net/sfc: support VLAN offload on transmit path
[dpdk.git] / doc / guides / nics / sfc_efx.rst
1 ..  BSD LICENSE
2     Copyright (c) 2016 Solarflare Communications Inc.
3     All rights reserved.
4
5     This software was jointly developed between OKTET Labs (under contract
6     for Solarflare) and Solarflare Communications, Inc.
7
8     Redistribution and use in source and binary forms, with or without
9     modification, are permitted provided that the following conditions are met:
10
11     1. Redistributions of source code must retain the above copyright notice,
12        this list of conditions and the following disclaimer.
13     2. Redistributions in binary form must reproduce the above copyright notice,
14        this list of conditions and the following disclaimer in the documentation
15        and/or other materials provided with the distribution.
16
17     THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
18     AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
19     THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
20     PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
21     CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
22     EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO,
23     PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS;
24     OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY,
25     WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
26     OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE,
27     EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
28
29 Solarflare libefx-based Poll Mode Driver
30 ========================================
31
32 The SFC EFX PMD (**librte_pmd_sfc_efx**) provides poll mode driver support
33 for **Solarflare SFN7xxx and SFN8xxx** family of 10/40 Gbps adapters.
34 SFC EFX PMD has support for the latest Linux and FreeBSD operating systems.
35
36 More information can be found at `Solarflare Communications website
37 <http://solarflare.com>`_.
38
39
40 Features
41 --------
42
43 SFC EFX PMD has support for:
44
45 - Multiple transmit and receive queues
46
47 - Link state information including link status change interrupt
48
49 - IPv4/IPv6 TCP/UDP transmit checksum offload
50
51 - Port hardware statistics
52
53 - Extended statistics (see Solarflare Server Adapter User's Guide for
54   the statistics description)
55
56 - Basic flow control
57
58 - MTU update
59
60 - Jumbo frames up to 9K
61
62 - Promiscuous mode
63
64 - Allmulticast mode
65
66 - Multicast MAC filter
67
68 - IPv4/IPv6 TCP/UDP receive checksum offload
69
70 - Received packet type information
71
72 - Scattered Rx DMA for packet that are larger that a single Rx descriptor
73
74 - Deferred receive and transmit queue start
75
76 - Transmit VLAN insertion (if running firmware variant supports it)
77
78
79 Non-supported Features
80 ----------------------
81
82 The features not yet supported include:
83
84 - Receive queue interupts
85
86 - Priority-based flow control
87
88 - Loopback
89
90 - Configurable RX CRC stripping (always stripped)
91
92 - Header split on receive
93
94 - VLAN filtering
95
96 - VLAN stripping
97
98 - LRO
99
100
101 Limitations
102 -----------
103
104 Due to requirements on receive buffer alignment and usage of the receive
105 buffer for the auxiliary packet information provided by the NIC up to
106 extra 269 (14 bytes prefix plus up to 255 bytes for end padding) bytes may be
107 required in the receive buffer.
108 It should be taken into account when mbuf pool for receive is created.
109
110
111 Supported NICs
112 --------------
113
114 - Solarflare Flareon [Ultra] Server Adapters:
115
116    - Solarflare SFN8522 Dual Port SFP+ Server Adapter
117
118    - Solarflare SFN8542 Dual Port QSFP+ Server Adapter
119
120    - Solarflare SFN7002F Dual Port SFP+ Server Adapter
121
122    - Solarflare SFN7004F Quad Port SFP+ Server Adapter
123
124    - Solarflare SFN7042Q Dual Port QSFP+ Server Adapter
125
126    - Solarflare SFN7122F Dual Port SFP+ Server Adapter
127
128    - Solarflare SFN7124F Quad Port SFP+ Server Adapter
129
130    - Solarflare SFN7142Q Dual Port QSFP+ Server Adapter
131
132    - Solarflare SFN7322F Precision Time Synchronization Server Adapter
133
134
135 Prerequisites
136 -------------
137
138 - Requires firmware version:
139
140    - SFN7xxx: **4.7.1.1001** or higher
141
142    - SFN8xxx: **6.0.2.1004** or higher
143
144 Visit `Solarflare Support Downloads <https://support.solarflare.com>`_ to get
145 Solarflare Utilities (either Linux or FreeBSD) with the latest firmware.
146 Follow instructions from Solarflare Server Adapter User's Guide to
147 update firmware and configure the adapter.
148
149
150 Pre-Installation Configuration
151 ------------------------------
152
153
154 Config File Options
155 ~~~~~~~~~~~~~~~~~~~
156
157 The following options can be modified in the ``.config`` file.
158 Please note that enabling debugging options may affect system performance.
159
160 - ``CONFIG_RTE_LIBRTE_SFC_EFX_PMD`` (default **y**)
161
162   Enable compilation of Solarflare libefx-based poll-mode driver.
163
164 - ``CONFIG_RTE_LIBRTE_SFC_EFX_DEBUG`` (default **n**)
165
166   Enable compilation of the extra run-time consistency checks.
167
168
169 Per-Device Parameters
170 ~~~~~~~~~~~~~~~~~~~~~
171
172 The following per-device parameters can be passed via EAL PCI device
173 whitelist option like "-w 02:00.0,arg1=value1,...".
174
175 Case-insensitive 1/y/yes/on or 0/n/no/off may be used to specify
176 boolean parameters value.
177
178 - ``perf_profile`` [auto|throughput|low-latency] (default **throughput**)
179
180   Choose hardware tunning to be optimized for either throughput or
181   low-latency.
182   **auto** allows NIC firmware to make a choice based on
183   installed licences and firmware variant configured using **sfboot**.
184
185 - ``debug_init`` [bool] (default **n**)
186
187   Enable extra logging during device intialization and startup.
188
189 - ``mcdi_logging`` [bool] (default **n**)
190
191   Enable extra logging of the communication with the NIC's management CPU.