doc: update driver/firmware versions in i40e guide
[dpdk.git] / doc / guides / nics / i40e.rst
1 ..  SPDX-License-Identifier: BSD-3-Clause
2     Copyright(c) 2016 Intel Corporation.
3
4 I40E Poll Mode Driver
5 ======================
6
7 The i40e PMD (librte_pmd_i40e) provides poll mode driver support for
8 10/25/40 Gbps Intel® Ethernet 700 Series Network Adapters based on
9 the Intel Ethernet Controller X710/XL710/XXV710 and Intel Ethernet
10 Connection X722 (only support part of features).
11
12
13 Features
14 --------
15
16 Features of the i40e PMD are:
17
18 - Multiple queues for TX and RX
19 - Receiver Side Scaling (RSS)
20 - MAC/VLAN filtering
21 - Packet type information
22 - Flow director
23 - Cloud filter
24 - Checksum offload
25 - VLAN/QinQ stripping and inserting
26 - TSO offload
27 - Promiscuous mode
28 - Multicast mode
29 - Port hardware statistics
30 - Jumbo frames
31 - Link state information
32 - Link flow control
33 - Mirror on port, VLAN and VSI
34 - Interrupt mode for RX
35 - Scattered and gather for TX and RX
36 - Vector Poll mode driver
37 - DCB
38 - VMDQ
39 - SR-IOV VF
40 - Hot plug
41 - IEEE1588/802.1AS timestamping
42 - VF Daemon (VFD) - EXPERIMENTAL
43 - Dynamic Device Personalization (DDP)
44 - Queue region configuration
45 - Virtual Function Port Representors
46 - Malicious Device Drive event catch and notify
47
48 Prerequisites
49 -------------
50
51 - Identifying your adapter using `Intel Support
52   <http://www.intel.com/support>`_ and get the latest NVM/FW images.
53
54 - Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
55
56 - To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms"
57   section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
58
59 - Upgrade the NVM/FW version following the `Intel® Ethernet NVM Update Tool Quick Usage Guide for Linux
60   <https://www-ssl.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-linux-usage-guide.html>`_ and `Intel® Ethernet NVM Update Tool: Quick Usage Guide for EFI <https://www.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-efi-usage-guide.html>`_ if needed.
61
62 Recommended Matching List
63 -------------------------
64
65 It is highly recommended to upgrade the i40e kernel driver and firmware to
66 avoid the compatibility issues with i40e PMD. Here is the suggested matching
67 list which has been tested and verified. The detailed information can refer
68 to chapter Tested Platforms/Tested NICs in release notes.
69
70 For X710/XL710/XXV710,
71
72    +--------------+-----------------------+------------------+
73    | DPDK version | Kernel driver version | Firmware version |
74    +==============+=======================+==================+
75    |    20.02     |         2.10.19       |       7.20       |
76    +--------------+-----------------------+------------------+
77    |    19.11     |         2.9.21        |       7.00       |
78    +--------------+-----------------------+------------------+
79    |    19.08     |         2.8.43        |       7.00       |
80    +--------------+-----------------------+------------------+
81    |    19.05     |         2.7.29        |       6.80       |
82    +--------------+-----------------------+------------------+
83    |    19.02     |         2.7.26        |       6.80       |
84    +--------------+-----------------------+------------------+
85    |    18.11     |         2.4.6         |       6.01       |
86    +--------------+-----------------------+------------------+
87    |    18.08     |         2.4.6         |       6.01       |
88    +--------------+-----------------------+------------------+
89    |    18.05     |         2.4.6         |       6.01       |
90    +--------------+-----------------------+------------------+
91    |    18.02     |         2.4.3         |       6.01       |
92    +--------------+-----------------------+------------------+
93    |    17.11     |         2.1.26        |       6.01       |
94    +--------------+-----------------------+------------------+
95    |    17.08     |         2.0.19        |       6.01       |
96    +--------------+-----------------------+------------------+
97    |    17.05     |         1.5.23        |       5.05       |
98    +--------------+-----------------------+------------------+
99    |    17.02     |         1.5.23        |       5.05       |
100    +--------------+-----------------------+------------------+
101    |    16.11     |         1.5.23        |       5.05       |
