doc: update firmware/driver mapping table for i40e
[dpdk.git] / doc / guides / nics / i40e.rst
1 ..  SPDX-License-Identifier: BSD-3-Clause
2     Copyright(c) 2016 Intel Corporation.
3
4 I40E Poll Mode Driver
5 ======================
6
7 The i40e PMD (librte_pmd_i40e) provides poll mode driver support for
8 10/25/40 Gbps Intel® Ethernet 700 Series Network Adapters based on
9 the Intel Ethernet Controller X710/XL710/XXV710 and Intel Ethernet
10 Connection X722 (only support part of features).
11
12
13 Features
14 --------
15
16 Features of the i40e PMD are:
17
18 - Multiple queues for TX and RX
19 - Receiver Side Scaling (RSS)
20 - MAC/VLAN filtering
21 - Packet type information
22 - Flow director
23 - Cloud filter
24 - Checksum offload
25 - VLAN/QinQ stripping and inserting
26 - TSO offload
27 - Promiscuous mode
28 - Multicast mode
29 - Port hardware statistics
30 - Jumbo frames
31 - Link state information
32 - Link flow control
33 - Mirror on port, VLAN and VSI
34 - Interrupt mode for RX
35 - Scattered and gather for TX and RX
36 - Vector Poll mode driver
37 - DCB
38 - VMDQ
39 - SR-IOV VF
40 - Hot plug
41 - IEEE1588/802.1AS timestamping
42 - VF Daemon (VFD) - EXPERIMENTAL
43 - Dynamic Device Personalization (DDP)
44 - Queue region configuration
45 - Virtual Function Port Representors
46 - Malicious Device Drive event catch and notify
47 - Generic flow API
48
49 Prerequisites
50 -------------
51
52 - Identifying your adapter using `Intel Support
53   <http://www.intel.com/support>`_ and get the latest NVM/FW images.
54
55 - Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
56
57 - To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms"
58   section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
59
60 - Upgrade the NVM/FW version following the `Intel® Ethernet NVM Update Tool Quick Usage Guide for Linux
61   <https://www-ssl.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-linux-usage-guide.html>`_ and `Intel® Ethernet NVM Update Tool: Quick Usage Guide for EFI <https://www.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-efi-usage-guide.html>`_ if needed.
62
63 - For information about supported media, please refer to this document: `Intel® Ethernet Controller X710/XXV710/XL710 Feature Support Matrix
64   <http://www.intel.com/content/dam/www/public/us/en/documents/release-notes/xl710-ethernet-controller-feature-matrix.pdf>`_.
65
66    .. Note::
67
68       * Some adapters based on the Intel(R) Ethernet Controller 700 Series only
69         support Intel Ethernet Optics modules. On these adapters, other modules are not
70         supported and will not function.
71
72       * For connections based on Intel(R) Ethernet Controller 700 Series,
73         support is dependent on your system board. Please see your vendor for details.
74
75       * In all cases Intel recommends using Intel Ethernet Optics; other modules
76         may function but are not validated by Intel. Contact Intel for supported media types.
77
78 Recommended Matching List
79 -------------------------
80
81 It is highly recommended to upgrade the i40e kernel driver and firmware to
82 avoid the compatibility issues with i40e PMD. Here is the suggested matching
83 list which has been tested and verified. The detailed information can refer
84 to chapter Tested Platforms/Tested NICs in release notes.
