 #include <math.h>
 
+#include <rte_tailq.h>
+#include <rte_malloc.h>
 #include <rte_mtr.h>
 #include <rte_mtr_driver.h>
 
+#include <mlx5_devx_cmds.h>
+
 #include "mlx5.h"
+#include "mlx5_flow.h"
+
+/**
+ * Create the meter action.
+ *
+ * @param priv
+ *   Pointer to mlx5_priv.
+ * @param[in] fm
+ *   Pointer to flow meter to be converted.
+ *
+ * @return
+ *   Pointer to the meter action on success, NULL otherwise.
+ */
+static void *
+mlx5_flow_meter_action_create(struct mlx5_priv *priv,
+                             struct mlx5_flow_meter *fm)
+{
+#ifdef HAVE_MLX5_DR_CREATE_ACTION_FLOW_METER
+       struct mlx5dv_dr_flow_meter_attr mtr_init;
+       void *attr = fm->mfts->fmp;
+       struct mlx5_flow_meter_srtcm_rfc2697_prm *srtcm =
+                                                    &fm->profile->srtcm_prm;
+
+       fm->mfts->fmp_size = MLX5_ST_SZ_BYTES(flow_meter_parameters);
+       memset(attr, 0, fm->mfts->fmp_size);
+       MLX5_SET(flow_meter_parameters, attr, valid, 1);
+       MLX5_SET(flow_meter_parameters, attr, bucket_overflow, 1);
+       MLX5_SET(flow_meter_parameters, attr,
+                start_color, MLX5_FLOW_COLOR_GREEN);
+       MLX5_SET(flow_meter_parameters, attr, both_buckets_on_green, 0);
+       MLX5_SET(flow_meter_parameters,
+                attr, cbs_exponent, srtcm->cbs_exponent);
+       MLX5_SET(flow_meter_parameters,
+                attr, cbs_mantissa, srtcm->cbs_mantissa);
+       MLX5_SET(flow_meter_parameters,
+                attr, cir_exponent, srtcm->cir_exponent);
+       MLX5_SET(flow_meter_parameters,
+                attr, cir_mantissa, srtcm->cir_mantissa);
+       MLX5_SET(flow_meter_parameters,
+                attr, ebs_exponent, srtcm->ebs_exponent);
+       MLX5_SET(flow_meter_parameters,
+                attr, ebs_mantissa, srtcm->ebs_mantissa);
+       mtr_init.next_table =
+               fm->attr.transfer ? fm->mfts->transfer.tbl->obj :
+                   fm->attr.egress ? fm->mfts->egress.tbl->obj :
+                                      fm->mfts->ingress.tbl->obj;
+       mtr_init.reg_c_index = priv->mtr_color_reg - REG_C_0;
+       mtr_init.flow_meter_parameter = fm->mfts->fmp;
+       mtr_init.flow_meter_parameter_sz = fm->mfts->fmp_size;
+       mtr_init.active = fm->active_state;
+       return mlx5_glue->dv_create_flow_action_meter(&mtr_init);
+#else
+       (void)priv;
+       (void)fm;
+       return NULL;
+#endif
+}
+
+/**
+ * Find meter profile by id.
+ *
+ * @param priv
+ *   Pointer to mlx5_priv.
+ * @param meter_profile_id
+ *   Meter profile id.
+ *
+ * @return
+ *   Pointer to the profile found on success, NULL otherwise.
+ */
+static struct mlx5_flow_meter_profile *
+mlx5_flow_meter_profile_find(struct mlx5_priv *priv, uint32_t meter_profile_id)
+{
+       struct mlx5_mtr_profiles *fmps = &priv->flow_meter_profiles;
+       struct mlx5_flow_meter_profile *fmp;
+
+       TAILQ_FOREACH(fmp, fmps, next)
+               if (meter_profile_id == fmp->meter_profile_id)
+                       return fmp;
+       return NULL;
+}
+
+/**
+ * Validate the MTR profile.
+ *
+ * @param[in] dev
+ *   Pointer to Ethernet device.
+ * @param[in] meter_profile_id
+ *   Meter profile id.
+ * @param[in] profile
+ *   Pointer to meter profile detail.
+ * @param[out] error
+ *   Pointer to the error structure.
+ *
+ * @return
+ *   0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_profile_validate(struct rte_eth_dev *dev,
+                                uint32_t meter_profile_id,
+                                struct rte_mtr_meter_profile *profile,
+                                struct rte_mtr_error *error)
+{
+       struct mlx5_priv *priv = dev->data->dev_private;
+       struct mlx5_flow_meter_profile *fmp;
+
+       /* Profile must not be NULL. */
+       if (profile == NULL)
+               return -rte_mtr_error_set(error, EINVAL,
+                                         RTE_MTR_ERROR_TYPE_METER_PROFILE,
+                                         NULL, "Meter profile is null.");
+       /* Meter profile ID must be valid. */
+       if (meter_profile_id == UINT32_MAX)
+               return -rte_mtr_error_set(error, EINVAL,
+                                         RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
+                                         NULL, "Meter profile id not valid.");
+       /* Meter profile must not exist. */
+       fmp = mlx5_flow_meter_profile_find(priv, meter_profile_id);
+       if (fmp)
+               return -rte_mtr_error_set(error, EEXIST,
+                                         RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
+                                         NULL,
+                                         "Meter profile already exists.");
+       if (profile->alg == RTE_MTR_SRTCM_RFC2697) {
+               if (priv->config.hca_attr.qos.srtcm_sup) {
+                       /* Verify support for flow meter parameters. */
+                       if (profile->srtcm_rfc2697.cir > 0 &&
+                           profile->srtcm_rfc2697.cir <= MLX5_SRTCM_CIR_MAX &&
+                           profile->srtcm_rfc2697.cbs > 0 &&
+                           profile->srtcm_rfc2697.cbs <= MLX5_SRTCM_CBS_MAX &&
+                           profile->srtcm_rfc2697.ebs <= MLX5_SRTCM_EBS_MAX)
+                               return 0;
+                       else
+                               return -rte_mtr_error_set
+                                            (error, ENOTSUP,
+                                             RTE_MTR_ERROR_TYPE_MTR_PARAMS,
+                                             NULL,
+                                             profile->srtcm_rfc2697.ebs ?
