validated firmware version for a NIC using the i40e driver.
591
592 Use 16 Bytes RX Descriptor Size
593 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
594
595 As i40e PMD supports both 16 and 32 bytes RX descriptor sizes, and 16 bytes size can provide helps to high performance of small packets.
596 Configuration of ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` in config files can be changed to use 16 bytes size RX descriptors.
597
598 High Performance and per Packet Latency Tradeoff
599 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
600
601 Due to the hardware design, the interrupt signal inside NIC is needed for per
602 packet descriptor write-back. The minimum interval of interrupts could be set
603 at compile time by ``CONFIG_RTE_LIBRTE_I40E_ITR_INTERVAL`` in configuration files.
604 Though there is a default configuration, the interval could be tuned by the
605 users with that configuration item depends on what the user cares about more,
606 performance or per packet latency.
607
608 Example of getting best performance with l3fwd example
609 ------------------------------------------------------
610
611 The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with a
612 server with Intel Xeon processors and Intel Ethernet CNA XL710.
613
614 The example scenario is to get best performance with two Intel Ethernet CNA XL710 40GbE ports.
615 See :numref:`figure_intel_perf_test_setup` for the performance test setup.
616
617 .. _figure_intel_perf_test_setup:
618
619 .. figure:: img/intel_perf_test_setup.*
620
621    Performance Test Setup
622
623
624 1. Add two Intel Ethernet CNA XL710 to the platform, and use one port per card to get best performance.
625    The reason for using two NICs is to overcome a PCIe v3.0 limitation since it cannot provide 80GbE bandwidth
626    for two 40GbE ports, but two different PCIe v3.0 x8 slot can.
627    Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
628
629       82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
630       85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
631
632 2. Connect the ports to the traffic generator. For high speed testing, it's best to use a hardware traffic generator.
633
634 3. Check the PCI devices numa node (socket id) and get the cores number on the exact socket id.
635    In this case, ``82:00.0`` and ``85:00.0`` are both in socket 1, and the cores on socket 1 in the referenced platform
636    are 18-35 and 54-71.
637    Note: Don't use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical
638    cores from different cores (e.g core18 and core19).
639
640 4. Bind these two ports to igb_uio.
641
642 5. As to Intel Ethernet CNA XL710 40GbE port, we need at least two queue pairs to achieve best performance, then two queues per port
643    will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
644
645 6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
646    Compile the ``l3fwd sample`` with the default lpm mode.
647
648 7. The command line of running l3fwd would be something like the following::
649
650       ./l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \
651               -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
652
653    This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
654    core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
655
656 8. Configure the traffic at a traffic generator.
657
658    * Start creating a stream on packet generator.