ethdev: remove legacy FDIR filter type support
[dpdk.git] / doc / guides / nics / i40e.rst
index 50d5e36..828a259 100644 (file)
@@ -1,44 +1,19 @@
-..  BSD LICENSE
-    Copyright(c) 2016 Intel Corporation. All rights reserved.
-    All rights reserved.
-
-    Redistribution and use in source and binary forms, with or without
-    modification, are permitted provided that the following conditions
-    are met:
-
-    * Redistributions of source code must retain the above copyright
-    notice, this list of conditions and the following disclaimer.
-    * Redistributions in binary form must reproduce the above copyright
-    notice, this list of conditions and the following disclaimer in
-    the documentation and/or other materials provided with the
-    distribution.
-    * Neither the name of Intel Corporation nor the names of its
-    contributors may be used to endorse or promote products derived
-    from this software without specific prior written permission.
-
-    THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
-    "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
-    LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
-    A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
-    OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
-    SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
-    LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
-    DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
-    THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
-    (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
-    OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
+..  SPDX-License-Identifier: BSD-3-Clause
+    Copyright(c) 2016 Intel Corporation.
 
 I40E Poll Mode Driver
 ======================
 
-The I40E PMD (librte_pmd_i40e) provides poll mode driver support
-for the Intel X710/XL710/X722 10/40 Gbps family of adapters.
+The i40e PMD (**librte_net_i40e**) provides poll mode driver support for
+10/25/40 Gbps Intel® Ethernet 700 Series Network Adapters based on
+the Intel Ethernet Controller X710/XL710/XXV710 and Intel Ethernet
+Connection X722 (only support part of features).
 
 
 Features
 --------
 
-Features of the I40E PMD are:
+Features of the i40e PMD are:
 
 - Multiple queues for TX and RX
 - Receiver Side Scaling (RSS)
@@ -66,7 +41,10 @@ Features of the I40E PMD are:
 - IEEE1588/802.1AS timestamping
 - VF Daemon (VFD) - EXPERIMENTAL
 - Dynamic Device Personalization (DDP)
-
+- Queue region configuration
+- Virtual Function Port Representors
+- Malicious Device Drive event catch and notify
+- Generic flow API
 
 Prerequisites
 -------------
@@ -80,7 +58,96 @@ Prerequisites
   section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
 
