doc: fix driver names
[dpdk.git] / doc / guides / nics / i40e.rst
1 ..  SPDX-License-Identifier: BSD-3-Clause
2     Copyright(c) 2016 Intel Corporation.
3
4 I40E Poll Mode Driver
5 ======================
6
7 The i40e PMD (**librte_net_i40e**) provides poll mode driver support for
8 10/25/40 Gbps Intel® Ethernet 700 Series Network Adapters based on
9 the Intel Ethernet Controller X710/XL710/XXV710 and Intel Ethernet
10 Connection X722 (only support part of features).
11
12
13 Features
14 --------
15
16 Features of the i40e PMD are:
17
18 - Multiple queues for TX and RX
19 - Receiver Side Scaling (RSS)
20 - MAC/VLAN filtering
21 - Packet type information
22 - Flow director
23 - Cloud filter
24 - Checksum offload
25 - VLAN/QinQ stripping and inserting
26 - TSO offload
27 - Promiscuous mode
28 - Multicast mode
29 - Port hardware statistics
30 - Jumbo frames
31 - Link state information
32 - Link flow control
33 - Mirror on port, VLAN and VSI
34 - Interrupt mode for RX
35 - Scattered and gather for TX and RX
36 - Vector Poll mode driver
37 - DCB
38 - VMDQ
39 - SR-IOV VF
40 - Hot plug
41 - IEEE1588/802.1AS timestamping
42 - VF Daemon (VFD) - EXPERIMENTAL
43 - Dynamic Device Personalization (DDP)
44 - Queue region configuration
45 - Virtual Function Port Representors
46 - Malicious Device Drive event catch and notify
47 - Generic flow API
48
49 Prerequisites
50 -------------
51
52 - Identifying your adapter using `Intel Support
53   <http://www.intel.com/support>`_ and get the latest NVM/FW images.
54
55 - Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
56
57 - To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms"
58   section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
59
60 - Upgrade the NVM/FW version following the `Intel® Ethernet NVM Update Tool Quick Usage Guide for Linux
61   <https://www-ssl.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-linux-usage-guide.html>`_ and `Intel® Ethernet NVM Update Tool: Quick Usage Guide for EFI <https://www.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-efi-usage-guide.html>`_ if needed.
62
63 - For information about supported media, please refer to this document: `Intel® Ethernet Controller X710/XXV710/XL710 Feature Support Matrix
64   <http://www.intel.com/content/dam/www/public/us/en/documents/release-notes/xl710-ethernet-controller-feature-matrix.pdf>`_.
65
66    .. Note::
67
68       * Some adapters based on the Intel(R) Ethernet Controller 700 Series only
69         support Intel Ethernet Optics modules. On these adapters, other modules are not
70         supported and will not function.
71
72       * For connections based on Intel(R) Ethernet Controller 700 Series,
73         support is dependent on your system board. Please see your vendor for details.
74
75       * In all cases Intel recommends using Intel Ethernet Optics; other modules
76         may function but are not validated by Intel. Contact Intel for supported media types.
77
78 Recommended Matching List
79 -------------------------
80
81 It is highly recommended to upgrade the i40e kernel driver and firmware to
82 avoid the compatibility issues with i40e PMD. Here is the suggested matching
83 list which has been tested and verified. The detailed information can refer
84 to chapter Tested Platforms/Tested NICs in release notes.
