doc: update i40e guide for GTPv1 package release
[dpdk.git] / doc / guides / nics / i40e.rst
1 ..  SPDX-License-Identifier: BSD-3-Clause
2     Copyright(c) 2016 Intel Corporation.
3
4 I40E Poll Mode Driver
5 ======================
6
7 The i40e PMD (librte_pmd_i40e) provides poll mode driver support for
8 10/25/40 Gbps Intel® Ethernet 700 Series Network Adapters based on
9 the Intel Ethernet Controller X710/XL710/XXV710 and Intel Ethernet
10 Connection X722 (only support part of features).
11
12
13 Features
14 --------
15
16 Features of the i40e PMD are:
17
18 - Multiple queues for TX and RX
19 - Receiver Side Scaling (RSS)
20 - MAC/VLAN filtering
21 - Packet type information
22 - Flow director
23 - Cloud filter
24 - Checksum offload
25 - VLAN/QinQ stripping and inserting
26 - TSO offload
27 - Promiscuous mode
28 - Multicast mode
29 - Port hardware statistics
30 - Jumbo frames
31 - Link state information
32 - Link flow control
33 - Mirror on port, VLAN and VSI
34 - Interrupt mode for RX
35 - Scattered and gather for TX and RX
36 - Vector Poll mode driver
37 - DCB
38 - VMDQ
39 - SR-IOV VF
40 - Hot plug
41 - IEEE1588/802.1AS timestamping
42 - VF Daemon (VFD) - EXPERIMENTAL
43 - Dynamic Device Personalization (DDP)
44 - Queue region configuration
45 - Virtual Function Port Representors
46
47 Prerequisites
48 -------------
49
50 - Identifying your adapter using `Intel Support
51   <http://www.intel.com/support>`_ and get the latest NVM/FW images.
52
53 - Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
54
55 - To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms"
56   section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
57
58 - Upgrade the NVM/FW version following the `Intel® Ethernet NVM Update Tool Quick Usage Guide for Linux
59   <https://www-ssl.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-linux-usage-guide.html>`_ and `Intel® Ethernet NVM Update Tool: Quick Usage Guide for EFI <https://www.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-efi-usage-guide.html>`_ if needed.
60
61 Recommended Matching List
62 -------------------------
63
64 It is highly recommended to upgrade the i40e kernel driver and firmware to
65 avoid the compatibility issues with i40e PMD. Here is the suggested matching
66 list which has been tested and verified. The detailed information can refer
67 to chapter Tested Platforms/Tested NICs in release notes.
68
69    +--------------+-----------------------+------------------+
70    | DPDK version | Kernel driver version | Firmware version |
71    +==============+=======================+==================+
72    |    18.05     |         2.4.6         |       6.01       |
73    +--------------+-----------------------+------------------+
74    |    18.02     |         2.4.3         |       6.01       |
75    +--------------+-----------------------+------------------+
76    |    17.11     |         2.1.26        |       6.01       |
77    +--------------+-----------------------+------------------+
78    |    17.08     |         2.0.19        |       6.01       |
79    +--------------+-----------------------+------------------+
80    |    17.05     |         1.5.23        |       5.05       |
81    +--------------+-----------------------+------------------+
82    |    17.02     |         1.5.23        |       5.05       |
83    +--------------+-----------------------+------------------+
84    |    16.11     |         1.5.23        |       5.05       |
85    +--------------+-----------------------+------------------+
86    |    16.07     |         1.4.25        |       5.04       |
87    +--------------+-----------------------+------------------+
88    |    16.04     |         1.4.25        |       5.02       |
89    +--------------+-----------------------+------------------+
90
91 Pre-Installation Configuration
92 ------------------------------
93
94 Config File Options
95 ~~~~~~~~~~~~~~~~~~~
96
97 The following options can be modified in the ``config`` file.
98 Please note that enabling debugging options may affect system performance.
99
100 - ``CONFIG_RTE_LIBRTE_I40E_PMD`` (default ``y``)
101
102   Toggle compilation of the ``librte_pmd_i40e`` driver.
103
104 - ``CONFIG_RTE_LIBRTE_I40E_DEBUG_*`` (default ``n``)
105
106   Toggle display of generic debugging messages.
107
108 - ``CONFIG_RTE_LIBRTE_I40E_RX_ALLOW_BULK_ALLOC`` (default ``y``)
109
110   Toggle bulk allocation for RX.
111
112 - ``CONFIG_RTE_LIBRTE_I40E_INC_VECTOR`` (default ``n``)
113
114   Toggle the use of Vector PMD instead of normal RX/TX path.
115   To enable vPMD for RX, bulk allocation for Rx must be allowed.
116
117 - ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` (default ``n``)
118
119   Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte.