 - Upgrade the NVM/FW version following the `Intel® Ethernet NVM Update Tool Quick Usage Guide for Linux
-  <https://www-ssl.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-linux-usage-guide.html>`_ if needed.
+  <https://www-ssl.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-linux-usage-guide.html>`_ and `Intel® Ethernet NVM Update Tool: Quick Usage Guide for EFI <https://www.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-efi-usage-guide.html>`_ if needed.
+
+- For information about supported media, please refer to this document: `Intel® Ethernet Controller X710/XXV710/XL710 Feature Support Matrix
+  <http://www.intel.com/content/dam/www/public/us/en/documents/release-notes/xl710-ethernet-controller-feature-matrix.pdf>`_.
+
+   .. Note::
+
+      * Some adapters based on the Intel(R) Ethernet Controller 700 Series only
+        support Intel Ethernet Optics modules. On these adapters, other modules are not
+        supported and will not function.
+
+      * For connections based on Intel(R) Ethernet Controller 700 Series,
+        support is dependent on your system board. Please see your vendor for details.
+
+      * In all cases Intel recommends using Intel Ethernet Optics; other modules
+        may function but are not validated by Intel. Contact Intel for supported media types.
+
+Recommended Matching List
+-------------------------
+
+It is highly recommended to upgrade the i40e kernel driver and firmware to
+avoid the compatibility issues with i40e PMD. Here is the suggested matching
+list which has been tested and verified. The detailed information can refer
+to chapter Tested Platforms/Tested NICs in release notes.
+
+For X710/XL710/XXV710,
+
+   +--------------+-----------------------+------------------+
+   | DPDK version | Kernel driver version | Firmware version |
+   +==============+=======================+==================+
+   |    20.08     |         2.12.6        |       7.30       |
+   +--------------+-----------------------+------------------+
+   |    20.05     |         2.11.27       |       7.30       |
+   +--------------+-----------------------+------------------+
+   |    20.02     |         2.10.19       |       7.20       |
+   +--------------+-----------------------+------------------+
+   |    19.11     |         2.9.21        |       7.00       |
+   +--------------+-----------------------+------------------+
+   |    19.08     |         2.8.43        |       7.00       |
+   +--------------+-----------------------+------------------+
+   |    19.05     |         2.7.29        |       6.80       |
+   +--------------+-----------------------+------------------+
+   |    19.02     |         2.7.26        |       6.80       |
+   +--------------+-----------------------+------------------+
+   |    18.11     |         2.4.6         |       6.01       |
+   +--------------+-----------------------+------------------+
+   |    18.08     |         2.4.6         |       6.01       |
+   +--------------+-----------------------+------------------+
+   |    18.05     |         2.4.6         |       6.01       |
+   +--------------+-----------------------+------------------+
+   |    18.02     |         2.4.3         |       6.01       |
+   +--------------+-----------------------+------------------+
+   |    17.11     |         2.1.26        |       6.01       |
+   +--------------+-----------------------+------------------+
+   |    17.08     |         2.0.19        |       6.01       |
+   +--------------+-----------------------+------------------+
+   |    17.05     |         1.5.23        |       5.05       |
+   +--------------+-----------------------+------------------+
+   |    17.02     |         1.5.23        |       5.05       |
+   +--------------+-----------------------+------------------+
+   |    16.11     |         1.5.23        |       5.05       |
+   +--------------+-----------------------+------------------+
+   |    16.07     |         1.4.25        |       5.04       |
+   +--------------+-----------------------+------------------+
+   |    16.04     |         1.4.25        |       5.02       |
+   +--------------+-----------------------+------------------+
+
+
+For X722,
+
+   +--------------+-----------------------+------------------+
+   | DPDK version | Kernel driver version | Firmware version |
+   +==============+=======================+==================+
+   |    20.08     |         2.12.6        |       4.11       |
+   +--------------+-----------------------+------------------+
+   |    20.05     |         2.11.27       |       4.11       |
+   +--------------+-----------------------+------------------+
+   |    20.02     |         2.10.19       |       4.11       |
+   +--------------+-----------------------+------------------+
+   |    19.11     |         2.9.21        |       4.10       |
+   +--------------+-----------------------+------------------+
+   |    19.08     |         2.9.21        |       4.10       |
+   +--------------+-----------------------+------------------+
+   |    19.05     |         2.7.29        |       3.33       |
+   +--------------+-----------------------+------------------+
+   |    19.02     |         2.7.26        |       3.33       |
+   +--------------+-----------------------+------------------+
+   |    18.11     |         2.4.6         |       3.33       |
+   +--------------+-----------------------+------------------+
+
 