85
86 For X710/XL710/XXV710,
87
88    +--------------+-----------------------+------------------+
89    | DPDK version | Kernel driver version | Firmware version |
90    +==============+=======================+==================+
91    |    20.08     |         2.12.6        |       7.30       |
92    +--------------+-----------------------+------------------+
93    |    20.05     |         2.11.27       |       7.30       |
94    +--------------+-----------------------+------------------+
95    |    20.02     |         2.10.19       |       7.20       |
96    +--------------+-----------------------+------------------+
97    |    19.11     |         2.9.21        |       7.00       |
98    +--------------+-----------------------+------------------+
99    |    19.08     |         2.8.43        |       7.00       |
100    +--------------+-----------------------+------------------+
101    |    19.05     |         2.7.29        |       6.80       |
102    +--------------+-----------------------+------------------+
103    |    19.02     |         2.7.26        |       6.80       |
104    +--------------+-----------------------+------------------+
105    |    18.11     |         2.4.6         |       6.01       |
106    +--------------+-----------------------+------------------+
107    |    18.08     |         2.4.6         |       6.01       |
108    +--------------+-----------------------+------------------+
109    |    18.05     |         2.4.6         |       6.01       |
110    +--------------+-----------------------+------------------+
111    |    18.02     |         2.4.3         |       6.01       |
112    +--------------+-----------------------+------------------+
113    |    17.11     |         2.1.26        |       6.01       |
114    +--------------+-----------------------+------------------+
115    |    17.08     |         2.0.19        |       6.01       |
116    +--------------+-----------------------+------------------+
117    |    17.05     |         1.5.23        |       5.05       |
118    +--------------+-----------------------+------------------+
119    |    17.02     |         1.5.23        |       5.05       |
120    +--------------+-----------------------+------------------+
121    |    16.11     |         1.5.23        |       5.05       |
122    +--------------+-----------------------+------------------+
123    |    16.07     |         1.4.25        |       5.04       |
124    +--------------+-----------------------+------------------+
125    |    16.04     |         1.4.25        |       5.02       |
126    +--------------+-----------------------+------------------+
127
128
129 For X722,
130
131    +--------------+-----------------------+------------------+
132    | DPDK version | Kernel driver version | Firmware version |
133    +==============+=======================+==================+
134    |    20.08     |         2.12.6        |       4.11       |
135    +--------------+-----------------------+------------------+
136    |    20.05     |         2.11.27       |       4.11       |
137    +--------------+-----------------------+------------------+
138    |    20.02     |         2.10.19       |       4.11       |
139    +--------------+-----------------------+------------------+
140    |    19.11     |         2.9.21        |       4.10       |
141    +--------------+-----------------------+------------------+
142    |    19.08     |         2.9.21        |       4.10       |
143    +--------------+-----------------------+------------------+
144    |    19.05     |         2.7.29        |       3.33       |
145    +--------------+-----------------------+------------------+
146    |    19.02     |         2.7.26        |       3.33       |
147    +--------------+-----------------------+------------------+
148    |    18.11     |         2.4.6         |       3.33       |
149    +--------------+-----------------------+------------------+
150
151
152 Pre-Installation Configuration
153 ------------------------------
154
155 Config File Options
156 ~~~~~~~~~~~~~~~~~~~
157
158 The following options can be modified in the ``config/rte_config.h`` file.
159
160 - ``RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
161
162   Number of queues reserved for PF.
163
164 - ``RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
165
166   Number of queues reserved for each VMDQ Pool.
167
168 Runtime Config Options
169 ~~~~~~~~~~~~~~~~~~~~~~
170
171 - ``Reserved number of Queues per VF`` (default ``4``)
172
173   The number of reserved queue per VF is determined by its host PF. If the
174   PCI address of an i40e PF is aaaa:bb.cc, the number of reserved queues per
175   VF can be configured with EAL parameter like -w aaaa:bb.cc,queue-num-per-vf=n.
176   The value n can be 1, 2, 4, 8 or 16. If no such parameter is configured, the
177   number of reserved queues per VF is 4 by default. If VF request more than
178   reserved queues per VF, PF will able to allocate max to 16 queues after a VF
179   reset.