85
86 For X710/XL710/XXV710,
87
88    +--------------+-----------------------+------------------+
89    | DPDK version | Kernel driver version | Firmware version |
90    +==============+=======================+==================+
91    |    20.05     |         2.11.27       |       7.30       |
92    +--------------+-----------------------+------------------+
93    |    20.02     |         2.10.19       |       7.20       |
94    +--------------+-----------------------+------------------+
95    |    19.11     |         2.9.21        |       7.00       |
96    +--------------+-----------------------+------------------+
97    |    19.08     |         2.8.43        |       7.00       |
98    +--------------+-----------------------+------------------+
99    |    19.05     |         2.7.29        |       6.80       |
100    +--------------+-----------------------+------------------+
101    |    19.02     |         2.7.26        |       6.80       |
102    +--------------+-----------------------+------------------+
103    |    18.11     |         2.4.6         |       6.01       |
104    +--------------+-----------------------+------------------+
105    |    18.08     |         2.4.6         |       6.01       |
106    +--------------+-----------------------+------------------+
107    |    18.05     |         2.4.6         |       6.01       |
108    +--------------+-----------------------+------------------+
109    |    18.02     |         2.4.3         |       6.01       |
110    +--------------+-----------------------+------------------+
111    |    17.11     |         2.1.26        |       6.01       |
112    +--------------+-----------------------+------------------+
113    |    17.08     |         2.0.19        |       6.01       |
114    +--------------+-----------------------+------------------+
115    |    17.05     |         1.5.23        |       5.05       |
116    +--------------+-----------------------+------------------+
117    |    17.02     |         1.5.23        |       5.05       |
118    +--------------+-----------------------+------------------+
119    |    16.11     |         1.5.23        |       5.05       |
120    +--------------+-----------------------+------------------+
121    |    16.07     |         1.4.25        |       5.04       |
122    +--------------+-----------------------+------------------+
123    |    16.04     |         1.4.25        |       5.02       |
124    +--------------+-----------------------+------------------+
125
126
127 For X722,
128
129    +--------------+-----------------------+------------------+
130    | DPDK version | Kernel driver version | Firmware version |
131    +==============+=======================+==================+
132    |    20.05     |         2.11.27       |       4.11       |
133    +--------------+-----------------------+------------------+
134    |    20.02     |         2.10.19       |       4.11       |
135    +--------------+-----------------------+------------------+
136    |    19.11     |         2.9.21        |       4.10       |
137    +--------------+-----------------------+------------------+
138    |    19.08     |         2.9.21        |       4.10       |
139    +--------------+-----------------------+------------------+
140    |    19.05     |         2.7.29        |       3.33       |
141    +--------------+-----------------------+------------------+
142    |    19.02     |         2.7.26        |       3.33       |
143    +--------------+-----------------------+------------------+
144    |    18.11     |         2.4.6         |       3.33       |
145    +--------------+-----------------------+------------------+
146
147
148 Pre-Installation Configuration
149 ------------------------------
150
151 Config File Options
152 ~~~~~~~~~~~~~~~~~~~
153
154 The following options can be modified in the ``config`` file.
155 Please note that enabling debugging options may affect system performance.
156
157 - ``CONFIG_RTE_LIBRTE_I40E_PMD`` (default ``y``)
158
159   Toggle compilation of the ``librte_pmd_i40e`` driver.
160
161 - ``CONFIG_RTE_LIBRTE_I40E_DEBUG_*`` (default ``n``)
162
163   Toggle display of generic debugging messages.
164
165 - ``CONFIG_RTE_LIBRTE_I40E_RX_ALLOW_BULK_ALLOC`` (default ``y``)
166
167   Toggle bulk allocation for RX.
168
169 - ``CONFIG_RTE_LIBRTE_I40E_INC_VECTOR`` (default ``n``)
170
171   Toggle the use of Vector PMD instead of normal RX/TX path.
172   To enable vPMD for RX, bulk allocation for Rx must be allowed.
173
174 - ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` (default ``n``)
175
176   Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte.