120
121 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
122
123   Number of queues reserved for PF.
124
125 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
126
127   Number of queues reserved for each VMDQ Pool.
128
129 Runtime Config Options
130 ~~~~~~~~~~~~~~~~~~~~~~
131
132 - ``Number of Queues per VF`` (default ``4``)
133
134   The number of queue per VF is determined by its host PF. If the PCI address
135   of an i40e PF is aaaa:bb.cc, the number of queues per VF can be configured
136   with EAL parameter like -w aaaa:bb.cc,queue-num-per-vf=n. The value n can be
137   1, 2, 4, 8 or 16. If no such parameter is configured, the number of queues
138   per VF is 4 by default.
139
140 - ``Support multiple driver`` (default ``disable``)
141
142   There was a multiple driver support issue during use of 700 series Ethernet
143   Adapter with both Linux kernel and DPDK PMD. To fix this issue, ``devargs``
144   parameter ``support-multi-driver`` is introduced, for example::
145
146     -w 84:00.0,support-multi-driver=1
147
148   With the above configuration, DPDK PMD will not change global registers, and
149   will switch PF interrupt from IntN to Int0 to avoid interrupt conflict between
150   DPDK and Linux Kernel.
151
152 - ``Support VF Port Representor`` (default ``not enabled``)
153
154   The i40e PF PMD supports the creation of VF port representors for the control
155   and monitoring of i40e virtual function devices. Each port representor
156   corresponds to a single virtual function of that device. Using the ``devargs``
157   option ``representor`` the user can specify which virtual functions to create
158   port representors for on initialization of the PF PMD by passing the VF IDs of
159   the VFs which are required.::
160
161   -w DBDF,representor=[0,1,4]
162
163   Currently hot-plugging of representor ports is not supported so all required
164   representors must be specified on the creation of the PF.
165
166 Driver compilation and testing
167 ------------------------------
168
169 Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
170 for details.
171
172
173 SR-IOV: Prerequisites and sample Application Notes
174 --------------------------------------------------
175
176 #. Load the kernel module:
177
178    .. code-block:: console
179
180       modprobe i40e
181
182    Check the output in dmesg:
183
184    .. code-block:: console
185
186       i40e 0000:83:00.1 ens802f0: renamed from eth0
187
188 #. Bring up the PF ports:
189
190    .. code-block:: console
191
192       ifconfig ens802f0 up
193
194 #. Create VF device(s):
195
196    Echo the number of VFs to be created into the ``sriov_numvfs`` sysfs entry
197    of the parent PF.
198
199    Example:
200
201    .. code-block:: console
202
203       echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
204
205
206 #. Assign VF MAC address:
207
208    Assign MAC address to the VF using iproute2 utility. The syntax is:
209
210    .. code-block:: console
211
212       ip link set <PF netdev id> vf <VF id> mac <macaddr>
213
214    Example:
215
216    .. code-block:: console
217
218       ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0
219
220 #. Assign VF to VM, and bring up the VM.
221    Please see the documentation for the *I40E/IXGBE/IGB Virtual Function Driver*.
222
223 #. Running testpmd:
224
225    Follow instructions available in the document
226    :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
227    to run testpmd.
228
229    Example output:
230
231    .. code-block:: console
232
233       ...
234       EAL: PCI device 0000:83:00.0 on NUMA socket 1
235       EAL: probe driver: 8086:1572 rte_i40e_pmd
236       EAL: PCI memory mapped at 0x7f7f80000000
237       EAL: PCI memory mapped at 0x7f7f80800000
238       PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a
239       Interactive-mode selected
240       Configuring Port 0 (socket 0)
241       ...