 Pre-Installation Configuration
 ------------------------------
@@ -88,54 +155,81 @@ Pre-Installation Configuration
 Config File Options
 ~~~~~~~~~~~~~~~~~~~
 
-The following options can be modified in the ``config`` file.
-Please note that enabling debugging options may affect system performance.
+The following options can be modified in the ``config/rte_config.h`` file.
 
-- ``CONFIG_RTE_LIBRTE_I40E_PMD`` (default ``y``)
+- ``RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
 
-  Toggle compilation of the ``librte_pmd_i40e`` driver.
+  Number of queues reserved for PF.
 
-- ``CONFIG_RTE_LIBRTE_I40E_DEBUG_*`` (default ``n``)
+- ``RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
 
-  Toggle display of generic debugging messages.
+  Number of queues reserved for each VMDQ Pool.
 
-- ``CONFIG_RTE_LIBRTE_I40E_RX_ALLOW_BULK_ALLOC`` (default ``y``)
+Runtime Config Options
+~~~~~~~~~~~~~~~~~~~~~~
 
-  Toggle bulk allocation for RX.
+- ``Reserved number of Queues per VF`` (default ``4``)
 
-- ``CONFIG_RTE_LIBRTE_I40E_INC_VECTOR`` (default ``n``)
+  The number of reserved queue per VF is determined by its host PF. If the
+  PCI address of an i40e PF is aaaa:bb.cc, the number of reserved queues per
+  VF can be configured with EAL parameter like -w aaaa:bb.cc,queue-num-per-vf=n.
+  The value n can be 1, 2, 4, 8 or 16. If no such parameter is configured, the
+  number of reserved queues per VF is 4 by default. If VF request more than
+  reserved queues per VF, PF will able to allocate max to 16 queues after a VF
+  reset.
 
-  Toggle the use of Vector PMD instead of normal RX/TX path.
-  To enable vPMD for RX, bulk allocation for Rx must be allowed.
 
-- ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` (default ``n``)
+- ``Support multiple driver`` (default ``disable``)
 
-  Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte.
+  There was a multiple driver support issue during use of 700 series Ethernet
+  Adapter with both Linux kernel and DPDK PMD. To fix this issue, ``devargs``
+  parameter ``support-multi-driver`` is introduced, for example::
 
-- ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
+    -w 84:00.0,support-multi-driver=1
 
-  Number of queues reserved for PF.
+  With the above configuration, DPDK PMD will not change global registers, and
+  will switch PF interrupt from IntN to Int0 to avoid interrupt conflict between
+  DPDK and Linux Kernel.
 
-- ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
+- ``Support VF Port Representor`` (default ``not enabled``)
 
-  Number of queues reserved for each VMDQ Pool.
+  The i40e PF PMD supports the creation of VF port representors for the control
+  and monitoring of i40e virtual function devices. Each port representor
+  corresponds to a single virtual function of that device. Using the ``devargs``
+  option ``representor`` the user can specify which virtual functions to create
+  port representors for on initialization of the PF PMD by passing the VF IDs of
+  the VFs which are required.::
 
-- ``CONFIG_RTE_LIBRTE_I40E_ITR_INTERVAL`` (default ``-1``)
+  -w DBDF,representor=[0,1,4]
 
-  Interrupt Throttling interval.
+  Currently hot-plugging of representor ports is not supported so all required
+  representors must be specified on the creation of the PF.
 
+- ``Use latest supported vector`` (default ``disable``)
 
-Runtime Config Options
-~~~~~~~~~~~~~~~~~~~~~~
+  Latest supported vector path may not always get the best perf so vector path was
+  recommended to use only on later platform. But users may want the latest vector path
+  since it can get better perf in some real work loading cases. So ``devargs`` param
+  ``use-latest-supported-vec`` is introduced, for example::
 
-- ``Number of Queues per VF`` (default ``4``)
+  -w 84:00.0,use-latest-supported-vec=1
 
-  The number of queue per VF is determined by its host PF. If the PCI address
-  of an i40e PF is aaaa:bb.cc, the number of queues per VF can be configured
-  with EAL parameter like -w aaaa:bb.cc,queue-num-per-vf=n. The value n can be
-  1, 2, 4, 8 or 16. If no such parameter is configured, the number of queues
-  per VF is 4 by default.
+- ``Enable validation for VF message`` (default ``not enabled``)
 
+  The PF counts messages from each VF. If in any period of seconds the message
+  statistic from a VF exceeds maximal limitation, the PF will ignore any new message
+  from that VF for some seconds.
+  Format -- "maximal-message@period-seconds:ignore-seconds"
+  For example::
+
+  -w 84:00.0,vf_msg_cfg=80@120:180
+
+Vector RX Pre-conditions
+~~~~~~~~~~~~~~~~~~~~~~~~
+For Vector RX it is assumed that the number of descriptor rings will be a power
+of 2. With this pre-condition, the ring pointer can easily scroll back to the
+head after hitting the tail without a conditional check. In addition Vector RX
+can use this assumption to do a bit mask using ``ring_size - 1``.
 
 Driver compilation and testing
 ------------------------------
@@ -238,7 +332,7 @@ To start ``testpmd``, and add vlan 10 to port 0:
 
 .. code-block:: console
 
-    ./app/testpmd -l 0-15 -n 4 -- -i --forward-mode=mac
+    ./<build_dir>/app/dpdk-testpmd -l 0-15 -n 4 -- -i --forward-mode=mac
     ...
 
     testpmd> set promisc 0 off
@@ -273,16 +367,17 @@ Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``:
 
 .. code-block:: console
 
-   ./app/testpmd -l 0-15 -n 4 -- -i --disable-rss --pkt-filter-mode=perfect \
-                 --rxq=8 --txq=8 --nb-cores=8 --nb-ports=1
+   ./<build_dir>/app/dpdk-testpmd -l 0-15 -n 4 -- -i --disable-rss \
+                 --pkt-filter-mode=perfect --rxq=8 --txq=8 --nb-cores=8 \
+                 --nb-ports=1
 
 Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1:
 
 .. code-block:: console
 
-   testpmd> flow_director_filter 0 mode IP add flow ipv4-udp  \
-            src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \
-           fwd pf queue 1 fd_id 1
+   testpmd> flow create 0 ingress pattern eth / ipv4 src is 2.2.2.3 \
+            dst is 2.2.2.5 / udp src is 32 dst is 32 / end \
+            actions mark id 1 / queue index 1 / end
 
 Check the flow director status:
 
@@ -331,16 +426,10 @@ Check the flow director status:
      f_add:        0           f_remove:      0
 
 
-Delete all flow director rules on a port:
-
-.. code-block:: console
-
-   testpmd> flush_flow_director 0
-
 Floating VEB
 ~~~~~~~~~~~~~
 