102    +--------------+-----------------------+------------------+
103    |    16.07     |         1.4.25        |       5.04       |
104    +--------------+-----------------------+------------------+
105    |    16.04     |         1.4.25        |       5.02       |
106    +--------------+-----------------------+------------------+
107
108
109 For X722,
110
111    +--------------+-----------------------+------------------+
112    | DPDK version | Kernel driver version | Firmware version |
113    +==============+=======================+==================+
114    |    20.02     |         2.10.19       |       4.11       |
115    +--------------+-----------------------+------------------+
116    |    19.11     |         2.9.21        |       4.10       |
117    +--------------+-----------------------+------------------+
118    |    19.08     |         2.9.21        |       4.10       |
119    +--------------+-----------------------+------------------+
120    |    19.05     |         2.7.29        |       3.33       |
121    +--------------+-----------------------+------------------+
122    |    19.02     |         2.7.26        |       3.33       |
123    +--------------+-----------------------+------------------+
124    |    18.11     |         2.4.6         |       3.33       |
125    +--------------+-----------------------+------------------+
126
127
128 Pre-Installation Configuration
129 ------------------------------
130
131 Config File Options
132 ~~~~~~~~~~~~~~~~~~~
133
134 The following options can be modified in the ``config`` file.
135 Please note that enabling debugging options may affect system performance.
136
137 - ``CONFIG_RTE_LIBRTE_I40E_PMD`` (default ``y``)
138
139   Toggle compilation of the ``librte_pmd_i40e`` driver.
140
141 - ``CONFIG_RTE_LIBRTE_I40E_DEBUG_*`` (default ``n``)
142
143   Toggle display of generic debugging messages.
144
145 - ``CONFIG_RTE_LIBRTE_I40E_RX_ALLOW_BULK_ALLOC`` (default ``y``)
146
147   Toggle bulk allocation for RX.
148
149 - ``CONFIG_RTE_LIBRTE_I40E_INC_VECTOR`` (default ``n``)
150
151   Toggle the use of Vector PMD instead of normal RX/TX path.
152   To enable vPMD for RX, bulk allocation for Rx must be allowed.
153
154 - ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` (default ``n``)
155
156   Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte.
157
158 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
159
160   Number of queues reserved for PF.
161
162 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
163
164   Number of queues reserved for each VMDQ Pool.
165
166 Runtime Config Options
167 ~~~~~~~~~~~~~~~~~~~~~~
168
169 - ``Reserved number of Queues per VF`` (default ``4``)
170
171   The number of reserved queue per VF is determined by its host PF. If the
172   PCI address of an i40e PF is aaaa:bb.cc, the number of reserved queues per
173   VF can be configured with EAL parameter like -w aaaa:bb.cc,queue-num-per-vf=n.
174   The value n can be 1, 2, 4, 8 or 16. If no such parameter is configured, the
175   number of reserved queues per VF is 4 by default. If VF request more than
176   reserved queues per VF, PF will able to allocate max to 16 queues after a VF
177   reset.
178
179
180 - ``Support multiple driver`` (default ``disable``)
181
182   There was a multiple driver support issue during use of 700 series Ethernet
183   Adapter with both Linux kernel and DPDK PMD. To fix this issue, ``devargs``
184   parameter ``support-multi-driver`` is introduced, for example::
185
186     -w 84:00.0,support-multi-driver=1
187
188   With the above configuration, DPDK PMD will not change global registers, and
189   will switch PF interrupt from IntN to Int0 to avoid interrupt conflict between
190   DPDK and Linux Kernel.
191
192 - ``Support VF Port Representor`` (default ``not enabled``)
193
194   The i40e PF PMD supports the creation of VF port representors for the control
195   and monitoring of i40e virtual function devices. Each port representor
196   corresponds to a single virtual function of that device. Using the ``devargs``
197   option ``representor`` the user can specify which virtual functions to create
198   port representors for on initialization of the PF PMD by passing the VF IDs of
199   the VFs which are required.::
200
201   -w DBDF,representor=[0,1,4]
202
203   Currently hot-plugging of representor ports is not supported so all required
204   representors must be specified on the creation of the PF.