242
243       PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are
244       satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0.
245
246       ...
247       Port 0: 68:05:CA:26:85:84
248       Checking link statuses...
249       Port 0 Link Up - speed 10000 Mbps - full-duplex
250       Done
251
252       testpmd>
253
254
255 Sample Application Notes
256 ------------------------
257
258 Vlan filter
259 ~~~~~~~~~~~
260
261 Vlan filter only works when Promiscuous mode is off.
262
263 To start ``testpmd``, and add vlan 10 to port 0:
264
265 .. code-block:: console
266
267     ./app/testpmd -l 0-15 -n 4 -- -i --forward-mode=mac
268     ...
269
270     testpmd> set promisc 0 off
271     testpmd> rx_vlan add 10 0
272
273
274 Flow Director
275 ~~~~~~~~~~~~~
276
277 The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
278 The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload.
279
280 The default input set of each flow type is::
281
282    ipv4-other : src_ip_address, dst_ip_address
283    ipv4-frag  : src_ip_address, dst_ip_address
284    ipv4-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
285    ipv4-udp   : src_ip_address, dst_ip_address, src_port, dst_port
286    ipv4-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
287                 verification_tag
288    ipv6-other : src_ip_address, dst_ip_address
289    ipv6-frag  : src_ip_address, dst_ip_address
290    ipv6-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
291    ipv6-udp   : src_ip_address, dst_ip_address, src_port, dst_port
292    ipv6-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
293                 verification_tag
294    l2_payload : ether_type
295
296 The flex payload is selected from offset 0 to 15 of packet's payload by default, while it is masked out from matching.
297
298 Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``:
299
300 .. code-block:: console
301
302    ./app/testpmd -l 0-15 -n 4 -- -i --disable-rss --pkt-filter-mode=perfect \
303                  --rxq=8 --txq=8 --nb-cores=8 --nb-ports=1
304
305 Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1:
306
307 .. code-block:: console
308
309    testpmd> flow_director_filter 0 mode IP add flow ipv4-udp  \
310             src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \
311             fwd pf queue 1 fd_id 1
312
313 Check the flow director status:
314
315 .. code-block:: console
316
317    testpmd> show port fdir 0
318
319    ######################## FDIR infos for port 0      ####################
320      MODE:   PERFECT
321      SUPPORTED FLOW TYPE:  ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other
322                            ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other
323                            l2_payload
324      FLEX PAYLOAD INFO:
325      max_len:       16          payload_limit: 480
326      payload_unit:  2           payload_seg:   3
327      bitmask_unit:  2           bitmask_num:   2
328      MASK:
329        vlan_tci: 0x0000,
330        src_ipv4: 0x00000000,
331        dst_ipv4: 0x00000000,
332        src_port: 0x0000,
333        dst_port: 0x0000
334        src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000,
335        dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000
336      FLEX PAYLOAD SRC OFFSET:
337        L2_PAYLOAD:    0      1      2      3      4      5      6  ...
338        L3_PAYLOAD:    0      1      2      3      4      5      6  ...
339        L4_PAYLOAD:    0      1      2      3      4      5      6  ...
340      FLEX MASK CFG:
341        ipv4-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
342        ipv4-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
343        ipv4-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
344        ipv4-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
345        ipv4-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
346        ipv6-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
347        ipv6-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
348        ipv6-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
349        ipv6-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
350        ipv6-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
351        l2_payload:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
352      guarant_count: 1           best_count:    0
353      guarant_space: 512         best_space:    7168
354      collision:     0           free:          0
355      maxhash:       0           maxlen:        0
356      add:           0           remove:        0
357      f_add:         0           f_remove:      0
358
359
360 Delete all flow director rules on a port:
361
362 .. code-block:: console
363
364    testpmd> flush_flow_director 0
365
366 Floating VEB
367 ~~~~~~~~~~~~~
368
369 The Intel® Ethernet 700 Series support a feature called
370 "Floating VEB".
371
372 A Virtual Ethernet Bridge (VEB) is an IEEE Edge Virtual Bridging (EVB) term
373 for functionality that allows local switching between virtual endpoints within
374 a physical endpoint and also with an external bridge/network.
