net/i40e: support hash configuration in RSS flow
[dpdk.git] / doc / guides / nics / i40e.rst
1 ..  SPDX-License-Identifier: BSD-3-Clause
2     Copyright(c) 2016 Intel Corporation.
3
4 I40E Poll Mode Driver
5 ======================
6
7 The i40e PMD (librte_pmd_i40e) provides poll mode driver support for
8 10/25/40 Gbps Intel® Ethernet 700 Series Network Adapters based on
9 the Intel Ethernet Controller X710/XL710/XXV710 and Intel Ethernet
10 Connection X722 (only support part of features).
11
12
13 Features
14 --------
15
16 Features of the i40e PMD are:
17
18 - Multiple queues for TX and RX
19 - Receiver Side Scaling (RSS)
20 - MAC/VLAN filtering
21 - Packet type information
22 - Flow director
23 - Cloud filter
24 - Checksum offload
25 - VLAN/QinQ stripping and inserting
26 - TSO offload
27 - Promiscuous mode
28 - Multicast mode
29 - Port hardware statistics
30 - Jumbo frames
31 - Link state information
32 - Link flow control
33 - Mirror on port, VLAN and VSI
34 - Interrupt mode for RX
35 - Scattered and gather for TX and RX
36 - Vector Poll mode driver
37 - DCB
38 - VMDQ
39 - SR-IOV VF
40 - Hot plug
41 - IEEE1588/802.1AS timestamping
42 - VF Daemon (VFD) - EXPERIMENTAL
43 - Dynamic Device Personalization (DDP)
44 - Queue region configuration
45 - Virtual Function Port Representors
46 - Malicious Device Drive event catch and notify
47 - Generic flow API
48
49 Prerequisites
50 -------------
51
52 - Identifying your adapter using `Intel Support
53   <http://www.intel.com/support>`_ and get the latest NVM/FW images.
54
55 - Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
56
57 - To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms"
58   section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
59
60 - Upgrade the NVM/FW version following the `Intel® Ethernet NVM Update Tool Quick Usage Guide for Linux
61   <https://www-ssl.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-linux-usage-guide.html>`_ and `Intel® Ethernet NVM Update Tool: Quick Usage Guide for EFI <https://www.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-efi-usage-guide.html>`_ if needed.
62
63 - For information about supported media, please refer to this document: `Intel® Ethernet Controller X710/XXV710/XL710 Feature Support Matrix
64   <http://www.intel.com/content/dam/www/public/us/en/documents/release-notes/xl710-ethernet-controller-feature-matrix.pdf>`_.
65
66    .. Note::
67
68       * Some adapters based on the Intel(R) Ethernet Controller 700 Series only
69         support Intel Ethernet Optics modules. On these adapters, other modules are not
70         supported and will not function.
71
72       * For connections based on Intel(R) Ethernet Controller 700 Series,
73         support is dependent on your system board. Please see your vendor for details.
74
75       * In all cases Intel recommends using Intel Ethernet Optics; other modules
76         may function but are not validated by Intel. Contact Intel for supported media types.
77
78 Recommended Matching List
79 -------------------------
80
81 It is highly recommended to upgrade the i40e kernel driver and firmware to
82 avoid the compatibility issues with i40e PMD. Here is the suggested matching
83 list which has been tested and verified. The detailed information can refer
84 to chapter Tested Platforms/Tested NICs in release notes.