180
181
182 - ``Support multiple driver`` (default ``disable``)
183
184   There was a multiple driver support issue during use of 700 series Ethernet
185   Adapter with both Linux kernel and DPDK PMD. To fix this issue, ``devargs``
186   parameter ``support-multi-driver`` is introduced, for example::
187
188     -w 84:00.0,support-multi-driver=1
189
190   With the above configuration, DPDK PMD will not change global registers, and
191   will switch PF interrupt from IntN to Int0 to avoid interrupt conflict between
192   DPDK and Linux Kernel.
193
194 - ``Support VF Port Representor`` (default ``not enabled``)
195
196   The i40e PF PMD supports the creation of VF port representors for the control
197   and monitoring of i40e virtual function devices. Each port representor
198   corresponds to a single virtual function of that device. Using the ``devargs``
199   option ``representor`` the user can specify which virtual functions to create
200   port representors for on initialization of the PF PMD by passing the VF IDs of
201   the VFs which are required.::
202
203   -w DBDF,representor=[0,1,4]
204
205   Currently hot-plugging of representor ports is not supported so all required
206   representors must be specified on the creation of the PF.
207
208 - ``Use latest supported vector`` (default ``disable``)
209
210   Latest supported vector path may not always get the best perf so vector path was
211   recommended to use only on later platform. But users may want the latest vector path
212   since it can get better perf in some real work loading cases. So ``devargs`` param
213   ``use-latest-supported-vec`` is introduced, for example::
214
215   -w 84:00.0,use-latest-supported-vec=1
216
217 - ``Enable validation for VF message`` (default ``not enabled``)
218
219   The PF counts messages from each VF. If in any period of seconds the message
220   statistic from a VF exceeds maximal limitation, the PF will ignore any new message
221   from that VF for some seconds.
222   Format -- "maximal-message@period-seconds:ignore-seconds"
223   For example::
224
225   -w 84:00.0,vf_msg_cfg=80@120:180
226
227 Vector RX Pre-conditions
228 ~~~~~~~~~~~~~~~~~~~~~~~~
229 For Vector RX it is assumed that the number of descriptor rings will be a power
230 of 2. With this pre-condition, the ring pointer can easily scroll back to the
231 head after hitting the tail without a conditional check. In addition Vector RX
232 can use this assumption to do a bit mask using ``ring_size - 1``.
233
234 Driver compilation and testing
235 ------------------------------
236
237 Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
238 for details.
239
240
241 SR-IOV: Prerequisites and sample Application Notes
242 --------------------------------------------------
243
244 #. Load the kernel module:
245
246    .. code-block:: console
247
248       modprobe i40e
249
250    Check the output in dmesg:
251
252    .. code-block:: console
253
254       i40e 0000:83:00.1 ens802f0: renamed from eth0
255
256 #. Bring up the PF ports:
257
258    .. code-block:: console
259
260       ifconfig ens802f0 up
261
262 #. Create VF device(s):
263
264    Echo the number of VFs to be created into the ``sriov_numvfs`` sysfs entry
265    of the parent PF.
266
267    Example:
268
269    .. code-block:: console
270
271       echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
272
273
274 #. Assign VF MAC address:
275
276    Assign MAC address to the VF using iproute2 utility. The syntax is:
277
278    .. code-block:: console
279
280       ip link set <PF netdev id> vf <VF id> mac <macaddr>
281
282    Example:
283
284    .. code-block:: console
285
286       ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0
287
288 #. Assign VF to VM, and bring up the VM.
289    Please see the documentation for the *I40E/IXGBE/IGB Virtual Function Driver*.
290
291 #. Running testpmd:
292
293    Follow instructions available in the document
294    :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
295    to run testpmd.
296
297    Example output:
298
299    .. code-block:: console
300
301       ...
302       EAL: PCI device 0000:83:00.0 on NUMA socket 1
303       EAL: probe driver: 8086:1572 rte_i40e_pmd
304       EAL: PCI memory mapped at 0x7f7f80000000
305       EAL: PCI memory mapped at 0x7f7f80800000
306       PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a
307       Interactive-mode selected
308       Configuring Port 0 (socket 0)
309       ...
310
311       PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are
312       satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0.