-The Intel® Ethernet Controller X710 and XL710 Family support a feature called
+The Intel® Ethernet 700 Series support a feature called
 "Floating VEB".
 
 A Virtual Ethernet Bridge (VEB) is an IEEE Edge Virtual Bridging (EVB) term
@@ -386,25 +475,35 @@ or greater.
 Dynamic Device Personalization (DDP)
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 
-The Intel® Ethernet Controller X*710 support a feature called "Dynamic Device
-Personalization (DDP)", which is used to configure hardware by downloading
-a profile to support protocols/filters which are not supported by default.
-The DDP functionality requires a NIC firmware version of 6.0 or greater.
+The Intel® Ethernet 700 Series except for the Intel Ethernet Connection
+X722 support a feature called "Dynamic Device Personalization (DDP)",
+which is used to configure hardware by downloading a profile to support
+protocols/filters which are not supported by default. The DDP
+functionality requires a NIC firmware version of 6.0 or greater.
 
-Current implementation supports MPLSoUDP/MPLSoGRE/GTP-C/GTP-U/PPPoE/PPPoL2TP,
+Current implementation supports GTP-C/GTP-U/PPPoE/PPPoL2TP/ESP,
 steering can be used with rte_flow API.
 
-Load a profile which supports MPLSoUDP/MPLSoGRE:
+GTPv1 package is released, and it can be downloaded from
+https://downloadcenter.intel.com/download/27587.
+
+PPPoE package is released, and it can be downloaded from
+https://downloadcenter.intel.com/download/28040.
+
+ESP-AH package is released, and it can be downloaded from
+https://downloadcenter.intel.com/download/29446.
+
+Load a profile which supports GTP and store backup profile:
 
 .. code-block:: console
 
-   testpmd> ddp add 0 ./mpls.pkgo
+   testpmd> ddp add 0 ./gtp.pkgo,./backup.pkgo
 
-Delete a MPLS profile:
+Delete a GTP profile and restore backup profile:
 
 .. code-block:: console
 
-   testpmd> ddp del 0 ./mpls.pkgo
+   testpmd> ddp del 0 ./backup.pkgo
 
 Get loaded DDP package info list:
 
@@ -412,11 +511,11 @@ Get loaded DDP package info list:
 
    testpmd> ddp get list 0
 
-Display information about a MPLS profile:
+Display information about a GTP profile:
 