177
178 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
179
180   Number of queues reserved for PF.
181
182 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
183
184   Number of queues reserved for each VMDQ Pool.
185
186 Runtime Config Options
187 ~~~~~~~~~~~~~~~~~~~~~~
188
189 - ``Reserved number of Queues per VF`` (default ``4``)
190
191   The number of reserved queue per VF is determined by its host PF. If the
192   PCI address of an i40e PF is aaaa:bb.cc, the number of reserved queues per
193   VF can be configured with EAL parameter like -w aaaa:bb.cc,queue-num-per-vf=n.
194   The value n can be 1, 2, 4, 8 or 16. If no such parameter is configured, the
195   number of reserved queues per VF is 4 by default. If VF request more than
196   reserved queues per VF, PF will able to allocate max to 16 queues after a VF
197   reset.
198
199
200 - ``Support multiple driver`` (default ``disable``)
201
202   There was a multiple driver support issue during use of 700 series Ethernet
203   Adapter with both Linux kernel and DPDK PMD. To fix this issue, ``devargs``
204   parameter ``support-multi-driver`` is introduced, for example::
205
206     -w 84:00.0,support-multi-driver=1
207
208   With the above configuration, DPDK PMD will not change global registers, and
209   will switch PF interrupt from IntN to Int0 to avoid interrupt conflict between
210   DPDK and Linux Kernel.
211
212 - ``Support VF Port Representor`` (default ``not enabled``)
213
214   The i40e PF PMD supports the creation of VF port representors for the control
215   and monitoring of i40e virtual function devices. Each port representor
216   corresponds to a single virtual function of that device. Using the ``devargs``
217   option ``representor`` the user can specify which virtual functions to create
218   port representors for on initialization of the PF PMD by passing the VF IDs of
219   the VFs which are required.::
220
221   -w DBDF,representor=[0,1,4]
222
223   Currently hot-plugging of representor ports is not supported so all required
224   representors must be specified on the creation of the PF.
225
226 - ``Use latest supported vector`` (default ``disable``)
227
228   Latest supported vector path may not always get the best perf so vector path was
229   recommended to use only on later platform. But users may want the latest vector path
230   since it can get better perf in some real work loading cases. So ``devargs`` param
231   ``use-latest-supported-vec`` is introduced, for example::
232
233   -w 84:00.0,use-latest-supported-vec=1
234
235 - ``Enable validation for VF message`` (default ``not enabled``)
236
237   The PF counts messages from each VF. If in any period of seconds the message
238   statistic from a VF exceeds maximal limitation, the PF will ignore any new message
239   from that VF for some seconds.
240   Format -- "maximal-message@period-seconds:ignore-seconds"
241   For example::
242
243   -w 84:00.0,vf_msg_cfg=80@120:180
244
245 Vector RX Pre-conditions
246 ~~~~~~~~~~~~~~~~~~~~~~~~
247 For Vector RX it is assumed that the number of descriptor rings will be a power
248 of 2. With this pre-condition, the ring pointer can easily scroll back to the
249 head after hitting the tail without a conditional check. In addition Vector RX
250 can use this assumption to do a bit mask using ``ring_size - 1``.
251
252 Driver compilation and testing
253 ------------------------------
254
255 Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
256 for details.
257
258
259 SR-IOV: Prerequisites and sample Application Notes
260 --------------------------------------------------
261
262 #. Load the kernel module:
263
264    .. code-block:: console
265
266       modprobe i40e
267
268    Check the output in dmesg:
269
270    .. code-block:: console
271
272       i40e 0000:83:00.1 ens802f0: renamed from eth0
273
274 #. Bring up the PF ports:
275
276    .. code-block:: console
277
278       ifconfig ens802f0 up
279
280 #. Create VF device(s):
281
282    Echo the number of VFs to be created into the ``sriov_numvfs`` sysfs entry
283    of the parent PF.
284
285    Example:
286
287    .. code-block:: console
288
289       echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
290
291
292 #. Assign VF MAC address:
293
294    Assign MAC address to the VF using iproute2 utility. The syntax is:
295
296    .. code-block:: console
297
298       ip link set <PF netdev id> vf <VF id> mac <macaddr>
299
300    Example:
301
302    .. code-block:: console
303
304       ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0
305
306 #. Assign VF to VM, and bring up the VM.