313
314       ...
315       Port 0: 68:05:CA:26:85:84
316       Checking link statuses...
317       Port 0 Link Up - speed 10000 Mbps - full-duplex
318       Done
319
320       testpmd>
321
322
323 Sample Application Notes
324 ------------------------
325
326 Vlan filter
327 ~~~~~~~~~~~
328
329 Vlan filter only works when Promiscuous mode is off.
330
331 To start ``testpmd``, and add vlan 10 to port 0:
332
333 .. code-block:: console
334
335     ./<build_dir>/app/dpdk-testpmd -l 0-15 -n 4 -- -i --forward-mode=mac
336     ...
337
338     testpmd> set promisc 0 off
339     testpmd> rx_vlan add 10 0
340
341
342 Flow Director
343 ~~~~~~~~~~~~~
344
345 The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
346 The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload.
347
348 The default input set of each flow type is::
349
350    ipv4-other : src_ip_address, dst_ip_address
351    ipv4-frag  : src_ip_address, dst_ip_address
352    ipv4-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
353    ipv4-udp   : src_ip_address, dst_ip_address, src_port, dst_port
354    ipv4-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
355                 verification_tag
356    ipv6-other : src_ip_address, dst_ip_address
357    ipv6-frag  : src_ip_address, dst_ip_address
358    ipv6-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
359    ipv6-udp   : src_ip_address, dst_ip_address, src_port, dst_port
360    ipv6-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
361                 verification_tag
362    l2_payload : ether_type
363
364 The flex payload is selected from offset 0 to 15 of packet's payload by default, while it is masked out from matching.
365
366 Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``:
367
368 .. code-block:: console
369
370    ./<build_dir>/app/dpdk-testpmd -l 0-15 -n 4 -- -i --disable-rss \
371                  --pkt-filter-mode=perfect --rxq=8 --txq=8 --nb-cores=8 \
372                  --nb-ports=1
373
374 Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1:
375
376 .. code-block:: console
377
378    testpmd> flow_director_filter 0 mode IP add flow ipv4-udp  \
379             src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \
380             fwd pf queue 1 fd_id 1
381
382 Check the flow director status:
383
384 .. code-block:: console
385
386    testpmd> show port fdir 0
387
388    ######################## FDIR infos for port 0      ####################
389      MODE:   PERFECT
390      SUPPORTED FLOW TYPE:  ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other
391                            ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other
392                            l2_payload
393      FLEX PAYLOAD INFO:
394      max_len:       16          payload_limit: 480
395      payload_unit:  2           payload_seg:   3
396      bitmask_unit:  2           bitmask_num:   2
397      MASK:
398        vlan_tci: 0x0000,
399        src_ipv4: 0x00000000,
400        dst_ipv4: 0x00000000,
401        src_port: 0x0000,
402        dst_port: 0x0000
403        src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000,
404        dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000
405      FLEX PAYLOAD SRC OFFSET:
406        L2_PAYLOAD:    0      1      2      3      4      5      6  ...
407        L3_PAYLOAD:    0      1      2      3      4      5      6  ...
408        L4_PAYLOAD:    0      1      2      3      4      5      6  ...
409      FLEX MASK CFG:
410        ipv4-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
411        ipv4-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
412        ipv4-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
413        ipv4-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
414        ipv4-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
415        ipv6-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
416        ipv6-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
417        ipv6-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
418        ipv6-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
419        ipv6-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
420        l2_payload:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
421      guarant_count: 1           best_count:    0
422      guarant_space: 512         best_space:    7168
423      collision:     0           free:          0
424      maxhash:       0           maxlen:        0
425      add:           0           remove:        0
426      f_add:         0           f_remove:      0
427
428
429 Delete all flow director rules on a port:
430
431 .. code-block:: console
432
433    testpmd> flush_flow_director 0
434
435 Floating VEB
436 ~~~~~~~~~~~~~
437
438 The Intel® Ethernet 700 Series support a feature called
439 "Floating VEB".