+                                             "Metering value ebs must be 0." :
+                                             "Invalid metering parameters.");
+               }
+       }
+       return -rte_mtr_error_set(error, ENOTSUP,
+                                 RTE_MTR_ERROR_TYPE_METER_PROFILE,
+                                 NULL, "Metering algorithm not supported.");
+}
+
+/**
+ * Calculate mantissa and exponent for cir.
+ *
+ * @param[in] cir
+ *   Value to be calculated.
+ * @param[out] man
+ *   Pointer to the mantissa.
+ * @param[out] exp
+ *   Pointer to the exp.
+ */
+static void
+mlx5_flow_meter_cir_man_exp_calc(int64_t cir, uint8_t *man, uint8_t *exp)
+{
+       int64_t _cir;
+       int64_t delta = INT64_MAX;
+       uint8_t _man = 0;
+       uint8_t _exp = 0;
+       uint64_t m, e;
+
+       for (m = 0; m <= 0xFF; m++) { /* man width 8 bit */
+               for (e = 0; e <= 0x1F; e++) { /* exp width 5bit */
+                       _cir = (1000000000ULL * m) >> e;
+                       if (llabs(cir - _cir) <= delta) {
+                               delta = llabs(cir - _cir);
+                               _man = m;
+                               _exp = e;
+                       }
+               }
+       }
+       *man = _man;
+       *exp = _exp;
+}
+
+/**
+ * Calculate mantissa and exponent for xbs.
+ *
+ * @param[in] xbs
+ *   Value to be calculated.
+ * @param[out] man
+ *   Pointer to the mantissa.
+ * @param[out] exp
+ *   Pointer to the exp.
+ */
+static void
+mlx5_flow_meter_xbs_man_exp_calc(uint64_t xbs, uint8_t *man, uint8_t *exp)
+{
+       int _exp;
+       double _man;
+
+       /* Special case xbs == 0 ? both exp and matissa are 0. */
+       if (xbs == 0) {
+               *man = 0;
+               *exp = 0;
+               return;
+       }
+       /* xbs = xbs_mantissa * 2^xbs_exponent */
+       _man = frexp(xbs, &_exp);
+       _man = _man * pow(2, MLX5_MAN_WIDTH);
+       _exp = _exp - MLX5_MAN_WIDTH;
+       *man = (uint8_t)ceil(_man);
+       *exp = _exp;
+}
+
+/**
+ * Fill the prm meter parameter.
+ *
+ * @param[in,out] fmp
+ *   Pointer to meter profie to be converted.
+ * @param[out] error
+ *   Pointer to the error structure.
+ *
+ * @return
+ *   0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_param_fill(struct mlx5_flow_meter_profile *fmp,
+                         struct rte_mtr_error *error)
+{
+       struct mlx5_flow_meter_srtcm_rfc2697_prm *srtcm = &fmp->srtcm_prm;
+       uint8_t man, exp;
+
+       if (fmp->profile.alg != RTE_MTR_SRTCM_RFC2697)
+               return -rte_mtr_error_set(error, ENOTSUP,
+                               RTE_MTR_ERROR_TYPE_METER_PROFILE,
+                               NULL, "Metering algorithm not supported.");
+        /* cbs = cbs_mantissa * 2^cbs_exponent */
+       mlx5_flow_meter_xbs_man_exp_calc(fmp->profile.srtcm_rfc2697.cbs,
+                                   &man, &exp);
+       srtcm->cbs_mantissa = man;
+       srtcm->cbs_exponent = exp;
+       /* Check if cbs mantissa is too large. */
+       if (srtcm->cbs_exponent != exp)
+               return -rte_mtr_error_set(error, EINVAL,
+                                         RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL,
+                                         "Metering profile parameter cbs is"
+                                         " invalid.");
+       /* ebs = ebs_mantissa * 2^ebs_exponent */
+       mlx5_flow_meter_xbs_man_exp_calc(fmp->profile.srtcm_rfc2697.ebs,
+                                   &man, &exp);
+       srtcm->ebs_mantissa = man;
+       srtcm->ebs_exponent = exp;
+       /* Check if ebs mantissa is too large. */
+       if (srtcm->ebs_exponent != exp)
+               return -rte_mtr_error_set(error, EINVAL,
+                                         RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL,
+                                         "Metering profile parameter ebs is"
+                                         " invalid.");
+       /* cir = 8G * cir_mantissa * 1/(2^cir_exponent)) Bytes/Sec */
+       mlx5_flow_meter_cir_man_exp_calc(fmp->profile.srtcm_rfc2697.cir,
+                                   &man, &exp);
+       srtcm->cir_mantissa = man;
+       srtcm->cir_exponent = exp;
+       /* Check if cir mantissa is too large. */
+       if (srtcm->cir_exponent != exp)
+               return -rte_mtr_error_set(error, EINVAL,
+                                         RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL,
+                                         "Metering profile parameter cir is"
+                                         " invalid.");
+       return 0;
+}
+
+/**
+ * Callback to get MTR capabilities.
+ *
+ * @param[in] dev
+ *   Pointer to Ethernet device.
+ * @param[out] cap
+ *   Pointer to save MTR capabilities.
+ * @param[out] error
+ *   Pointer to the error structure.