307    Please see the documentation for the *I40E/IXGBE/IGB Virtual Function Driver*.
308
309 #. Running testpmd:
310
311    Follow instructions available in the document
312    :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
313    to run testpmd.
314
315    Example output:
316
317    .. code-block:: console
318
319       ...
320       EAL: PCI device 0000:83:00.0 on NUMA socket 1
321       EAL: probe driver: 8086:1572 rte_i40e_pmd
322       EAL: PCI memory mapped at 0x7f7f80000000
323       EAL: PCI memory mapped at 0x7f7f80800000
324       PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a
325       Interactive-mode selected
326       Configuring Port 0 (socket 0)
327       ...
328
329       PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are
330       satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0.
331
332       ...
333       Port 0: 68:05:CA:26:85:84
334       Checking link statuses...
335       Port 0 Link Up - speed 10000 Mbps - full-duplex
336       Done
337
338       testpmd>
339
340
341 Sample Application Notes
342 ------------------------
343
344 Vlan filter
345 ~~~~~~~~~~~
346
347 Vlan filter only works when Promiscuous mode is off.
348
349 To start ``testpmd``, and add vlan 10 to port 0:
350
351 .. code-block:: console
352
353     ./app/testpmd -l 0-15 -n 4 -- -i --forward-mode=mac
354     ...
355
356     testpmd> set promisc 0 off
357     testpmd> rx_vlan add 10 0
358
359
360 Flow Director
361 ~~~~~~~~~~~~~
362
363 The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
364 The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload.
365
366 The default input set of each flow type is::
367
368    ipv4-other : src_ip_address, dst_ip_address
369    ipv4-frag  : src_ip_address, dst_ip_address
370    ipv4-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
371    ipv4-udp   : src_ip_address, dst_ip_address, src_port, dst_port
372    ipv4-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
373                 verification_tag
374    ipv6-other : src_ip_address, dst_ip_address
375    ipv6-frag  : src_ip_address, dst_ip_address
376    ipv6-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
377    ipv6-udp   : src_ip_address, dst_ip_address, src_port, dst_port
378    ipv6-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
379                 verification_tag
380    l2_payload : ether_type
381
382 The flex payload is selected from offset 0 to 15 of packet's payload by default, while it is masked out from matching.
383
384 Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``:
385
386 .. code-block:: console
387
388    ./app/testpmd -l 0-15 -n 4 -- -i --disable-rss --pkt-filter-mode=perfect \
389                  --rxq=8 --txq=8 --nb-cores=8 --nb-ports=1
390
391 Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1:
392
393 .. code-block:: console
394
395    testpmd> flow_director_filter 0 mode IP add flow ipv4-udp  \
396             src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \
397             fwd pf queue 1 fd_id 1
398
399 Check the flow director status:
400
401 .. code-block:: console
402
403    testpmd> show port fdir 0
404
405    ######################## FDIR infos for port 0      ####################
406      MODE:   PERFECT
407      SUPPORTED FLOW TYPE:  ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other
408                            ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other