440
441 A Virtual Ethernet Bridge (VEB) is an IEEE Edge Virtual Bridging (EVB) term
442 for functionality that allows local switching between virtual endpoints within
443 a physical endpoint and also with an external bridge/network.
444
445 A "Floating" VEB doesn't have an uplink connection to the outside world so all
446 switching is done internally and remains within the host. As such, this
447 feature provides security benefits.
448
449 In addition, a Floating VEB overcomes a limitation of normal VEBs where they
450 cannot forward packets when the physical link is down. Floating VEBs don't need
451 to connect to the NIC port so they can still forward traffic from VF to VF
452 even when the physical link is down.
453
454 Therefore, with this feature enabled VFs can be limited to communicating with
455 each other but not an outside network, and they can do so even when there is
456 no physical uplink on the associated NIC port.
457
458 To enable this feature, the user should pass a ``devargs`` parameter to the
459 EAL, for example::
460
461     -w 84:00.0,enable_floating_veb=1
462
463 In this configuration the PMD will use the floating VEB feature for all the
464 VFs created by this PF device.
465
466 Alternatively, the user can specify which VFs need to connect to this floating
467 VEB using the ``floating_veb_list`` argument::
468
469     -w 84:00.0,enable_floating_veb=1,floating_veb_list=1;3-4
470
471 In this example ``VF1``, ``VF3`` and ``VF4`` connect to the floating VEB,
472 while other VFs connect to the normal VEB.
473
474 The current implementation only supports one floating VEB and one regular
475 VEB. VFs can connect to a floating VEB or a regular VEB according to the
476 configuration passed on the EAL command line.
477
478 The floating VEB functionality requires a NIC firmware version of 5.0
479 or greater.
480
481 Dynamic Device Personalization (DDP)
482 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
483
484 The Intel® Ethernet 700 Series except for the Intel Ethernet Connection
485 X722 support a feature called "Dynamic Device Personalization (DDP)",
486 which is used to configure hardware by downloading a profile to support
487 protocols/filters which are not supported by default. The DDP
488 functionality requires a NIC firmware version of 6.0 or greater.
489
490 Current implementation supports GTP-C/GTP-U/PPPoE/PPPoL2TP/ESP,
491 steering can be used with rte_flow API.
492
493 GTPv1 package is released, and it can be downloaded from
494 https://downloadcenter.intel.com/download/27587.
495
496 PPPoE package is released, and it can be downloaded from
497 https://downloadcenter.intel.com/download/28040.
498
499 ESP-AH package is released, and it can be downloaded from
500 https://downloadcenter.intel.com/download/29446.
501
502 Load a profile which supports GTP and store backup profile:
503
504 .. code-block:: console
505
506    testpmd> ddp add 0 ./gtp.pkgo,./backup.pkgo
507
508 Delete a GTP profile and restore backup profile:
509
510 .. code-block:: console
511
512    testpmd> ddp del 0 ./backup.pkgo
513
514 Get loaded DDP package info list:
515
516 .. code-block:: console
517
518    testpmd> ddp get list 0
519
520 Display information about a GTP profile:
521
522 .. code-block:: console
523
524    testpmd> ddp get info ./gtp.pkgo
525
526 Input set configuration
527 ~~~~~~~~~~~~~~~~~~~~~~~
528 Input set for any PCTYPE can be configured with user defined configuration,
529 For example, to use only 48bit prefix for IPv6 src address for IPv6 TCP RSS:
530
531 .. code-block:: console
532
533    testpmd> port config 0 pctype 43 hash_inset clear all
534    testpmd> port config 0 pctype 43 hash_inset set field 13
535    testpmd> port config 0 pctype 43 hash_inset set field 14
536    testpmd> port config 0 pctype 43 hash_inset set field 15
537
538 Queue region configuration
539 ~~~~~~~~~~~~~~~~~~~~~~~~~~~
540 The Intel® Ethernet 700 Series supports a feature of queue regions
541 configuration for RSS in the PF, so that different traffic classes or
542 different packet classification types can be separated to different
543 queues in different queue regions. There is an API for configuration
544 of queue regions in RSS with a command line. It can parse the parameters
545 of the region index, queue number, queue start index, user priority, traffic
546 classes and so on. Depending on commands from the command line, it will call
547 i40e private APIs and start the process of setting or flushing the queue
548 region configuration. As this feature is specific for i40e only private
549 APIs are used. These new ``test_pmd`` commands are as shown below. For
550 details please refer to :doc:`../testpmd_app_ug/index`.