205
206 - ``Use latest supported vector`` (default ``disable``)
207
208   Latest supported vector path may not always get the best perf so vector path was
209   recommended to use only on later platform. But users may want the latest vector path
210   since it can get better perf in some real work loading cases. So ``devargs`` param
211   ``use-latest-supported-vec`` is introduced, for example::
212
213   -w 84:00.0,use-latest-supported-vec=1
214
215 - ``Enable validation for VF message`` (default ``not enabled``)
216
217   The PF counts messages from each VF. If in any period of seconds the message
218   statistic from a VF exceeds maximal limitation, the PF will ignore any new message
219   from that VF for some seconds.
220   Format -- "maximal-message@period-seconds:ignore-seconds"
221   For example::
222
223   -w 84:00.0,vf_msg_cfg=80@120:180
224
225 Vector RX Pre-conditions
226 ~~~~~~~~~~~~~~~~~~~~~~~~
227 For Vector RX it is assumed that the number of descriptor rings will be a power
228 of 2. With this pre-condition, the ring pointer can easily scroll back to the
229 head after hitting the tail without a conditional check. In addition Vector RX
230 can use this assumption to do a bit mask using ``ring_size - 1``.
231
232 Driver compilation and testing
233 ------------------------------
234
235 Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
236 for details.
237
238
239 SR-IOV: Prerequisites and sample Application Notes
240 --------------------------------------------------
241
242 #. Load the kernel module:
243
244    .. code-block:: console
245
246       modprobe i40e
247
248    Check the output in dmesg:
249
250    .. code-block:: console
251
252       i40e 0000:83:00.1 ens802f0: renamed from eth0
253
254 #. Bring up the PF ports:
255
256    .. code-block:: console
257
258       ifconfig ens802f0 up
259
260 #. Create VF device(s):
261
262    Echo the number of VFs to be created into the ``sriov_numvfs`` sysfs entry
263    of the parent PF.
264
265    Example:
266
267    .. code-block:: console
268
269       echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
270
271
272 #. Assign VF MAC address:
273
274    Assign MAC address to the VF using iproute2 utility. The syntax is:
275
276    .. code-block:: console
277
278       ip link set <PF netdev id> vf <VF id> mac <macaddr>
279
280    Example:
281
282    .. code-block:: console
283
284       ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0
285
286 #. Assign VF to VM, and bring up the VM.
287    Please see the documentation for the *I40E/IXGBE/IGB Virtual Function Driver*.
288
289 #. Running testpmd:
290
291    Follow instructions available in the document
292    :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
293    to run testpmd.
294
295    Example output:
296
297    .. code-block:: console
298
299       ...
300       EAL: PCI device 0000:83:00.0 on NUMA socket 1
301       EAL: probe driver: 8086:1572 rte_i40e_pmd
302       EAL: PCI memory mapped at 0x7f7f80000000
303       EAL: PCI memory mapped at 0x7f7f80800000
304       PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a
305       Interactive-mode selected
306       Configuring Port 0 (socket 0)
307       ...
308
309       PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are
310       satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0.
311
312       ...
313       Port 0: 68:05:CA:26:85:84
314       Checking link statuses...
315       Port 0 Link Up - speed 10000 Mbps - full-duplex
316       Done
317
318       testpmd>
319
320
321 Sample Application Notes
322 ------------------------
323
324 Vlan filter
325 ~~~~~~~~~~~
326
327 Vlan filter only works when Promiscuous mode is off.
328
329 To start ``testpmd``, and add vlan 10 to port 0:
330
331 .. code-block:: console
332
333     ./app/testpmd -l 0-15 -n 4 -- -i --forward-mode=mac
334     ...