409                            l2_payload
410      FLEX PAYLOAD INFO:
411      max_len:       16          payload_limit: 480
412      payload_unit:  2           payload_seg:   3
413      bitmask_unit:  2           bitmask_num:   2
414      MASK:
415        vlan_tci: 0x0000,
416        src_ipv4: 0x00000000,
417        dst_ipv4: 0x00000000,
418        src_port: 0x0000,
419        dst_port: 0x0000
420        src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000,
421        dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000
422      FLEX PAYLOAD SRC OFFSET:
423        L2_PAYLOAD:    0      1      2      3      4      5      6  ...
424        L3_PAYLOAD:    0      1      2      3      4      5      6  ...
425        L4_PAYLOAD:    0      1      2      3      4      5      6  ...
426      FLEX MASK CFG:
427        ipv4-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
428        ipv4-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
429        ipv4-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
430        ipv4-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
431        ipv4-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
432        ipv6-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
433        ipv6-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
434        ipv6-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
435        ipv6-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
436        ipv6-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
437        l2_payload:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
438      guarant_count: 1           best_count:    0
439      guarant_space: 512         best_space:    7168
440      collision:     0           free:          0
441      maxhash:       0           maxlen:        0
442      add:           0           remove:        0
443      f_add:         0           f_remove:      0
444
445
446 Delete all flow director rules on a port:
447
448 .. code-block:: console
449
450    testpmd> flush_flow_director 0
451
452 Floating VEB
453 ~~~~~~~~~~~~~
454
455 The Intel® Ethernet 700 Series support a feature called
456 "Floating VEB".
457
458 A Virtual Ethernet Bridge (VEB) is an IEEE Edge Virtual Bridging (EVB) term
459 for functionality that allows local switching between virtual endpoints within
460 a physical endpoint and also with an external bridge/network.
461
462 A "Floating" VEB doesn't have an uplink connection to the outside world so all
463 switching is done internally and remains within the host. As such, this
464 feature provides security benefits.
465
466 In addition, a Floating VEB overcomes a limitation of normal VEBs where they
467 cannot forward packets when the physical link is down. Floating VEBs don't need
468 to connect to the NIC port so they can still forward traffic from VF to VF
469 even when the physical link is down.
470
471 Therefore, with this feature enabled VFs can be limited to communicating with
472 each other but not an outside network, and they can do so even when there is
473 no physical uplink on the associated NIC port.
474
475 To enable this feature, the user should pass a ``devargs`` parameter to the
476 EAL, for example::
477
478     -w 84:00.0,enable_floating_veb=1
479
480 In this configuration the PMD will use the floating VEB feature for all the
481 VFs created by this PF device.
482
483 Alternatively, the user can specify which VFs need to connect to this floating
484 VEB using the ``floating_veb_list`` argument::
485
486     -w 84:00.0,enable_floating_veb=1,floating_veb_list=1;3-4
487
488 In this example ``VF1``, ``VF3`` and ``VF4`` connect to the floating VEB,
489 while other VFs connect to the normal VEB.
490
491 The current implementation only supports one floating VEB and one regular
492 VEB. VFs can connect to a floating VEB or a regular VEB according to the
493 configuration passed on the EAL command line.
494
495 The floating VEB functionality requires a NIC firmware version of 5.0
496 or greater.
497
498 Dynamic Device Personalization (DDP)
499 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
500
501 The Intel® Ethernet 700 Series except for the Intel Ethernet Connection
502 X722 support a feature called "Dynamic Device Personalization (DDP)",
503 which is used to configure hardware by downloading a profile to support
504 protocols/filters which are not supported by default. The DDP
505 functionality requires a NIC firmware version of 6.0 or greater.
506
507 Current implementation supports GTP-C/GTP-U/PPPoE/PPPoL2TP/ESP,
508 steering can be used with rte_flow API.
509
510 GTPv1 package is released, and it can be downloaded from
511 https://downloadcenter.intel.com/download/27587.
512
513 PPPoE package is released, and it can be downloaded from
514 https://downloadcenter.intel.com/download/28040.
515
516 ESP-AH package is released, and it can be downloaded from
517 https://downloadcenter.intel.com/download/29446.