551
552 .. code-block:: console
553
554    testpmd> set port (port_id) queue-region region_id (value) \
555                 queue_start_index (value) queue_num (value)
556    testpmd> set port (port_id) queue-region region_id (value) flowtype (value)
557    testpmd> set port (port_id) queue-region UP (value) region_id (value)
558    testpmd> set port (port_id) queue-region flush (on|off)
559    testpmd> show port (port_id) queue-region
560
561 Generic flow API
562 ~~~~~~~~~~~~~~~~~~~
563
564 - ``RSS Flow``
565
566   RSS Flow supports to set hash input set, hash function, enable hash
567   and configure queue region.
568   For example:
569   Configure queue region as queue 0, 1, 2, 3.
570
571   .. code-block:: console
572
573     testpmd> flow create 0 ingress pattern end actions rss types end \
574       queues 0 1 2 3 end / end
575
576   Enable hash and set input set for ipv4-tcp.
577
578   .. code-block:: console
579
580     testpmd> flow create 0 ingress pattern eth / ipv4 / tcp / end \
581       actions rss types ipv4-tcp l3-src-only end queues end / end
582
583   Set symmetric hash enable for flow type ipv4-tcp.
584
585   .. code-block:: console
586
587     testpmd> flow create 0 ingress pattern eth / ipv4 / tcp / end \
588       actions rss types ipv4-tcp end queues end func symmetric_toeplitz / end
589
590   Set hash function as simple xor.
591
592   .. code-block:: console
593
594     testpmd> flow create 0 ingress pattern end actions rss types end \
595       queues end func simple_xor / end
596
597 Limitations or Known issues
598 ---------------------------
599
600 MPLS packet classification
601 ~~~~~~~~~~~~~~~~~~~~~~~~~~
602
603 For firmware versions prior to 5.0, MPLS packets are not recognized by the NIC.
604 The L2 Payload flow type in flow director can be used to classify MPLS packet
605 by using a command in testpmd like:
606
607    testpmd> flow_director_filter 0 mode IP add flow l2_payload ether \
608             0x8847 flexbytes () fwd pf queue <N> fd_id <M>
609
610 With the NIC firmware version 5.0 or greater, some limited MPLS support
611 is added: Native MPLS (MPLS in Ethernet) skip is implemented, while no
612 new packet type, no classification or offload are possible. With this change,
613 L2 Payload flow type in flow director cannot be used to classify MPLS packet
614 as with previous firmware versions. Meanwhile, the Ethertype filter can be
615 used to classify MPLS packet by using a command in testpmd like:
616
617    testpmd> ethertype_filter 0 add mac_ignr 00:00:00:00:00:00 ethertype \
618             0x8847 fwd queue <M>
619
620 16 Byte RX Descriptor setting on DPDK VF
621 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
622
623 Currently the VF's RX descriptor mode is decided by PF. There's no PF-VF
624 interface for VF to request the RX descriptor mode, also no interface to notify
625 VF its own RX descriptor mode.
626 For all available versions of the i40e driver, these drivers don't support 16
627 byte RX descriptor. If the Linux i40e kernel driver is used as host driver,
628 while DPDK i40e PMD is used as the VF driver, DPDK cannot choose 16 byte receive
629 descriptor. The reason is that the RX descriptor is already set to 32 byte by
630 the i40e kernel driver.