+ *
+ * @return
+ *   0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_mtr_cap_get(struct rte_eth_dev *dev,
+                struct rte_mtr_capabilities *cap,
+                struct rte_mtr_error *error __rte_unused)
+{
+       struct mlx5_priv *priv = dev->data->dev_private;
+       struct mlx5_hca_qos_attr *qattr = &priv->config.hca_attr.qos;
+
+       if (!priv->mtr_en)
+               return -rte_mtr_error_set(error, ENOTSUP,
+                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+                                         "Meter is not support");
+       memset(cap, 0, sizeof(*cap));
+       cap->n_max = 1 << qattr->log_max_flow_meter;
+       cap->n_shared_max = cap->n_max;
+       cap->identical = 1;
+       cap->shared_identical = 1;
+       cap->shared_n_flows_per_mtr_max = 4 << 20;
+       /* 2M flows can share the same meter. */
+       cap->chaining_n_mtrs_per_flow_max = 1; /* Chaining is not supported. */
+       cap->meter_srtcm_rfc2697_n_max = qattr->srtcm_sup ? cap->n_max : 0;
+       cap->meter_rate_max = 1ULL << 40; /* 1 Tera tokens per sec. */
+       cap->policer_action_drop_supported = 1;
+       cap->stats_mask = RTE_MTR_STATS_N_BYTES_DROPPED |
+                         RTE_MTR_STATS_N_PKTS_DROPPED;
+       return 0;
+}
+
+/**
+ * Callback to add MTR profile.
+ *
+ * @param[in] dev
+ *   Pointer to Ethernet device.
+ * @param[in] meter_profile_id
+ *   Meter profile id.
+ * @param[in] profile
+ *   Pointer to meter profile detail.
+ * @param[out] error
+ *   Pointer to the error structure.
+ *
+ * @return
+ *   0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_profile_add(struct rte_eth_dev *dev,
+                      uint32_t meter_profile_id,
+                      struct rte_mtr_meter_profile *profile,
+                      struct rte_mtr_error *error)
+{
+       struct mlx5_priv *priv = dev->data->dev_private;
+       struct mlx5_mtr_profiles *fmps = &priv->flow_meter_profiles;
+       struct mlx5_flow_meter_profile *fmp;
+       int ret;
+
+       if (!priv->mtr_en)
+               return -rte_mtr_error_set(error, ENOTSUP,
+                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+                                         "Meter is not support");
+       /* Check input params. */
+       ret = mlx5_flow_meter_profile_validate(dev, meter_profile_id,
+                                              profile, error);
+       if (ret)
+               return ret;
+       /* Meter profile memory allocation. */
+       fmp = rte_calloc(__func__, 1, sizeof(struct mlx5_flow_meter_profile),
+                        RTE_CACHE_LINE_SIZE);
+       if (fmp == NULL)
+               return -rte_mtr_error_set(error, ENOMEM,
+                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED,
+                                         NULL, "Meter profile memory "
+                                         "alloc failed.");
+       /* Fill profile info. */
+       fmp->meter_profile_id = meter_profile_id;
+       fmp->profile = *profile;
+       /* Fill the flow meter parameters for the PRM. */
+       ret = mlx5_flow_meter_param_fill(fmp, error);
+       if (ret)
+               goto error;
+       /* Add to list. */
+       TAILQ_INSERT_TAIL(fmps, fmp, next);
+       return 0;
+error:
+       rte_free(fmp);
+       return ret;
+}
+
+/**
+ * Callback to delete MTR profile.
+ *
+ * @param[in] dev
+ *   Pointer to Ethernet device.
+ * @param[in] meter_profile_id
+ *   Meter profile id.
+ * @param[out] error
+ *   Pointer to the error structure.
+ *
+ * @return
+ *   0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_profile_delete(struct rte_eth_dev *dev,
+                         uint32_t meter_profile_id,
+                         struct rte_mtr_error *error)
+{
+       struct mlx5_priv *priv = dev->data->dev_private;
+       struct mlx5_flow_meter_profile *fmp;
+
+       if (!priv->mtr_en)
+               return -rte_mtr_error_set(error, ENOTSUP,
+                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+                                         "Meter is not support");
+       /* Meter profile must exist. */
+       fmp = mlx5_flow_meter_profile_find(priv, meter_profile_id);
+       if (fmp == NULL)
+               return -rte_mtr_error_set(error, ENOENT,
+                                         RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
+                                         &meter_profile_id,
+                                         "Meter profile id invalid.");
+       /* Check profile is unused. */
+       if (fmp->ref_cnt)
+               return -rte_mtr_error_set(error, EBUSY,
+                                         RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
+                                         NULL, "Meter profile in use.");
+       /* Remove from list. */
+       TAILQ_REMOVE(&priv->flow_meter_profiles, fmp, next);
+       rte_free(fmp);
+       return 0;
+}
+
+/**
+ * Convert wrong color setting action to verbose error.
+ *
+ * @param[in] action
+ *   Policy color action.
+ *
+ * @return
+ *   Verbose meter color error type.
+ */
+static inline enum rte_mtr_error_type
+action2error(enum rte_mtr_policer_action action)
+{
+       switch (action) {
+       case MTR_POLICER_ACTION_COLOR_GREEN:
+               return RTE_MTR_ERROR_TYPE_POLICER_ACTION_GREEN;
+       case MTR_POLICER_ACTION_COLOR_YELLOW:
+               return RTE_MTR_ERROR_TYPE_POLICER_ACTION_YELLOW;
+       case MTR_POLICER_ACTION_COLOR_RED:
+               return RTE_MTR_ERROR_TYPE_POLICER_ACTION_RED;
+       default:
+               break;
+       }
+       return RTE_MTR_ERROR_TYPE_UNSPECIFIED;
+}
+
+/**
+ * Check meter validation.
+ *
+ * @param[in] priv
+ *   Pointer to mlx5 private data structure.
+ * @param[in] meter_id
+ *   Meter id.
+ * @param[in] params
+ *   Pointer to rte meter parameters.
+ * @param[out] error
+ *   Pointer to rte meter error structure.