85
86 For X710/XL710/XXV710,
87
88    +--------------+-----------------------+------------------+
89    | DPDK version | Kernel driver version | Firmware version |
90    +==============+=======================+==================+
91    |    20.02     |         2.10.19       |       7.20       |
92    +--------------+-----------------------+------------------+
93    |    19.11     |         2.9.21        |       7.00       |
94    +--------------+-----------------------+------------------+
95    |    19.08     |         2.8.43        |       7.00       |
96    +--------------+-----------------------+------------------+
97    |    19.05     |         2.7.29        |       6.80       |
98    +--------------+-----------------------+------------------+
99    |    19.02     |         2.7.26        |       6.80       |
100    +--------------+-----------------------+------------------+
101    |    18.11     |         2.4.6         |       6.01       |
102    +--------------+-----------------------+------------------+
103    |    18.08     |         2.4.6         |       6.01       |
104    +--------------+-----------------------+------------------+
105    |    18.05     |         2.4.6         |       6.01       |
106    +--------------+-----------------------+------------------+
107    |    18.02     |         2.4.3         |       6.01       |
108    +--------------+-----------------------+------------------+
109    |    17.11     |         2.1.26        |       6.01       |
110    +--------------+-----------------------+------------------+
111    |    17.08     |         2.0.19        |       6.01       |
112    +--------------+-----------------------+------------------+
113    |    17.05     |         1.5.23        |       5.05       |
114    +--------------+-----------------------+------------------+
115    |    17.02     |         1.5.23        |       5.05       |
116    +--------------+-----------------------+------------------+
117    |    16.11     |         1.5.23        |       5.05       |
118    +--------------+-----------------------+------------------+
119    |    16.07     |         1.4.25        |       5.04       |
120    +--------------+-----------------------+------------------+
121    |    16.04     |         1.4.25        |       5.02       |
122    +--------------+-----------------------+------------------+
123
124
125 For X722,
126
127    +--------------+-----------------------+------------------+
128    | DPDK version | Kernel driver version | Firmware version |
129    +==============+=======================+==================+
130    |    20.02     |         2.10.19       |       4.11       |
131    +--------------+-----------------------+------------------+
132    |    19.11     |         2.9.21        |       4.10       |
133    +--------------+-----------------------+------------------+
134    |    19.08     |         2.9.21        |       4.10       |
135    +--------------+-----------------------+------------------+
136    |    19.05     |         2.7.29        |       3.33       |
137    +--------------+-----------------------+------------------+
138    |    19.02     |         2.7.26        |       3.33       |
139    +--------------+-----------------------+------------------+
140    |    18.11     |         2.4.6         |       3.33       |
141    +--------------+-----------------------+------------------+
142
143
144 Pre-Installation Configuration
145 ------------------------------
146
147 Config File Options
148 ~~~~~~~~~~~~~~~~~~~
149
150 The following options can be modified in the ``config`` file.
151 Please note that enabling debugging options may affect system performance.
152
153 - ``CONFIG_RTE_LIBRTE_I40E_PMD`` (default ``y``)
154
155   Toggle compilation of the ``librte_pmd_i40e`` driver.
156
157 - ``CONFIG_RTE_LIBRTE_I40E_DEBUG_*`` (default ``n``)
158
159   Toggle display of generic debugging messages.
160
161 - ``CONFIG_RTE_LIBRTE_I40E_RX_ALLOW_BULK_ALLOC`` (default ``y``)
162
163   Toggle bulk allocation for RX.
164
165 - ``CONFIG_RTE_LIBRTE_I40E_INC_VECTOR`` (default ``n``)
166
167   Toggle the use of Vector PMD instead of normal RX/TX path.
168   To enable vPMD for RX, bulk allocation for Rx must be allowed.
169
170 - ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` (default ``n``)
171
172   Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte.
173
174 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
175
176   Number of queues reserved for PF.
177
178 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
179
180   Number of queues reserved for each VMDQ Pool.
181
182 Runtime Config Options
183 ~~~~~~~~~~~~~~~~~~~~~~
184
185 - ``Reserved number of Queues per VF`` (default ``4``)
186
187   The number of reserved queue per VF is determined by its host PF. If the
188   PCI address of an i40e PF is aaaa:bb.cc, the number of reserved queues per
189   VF can be configured with EAL parameter like -w aaaa:bb.cc,queue-num-per-vf=n.
190   The value n can be 1, 2, 4, 8 or 16. If no such parameter is configured, the
191   number of reserved queues per VF is 4 by default. If VF request more than
192   reserved queues per VF, PF will able to allocate max to 16 queues after a VF
193   reset.
194
195
196 - ``Support multiple driver`` (default ``disable``)
197
198   There was a multiple driver support issue during use of 700 series Ethernet
199   Adapter with both Linux kernel and DPDK PMD. To fix this issue, ``devargs``
200   parameter ``support-multi-driver`` is introduced, for example::
201
202     -w 84:00.0,support-multi-driver=1
203
204   With the above configuration, DPDK PMD will not change global registers, and
205   will switch PF interrupt from IntN to Int0 to avoid interrupt conflict between
206   DPDK and Linux Kernel.
207
208 - ``Support VF Port Representor`` (default ``not enabled``)
209
210   The i40e PF PMD supports the creation of VF port representors for the control
211   and monitoring of i40e virtual function devices. Each port representor
212   corresponds to a single virtual function of that device. Using the ``devargs``
213   option ``representor`` the user can specify which virtual functions to create
214   port representors for on initialization of the PF PMD by passing the VF IDs of
215   the VFs which are required.::
216
217   -w DBDF,representor=[0,1,4]
218
219   Currently hot-plugging of representor ports is not supported so all required
220   representors must be specified on the creation of the PF.