518
519 Load a profile which supports GTP and store backup profile:
520
521 .. code-block:: console
522
523    testpmd> ddp add 0 ./gtp.pkgo,./backup.pkgo
524
525 Delete a GTP profile and restore backup profile:
526
527 .. code-block:: console
528
529    testpmd> ddp del 0 ./backup.pkgo
530
531 Get loaded DDP package info list:
532
533 .. code-block:: console
534
535    testpmd> ddp get list 0
536
537 Display information about a GTP profile:
538
539 .. code-block:: console
540
541    testpmd> ddp get info ./gtp.pkgo
542
543 Input set configuration
544 ~~~~~~~~~~~~~~~~~~~~~~~
545 Input set for any PCTYPE can be configured with user defined configuration,
546 For example, to use only 48bit prefix for IPv6 src address for IPv6 TCP RSS:
547
548 .. code-block:: console
549
550    testpmd> port config 0 pctype 43 hash_inset clear all
551    testpmd> port config 0 pctype 43 hash_inset set field 13
552    testpmd> port config 0 pctype 43 hash_inset set field 14
553    testpmd> port config 0 pctype 43 hash_inset set field 15
554
555 Queue region configuration
556 ~~~~~~~~~~~~~~~~~~~~~~~~~~~
557 The Intel® Ethernet 700 Series supports a feature of queue regions
558 configuration for RSS in the PF, so that different traffic classes or
559 different packet classification types can be separated to different
560 queues in different queue regions. There is an API for configuration
561 of queue regions in RSS with a command line. It can parse the parameters
562 of the region index, queue number, queue start index, user priority, traffic
563 classes and so on. Depending on commands from the command line, it will call
564 i40e private APIs and start the process of setting or flushing the queue
565 region configuration. As this feature is specific for i40e only private
566 APIs are used. These new ``test_pmd`` commands are as shown below. For
567 details please refer to :doc:`../testpmd_app_ug/index`.
568
569 .. code-block:: console
570
571    testpmd> set port (port_id) queue-region region_id (value) \
572                 queue_start_index (value) queue_num (value)
573    testpmd> set port (port_id) queue-region region_id (value) flowtype (value)
574    testpmd> set port (port_id) queue-region UP (value) region_id (value)
575    testpmd> set port (port_id) queue-region flush (on|off)
576    testpmd> show port (port_id) queue-region
577
578 Generic flow API
579 ~~~~~~~~~~~~~~~~~~~
580
581 - ``RSS Flow``
582
583   RSS Flow supports to set hash input set, hash function, enable hash
584   and configure queue region.
585   For example:
586   Configure queue region as queue 0, 1, 2, 3.
587
588   .. code-block:: console
589
590     testpmd> flow create 0 ingress pattern end actions rss types end \
591       queues 0 1 2 3 end / end
592
593   Enable hash and set input set for ipv4-tcp.
594
595   .. code-block:: console
596
597     testpmd> flow create 0 ingress pattern eth / ipv4 / tcp / end \
598       actions rss types ipv4-tcp l3-src-only end queues end / end
599
600   Set symmetric hash enable for flow type ipv4-tcp.
601
602   .. code-block:: console
603
604     testpmd> flow create 0 ingress pattern eth / ipv4 / tcp / end \
605       actions rss types ipv4-tcp end queues end func symmetric_toeplitz / end
606
607   Set hash function as simple xor.
608
609   .. code-block:: console
610
611     testpmd> flow create 0 ingress pattern end actions rss types end \
612       queues end func simple_xor / end
613
614 Limitations or Known issues
615 ---------------------------
616
617 MPLS packet classification
618 ~~~~~~~~~~~~~~~~~~~~~~~~~~
619
620 For firmware versions prior to 5.0, MPLS packets are not recognized by the NIC.
621 The L2 Payload flow type in flow director can be used to classify MPLS packet
622 by using a command in testpmd like:
623
624    testpmd> flow_director_filter 0 mode IP add flow l2_payload ether \
625             0x8847 flexbytes () fwd pf queue <N> fd_id <M>
626
627 With the NIC firmware version 5.0 or greater, some limited MPLS support
628 is added: Native MPLS (MPLS in Ethernet) skip is implemented, while no
629 new packet type, no classification or offload are possible. With this change,
630 L2 Payload flow type in flow director cannot be used to classify MPLS packet
631 as with previous firmware versions. Meanwhile, the Ethertype filter can be
632 used to classify MPLS packet by using a command in testpmd like:
633
634    testpmd> ethertype_filter 0 add mac_ignr 00:00:00:00:00:00 ethertype \
635             0x8847 fwd queue <M>
636
637 16 Byte RX Descriptor setting on DPDK VF
638 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
639
640 Currently the VF's RX descriptor mode is decided by PF. There's no PF-VF
641 interface for VF to request the RX descriptor mode, also no interface to notify