+ *
+ * @return
+ *   0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_validate(struct mlx5_priv *priv, uint32_t meter_id,
+                        struct rte_mtr_params *params,
+                        struct rte_mtr_error *error)
+{
+       static enum rte_mtr_policer_action
+                               valid_recol_action[RTE_COLORS] = {
+                                              MTR_POLICER_ACTION_COLOR_GREEN,
+                                              MTR_POLICER_ACTION_COLOR_YELLOW,
+                                              MTR_POLICER_ACTION_COLOR_RED };
+       int i;
+
+       /* Meter params must not be NULL. */
+       if (params == NULL)
+               return -rte_mtr_error_set(error, EINVAL,
+                                         RTE_MTR_ERROR_TYPE_MTR_PARAMS,
+                                         NULL, "Meter object params null.");
+       /* Previous meter color is not supported. */
+       if (params->use_prev_mtr_color)
+               return -rte_mtr_error_set(error, ENOTSUP,
+                                         RTE_MTR_ERROR_TYPE_MTR_PARAMS,
+                                         NULL,
+                                         "Previous meter color "
+                                         "not supported.");
+       /* Validate policer settings. */
+       for (i = 0; i < RTE_COLORS; i++)
+               if (params->action[i] != valid_recol_action[i] &&
+                   params->action[i] != MTR_POLICER_ACTION_DROP)
+                       return -rte_mtr_error_set
+                                       (error, ENOTSUP,
+                                        action2error(params->action[i]), NULL,
+                                        "Recolor action not supported.");
+       /* Validate meter id. */
+       if (mlx5_flow_meter_find(priv, meter_id))
+               return -rte_mtr_error_set(error, EEXIST,
+                                         RTE_MTR_ERROR_TYPE_MTR_ID, NULL,
+                                         "Meter object already exists.");
+       return 0;
+}
+
+/**
+ * Modify the flow meter action.
+ *
+ * @param[in] priv
+ *   Pointer to mlx5 private data structure.
+ * @param[in] fm
+ *   Pointer to flow meter to be modified.
+ * @param[in] srtcm
+ *   Pointer to meter srtcm description parameter.
+ * @param[in] modify_bits
+ *   The bit in srtcm to be updated.
+ * @param[in] active_state
+ *   The state to be updated.
+ * @return
+ *   0 on success, o negative value otherwise.
+ */
+static int
+mlx5_flow_meter_action_modify(struct mlx5_priv *priv,
+               struct mlx5_flow_meter *fm,
+               const struct mlx5_flow_meter_srtcm_rfc2697_prm *srtcm,
+               uint64_t modify_bits, uint32_t active_state)
+{
+#ifdef HAVE_MLX5_DR_CREATE_ACTION_FLOW_METER
+       uint32_t in[MLX5_ST_SZ_DW(flow_meter_parameters)] = { 0 };
+       uint32_t *attr;
+       struct mlx5dv_dr_flow_meter_attr mod_attr = { 0 };
+       int ret;
+
+       /* Fill command parameters. */
+       mod_attr.reg_c_index = priv->mtr_color_reg - REG_C_0;
+       mod_attr.flow_meter_parameter = in;
+       mod_attr.flow_meter_parameter_sz = fm->mfts->fmp_size;
+       if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_ACTIVE)
+               mod_attr.active = !!active_state;
+       else
+               mod_attr.active = 0;
+       attr = in;
+       if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS) {
+               MLX5_SET(flow_meter_parameters,
+                        attr, cbs_exponent, srtcm->cbs_exponent);
+               MLX5_SET(flow_meter_parameters,
+                        attr, cbs_mantissa, srtcm->cbs_mantissa);
+       }
+       if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR) {
+               MLX5_SET(flow_meter_parameters,
+                        attr, cir_exponent, srtcm->cir_exponent);
+               MLX5_SET(flow_meter_parameters,
+                        attr, cir_mantissa, srtcm->cir_mantissa);
+       }
+       if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_EBS) {
+               MLX5_SET(flow_meter_parameters,
+                        attr, ebs_exponent, srtcm->ebs_exponent);
+               MLX5_SET(flow_meter_parameters,
+                        attr, ebs_mantissa, srtcm->ebs_mantissa);
+       }
+       /* Apply modifications to meter only if it was created. */
+       if (fm->mfts->meter_action) {
+               ret = mlx5_glue->dv_modify_flow_action_meter
+                                       (fm->mfts->meter_action, &mod_attr,
+                                       rte_cpu_to_be_64(modify_bits));
+               if (ret)
+                       return ret;
+       }
+       /* Update succeedded modify meter parameters. */
+       if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_ACTIVE)
+               fm->active_state = !!active_state;
+       attr = fm->mfts->fmp;
+       if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS) {
+               MLX5_SET(flow_meter_parameters,
+                        attr, cbs_exponent, srtcm->cbs_exponent);
+               MLX5_SET(flow_meter_parameters,
+                        attr, cbs_mantissa, srtcm->cbs_mantissa);
+       }
+       if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR) {
+               MLX5_SET(flow_meter_parameters,
+                        attr, cir_exponent, srtcm->cir_exponent);
+               MLX5_SET(flow_meter_parameters,
+                        attr, cir_mantissa, srtcm->cir_mantissa);
+       }
+       if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_EBS) {
+               MLX5_SET(flow_meter_parameters,
+                        attr, ebs_exponent, srtcm->ebs_exponent);
+               MLX5_SET(flow_meter_parameters,
+                        attr, ebs_mantissa, srtcm->ebs_mantissa);
+       }
+
+       return 0;
+#else
+       (void)priv;
+       (void)fm;
+       (void)srtcm;
+       (void)modify_bits;
+       (void)active_state;
+       return -ENOTSUP;
+#endif
+}
+
+/**
+ * Create meter rules.
+ *
+ * @param[in] dev
+ *   Pointer to Ethernet device.
+ * @param[in] meter_id
+ *   Meter id.
+ * @param[in] params
+ *   Pointer to rte meter parameters.
+ * @param[in] shared
+ *   Meter shared with other flow or not.
+ * @param[out] error
+ *   Pointer to rte meter error structure.