 .. code-block:: console
 
-   testpmd> ddp get info ./mpls.pkgo
+   testpmd> ddp get info ./gtp.pkgo
 
 Input set configuration
 ~~~~~~~~~~~~~~~~~~~~~~~
@@ -430,11 +529,70 @@ For example, to use only 48bit prefix for IPv6 src address for IPv6 TCP RSS:
    testpmd> port config 0 pctype 43 hash_inset set field 14
    testpmd> port config 0 pctype 43 hash_inset set field 15
 
+Queue region configuration
+~~~~~~~~~~~~~~~~~~~~~~~~~~~
+The Intel® Ethernet 700 Series supports a feature of queue regions
+configuration for RSS in the PF, so that different traffic classes or
+different packet classification types can be separated to different
+queues in different queue regions. There is an API for configuration
+of queue regions in RSS with a command line. It can parse the parameters
+of the region index, queue number, queue start index, user priority, traffic
+classes and so on. Depending on commands from the command line, it will call
+i40e private APIs and start the process of setting or flushing the queue
+region configuration. As this feature is specific for i40e only private
+APIs are used. These new ``test_pmd`` commands are as shown below. For
+details please refer to :doc:`../testpmd_app_ug/index`.
+
+.. code-block:: console
+
+   testpmd> set port (port_id) queue-region region_id (value) \
+               queue_start_index (value) queue_num (value)
+   testpmd> set port (port_id) queue-region region_id (value) flowtype (value)
+   testpmd> set port (port_id) queue-region UP (value) region_id (value)
+   testpmd> set port (port_id) queue-region flush (on|off)
+   testpmd> show port (port_id) queue-region
+
+Generic flow API
+~~~~~~~~~~~~~~~~~~~
+
+- ``RSS Flow``
+
+  RSS Flow supports to set hash input set, hash function, enable hash
+  and configure queue region.
+  For example:
+  Configure queue region as queue 0, 1, 2, 3.
+
+  .. code-block:: console
+
+    testpmd> flow create 0 ingress pattern end actions rss types end \
+      queues 0 1 2 3 end / end
+
+  Enable hash and set input set for ipv4-tcp.
+
+  .. code-block:: console
+
+    testpmd> flow create 0 ingress pattern eth / ipv4 / tcp / end \
+      actions rss types ipv4-tcp l3-src-only end queues end / end
+
+  Set symmetric hash enable for flow type ipv4-tcp.
+
+  .. code-block:: console
+
+    testpmd> flow create 0 ingress pattern eth / ipv4 / tcp / end \
+      actions rss types ipv4-tcp end queues end func symmetric_toeplitz / end
+
+  Set hash function as simple xor.
+
+  .. code-block:: console
+
+    testpmd> flow create 0 ingress pattern end actions rss types end \
+      queues end func simple_xor / end
+
 Limitations or Known issues
 ---------------------------
 
-MPLS packet classification on X710/XL710
-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+MPLS packet classification
+~~~~~~~~~~~~~~~~~~~~~~~~~~
 
 For firmware versions prior to 5.0, MPLS packets are not recognized by the NIC.
 The L2 Payload flow type in flow director can be used to classify MPLS packet
@@ -450,8 +608,8 @@ L2 Payload flow type in flow director cannot be used to classify MPLS packet
 as with previous firmware versions. Meanwhile, the Ethertype filter can be
 used to classify MPLS packet by using a command in testpmd like:
 
-   testpmd> ethertype_filter 0 add mac_ignr 00:00:00:00:00:00 ethertype \
-            0x8847 fwd queue <M>
+   testpmd> flow create 0 ingress pattern eth type is 0x8847 / end \
+            actions queue index <M> / end
 
 16 Byte RX Descriptor setting on DPDK VF
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
@@ -463,8 +621,7 @@ For all available versions of the i40e driver, these drivers don't support 16
 byte RX descriptor. If the Linux i40e kernel driver is used as host driver,
 while DPDK i40e PMD is used as the VF driver, DPDK cannot choose 16 byte receive
 descriptor. The reason is that the RX descriptor is already set to 32 byte by
-the i40e kernel driver. That is to say, user should keep
-``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC=n`` in config file.
+the i40e kernel driver.
 In the future, if the Linux i40e driver supports 16 byte RX descriptor, user
 should make sure the DPDK VF uses the same RX descriptor mode, 16 byte or 32
 byte, as the PF driver.
@@ -482,14 +639,23 @@ Incorrect Rx statistics when packet is oversize
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 