642 VF its own RX descriptor mode.
643 For all available versions of the i40e driver, these drivers don't support 16
644 byte RX descriptor. If the Linux i40e kernel driver is used as host driver,
645 while DPDK i40e PMD is used as the VF driver, DPDK cannot choose 16 byte receive
646 descriptor. The reason is that the RX descriptor is already set to 32 byte by
647 the i40e kernel driver. That is to say, user should keep
648 ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC=n`` in config file.
649 In the future, if the Linux i40e driver supports 16 byte RX descriptor, user
650 should make sure the DPDK VF uses the same RX descriptor mode, 16 byte or 32
651 byte, as the PF driver.
652
653 The same rule for DPDK PF + DPDK VF. The PF and VF should use the same RX
654 descriptor mode. Or the VF RX will not work.
655
656 Receive packets with Ethertype 0x88A8
657 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
658
659 Due to the FW limitation, PF can receive packets with Ethertype 0x88A8
660 only when floating VEB is disabled.
661
662 Incorrect Rx statistics when packet is oversize
663 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
664
665 When a packet is over maximum frame size, the packet is dropped.
666 However, the Rx statistics, when calling `rte_eth_stats_get` incorrectly
667 shows it as received.
668
669 VF & TC max bandwidth setting
670 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
671
672 The per VF max bandwidth and per TC max bandwidth cannot be enabled in parallel.
673 The behavior is different when handling per VF and per TC max bandwidth setting.
674 When enabling per VF max bandwidth, SW will check if per TC max bandwidth is
675 enabled. If so, return failure.
676 When enabling per TC max bandwidth, SW will check if per VF max bandwidth
677 is enabled. If so, disable per VF max bandwidth and continue with per TC max
678 bandwidth setting.
679
680 TC TX scheduling mode setting
681 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
682
683 There are 2 TX scheduling modes for TCs, round robin and strict priority mode.
684 If a TC is set to strict priority mode, it can consume unlimited bandwidth.
685 It means if APP has set the max bandwidth for that TC, it comes to no
686 effect.
687 It's suggested to set the strict priority mode for a TC that is latency
688 sensitive but no consuming much bandwidth.
689
690 VF performance is impacted by PCI extended tag setting
691 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
692
693 To reach maximum NIC performance in the VF the PCI extended tag must be
694 enabled. The DPDK i40e PF driver will set this feature during initialization,
695 but the kernel PF driver does not. So when running traffic on a VF which is
696 managed by the kernel PF driver, a significant NIC performance downgrade has
697 been observed (for 64 byte packets, there is about 25% line-rate downgrade for
698 a 25GbE device and about 35% for a 40GbE device).
699
700 For kernel version >= 4.11, the kernel's PCI driver will enable the extended
701 tag if it detects that the device supports it. So by default, this is not an
702 issue. For kernels <= 4.11 or when the PCI extended tag is disabled it can be
703 enabled using the steps below.
704
705 #. Get the current value of the PCI configure register::
706
707       setpci -s <XX:XX.X> a8.w
708
709 #. Set bit 8::
710
711       value = value | 0x100
712
713 #. Set the PCI configure register with new value::
714
715       setpci -s <XX:XX.X> a8.w=<value>
716
717 Vlan strip of VF
718 ~~~~~~~~~~~~~~~~
719
720 The VF vlan strip function is only supported in the i40e kernel driver >= 2.1.26.
721
722 DCB function
723 ~~~~~~~~~~~~
724
725 DCB works only when RSS is enabled.
726
727 Global configuration warning
728 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
729
730 I40E PMD will set some global registers to enable some function or set some
731 configure. Then when using different ports of the same NIC with Linux kernel
732 and DPDK, the port with Linux kernel will be impacted by the port with DPDK.