335
336     testpmd> set promisc 0 off
337     testpmd> rx_vlan add 10 0
338
339
340 Flow Director
341 ~~~~~~~~~~~~~
342
343 The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
344 The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload.
345
346 The default input set of each flow type is::
347
348    ipv4-other : src_ip_address, dst_ip_address
349    ipv4-frag  : src_ip_address, dst_ip_address
350    ipv4-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
351    ipv4-udp   : src_ip_address, dst_ip_address, src_port, dst_port
352    ipv4-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
353                 verification_tag
354    ipv6-other : src_ip_address, dst_ip_address
355    ipv6-frag  : src_ip_address, dst_ip_address
356    ipv6-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
357    ipv6-udp   : src_ip_address, dst_ip_address, src_port, dst_port
358    ipv6-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
359                 verification_tag
360    l2_payload : ether_type
361
362 The flex payload is selected from offset 0 to 15 of packet's payload by default, while it is masked out from matching.
363
364 Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``:
365
366 .. code-block:: console
367
368    ./app/testpmd -l 0-15 -n 4 -- -i --disable-rss --pkt-filter-mode=perfect \
369                  --rxq=8 --txq=8 --nb-cores=8 --nb-ports=1
370
371 Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1:
372
373 .. code-block:: console
374
375    testpmd> flow_director_filter 0 mode IP add flow ipv4-udp  \
376             src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \
377             fwd pf queue 1 fd_id 1
378
379 Check the flow director status:
380
381 .. code-block:: console
382
383    testpmd> show port fdir 0
384
385    ######################## FDIR infos for port 0      ####################
386      MODE:   PERFECT
387      SUPPORTED FLOW TYPE:  ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other
388                            ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other
389                            l2_payload
390      FLEX PAYLOAD INFO:
391      max_len:       16          payload_limit: 480
392      payload_unit:  2           payload_seg:   3
393      bitmask_unit:  2           bitmask_num:   2
394      MASK:
395        vlan_tci: 0x0000,
396        src_ipv4: 0x00000000,
397        dst_ipv4: 0x00000000,
398        src_port: 0x0000,
399        dst_port: 0x0000
400        src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000,
401        dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000
402      FLEX PAYLOAD SRC OFFSET:
403        L2_PAYLOAD:    0      1      2      3      4      5      6  ...
404        L3_PAYLOAD:    0      1      2      3      4      5      6  ...
405        L4_PAYLOAD:    0      1      2      3      4      5      6  ...
406      FLEX MASK CFG:
407        ipv4-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
408        ipv4-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
409        ipv4-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
410        ipv4-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
411        ipv4-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
412        ipv6-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
413        ipv6-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
414        ipv6-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
415        ipv6-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
416        ipv6-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
417        l2_payload:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
418      guarant_count: 1           best_count:    0
419      guarant_space: 512         best_space:    7168
420      collision:     0           free:          0
421      maxhash:       0           maxlen:        0
422      add:           0           remove:        0
423      f_add:         0           f_remove:      0
424
425
426 Delete all flow director rules on a port:
427
428 .. code-block:: console
429
430    testpmd> flush_flow_director 0
431
432 Floating VEB
433 ~~~~~~~~~~~~~
434
435 The Intel® Ethernet 700 Series support a feature called
436 "Floating VEB".
437
438 A Virtual Ethernet Bridge (VEB) is an IEEE Edge Virtual Bridging (EVB) term
439 for functionality that allows local switching between virtual endpoints within
440 a physical endpoint and also with an external bridge/network.
441
442 A "Floating" VEB doesn't have an uplink connection to the outside world so all
443 switching is done internally and remains within the host. As such, this
444 feature provides security benefits.
445
446 In addition, a Floating VEB overcomes a limitation of normal VEBs where they
447 cannot forward packets when the physical link is down. Floating VEBs don't need
448 to connect to the NIC port so they can still forward traffic from VF to VF
449 even when the physical link is down.
450
451 Therefore, with this feature enabled VFs can be limited to communicating with
452 each other but not an outside network, and they can do so even when there is
453 no physical uplink on the associated NIC port.