 When a packet is over maximum frame size, the packet is dropped.
-However the Rx statistics, when calling `rte_eth_stats_get` incorrectly
+However, the Rx statistics, when calling `rte_eth_stats_get` incorrectly
 shows it as received.
 
+RX/TX statistics may be incorrect when register overflowed
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+The rx_bytes/tx_bytes statistics register is 48 bit length.
+Although this limitation is enlarged to 64 bit length on the software side,
+but there is no way to detect if the overflow occurred more than once.
+So rx_bytes/tx_bytes statistics data is correct when statistics are
+updated at least once between two overflows.
+
 VF & TC max bandwidth setting
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 
 The per VF max bandwidth and per TC max bandwidth cannot be enabled in parallel.
-The dehavior is different when handling per VF and per TC max bandwidth setting.
+The behavior is different when handling per VF and per TC max bandwidth setting.
 When enabling per VF max bandwidth, SW will check if per TC max bandwidth is
 enabled. If so, return failure.
 When enabling per TC max bandwidth, SW will check if per VF max bandwidth
@@ -499,7 +665,7 @@ bandwidth setting.
 TC TX scheduling mode setting
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 
-There're 2 TX scheduling modes for TCs, round robin and strict priority mode.
+There are 2 TX scheduling modes for TCs, round robin and strict priority mode.
 If a TC is set to strict priority mode, it can consume unlimited bandwidth.
 It means if APP has set the max bandwidth for that TC, it comes to no
 effect.
@@ -510,11 +676,11 @@ VF performance is impacted by PCI extended tag setting
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 
 To reach maximum NIC performance in the VF the PCI extended tag must be
-enabled. The DPDK I40E PF driver will set this feature during initialization,
+enabled. The DPDK i40e PF driver will set this feature during initialization,
 but the kernel PF driver does not. So when running traffic on a VF which is
 managed by the kernel PF driver, a significant NIC performance downgrade has
-been observed (for 64 byte packets, there is about 25% linerate downgrade for
-a 25G device and about 35% for a 40G device).
+been observed (for 64 byte packets, there is about 25% line-rate downgrade for
+a 25GbE device and about 35% for a 40GbE device).
 
 For kernel version >= 4.11, the kernel's PCI driver will enable the extended
 tag if it detects that the device supports it. So by default, this is not an
@@ -543,12 +709,31 @@ DCB function
 
 DCB works only when RSS is enabled.
 
-High Performance of Small Packets on 40G NIC
---------------------------------------------
+Global configuration warning
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+I40E PMD will set some global registers to enable some function or set some
+configure. Then when using different ports of the same NIC with Linux kernel
+and DPDK, the port with Linux kernel will be impacted by the port with DPDK.
+For example, register I40E_GL_SWT_L2TAGCTRL is used to control L2 tag, i40e
+PMD uses I40E_GL_SWT_L2TAGCTRL to set vlan TPID. If setting TPID in port A
+with DPDK, then the configuration will also impact port B in the NIC with
+kernel driver, which don't want to use the TPID.
+So PMD reports warning to clarify what is changed by writing global register.
+
+Cloud Filter
+~~~~~~~~~~~~
+
+When programming cloud filters for IPv4/6_UDP/TCP/SCTP with SRC port only or DST port only,
+it will make any cloud filter using inner_vlan or tunnel key invalid. Default configuration will be
+recovered only by NIC core reset.
+
+High Performance of Small Packets on 40GbE NIC
+----------------------------------------------
 
 As there might be firmware fixes for performance enhancement in latest version
 of firmware image, the firmware update might be needed for getting high performance.
-Check with the local Intel's Network Division application engineers for firmware updates.
+Check the Intel support website for the latest firmware updates.
 Users should consult the release notes specific to a DPDK release to identify
 the validated firmware version for a NIC using the i40e driver.
 
@@ -556,25 +741,26 @@ Use 16 Bytes RX Descriptor Size
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 