221
222 - ``Use latest supported vector`` (default ``disable``)
223
224   Latest supported vector path may not always get the best perf so vector path was
225   recommended to use only on later platform. But users may want the latest vector path
226   since it can get better perf in some real work loading cases. So ``devargs`` param
227   ``use-latest-supported-vec`` is introduced, for example::
228
229   -w 84:00.0,use-latest-supported-vec=1
230
231 - ``Enable validation for VF message`` (default ``not enabled``)
232
233   The PF counts messages from each VF. If in any period of seconds the message
234   statistic from a VF exceeds maximal limitation, the PF will ignore any new message
235   from that VF for some seconds.
236   Format -- "maximal-message@period-seconds:ignore-seconds"
237   For example::
238
239   -w 84:00.0,vf_msg_cfg=80@120:180
240
241 Vector RX Pre-conditions
242 ~~~~~~~~~~~~~~~~~~~~~~~~
243 For Vector RX it is assumed that the number of descriptor rings will be a power
244 of 2. With this pre-condition, the ring pointer can easily scroll back to the
245 head after hitting the tail without a conditional check. In addition Vector RX
246 can use this assumption to do a bit mask using ``ring_size - 1``.
247
248 Driver compilation and testing
249 ------------------------------
250
251 Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
252 for details.
253
254
255 SR-IOV: Prerequisites and sample Application Notes
256 --------------------------------------------------
257
258 #. Load the kernel module:
259
260    .. code-block:: console
261
262       modprobe i40e
263
264    Check the output in dmesg:
265
266    .. code-block:: console
267
268       i40e 0000:83:00.1 ens802f0: renamed from eth0
269
270 #. Bring up the PF ports:
271
272    .. code-block:: console
273
274       ifconfig ens802f0 up
275
276 #. Create VF device(s):
277
278    Echo the number of VFs to be created into the ``sriov_numvfs`` sysfs entry
279    of the parent PF.
280
281    Example:
282
283    .. code-block:: console
284
285       echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
286
287
288 #. Assign VF MAC address:
289
290    Assign MAC address to the VF using iproute2 utility. The syntax is:
291
292    .. code-block:: console
293
294       ip link set <PF netdev id> vf <VF id> mac <macaddr>
295
296    Example:
297
298    .. code-block:: console
299
300       ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0
301
302 #. Assign VF to VM, and bring up the VM.
303    Please see the documentation for the *I40E/IXGBE/IGB Virtual Function Driver*.
304
305 #. Running testpmd:
306
307    Follow instructions available in the document
308    :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
309    to run testpmd.
310
311    Example output:
312
313    .. code-block:: console
314
315       ...
316       EAL: PCI device 0000:83:00.0 on NUMA socket 1
317       EAL: probe driver: 8086:1572 rte_i40e_pmd
318       EAL: PCI memory mapped at 0x7f7f80000000
319       EAL: PCI memory mapped at 0x7f7f80800000
320       PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a
321       Interactive-mode selected
322       Configuring Port 0 (socket 0)
323       ...
324
325       PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are
326       satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0.
327
328       ...
329       Port 0: 68:05:CA:26:85:84
330       Checking link statuses...
331       Port 0 Link Up - speed 10000 Mbps - full-duplex
332       Done
333
334       testpmd>
335
336
337 Sample Application Notes
338 ------------------------
339
340 Vlan filter
341 ~~~~~~~~~~~
342
343 Vlan filter only works when Promiscuous mode is off.
344
345 To start ``testpmd``, and add vlan 10 to port 0:
346
347 .. code-block:: console
348
349     ./app/testpmd -l 0-15 -n 4 -- -i --forward-mode=mac
350     ...