454
455 To enable this feature, the user should pass a ``devargs`` parameter to the
456 EAL, for example::
457
458     -w 84:00.0,enable_floating_veb=1
459
460 In this configuration the PMD will use the floating VEB feature for all the
461 VFs created by this PF device.
462
463 Alternatively, the user can specify which VFs need to connect to this floating
464 VEB using the ``floating_veb_list`` argument::
465
466     -w 84:00.0,enable_floating_veb=1,floating_veb_list=1;3-4
467
468 In this example ``VF1``, ``VF3`` and ``VF4`` connect to the floating VEB,
469 while other VFs connect to the normal VEB.
470
471 The current implementation only supports one floating VEB and one regular
472 VEB. VFs can connect to a floating VEB or a regular VEB according to the
473 configuration passed on the EAL command line.
474
475 The floating VEB functionality requires a NIC firmware version of 5.0
476 or greater.
477
478 Dynamic Device Personalization (DDP)
479 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
480
481 The Intel® Ethernet 700 Series except for the Intel Ethernet Connection
482 X722 support a feature called "Dynamic Device Personalization (DDP)",
483 which is used to configure hardware by downloading a profile to support
484 protocols/filters which are not supported by default. The DDP
485 functionality requires a NIC firmware version of 6.0 or greater.
486
487 Current implementation supports GTP-C/GTP-U/PPPoE/PPPoL2TP/ESP,
488 steering can be used with rte_flow API.
489
490 GTPv1 package is released, and it can be downloaded from
491 https://downloadcenter.intel.com/download/27587.
492
493 PPPoE package is released, and it can be downloaded from
494 https://downloadcenter.intel.com/download/28040.
495
496 ESP-AH package is not released yet.
497
498 Load a profile which supports GTP and store backup profile:
499
500 .. code-block:: console
501
502    testpmd> ddp add 0 ./gtp.pkgo,./backup.pkgo
503
504 Delete a GTP profile and restore backup profile:
505
506 .. code-block:: console
507
508    testpmd> ddp del 0 ./backup.pkgo
509
510 Get loaded DDP package info list:
511
512 .. code-block:: console
513
514    testpmd> ddp get list 0
515
516 Display information about a GTP profile:
517
518 .. code-block:: console
519
520    testpmd> ddp get info ./gtp.pkgo
521
522 Input set configuration
523 ~~~~~~~~~~~~~~~~~~~~~~~
524 Input set for any PCTYPE can be configured with user defined configuration,
525 For example, to use only 48bit prefix for IPv6 src address for IPv6 TCP RSS:
526
527 .. code-block:: console
528
529    testpmd> port config 0 pctype 43 hash_inset clear all
530    testpmd> port config 0 pctype 43 hash_inset set field 13
531    testpmd> port config 0 pctype 43 hash_inset set field 14
532    testpmd> port config 0 pctype 43 hash_inset set field 15
533
534 Queue region configuration
535 ~~~~~~~~~~~~~~~~~~~~~~~~~~~
536 The Intel® Ethernet 700 Series supports a feature of queue regions
537 configuration for RSS in the PF, so that different traffic classes or
538 different packet classification types can be separated to different
539 queues in different queue regions. There is an API for configuration
540 of queue regions in RSS with a command line. It can parse the parameters
541 of the region index, queue number, queue start index, user priority, traffic
542 classes and so on. Depending on commands from the command line, it will call
543 i40e private APIs and start the process of setting or flushing the queue
544 region configuration. As this feature is specific for i40e only private
545 APIs are used. These new ``test_pmd`` commands are as shown below. For
546 details please refer to :doc:`../testpmd_app_ug/index`.
547
548 .. code-block:: console
549
550    testpmd> set port (port_id) queue-region region_id (value) \
551                 queue_start_index (value) queue_num (value)
552    testpmd> set port (port_id) queue-region region_id (value) flowtype (value)
553    testpmd> set port (port_id) queue-region UP (value) region_id (value)
554    testpmd> set port (port_id) queue-region flush (on|off)