733 For example, register I40E_GL_SWT_L2TAGCTRL is used to control L2 tag, i40e
734 PMD uses I40E_GL_SWT_L2TAGCTRL to set vlan TPID. If setting TPID in port A
735 with DPDK, then the configuration will also impact port B in the NIC with
736 kernel driver, which don't want to use the TPID.
737 So PMD reports warning to clarify what is changed by writing global register.
738
739 High Performance of Small Packets on 40GbE NIC
740 ----------------------------------------------
741
742 As there might be firmware fixes for performance enhancement in latest version
743 of firmware image, the firmware update might be needed for getting high performance.
744 Check the Intel support website for the latest firmware updates.
745 Users should consult the release notes specific to a DPDK release to identify
746 the validated firmware version for a NIC using the i40e driver.
747
748 Use 16 Bytes RX Descriptor Size
749 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
750
751 As i40e PMD supports both 16 and 32 bytes RX descriptor sizes, and 16 bytes size can provide helps to high performance of small packets.
752 Configuration of ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` in config files can be changed to use 16 bytes size RX descriptors.
753
754 Input set requirement of each pctype for FDIR
755 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
756
757 Each PCTYPE can only have one specific FDIR input set at one time.
758 For example, if creating 2 rte_flow rules with different input set for one PCTYPE,
759 it will fail and return the info "Conflict with the first rule's input set",
760 which means the current rule's input set conflicts with the first rule's.
761 Remove the first rule if want to change the input set of the PCTYPE.
762
763 Example of getting best performance with l3fwd example
764 ------------------------------------------------------
765
766 The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with a
767 server with Intel Xeon processors and Intel Ethernet CNA XL710.
768
769 The example scenario is to get best performance with two Intel Ethernet CNA XL710 40GbE ports.
770 See :numref:`figure_intel_perf_test_setup` for the performance test setup.
771
772 .. _figure_intel_perf_test_setup:
773
774 .. figure:: img/intel_perf_test_setup.*
775
776    Performance Test Setup
777
778
779 1. Add two Intel Ethernet CNA XL710 to the platform, and use one port per card to get best performance.
780    The reason for using two NICs is to overcome a PCIe v3.0 limitation since it cannot provide 80GbE bandwidth
781    for two 40GbE ports, but two different PCIe v3.0 x8 slot can.
782    Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
783
784       82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
785       85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
786
787 2. Connect the ports to the traffic generator. For high speed testing, it's best to use a hardware traffic generator.
788
789 3. Check the PCI devices numa node (socket id) and get the cores number on the exact socket id.
790    In this case, ``82:00.0`` and ``85:00.0`` are both in socket 1, and the cores on socket 1 in the referenced platform
791    are 18-35 and 54-71.
792    Note: Don't use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical
793    cores from different cores (e.g core18 and core19).
794
795 4. Bind these two ports to igb_uio.
796
797 5. As to Intel Ethernet CNA XL710 40GbE port, we need at least two queue pairs to achieve best performance, then two queues per port
798    will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
799
800 6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
801    Compile the ``l3fwd sample`` with the default lpm mode.
802
803 7. The command line of running l3fwd would be something like the following::
804
805       ./l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \
806               -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
807
808    This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
809    core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
810
811 8. Configure the traffic at a traffic generator.
812
813    * Start creating a stream on packet generator.
814
815    * Set the Ethernet II type to 0x0800.
816
817 Tx bytes affected by the link status change
818 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
819
820 For firmware versions prior to 6.01 for X710 series and 3.33 for X722 series, the tx_bytes statistics data is affected by
821 the link down event. Each time the link status changes to down, the tx_bytes decreases 110 bytes.