375
376 A "Floating" VEB doesn't have an uplink connection to the outside world so all
377 switching is done internally and remains within the host. As such, this
378 feature provides security benefits.
379
380 In addition, a Floating VEB overcomes a limitation of normal VEBs where they
381 cannot forward packets when the physical link is down. Floating VEBs don't need
382 to connect to the NIC port so they can still forward traffic from VF to VF
383 even when the physical link is down.
384
385 Therefore, with this feature enabled VFs can be limited to communicating with
386 each other but not an outside network, and they can do so even when there is
387 no physical uplink on the associated NIC port.
388
389 To enable this feature, the user should pass a ``devargs`` parameter to the
390 EAL, for example::
391
392     -w 84:00.0,enable_floating_veb=1
393
394 In this configuration the PMD will use the floating VEB feature for all the
395 VFs created by this PF device.
396
397 Alternatively, the user can specify which VFs need to connect to this floating
398 VEB using the ``floating_veb_list`` argument::
399
400     -w 84:00.0,enable_floating_veb=1,floating_veb_list=1;3-4
401
402 In this example ``VF1``, ``VF3`` and ``VF4`` connect to the floating VEB,
403 while other VFs connect to the normal VEB.
404
405 The current implementation only supports one floating VEB and one regular
406 VEB. VFs can connect to a floating VEB or a regular VEB according to the
407 configuration passed on the EAL command line.
408
409 The floating VEB functionality requires a NIC firmware version of 5.0
410 or greater.
411
412 Dynamic Device Personalization (DDP)
413 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
414
415 The Intel® Ethernet 700 Series except for the Intel Ethernet Connection
416 X722 support a feature called "Dynamic Device Personalization (DDP)",
417 which is used to configure hardware by downloading a profile to support
418 protocols/filters which are not supported by default. The DDP
419 functionality requires a NIC firmware version of 6.0 or greater.
420
421 Current implementation supports GTP-C/GTP-U/PPPoE/PPPoL2TP,
422 steering can be used with rte_flow API.
423
424 GTPv1 package is released, and it can be downloaded from
425 https://downloadcenter.intel.com/download/27587.
426
427 Load a profile which supports GTP and store backup profile:
428
429 .. code-block:: console
430
431    testpmd> ddp add 0 ./gtp.pkgo,./backup.pkgo
432
433 Delete a GTP profile and restore backup profile:
434
435 .. code-block:: console
436
437    testpmd> ddp del 0 ./backup.pkgo
438
439 Get loaded DDP package info list:
440
441 .. code-block:: console
442
443    testpmd> ddp get list 0
444
445 Display information about a GTP profile:
446
447 .. code-block:: console
448
449    testpmd> ddp get info ./gtp.pkgo
450
451 Input set configuration
452 ~~~~~~~~~~~~~~~~~~~~~~~
453 Input set for any PCTYPE can be configured with user defined configuration,
454 For example, to use only 48bit prefix for IPv6 src address for IPv6 TCP RSS:
455
456 .. code-block:: console
457
458    testpmd> port config 0 pctype 43 hash_inset clear all
459    testpmd> port config 0 pctype 43 hash_inset set field 13
460    testpmd> port config 0 pctype 43 hash_inset set field 14
461    testpmd> port config 0 pctype 43 hash_inset set field 15
462
463 Queue region configuration
464 ~~~~~~~~~~~~~~~~~~~~~~~~~~~
465 The Intel® Ethernet 700 Series supports a feature of queue regions
466 configuration for RSS in the PF, so that different traffic classes or
467 different packet classification types can be separated to different
468 queues in different queue regions. There is an API for configuration
469 of queue regions in RSS with a command line. It can parse the parameters
470 of the region index, queue number, queue start index, user priority, traffic
471 classes and so on. Depending on commands from the command line, it will call
472 i40e private APIs and start the process of setting or flushing the queue
473 region configuration. As this feature is specific for i40e only private
474 APIs are used. These new ``test_pmd`` commands are as shown below. For
475 details please refer to :doc:`../testpmd_app_ug/index`.