555    testpmd> show port (port_id) queue-region
556
557 Limitations or Known issues
558 ---------------------------
559
560 MPLS packet classification
561 ~~~~~~~~~~~~~~~~~~~~~~~~~~
562
563 For firmware versions prior to 5.0, MPLS packets are not recognized by the NIC.
564 The L2 Payload flow type in flow director can be used to classify MPLS packet
565 by using a command in testpmd like:
566
567    testpmd> flow_director_filter 0 mode IP add flow l2_payload ether \
568             0x8847 flexbytes () fwd pf queue <N> fd_id <M>
569
570 With the NIC firmware version 5.0 or greater, some limited MPLS support
571 is added: Native MPLS (MPLS in Ethernet) skip is implemented, while no
572 new packet type, no classification or offload are possible. With this change,
573 L2 Payload flow type in flow director cannot be used to classify MPLS packet
574 as with previous firmware versions. Meanwhile, the Ethertype filter can be
575 used to classify MPLS packet by using a command in testpmd like:
576
577    testpmd> ethertype_filter 0 add mac_ignr 00:00:00:00:00:00 ethertype \
578             0x8847 fwd queue <M>
579
580 16 Byte RX Descriptor setting on DPDK VF
581 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
582
583 Currently the VF's RX descriptor mode is decided by PF. There's no PF-VF
584 interface for VF to request the RX descriptor mode, also no interface to notify
585 VF its own RX descriptor mode.
586 For all available versions of the i40e driver, these drivers don't support 16
587 byte RX descriptor. If the Linux i40e kernel driver is used as host driver,
588 while DPDK i40e PMD is used as the VF driver, DPDK cannot choose 16 byte receive
589 descriptor. The reason is that the RX descriptor is already set to 32 byte by
590 the i40e kernel driver. That is to say, user should keep
591 ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC=n`` in config file.
592 In the future, if the Linux i40e driver supports 16 byte RX descriptor, user
593 should make sure the DPDK VF uses the same RX descriptor mode, 16 byte or 32
594 byte, as the PF driver.
595
596 The same rule for DPDK PF + DPDK VF. The PF and VF should use the same RX
597 descriptor mode. Or the VF RX will not work.
598
599 Receive packets with Ethertype 0x88A8
600 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
601
602 Due to the FW limitation, PF can receive packets with Ethertype 0x88A8
603 only when floating VEB is disabled.
604
605 Incorrect Rx statistics when packet is oversize
606 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
607
608 When a packet is over maximum frame size, the packet is dropped.
609 However, the Rx statistics, when calling `rte_eth_stats_get` incorrectly
610 shows it as received.
611
612 VF & TC max bandwidth setting
613 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
614
615 The per VF max bandwidth and per TC max bandwidth cannot be enabled in parallel.
616 The behavior is different when handling per VF and per TC max bandwidth setting.
617 When enabling per VF max bandwidth, SW will check if per TC max bandwidth is
618 enabled. If so, return failure.
619 When enabling per TC max bandwidth, SW will check if per VF max bandwidth
620 is enabled. If so, disable per VF max bandwidth and continue with per TC max
621 bandwidth setting.
622
623 TC TX scheduling mode setting
624 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
625
626 There are 2 TX scheduling modes for TCs, round robin and strict priority mode.
627 If a TC is set to strict priority mode, it can consume unlimited bandwidth.
628 It means if APP has set the max bandwidth for that TC, it comes to no
629 effect.
630 It's suggested to set the strict priority mode for a TC that is latency
631 sensitive but no consuming much bandwidth.
632
633 VF performance is impacted by PCI extended tag setting
634 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
635
636 To reach maximum NIC performance in the VF the PCI extended tag must be
637 enabled. The DPDK i40e PF driver will set this feature during initialization,
638 but the kernel PF driver does not. So when running traffic on a VF which is
639 managed by the kernel PF driver, a significant NIC performance downgrade has
640 been observed (for 64 byte packets, there is about 25% line-rate downgrade for
641 a 25GbE device and about 35% for a 40GbE device).
642
643 For kernel version >= 4.11, the kernel's PCI driver will enable the extended
644 tag if it detects that the device supports it. So by default, this is not an
645 issue. For kernels <= 4.11 or when the PCI extended tag is disabled it can be
646 enabled using the steps below.