631 In the future, if the Linux i40e driver supports 16 byte RX descriptor, user
632 should make sure the DPDK VF uses the same RX descriptor mode, 16 byte or 32
633 byte, as the PF driver.
634
635 The same rule for DPDK PF + DPDK VF. The PF and VF should use the same RX
636 descriptor mode. Or the VF RX will not work.
637
638 Receive packets with Ethertype 0x88A8
639 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
640
641 Due to the FW limitation, PF can receive packets with Ethertype 0x88A8
642 only when floating VEB is disabled.
643
644 Incorrect Rx statistics when packet is oversize
645 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
646
647 When a packet is over maximum frame size, the packet is dropped.
648 However, the Rx statistics, when calling `rte_eth_stats_get` incorrectly
649 shows it as received.
650
651 RX/TX statistics may be incorrect when register overflowed
652 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
653
654 The rx_bytes/tx_bytes statistics register is 48 bit length.
655 Although this limitation is enlarged to 64 bit length on the software side,
656 but there is no way to detect if the overflow occurred more than once.
657 So rx_bytes/tx_bytes statistics data is correct when statistics are
658 updated at least once between two overflows.
659
660 VF & TC max bandwidth setting
661 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
662
663 The per VF max bandwidth and per TC max bandwidth cannot be enabled in parallel.
664 The behavior is different when handling per VF and per TC max bandwidth setting.
665 When enabling per VF max bandwidth, SW will check if per TC max bandwidth is
666 enabled. If so, return failure.
667 When enabling per TC max bandwidth, SW will check if per VF max bandwidth
668 is enabled. If so, disable per VF max bandwidth and continue with per TC max
669 bandwidth setting.
670
671 TC TX scheduling mode setting
672 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
673
674 There are 2 TX scheduling modes for TCs, round robin and strict priority mode.
675 If a TC is set to strict priority mode, it can consume unlimited bandwidth.
676 It means if APP has set the max bandwidth for that TC, it comes to no
677 effect.
678 It's suggested to set the strict priority mode for a TC that is latency
679 sensitive but no consuming much bandwidth.
680
681 VF performance is impacted by PCI extended tag setting
682 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
683
684 To reach maximum NIC performance in the VF the PCI extended tag must be
685 enabled. The DPDK i40e PF driver will set this feature during initialization,
686 but the kernel PF driver does not. So when running traffic on a VF which is
687 managed by the kernel PF driver, a significant NIC performance downgrade has
688 been observed (for 64 byte packets, there is about 25% line-rate downgrade for
689 a 25GbE device and about 35% for a 40GbE device).
690
691 For kernel version >= 4.11, the kernel's PCI driver will enable the extended
692 tag if it detects that the device supports it. So by default, this is not an
693 issue. For kernels <= 4.11 or when the PCI extended tag is disabled it can be
694 enabled using the steps below.
695
696 #. Get the current value of the PCI configure register::
697
698       setpci -s <XX:XX.X> a8.w
699
700 #. Set bit 8::
701
702       value = value | 0x100
703
704 #. Set the PCI configure register with new value::
705
706       setpci -s <XX:XX.X> a8.w=<value>
707
708 Vlan strip of VF
709 ~~~~~~~~~~~~~~~~
710
711 The VF vlan strip function is only supported in the i40e kernel driver >= 2.1.26.
712
713 DCB function
714 ~~~~~~~~~~~~
715
716 DCB works only when RSS is enabled.
717
718 Global configuration warning
719 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
720
721 I40E PMD will set some global registers to enable some function or set some
722 configure. Then when using different ports of the same NIC with Linux kernel
723 and DPDK, the port with Linux kernel will be impacted by the port with DPDK.