+ *
+ * @return
+ *   0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_create(struct rte_eth_dev *dev, uint32_t meter_id,
+                      struct rte_mtr_params *params, int shared,
+                      struct rte_mtr_error *error)
+{
+       struct mlx5_priv *priv = dev->data->dev_private;
+       struct mlx5_flow_meters *fms = &priv->flow_meters;
+       struct mlx5_flow_meter_profile *fmp;
+       struct mlx5_flow_meter *fm;
+       const struct rte_flow_attr attr = {
+                               .ingress = 1,
+                               .egress = 1,
+                               .transfer = priv->config.dv_esw_en ? 1 : 0,
+                       };
+       int ret;
+       unsigned int i;
+
+       if (!priv->mtr_en)
+               return -rte_mtr_error_set(error, ENOTSUP,
+                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+                                         "Meter is not support");
+       /* Validate the parameters. */
+       ret = mlx5_flow_meter_validate(priv, meter_id, params, error);
+       if (ret)
+               return ret;
+       /* Meter profile must exist. */
+       fmp = mlx5_flow_meter_profile_find(priv, params->meter_profile_id);
+       if (fmp == NULL)
+               return -rte_mtr_error_set(error, ENOENT,
+                                         RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
+                                         NULL, "Meter profile id not valid.");
+       /* Allocate the flow meter memory. */
+       fm = rte_calloc(__func__, 1,
+                       sizeof(struct mlx5_flow_meter), RTE_CACHE_LINE_SIZE);
+       if (fm == NULL)
+               return -rte_mtr_error_set(error, ENOMEM,
+                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+                                         "Memory alloc failed for meter.");
+       /* Fill the flow meter parameters. */
+       fm->meter_id = meter_id;
+       fm->profile = fmp;
+       fm->params = *params;
+       /* Alloc policer counters. */
+       for (i = 0; i < RTE_DIM(fm->policer_stats.cnt); i++) {
+               fm->policer_stats.cnt[i] = mlx5_counter_alloc(dev);
+               if (!fm->policer_stats.cnt[i])
+                       goto error;
+       }
+       fm->mfts = mlx5_flow_create_mtr_tbls(dev, fm);
+       if (!fm->mfts)
+               goto error;
+       ret = mlx5_flow_create_policer_rules(dev, fm, &attr);
+       if (ret)
+               goto error;
+       /* Add to the flow meter list. */
+       TAILQ_INSERT_TAIL(fms, fm, next);
+       fm->active_state = 1; /* Config meter starts as active. */
+       fm->shared = !!shared;
+       fm->policer_stats.stats_mask = params->stats_mask;
+       fm->profile->ref_cnt++;
+       return 0;
+error:
+       mlx5_flow_destroy_policer_rules(dev, fm, &attr);
+       mlx5_flow_destroy_mtr_tbls(dev, fm->mfts);
+       /* Free policer counters. */
+       for (i = 0; i < RTE_DIM(fm->policer_stats.cnt); i++)
+               if (fm->policer_stats.cnt[i])
+                       mlx5_counter_free(dev, fm->policer_stats.cnt[i]);
+       rte_free(fm);
+       return -rte_mtr_error_set(error, -ret,
+                                 RTE_MTR_ERROR_TYPE_UNSPECIFIED,
+                                 NULL, "Failed to create devx meter.");
+}
+
+/**
+ * Destroy meter rules.
+ *
+ * @param[in] dev
+ *   Pointer to Ethernet device.
+ * @param[in] meter_id
+ *   Meter id.
+ * @param[out] error
+ *   Pointer to rte meter error structure.
+ *
+ * @return
+ *   0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_destroy(struct rte_eth_dev *dev, uint32_t meter_id,
+                       struct rte_mtr_error *error)
+{
+       struct mlx5_priv *priv = dev->data->dev_private;
+       struct mlx5_flow_meters *fms = &priv->flow_meters;
+       struct mlx5_flow_meter_profile *fmp;
+       struct mlx5_flow_meter *fm;
+       const struct rte_flow_attr attr = {
+                               .ingress = 1,
+                               .egress = 1,
+                               .transfer = priv->config.dv_esw_en ? 1 : 0,
+                       };
+       unsigned int i;
+
+       if (!priv->mtr_en)
+               return -rte_mtr_error_set(error, ENOTSUP,
+                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+                                         "Meter is not support");
+       /* Meter object must exist. */
+       fm = mlx5_flow_meter_find(priv, meter_id);
+       if (fm == NULL)
+               return -rte_mtr_error_set(error, ENOENT,
+                                         RTE_MTR_ERROR_TYPE_MTR_ID,
+                                         NULL, "Meter object id not valid.");
+       /* Meter object must not have any owner. */
+       if (fm->ref_cnt > 0)
+               return -rte_mtr_error_set(error, EBUSY,
+                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED,
+                                         NULL, "Meter object is being used.");
+       /* Get the meter profile. */
+       fmp = fm->profile;
+       RTE_ASSERT(fmp);
+       /* Update dependencies. */
+       fmp->ref_cnt--;
+       /* Remove from the flow meter list. */
+       TAILQ_REMOVE(fms, fm, next);
+       /* Free policer counters. */
+       for (i = 0; i < RTE_DIM(fm->policer_stats.cnt); i++)
+               if (fm->policer_stats.cnt[i])
+                       mlx5_counter_free(dev, fm->policer_stats.cnt[i]);
+       /* Free meter flow table */
+       mlx5_flow_destroy_policer_rules(dev, fm, &attr);
+       mlx5_flow_destroy_mtr_tbls(dev, fm->mfts);
+       rte_free(fm);
+       return 0;
+}
+
+/**
+ * Modify meter state.
+ *
+ * @param[in] priv
+ *   Pointer to mlx5 private data structure.
+ * @param[in] fm
+ *   Pointer to flow meter.
+ * @param[in] new_state
+ *   New state to update.
+ * @param[out] error
+ *   Pointer to rte meter error structure.