476
477 .. code-block:: console
478
479    testpmd> set port (port_id) queue-region region_id (value) \
480                 queue_start_index (value) queue_num (value)
481    testpmd> set port (port_id) queue-region region_id (value) flowtype (value)
482    testpmd> set port (port_id) queue-region UP (value) region_id (value)
483    testpmd> set port (port_id) queue-region flush (on|off)
484    testpmd> show port (port_id) queue-region
485
486 Limitations or Known issues
487 ---------------------------
488
489 MPLS packet classification
490 ~~~~~~~~~~~~~~~~~~~~~~~~~~
491
492 For firmware versions prior to 5.0, MPLS packets are not recognized by the NIC.
493 The L2 Payload flow type in flow director can be used to classify MPLS packet
494 by using a command in testpmd like:
495
496    testpmd> flow_director_filter 0 mode IP add flow l2_payload ether \
497             0x8847 flexbytes () fwd pf queue <N> fd_id <M>
498
499 With the NIC firmware version 5.0 or greater, some limited MPLS support
500 is added: Native MPLS (MPLS in Ethernet) skip is implemented, while no
501 new packet type, no classification or offload are possible. With this change,
502 L2 Payload flow type in flow director cannot be used to classify MPLS packet
503 as with previous firmware versions. Meanwhile, the Ethertype filter can be
504 used to classify MPLS packet by using a command in testpmd like:
505
506    testpmd> ethertype_filter 0 add mac_ignr 00:00:00:00:00:00 ethertype \
507             0x8847 fwd queue <M>
508
509 16 Byte RX Descriptor setting on DPDK VF
510 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
511
512 Currently the VF's RX descriptor mode is decided by PF. There's no PF-VF
513 interface for VF to request the RX descriptor mode, also no interface to notify
514 VF its own RX descriptor mode.
515 For all available versions of the i40e driver, these drivers don't support 16
516 byte RX descriptor. If the Linux i40e kernel driver is used as host driver,
517 while DPDK i40e PMD is used as the VF driver, DPDK cannot choose 16 byte receive
518 descriptor. The reason is that the RX descriptor is already set to 32 byte by
519 the i40e kernel driver. That is to say, user should keep
520 ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC=n`` in config file.
521 In the future, if the Linux i40e driver supports 16 byte RX descriptor, user
522 should make sure the DPDK VF uses the same RX descriptor mode, 16 byte or 32
523 byte, as the PF driver.
524
525 The same rule for DPDK PF + DPDK VF. The PF and VF should use the same RX
526 descriptor mode. Or the VF RX will not work.
527
528 Receive packets with Ethertype 0x88A8
529 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
530
531 Due to the FW limitation, PF can receive packets with Ethertype 0x88A8
532 only when floating VEB is disabled.
533
534 Incorrect Rx statistics when packet is oversize
535 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
536
537 When a packet is over maximum frame size, the packet is dropped.
538 However, the Rx statistics, when calling `rte_eth_stats_get` incorrectly
539 shows it as received.
540
541 VF & TC max bandwidth setting
542 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
543
544 The per VF max bandwidth and per TC max bandwidth cannot be enabled in parallel.
545 The behavior is different when handling per VF and per TC max bandwidth setting.
546 When enabling per VF max bandwidth, SW will check if per TC max bandwidth is
547 enabled. If so, return failure.
548 When enabling per TC max bandwidth, SW will check if per VF max bandwidth
549 is enabled. If so, disable per VF max bandwidth and continue with per TC max
550 bandwidth setting.
551
552 TC TX scheduling mode setting
553 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
554
555 There're 2 TX scheduling modes for TCs, round robin and strict priority mode.
556 If a TC is set to strict priority mode, it can consume unlimited bandwidth.
557 It means if APP has set the max bandwidth for that TC, it comes to no
558 effect.
559 It's suggested to set the strict priority mode for a TC that is latency
560 sensitive but no consuming much bandwidth.
561
562 VF performance is impacted by PCI extended tag setting
563 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
564
565 To reach maximum NIC performance in the VF the PCI extended tag must be
566 enabled. The DPDK i40e PF driver will set this feature during initialization,
567 but the kernel PF driver does not. So when running traffic on a VF which is
568 managed by the kernel PF driver, a significant NIC performance downgrade has
569 been observed (for 64 byte packets, there is about 25% line-rate downgrade for
570 a 25GbE device and about 35% for a 40GbE device).