351
352     testpmd> set promisc 0 off
353     testpmd> rx_vlan add 10 0
354
355
356 Flow Director
357 ~~~~~~~~~~~~~
358
359 The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
360 The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload.
361
362 The default input set of each flow type is::
363
364    ipv4-other : src_ip_address, dst_ip_address
365    ipv4-frag  : src_ip_address, dst_ip_address
366    ipv4-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
367    ipv4-udp   : src_ip_address, dst_ip_address, src_port, dst_port
368    ipv4-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
369                 verification_tag
370    ipv6-other : src_ip_address, dst_ip_address
371    ipv6-frag  : src_ip_address, dst_ip_address
372    ipv6-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
373    ipv6-udp   : src_ip_address, dst_ip_address, src_port, dst_port
374    ipv6-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
375                 verification_tag
376    l2_payload : ether_type
377
378 The flex payload is selected from offset 0 to 15 of packet's payload by default, while it is masked out from matching.
379
380 Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``:
381
382 .. code-block:: console
383
384    ./app/testpmd -l 0-15 -n 4 -- -i --disable-rss --pkt-filter-mode=perfect \
385                  --rxq=8 --txq=8 --nb-cores=8 --nb-ports=1
386
387 Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1:
388
389 .. code-block:: console
390
391    testpmd> flow_director_filter 0 mode IP add flow ipv4-udp  \
392             src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \
393             fwd pf queue 1 fd_id 1
394
395 Check the flow director status:
396
397 .. code-block:: console
398
399    testpmd> show port fdir 0
400
401    ######################## FDIR infos for port 0      ####################
402      MODE:   PERFECT
403      SUPPORTED FLOW TYPE:  ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other
404                            ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other
405                            l2_payload
406      FLEX PAYLOAD INFO:
407      max_len:       16          payload_limit: 480
408      payload_unit:  2           payload_seg:   3
409      bitmask_unit:  2           bitmask_num:   2
410      MASK:
411        vlan_tci: 0x0000,
412        src_ipv4: 0x00000000,
413        dst_ipv4: 0x00000000,
414        src_port: 0x0000,
415        dst_port: 0x0000
416        src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000,
417        dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000
418      FLEX PAYLOAD SRC OFFSET:
419        L2_PAYLOAD:    0      1      2      3      4      5      6  ...
420        L3_PAYLOAD:    0      1      2      3      4      5      6  ...
421        L4_PAYLOAD:    0      1      2      3      4      5      6  ...
422      FLEX MASK CFG:
423        ipv4-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
424        ipv4-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
425        ipv4-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
426        ipv4-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
427        ipv4-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
428        ipv6-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
429        ipv6-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
430        ipv6-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
431        ipv6-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
432        ipv6-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
433        l2_payload:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
434      guarant_count: 1           best_count:    0
435      guarant_space: 512         best_space:    7168
436      collision:     0           free:          0
437      maxhash:       0           maxlen:        0
438      add:           0           remove:        0
439      f_add:         0           f_remove:      0
440
441
442 Delete all flow director rules on a port:
443
444 .. code-block:: console
445
446    testpmd> flush_flow_director 0
447
448 Floating VEB
449 ~~~~~~~~~~~~~
450
451 The Intel® Ethernet 700 Series support a feature called
452 "Floating VEB".
453
454 A Virtual Ethernet Bridge (VEB) is an IEEE Edge Virtual Bridging (EVB) term
455 for functionality that allows local switching between virtual endpoints within
456 a physical endpoint and also with an external bridge/network.
457
458 A "Floating" VEB doesn't have an uplink connection to the outside world so all
459 switching is done internally and remains within the host. As such, this
460 feature provides security benefits.
461
462 In addition, a Floating VEB overcomes a limitation of normal VEBs where they
463 cannot forward packets when the physical link is down. Floating VEBs don't need
464 to connect to the NIC port so they can still forward traffic from VF to VF
465 even when the physical link is down.
466
467 Therefore, with this feature enabled VFs can be limited to communicating with
468 each other but not an outside network, and they can do so even when there is
469 no physical uplink on the associated NIC port.
470
471 To enable this feature, the user should pass a ``devargs`` parameter to the
472 EAL, for example::
473
474     -w 84:00.0,enable_floating_veb=1
475
476 In this configuration the PMD will use the floating VEB feature for all the
477 VFs created by this PF device.
478
479 Alternatively, the user can specify which VFs need to connect to this floating
480 VEB using the ``floating_veb_list`` argument::
481
482     -w 84:00.0,enable_floating_veb=1,floating_veb_list=1;3-4
483
484 In this example ``VF1``, ``VF3`` and ``VF4`` connect to the floating VEB,
485 while other VFs connect to the normal VEB.