+ *
+ * @return
+ *   0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_modify_state(struct mlx5_priv *priv,
+                            struct mlx5_flow_meter *fm,
+                            uint32_t new_state,
+                            struct rte_mtr_error *error)
+{
+       static const struct mlx5_flow_meter_srtcm_rfc2697_prm srtcm = {
+               .cbs_exponent = 20,
+               .cbs_mantissa = 191,
+               .cir_exponent = 0,
+               .cir_mantissa = 200,
+               .ebs_exponent = 0,
+               .ebs_mantissa = 0,
+       };
+       uint64_t modify_bits = MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS |
+                              MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR;
+       int ret;
+
+       if (new_state == MLX5_FLOW_METER_DISABLE)
+               ret = mlx5_flow_meter_action_modify(priv, fm, &srtcm,
+                                                   modify_bits, 0);
+       else
+               ret = mlx5_flow_meter_action_modify(priv, fm,
+                                                  &fm->profile->srtcm_prm,
+                                                   modify_bits, 0);
+       if (ret)
+               return -rte_mtr_error_set(error, -ret,
+                                         RTE_MTR_ERROR_TYPE_MTR_PARAMS,
+                                         NULL,
+                                         new_state ?
+                                         "Failed to enable meter." :
+                                         "Failed to disable meter.");
+       return 0;
+}
+
+/**
+ * Callback to enable flow meter.
+ *
+ * @param[in] dev
+ *   Pointer to Ethernet device.
+ * @param[in] meter_id
+ *   Meter id.
+ * @param[out] error
+ *   Pointer to rte meter error structure.
+ *
+ * @return
+ *   0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_enable(struct rte_eth_dev *dev,
+                      uint32_t meter_id,
+                      struct rte_mtr_error *error)
+{
+       struct mlx5_priv *priv = dev->data->dev_private;
+       struct mlx5_flow_meter *fm;
+       int ret;
+
+       if (!priv->mtr_en)
+               return -rte_mtr_error_set(error, ENOTSUP,
+                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+                                         "Meter is not support");
+       /* Meter object must exist. */
+       fm = mlx5_flow_meter_find(priv, meter_id);
+       if (fm == NULL)
+               return -rte_mtr_error_set(error, ENOENT,
+                                         RTE_MTR_ERROR_TYPE_MTR_ID,
+                                         NULL, "Meter not found.");
+       if (fm->active_state == MLX5_FLOW_METER_ENABLE)
+               return 0;
+       ret = mlx5_flow_meter_modify_state(priv, fm, MLX5_FLOW_METER_ENABLE,
+                                          error);
+       if (!ret)
+               fm->active_state = MLX5_FLOW_METER_ENABLE;
+       return ret;
+}
+
+/**
+ * Callback to disable flow meter.
+ *
+ * @param[in] dev
+ *   Pointer to Ethernet device.
+ * @param[in] meter_id
+ *   Meter id.
+ * @param[out] error
+ *   Pointer to rte meter error structure.
+ *
+ * @return
+ *   0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_disable(struct rte_eth_dev *dev,
+                       uint32_t meter_id,
+                       struct rte_mtr_error *error)
+{
+       struct mlx5_priv *priv = dev->data->dev_private;
+       struct mlx5_flow_meter *fm;
+       int ret;
+
+       if (!priv->mtr_en)
+               return -rte_mtr_error_set(error, ENOTSUP,
+                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+                                         "Meter is not support");
+       /* Meter object must exist. */
+       fm = mlx5_flow_meter_find(priv, meter_id);
+       if (fm == NULL)
+               return -rte_mtr_error_set(error, ENOENT,
+                                         RTE_MTR_ERROR_TYPE_MTR_ID,
+                                         NULL, "Meter not found.");
+       if (fm->active_state == MLX5_FLOW_METER_DISABLE)
+               return 0;
+       ret = mlx5_flow_meter_modify_state(priv, fm, MLX5_FLOW_METER_DISABLE,
+                                          error);
+       if (!ret)
+               fm->active_state = MLX5_FLOW_METER_DISABLE;
+       return ret;
+}
+
+/**
+ * Callback to update meter profile.
+ *
+ * @param[in] dev
+ *   Pointer to Ethernet device.
+ * @param[in] meter_id
+ *   Meter id.
+ * @param[in] meter_profile_id
+ *   To be updated meter profile id.
+ * @param[out] error
+ *   Pointer to rte meter error structure.
+ *
+ * @return
+ *   0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_profile_update(struct rte_eth_dev *dev,
+                              uint32_t meter_id,
+                              uint32_t meter_profile_id,
+                              struct rte_mtr_error *error)
+{
+       struct mlx5_priv *priv = dev->data->dev_private;
+       struct mlx5_flow_meter_profile *fmp;
+       struct mlx5_flow_meter_profile *old_fmp;
+       struct mlx5_flow_meter *fm;
+       uint64_t modify_bits = MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS |
+                              MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR;
+       int ret;
+
+       if (!priv->mtr_en)
+               return -rte_mtr_error_set(error, ENOTSUP,
+                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+                                         "Meter is not support");
+       /* Meter profile must exist. */
+       fmp = mlx5_flow_meter_profile_find(priv, meter_profile_id);
+       if (fmp == NULL)
+               return -rte_mtr_error_set(error, ENOENT,
+                                         RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
+                                         NULL, "Meter profile not found.");
+       /* Meter object must exist. */
+       fm = mlx5_flow_meter_find(priv, meter_id);
+       if (fm == NULL)
+               return -rte_mtr_error_set(error, ENOENT,
+                                         RTE_MTR_ERROR_TYPE_MTR_ID,
+                                         NULL, "Meter not found.");
+       /* MTR object already set to meter profile id. */
+       old_fmp = fm->profile;
+       if (fmp == old_fmp)
+               return 0;
+       /* Update the profile. */
+       fm->profile = fmp;
+       /* Update meter params in HW (if not disabled). */
+       if (fm->active_state == MLX5_FLOW_METER_DISABLE)
+               return 0;
+       ret = mlx5_flow_meter_action_modify(priv, fm, &fm->profile->srtcm_prm,
+                                             modify_bits, fm->active_state);
+       if (ret) {
+               fm->profile = old_fmp;
+               return -rte_mtr_error_set(error, -ret,
+                                         RTE_MTR_ERROR_TYPE_MTR_PARAMS,
+                                         NULL, "Failed to update meter"
+                                         " parmeters in hardware.");
+       }
+       old_fmp->ref_cnt--;
+       fmp->ref_cnt++;
+       return 0;
+}
+
+/**
+ * Callback to update meter stats mask.