571
572 For kernel version >= 4.11, the kernel's PCI driver will enable the extended
573 tag if it detects that the device supports it. So by default, this is not an
574 issue. For kernels <= 4.11 or when the PCI extended tag is disabled it can be
575 enabled using the steps below.
576
577 #. Get the current value of the PCI configure register::
578
579       setpci -s <XX:XX.X> a8.w
580
581 #. Set bit 8::
582
583       value = value | 0x100
584
585 #. Set the PCI configure register with new value::
586
587       setpci -s <XX:XX.X> a8.w=<value>
588
589 Vlan strip of VF
590 ~~~~~~~~~~~~~~~~
591
592 The VF vlan strip function is only supported in the i40e kernel driver >= 2.1.26.
593
594 DCB function
595 ~~~~~~~~~~~~
596
597 DCB works only when RSS is enabled.
598
599 Global configuration warning
600 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
601
602 I40E PMD will set some global registers to enable some function or set some
603 configure. Then when using different ports of the same NIC with Linux kernel
604 and DPDK, the port with Linux kernel will be impacted by the port with DPDK.
605 For example, register I40E_GL_SWT_L2TAGCTRL is used to control L2 tag, i40e
606 PMD uses I40E_GL_SWT_L2TAGCTRL to set vlan TPID. If setting TPID in port A
607 with DPDK, then the configuration will also impact port B in the NIC with
608 kernel driver, which don't want to use the TPID.
609 So PMD reports warning to clarify what is changed by writing global register.
610
611 High Performance of Small Packets on 40GbE NIC
612 ----------------------------------------------
613
614 As there might be firmware fixes for performance enhancement in latest version
615 of firmware image, the firmware update might be needed for getting high performance.
616 Check the Intel support website for the latest firmware updates.
617 Users should consult the release notes specific to a DPDK release to identify
618 the validated firmware version for a NIC using the i40e driver.
619
620 Use 16 Bytes RX Descriptor Size
621 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
622
623 As i40e PMD supports both 16 and 32 bytes RX descriptor sizes, and 16 bytes size can provide helps to high performance of small packets.
624 Configuration of ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` in config files can be changed to use 16 bytes size RX descriptors.
625
626 Example of getting best performance with l3fwd example
627 ------------------------------------------------------
628
629 The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with a
630 server with Intel Xeon processors and Intel Ethernet CNA XL710.
631
632 The example scenario is to get best performance with two Intel Ethernet CNA XL710 40GbE ports.
633 See :numref:`figure_intel_perf_test_setup` for the performance test setup.
634
635 .. _figure_intel_perf_test_setup:
636
637 .. figure:: img/intel_perf_test_setup.*
638
639    Performance Test Setup
640
641
642 1. Add two Intel Ethernet CNA XL710 to the platform, and use one port per card to get best performance.
643    The reason for using two NICs is to overcome a PCIe v3.0 limitation since it cannot provide 80GbE bandwidth
644    for two 40GbE ports, but two different PCIe v3.0 x8 slot can.
645    Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
646
647       82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
648       85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
649
650 2. Connect the ports to the traffic generator. For high speed testing, it's best to use a hardware traffic generator.
651
652 3. Check the PCI devices numa node (socket id) and get the cores number on the exact socket id.
653    In this case, ``82:00.0`` and ``85:00.0`` are both in socket 1, and the cores on socket 1 in the referenced platform
654    are 18-35 and 54-71.
655    Note: Don't use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical
656    cores from different cores (e.g core18 and core19).
657
658 4. Bind these two ports to igb_uio.
659
660 5. As to Intel Ethernet CNA XL710 40GbE port, we need at least two queue pairs to achieve best performance, then two queues per port
661    will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
662
663 6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
664    Compile the ``l3fwd sample`` with the default lpm mode.
665
666 7. The command line of running l3fwd would be something like the following::
667
668       ./l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \
669               -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
670
671    This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
672    core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
673
674 8. Configure the traffic at a traffic generator.
675
676    * Start creating a stream on packet generator.