724 For example, register I40E_GL_SWT_L2TAGCTRL is used to control L2 tag, i40e
725 PMD uses I40E_GL_SWT_L2TAGCTRL to set vlan TPID. If setting TPID in port A
726 with DPDK, then the configuration will also impact port B in the NIC with
727 kernel driver, which don't want to use the TPID.
728 So PMD reports warning to clarify what is changed by writing global register.
729
730 Cloud Filter
731 ~~~~~~~~~~~~
732
733 When programming cloud filters for IPv4/6_UDP/TCP/SCTP with SRC port only or DST port only,
734 it will make any cloud filter using inner_vlan or tunnel key invalid. Default configuration will be
735 recovered only by NIC core reset.
736
737 High Performance of Small Packets on 40GbE NIC
738 ----------------------------------------------
739
740 As there might be firmware fixes for performance enhancement in latest version
741 of firmware image, the firmware update might be needed for getting high performance.
742 Check the Intel support website for the latest firmware updates.
743 Users should consult the release notes specific to a DPDK release to identify
744 the validated firmware version for a NIC using the i40e driver.
745
746 Use 16 Bytes RX Descriptor Size
747 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
748
749 As i40e PMD supports both 16 and 32 bytes RX descriptor sizes, and 16 bytes size can provide helps to high performance of small packets.
750 In ``config/rte_config.h`` set the following to use 16 bytes size RX descriptors::
751
752    #define RTE_LIBRTE_I40E_16BYTE_RX_DESC 1
753
754 Input set requirement of each pctype for FDIR
755 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
756
757 Each PCTYPE can only have one specific FDIR input set at one time.
758 For example, if creating 2 rte_flow rules with different input set for one PCTYPE,
759 it will fail and return the info "Conflict with the first rule's input set",
760 which means the current rule's input set conflicts with the first rule's.
761 Remove the first rule if want to change the input set of the PCTYPE.
762
763 Example of getting best performance with l3fwd example
764 ------------------------------------------------------
765
766 The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with a
767 server with Intel Xeon processors and Intel Ethernet CNA XL710.
768
769 The example scenario is to get best performance with two Intel Ethernet CNA XL710 40GbE ports.
770 See :numref:`figure_intel_perf_test_setup` for the performance test setup.
771
772 .. _figure_intel_perf_test_setup:
773
774 .. figure:: img/intel_perf_test_setup.*
775
776    Performance Test Setup
777
778
779 1. Add two Intel Ethernet CNA XL710 to the platform, and use one port per card to get best performance.
780    The reason for using two NICs is to overcome a PCIe v3.0 limitation since it cannot provide 80GbE bandwidth
781    for two 40GbE ports, but two different PCIe v3.0 x8 slot can.
782    Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
783
784       82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
785       85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
786
787 2. Connect the ports to the traffic generator. For high speed testing, it's best to use a hardware traffic generator.
788
789 3. Check the PCI devices numa node (socket id) and get the cores number on the exact socket id.
790    In this case, ``82:00.0`` and ``85:00.0`` are both in socket 1, and the cores on socket 1 in the referenced platform
791    are 18-35 and 54-71.
792    Note: Don't use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical
793    cores from different cores (e.g core18 and core19).
794
795 4. Bind these two ports to igb_uio.
796
797 5. As to Intel Ethernet CNA XL710 40GbE port, we need at least two queue pairs to achieve best performance, then two queues per port
798    will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
799
800 6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
801    Compile the ``l3fwd sample`` with the default lpm mode.
802
803 7. The command line of running l3fwd would be something like the following::
804
805       ./dpdk-l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \
806               -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
807
808    This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
809    core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
810
811 8. Configure the traffic at a traffic generator.
812
813    * Start creating a stream on packet generator.
814
815    * Set the Ethernet II type to 0x0800.
816
817 Tx bytes affected by the link status change
818 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
819
820 For firmware versions prior to 6.01 for X710 series and 3.33 for X722 series, the tx_bytes statistics data is affected by
821 the link down event. Each time the link status changes to down, the tx_bytes decreases 110 bytes.