+ *
+ * @param[in] dev
+ *   Pointer to Ethernet device.
+ * @param[in] meter_id
+ *   Meter id.
+ * @param[in] stats_mask
+ *   To be updated stats_mask.
+ * @param[out] error
+ *   Pointer to rte meter error structure.
+ *
+ * @return
+ *   0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_stats_update(struct rte_eth_dev *dev,
+                            uint32_t meter_id,
+                            uint64_t stats_mask,
+                            struct rte_mtr_error *error)
+{
+       struct mlx5_priv *priv = dev->data->dev_private;
+       struct mlx5_flow_meter *fm;
+
+       if (!priv->mtr_en)
+               return -rte_mtr_error_set(error, ENOTSUP,
+                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+                                         "Meter is not support");
+       /* Meter object must exist. */
+       fm = mlx5_flow_meter_find(priv, meter_id);
+       if (fm == NULL)
+               return -rte_mtr_error_set(error, ENOENT,
+                                         RTE_MTR_ERROR_TYPE_MTR_ID,
+                                         NULL, "Meter object id not valid.");
+       fm->policer_stats.stats_mask = stats_mask;
+       return 0;
+}
+
+/**
+ * Callback to read meter statistics.
+ *
+ * @param[in] dev
+ *   Pointer to Ethernet device.
+ * @param[in] meter_id
+ *   Meter id.
+ * @param[out] stats
+ *   Pointer to store the statistics.
+ * @param[out] stats_mask
+ *   Pointer to store the stats_mask.
+ * @param[in] clear
+ *   Statistic to be cleared after read or not.
+ * @param[out] error
+ *   Pointer to rte meter error structure.
+ *
+ * @return
+ *   0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_stats_read(struct rte_eth_dev *dev,
+                          uint32_t meter_id,
+                          struct rte_mtr_stats *stats,
+                          uint64_t *stats_mask,
+                          int clear,
+                          struct rte_mtr_error *error)
+{
+       static uint64_t meter2mask[RTE_MTR_DROPPED + 1] = {
+               RTE_MTR_STATS_N_PKTS_GREEN | RTE_MTR_STATS_N_BYTES_GREEN,
+               RTE_MTR_STATS_N_PKTS_YELLOW | RTE_MTR_STATS_N_BYTES_YELLOW,
+               RTE_MTR_STATS_N_PKTS_RED | RTE_MTR_STATS_N_BYTES_RED,
+               RTE_MTR_STATS_N_PKTS_DROPPED | RTE_MTR_STATS_N_BYTES_DROPPED
+       };
+       struct mlx5_priv *priv = dev->data->dev_private;
+       struct mlx5_flow_meter *fm;
+       struct mlx5_flow_policer_stats *ps;
+       uint64_t pkts_dropped = 0;
+       uint64_t bytes_dropped = 0;
+       uint64_t pkts;
+       uint64_t bytes;
+       int i;
+       int ret = 0;
+
+       if (!priv->mtr_en)
+               return -rte_mtr_error_set(error, ENOTSUP,
+                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+                                         "Meter is not support");
+       /* Meter object must exist. */
+       fm = mlx5_flow_meter_find(priv, meter_id);
+       if (fm == NULL)
+               return -rte_mtr_error_set(error, ENOENT,
+                                         RTE_MTR_ERROR_TYPE_MTR_ID,
+                                         NULL, "Meter object id not valid.");
+       ps = &fm->policer_stats;
+       *stats_mask = ps->stats_mask;
+       for (i = 0; i < RTE_MTR_DROPPED; i++) {
+               if (*stats_mask & meter2mask[i]) {
+                       ret = mlx5_counter_query(dev, ps->cnt[i], clear, &pkts,
+                                                &bytes);
+                       if (ret)
+                               goto error;
+                       if (fm->params.action[i] == MTR_POLICER_ACTION_DROP) {
+                               pkts_dropped += pkts;
+                               bytes_dropped += bytes;
+                       }
+                       /* If need to read the packets, set it. */
+                       if ((1 << i) & (*stats_mask & meter2mask[i]))
+                               stats->n_pkts[i] = pkts;
+                       /* If need to read the bytes, set it. */
+                       if ((1 << (RTE_MTR_DROPPED + 1 + i)) &
+                          (*stats_mask & meter2mask[i]))
+                               stats->n_bytes[i] = bytes;
+               }
+       }
+       /* Dropped packets/bytes are treated differently. */
+       if (*stats_mask & meter2mask[i]) {
+               ret = mlx5_counter_query(dev, ps->cnt[i], clear, &pkts,
+                                        &bytes);
+               if (ret)
+                       goto error;
+               pkts += pkts_dropped;
+               bytes += bytes_dropped;
+               /* If need to read the packets, set it. */
+               if ((*stats_mask & meter2mask[i]) &
+                  RTE_MTR_STATS_N_PKTS_DROPPED)
+                       stats->n_pkts_dropped = pkts;
+               /* If need to read the bytes, set it. */
+               if ((*stats_mask & meter2mask[i]) &
+                  RTE_MTR_STATS_N_BYTES_DROPPED)
+                       stats->n_bytes_dropped = bytes;
+       }
+       return 0;
+error:
+       return -rte_mtr_error_set(error, ret, RTE_MTR_ERROR_TYPE_STATS, NULL,
+                                "Failed to read policer counters.");
+}
 
 static const struct rte_mtr_ops mlx5_flow_mtr_ops = {
-       .capabilities_get = NULL,
-       .meter_profile_add = NULL,
-       .meter_profile_delete = NULL,
-       .create = NULL,
-       .destroy = NULL,
-       .meter_enable = NULL,
-       .meter_disable = NULL,
-       .meter_profile_update = NULL,
+       .capabilities_get = mlx5_flow_mtr_cap_get,
+       .meter_profile_add = mlx5_flow_meter_profile_add,
+       .meter_profile_delete = mlx5_flow_meter_profile_delete,
+       .create = mlx5_flow_meter_create,
+       .destroy = mlx5_flow_meter_destroy,
+       .meter_enable = mlx5_flow_meter_enable,
+       .meter_disable = mlx5_flow_meter_disable,
+       .meter_profile_update = mlx5_flow_meter_profile_update,
        .meter_dscp_table_update = NULL,
        .policer_actions_update = NULL,
-       .stats_update = NULL,
-       .stats_read = NULL,
+       .stats_update = mlx5_flow_meter_stats_update,
+       .stats_read = mlx5_flow_meter_stats_read,
 };
 
 /**
@@ -41,3 +1117,171 @@ mlx5_flow_meter_ops_get(struct rte_eth_dev *dev __rte_unused, void *arg)
        *(const struct rte_mtr_ops **)arg = &mlx5_flow_mtr_ops;
        return 0;
 }
+
+/**
+ * Find meter by id.