486
487 The current implementation only supports one floating VEB and one regular
488 VEB. VFs can connect to a floating VEB or a regular VEB according to the
489 configuration passed on the EAL command line.
490
491 The floating VEB functionality requires a NIC firmware version of 5.0
492 or greater.
493
494 Dynamic Device Personalization (DDP)
495 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
496
497 The Intel® Ethernet 700 Series except for the Intel Ethernet Connection
498 X722 support a feature called "Dynamic Device Personalization (DDP)",
499 which is used to configure hardware by downloading a profile to support
500 protocols/filters which are not supported by default. The DDP
501 functionality requires a NIC firmware version of 6.0 or greater.
502
503 Current implementation supports GTP-C/GTP-U/PPPoE/PPPoL2TP/ESP,
504 steering can be used with rte_flow API.
505
506 GTPv1 package is released, and it can be downloaded from
507 https://downloadcenter.intel.com/download/27587.
508
509 PPPoE package is released, and it can be downloaded from
510 https://downloadcenter.intel.com/download/28040.
511
512 ESP-AH package is not released yet.
513
514 Load a profile which supports GTP and store backup profile:
515
516 .. code-block:: console
517
518    testpmd> ddp add 0 ./gtp.pkgo,./backup.pkgo
519
520 Delete a GTP profile and restore backup profile:
521
522 .. code-block:: console
523
524    testpmd> ddp del 0 ./backup.pkgo
525
526 Get loaded DDP package info list:
527
528 .. code-block:: console
529
530    testpmd> ddp get list 0
531
532 Display information about a GTP profile:
533
534 .. code-block:: console
535
536    testpmd> ddp get info ./gtp.pkgo
537
538 Input set configuration
539 ~~~~~~~~~~~~~~~~~~~~~~~
540 Input set for any PCTYPE can be configured with user defined configuration,
541 For example, to use only 48bit prefix for IPv6 src address for IPv6 TCP RSS:
542
543 .. code-block:: console
544
545    testpmd> port config 0 pctype 43 hash_inset clear all
546    testpmd> port config 0 pctype 43 hash_inset set field 13
547    testpmd> port config 0 pctype 43 hash_inset set field 14
548    testpmd> port config 0 pctype 43 hash_inset set field 15
549
550 Queue region configuration
551 ~~~~~~~~~~~~~~~~~~~~~~~~~~~
552 The Intel® Ethernet 700 Series supports a feature of queue regions
553 configuration for RSS in the PF, so that different traffic classes or
554 different packet classification types can be separated to different
555 queues in different queue regions. There is an API for configuration
556 of queue regions in RSS with a command line. It can parse the parameters
557 of the region index, queue number, queue start index, user priority, traffic
558 classes and so on. Depending on commands from the command line, it will call
559 i40e private APIs and start the process of setting or flushing the queue
560 region configuration. As this feature is specific for i40e only private
561 APIs are used. These new ``test_pmd`` commands are as shown below. For
562 details please refer to :doc:`../testpmd_app_ug/index`.
563
564 .. code-block:: console
565
566    testpmd> set port (port_id) queue-region region_id (value) \
567                 queue_start_index (value) queue_num (value)
568    testpmd> set port (port_id) queue-region region_id (value) flowtype (value)
569    testpmd> set port (port_id) queue-region UP (value) region_id (value)
570    testpmd> set port (port_id) queue-region flush (on|off)
571    testpmd> show port (port_id) queue-region
572
573 Generic flow API
574 ~~~~~~~~~~~~~~~~~~~
575
576 - ``RSS Flow``
577
578   RSS Flow supports to set hash input set, hash function, enable hash
579   and configure queue region.