647
648 #. Get the current value of the PCI configure register::
649
650       setpci -s <XX:XX.X> a8.w
651
652 #. Set bit 8::
653
654       value = value | 0x100
655
656 #. Set the PCI configure register with new value::
657
658       setpci -s <XX:XX.X> a8.w=<value>
659
660 Vlan strip of VF
661 ~~~~~~~~~~~~~~~~
662
663 The VF vlan strip function is only supported in the i40e kernel driver >= 2.1.26.
664
665 DCB function
666 ~~~~~~~~~~~~
667
668 DCB works only when RSS is enabled.
669
670 Global configuration warning
671 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
672
673 I40E PMD will set some global registers to enable some function or set some
674 configure. Then when using different ports of the same NIC with Linux kernel
675 and DPDK, the port with Linux kernel will be impacted by the port with DPDK.
676 For example, register I40E_GL_SWT_L2TAGCTRL is used to control L2 tag, i40e
677 PMD uses I40E_GL_SWT_L2TAGCTRL to set vlan TPID. If setting TPID in port A
678 with DPDK, then the configuration will also impact port B in the NIC with
679 kernel driver, which don't want to use the TPID.
680 So PMD reports warning to clarify what is changed by writing global register.
681
682 High Performance of Small Packets on 40GbE NIC
683 ----------------------------------------------
684
685 As there might be firmware fixes for performance enhancement in latest version
686 of firmware image, the firmware update might be needed for getting high performance.
687 Check the Intel support website for the latest firmware updates.
688 Users should consult the release notes specific to a DPDK release to identify
689 the validated firmware version for a NIC using the i40e driver.
690
691 Use 16 Bytes RX Descriptor Size
692 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
693
694 As i40e PMD supports both 16 and 32 bytes RX descriptor sizes, and 16 bytes size can provide helps to high performance of small packets.
695 Configuration of ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` in config files can be changed to use 16 bytes size RX descriptors.
696
697 Example of getting best performance with l3fwd example
698 ------------------------------------------------------
699
700 The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with a
701 server with Intel Xeon processors and Intel Ethernet CNA XL710.
702
703 The example scenario is to get best performance with two Intel Ethernet CNA XL710 40GbE ports.
704 See :numref:`figure_intel_perf_test_setup` for the performance test setup.
705
706 .. _figure_intel_perf_test_setup:
707
708 .. figure:: img/intel_perf_test_setup.*
709
710    Performance Test Setup
711
712
713 1. Add two Intel Ethernet CNA XL710 to the platform, and use one port per card to get best performance.
714    The reason for using two NICs is to overcome a PCIe v3.0 limitation since it cannot provide 80GbE bandwidth
715    for two 40GbE ports, but two different PCIe v3.0 x8 slot can.
716    Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
717
718       82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
719       85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
720
721 2. Connect the ports to the traffic generator. For high speed testing, it's best to use a hardware traffic generator.
722
723 3. Check the PCI devices numa node (socket id) and get the cores number on the exact socket id.
724    In this case, ``82:00.0`` and ``85:00.0`` are both in socket 1, and the cores on socket 1 in the referenced platform
725    are 18-35 and 54-71.
726    Note: Don't use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical
727    cores from different cores (e.g core18 and core19).
728
729 4. Bind these two ports to igb_uio.
730
731 5. As to Intel Ethernet CNA XL710 40GbE port, we need at least two queue pairs to achieve best performance, then two queues per port
732    will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
733
734 6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
735    Compile the ``l3fwd sample`` with the default lpm mode.
736
737 7. The command line of running l3fwd would be something like the following::
738
739       ./l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \
740               -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
741
742    This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
743    core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
744
745 8. Configure the traffic at a traffic generator.
746
747    * Start creating a stream on packet generator.
748
749    * Set the Ethernet II type to 0x0800.
750
751 Tx bytes affected by the link status change
752 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
753
754 For firmware versions prior to 6.01 for X710 series and 3.33 for X722 series, the tx_bytes statistics data is affected by
755 the link down event. Each time the link status changes to down, the tx_bytes decreases 110 bytes.