 As i40e PMD supports both 16 and 32 bytes RX descriptor sizes, and 16 bytes size can provide helps to high performance of small packets.
-Configuration of ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` in config files can be changed to use 16 bytes size RX descriptors.
+In ``config/rte_config.h`` set the following to use 16 bytes size RX descriptors::
 
-High Performance and per Packet Latency Tradeoff
-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+   #define RTE_LIBRTE_I40E_16BYTE_RX_DESC 1
 
-Due to the hardware design, the interrupt signal inside NIC is needed for per
-packet descriptor write-back. The minimum interval of interrupts could be set
-at compile time by ``CONFIG_RTE_LIBRTE_I40E_ITR_INTERVAL`` in configuration files.
-Though there is a default configuration, the interval could be tuned by the
-users with that configuration item depends on what the user cares about more,
-performance or per packet latency.
+Input set requirement of each pctype for FDIR
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+Each PCTYPE can only have one specific FDIR input set at one time.
+For example, if creating 2 rte_flow rules with different input set for one PCTYPE,
+it will fail and return the info "Conflict with the first rule's input set",
+which means the current rule's input set conflicts with the first rule's.
+Remove the first rule if want to change the input set of the PCTYPE.
 
 Example of getting best performance with l3fwd example
 ------------------------------------------------------
 
-The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with an
-Intel server platform and Intel XL710 NICs.
+The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with a
+server with Intel Xeon processors and Intel Ethernet CNA XL710.
 
-The example scenario is to get best performance with two Intel XL710 40GbE ports.
+The example scenario is to get best performance with two Intel Ethernet CNA XL710 40GbE ports.
 See :numref:`figure_intel_perf_test_setup` for the performance test setup.
 
 .. _figure_intel_perf_test_setup:
@@ -584,9 +770,9 @@ See :numref:`figure_intel_perf_test_setup` for the performance test setup.
    Performance Test Setup
 
 
-1. Add two Intel XL710 NICs to the platform, and use one port per card to get best performance.
-   The reason for using two NICs is to overcome a PCIe Gen3's limitation since it cannot provide 80G bandwidth
-   for two 40G ports, but two different PCIe Gen3 x8 slot can.
+1. Add two Intel Ethernet CNA XL710 to the platform, and use one port per card to get best performance.
+   The reason for using two NICs is to overcome a PCIe v3.0 limitation since it cannot provide 80GbE bandwidth
+   for two 40GbE ports, but two different PCIe v3.0 x8 slot can.
    Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
 
       82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
@@ -602,7 +788,7 @@ See :numref:`figure_intel_perf_test_setup` for the performance test setup.
 
 4. Bind these two ports to igb_uio.
 
-5. As to XL710 40G port, we need at least two queue pairs to achieve best performance, then two queues per port
+5. As to Intel Ethernet CNA XL710 40GbE port, we need at least two queue pairs to achieve best performance, then two queues per port
    will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
 
 6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
@@ -610,7 +796,7 @@ See :numref:`figure_intel_perf_test_setup` for the performance test setup.
 
 7. The command line of running l3fwd would be something like the following::
 
-      ./l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \
+      ./dpdk-l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \
               -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
 
    This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
@@ -621,3 +807,9 @@ See :numref:`figure_intel_perf_test_setup` for the performance test setup.
    * Start creating a stream on packet generator.
 
    * Set the Ethernet II type to 0x0800.
+
+Tx bytes affected by the link status change
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+For firmware versions prior to 6.01 for X710 series and 3.33 for X722 series, the tx_bytes statistics data is affected by
+the link down event. Each time the link status changes to down, the tx_bytes decreases 110 bytes.