580   For example:
581   Configure queue region as queue 0, 1, 2, 3.
582
583   .. code-block:: console
584
585     testpmd> flow create 0 ingress pattern end actions rss types end \
586       queues 0 1 2 3 end / end
587
588   Enable hash and set input set for ipv4-tcp.
589
590   .. code-block:: console
591
592     testpmd> flow create 0 ingress pattern eth / ipv4 / tcp / end \
593       actions rss types ipv4-tcp l3-src-only end queues end / end
594
595   Set symmetric hash enable for flow type ipv4-tcp.
596
597   .. code-block:: console
598
599     testpmd> flow create 0 ingress pattern eth / ipv4 / tcp / end \
600       actions rss types ipv4-tcp end queues end func symmetric_toeplitz / end
601
602   Set hash function as simple xor.
603
604   .. code-block:: console
605
606     testpmd> flow create 0 ingress pattern end actions rss types end \
607       queues end func simple_xor / end
608
609 Limitations or Known issues
610 ---------------------------
611
612 MPLS packet classification
613 ~~~~~~~~~~~~~~~~~~~~~~~~~~
614
615 For firmware versions prior to 5.0, MPLS packets are not recognized by the NIC.
616 The L2 Payload flow type in flow director can be used to classify MPLS packet
617 by using a command in testpmd like:
618
619    testpmd> flow_director_filter 0 mode IP add flow l2_payload ether \
620             0x8847 flexbytes () fwd pf queue <N> fd_id <M>
621
622 With the NIC firmware version 5.0 or greater, some limited MPLS support
623 is added: Native MPLS (MPLS in Ethernet) skip is implemented, while no
624 new packet type, no classification or offload are possible. With this change,
625 L2 Payload flow type in flow director cannot be used to classify MPLS packet
626 as with previous firmware versions. Meanwhile, the Ethertype filter can be
627 used to classify MPLS packet by using a command in testpmd like:
628
629    testpmd> ethertype_filter 0 add mac_ignr 00:00:00:00:00:00 ethertype \
630             0x8847 fwd queue <M>
631
632 16 Byte RX Descriptor setting on DPDK VF
633 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
634
635 Currently the VF's RX descriptor mode is decided by PF. There's no PF-VF
636 interface for VF to request the RX descriptor mode, also no interface to notify
637 VF its own RX descriptor mode.
638 For all available versions of the i40e driver, these drivers don't support 16
639 byte RX descriptor. If the Linux i40e kernel driver is used as host driver,
640 while DPDK i40e PMD is used as the VF driver, DPDK cannot choose 16 byte receive
641 descriptor. The reason is that the RX descriptor is already set to 32 byte by
642 the i40e kernel driver. That is to say, user should keep
643 ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC=n`` in config file.
644 In the future, if the Linux i40e driver supports 16 byte RX descriptor, user
645 should make sure the DPDK VF uses the same RX descriptor mode, 16 byte or 32
646 byte, as the PF driver.
647
648 The same rule for DPDK PF + DPDK VF. The PF and VF should use the same RX
649 descriptor mode. Or the VF RX will not work.
650
651 Receive packets with Ethertype 0x88A8
652 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
653
654 Due to the FW limitation, PF can receive packets with Ethertype 0x88A8
655 only when floating VEB is disabled.
656
657 Incorrect Rx statistics when packet is oversize
658 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
659
660 When a packet is over maximum frame size, the packet is dropped.
661 However, the Rx statistics, when calling `rte_eth_stats_get` incorrectly
662 shows it as received.
663
664 VF & TC max bandwidth setting
665 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
666
667 The per VF max bandwidth and per TC max bandwidth cannot be enabled in parallel.
668 The behavior is different when handling per VF and per TC max bandwidth setting.
669 When enabling per VF max bandwidth, SW will check if per TC max bandwidth is
670 enabled. If so, return failure.
671 When enabling per TC max bandwidth, SW will check if per VF max bandwidth
672 is enabled. If so, disable per VF max bandwidth and continue with per TC max
673 bandwidth setting.
674
675 TC TX scheduling mode setting
676 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
677
678 There are 2 TX scheduling modes for TCs, round robin and strict priority mode.
679 If a TC is set to strict priority mode, it can consume unlimited bandwidth.
680 It means if APP has set the max bandwidth for that TC, it comes to no
681 effect.
682 It's suggested to set the strict priority mode for a TC that is latency
683 sensitive but no consuming much bandwidth.
684
685 VF performance is impacted by PCI extended tag setting
686 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
687
688 To reach maximum NIC performance in the VF the PCI extended tag must be
689 enabled. The DPDK i40e PF driver will set this feature during initialization,
690 but the kernel PF driver does not. So when running traffic on a VF which is
691 managed by the kernel PF driver, a significant NIC performance downgrade has
692 been observed (for 64 byte packets, there is about 25% line-rate downgrade for
693 a 25GbE device and about 35% for a 40GbE device).
694
695 For kernel version >= 4.11, the kernel's PCI driver will enable the extended
696 tag if it detects that the device supports it. So by default, this is not an
697 issue. For kernels <= 4.11 or when the PCI extended tag is disabled it can be
698 enabled using the steps below.
699
700 #. Get the current value of the PCI configure register::
701
702       setpci -s <XX:XX.X> a8.w
703
704 #. Set bit 8::
705
706       value = value | 0x100
707
708 #. Set the PCI configure register with new value::
709
710       setpci -s <XX:XX.X> a8.w=<value>
711
712 Vlan strip of VF
713 ~~~~~~~~~~~~~~~~
714
715 The VF vlan strip function is only supported in the i40e kernel driver >= 2.1.26.
716
717 DCB function
718 ~~~~~~~~~~~~
719
720 DCB works only when RSS is enabled.
721
722 Global configuration warning
723 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
724
725 I40E PMD will set some global registers to enable some function or set some
726 configure. Then when using different ports of the same NIC with Linux kernel
727 and DPDK, the port with Linux kernel will be impacted by the port with DPDK.
728 For example, register I40E_GL_SWT_L2TAGCTRL is used to control L2 tag, i40e
729 PMD uses I40E_GL_SWT_L2TAGCTRL to set vlan TPID. If setting TPID in port A
730 with DPDK, then the configuration will also impact port B in the NIC with
731 kernel driver, which don't want to use the TPID.
732 So PMD reports warning to clarify what is changed by writing global register.
733
734 High Performance of Small Packets on 40GbE NIC
735 ----------------------------------------------
736
737 As there might be firmware fixes for performance enhancement in latest version
738 of firmware image, the firmware update might be needed for getting high performance.
739 Check the Intel support website for the latest firmware updates.
740 Users should consult the release notes specific to a DPDK release to identify
741 the validated firmware version for a NIC using the i40e driver.
742
743 Use 16 Bytes RX Descriptor Size
744 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
745
746 As i40e PMD supports both 16 and 32 bytes RX descriptor sizes, and 16 bytes size can provide helps to high performance of small packets.
747 Configuration of ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` in config files can be changed to use 16 bytes size RX descriptors.
748
749 Example of getting best performance with l3fwd example
750 ------------------------------------------------------
751
752 The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with a
753 server with Intel Xeon processors and Intel Ethernet CNA XL710.
754
755 The example scenario is to get best performance with two Intel Ethernet CNA XL710 40GbE ports.
756 See :numref:`figure_intel_perf_test_setup` for the performance test setup.
757
758 .. _figure_intel_perf_test_setup:
759
760 .. figure:: img/intel_perf_test_setup.*
761
762    Performance Test Setup
763
764
765 1. Add two Intel Ethernet CNA XL710 to the platform, and use one port per card to get best performance.
766    The reason for using two NICs is to overcome a PCIe v3.0 limitation since it cannot provide 80GbE bandwidth
767    for two 40GbE ports, but two different PCIe v3.0 x8 slot can.
768    Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
769
770       82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
771       85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
772
773 2. Connect the ports to the traffic generator. For high speed testing, it's best to use a hardware traffic generator.
774
775 3. Check the PCI devices numa node (socket id) and get the cores number on the exact socket id.
776    In this case, ``82:00.0`` and ``85:00.0`` are both in socket 1, and the cores on socket 1 in the referenced platform
777    are 18-35 and 54-71.
778    Note: Don't use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical
779    cores from different cores (e.g core18 and core19).
780
781 4. Bind these two ports to igb_uio.
782
783 5. As to Intel Ethernet CNA XL710 40GbE port, we need at least two queue pairs to achieve best performance, then two queues per port
784    will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
785
786 6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
787    Compile the ``l3fwd sample`` with the default lpm mode.
788
789 7. The command line of running l3fwd would be something like the following::
790
791       ./l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \
792               -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
793
794    This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
795    core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
796
797 8. Configure the traffic at a traffic generator.
798
799    * Start creating a stream on packet generator.
800
801    * Set the Ethernet II type to 0x0800.
802
803 Tx bytes affected by the link status change
804 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
805
806 For firmware versions prior to 6.01 for X710 series and 3.33 for X722 series, the tx_bytes statistics data is affected by
807 the link down event. Each time the link status changes to down, the tx_bytes decreases 110 bytes.