+ *
+ * @param priv
+ *   Pointer to mlx5_priv.
+ * @param meter_id
+ *   Meter id.
+ *
+ * @return
+ *   Pointer to the profile found on success, NULL otherwise.
+ */
+struct mlx5_flow_meter *
+mlx5_flow_meter_find(struct mlx5_priv *priv, uint32_t meter_id)
+{
+       struct mlx5_flow_meters *fms = &priv->flow_meters;
+       struct mlx5_flow_meter *fm;
+
+       TAILQ_FOREACH(fm, fms, next)
+               if (meter_id == fm->meter_id)
+                       return fm;
+       return NULL;
+}
+
+/**
+ * Attach meter to flow.
+ * Unidirectional Meter creation can only be done
+ * when flow direction is known, i.e. when calling meter_attach.
+ *
+ * @param [in] priv
+ *  Pointer to mlx5 private data.
+ * @param [in] meter_id
+ *  Flow meter id.
+ * @param [in] attr
+ *  Pointer to flow attributes.
+ * @param [out] error
+ *  Pointer to error structure.
+ *
+ * @return the flow meter pointer, NULL otherwise.
+ */
+struct mlx5_flow_meter *
+mlx5_flow_meter_attach(struct mlx5_priv *priv, uint32_t meter_id,
+                      const struct rte_flow_attr *attr,
+                      struct rte_flow_error *error)
+{
+       struct mlx5_flow_meter *fm;
+
+       fm = mlx5_flow_meter_find(priv, meter_id);
+       if (fm == NULL) {
+               rte_flow_error_set(error, ENOENT,
+                                  RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
+                                  "Meter object id not valid");
+               goto error;
+       }
+       if (!fm->shared && fm->ref_cnt) {
+               DRV_LOG(ERR, "Cannot share a non-shared meter.");
+               rte_flow_error_set(error, EINVAL,
+                                 RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
+                                 "Meter can't be shared");
+               goto error;
+       }
+       if (!fm->ref_cnt++) {
+               RTE_ASSERT(!fm->mfts->meter_action);
+               fm->attr = *attr;
+               /* This also creates the meter object. */
+               fm->mfts->meter_action = mlx5_flow_meter_action_create(priv,
+                                                                      fm);
+               if (!fm->mfts->meter_action)
+                       goto error_detach;
+       } else {
+               RTE_ASSERT(fm->mfts->meter_action);
+               if (attr->transfer != fm->attr.transfer ||
+                   attr->ingress != fm->attr.ingress ||
+                   attr->egress != fm->attr.egress) {
+                       DRV_LOG(ERR, "meter I/O attributes do not "
+                               "match flow I/O attributes.");
+                       goto error_detach;
+               }
+       }
+       return fm;
+error_detach:
+       mlx5_flow_meter_detach(fm);
+       rte_flow_error_set(error, EINVAL, RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
+                         fm->mfts->meter_action ? "Meter attr not match" :
+                         "Meter action create failed");
+error:
+       return NULL;
+}
+
+/**
+ * Detach meter from flow.
+ *
+ * @param [in] fm
+ *  Pointer to flow meter.
+ */
+void
+mlx5_flow_meter_detach(struct mlx5_flow_meter *fm)
+{
+       const struct rte_flow_attr attr = { 0 };
+
+       RTE_ASSERT(fm->ref_cnt);
+       if (--fm->ref_cnt)
+               return;
+       if (fm->mfts->meter_action)
+               mlx5_glue->destroy_flow_action(fm->mfts->meter_action);
+       fm->mfts->meter_action = NULL;
+       fm->attr = attr;
+}
+
+/**
+ * Flush meter configuration.
+ *
+ * @param[in] dev
+ *   Pointer to Ethernet device.
+ * @param[out] error
+ *   Pointer to rte meter error structure.
+ *
+ * @return
+ *   0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+int
+mlx5_flow_meter_flush(struct rte_eth_dev *dev, struct rte_mtr_error *error)
+{
+       struct mlx5_priv *priv = dev->data->dev_private;
+       struct mlx5_flow_meters *fms = &priv->flow_meters;
+       struct mlx5_mtr_profiles *fmps = &priv->flow_meter_profiles;
+       struct mlx5_flow_meter_profile *fmp;
+       struct mlx5_flow_meter *fm;
+       const struct rte_flow_attr attr = {
+                               .ingress = 1,
+                               .egress = 1,
+                               .transfer = priv->config.dv_esw_en ? 1 : 0,
+                       };
+       void *tmp;
+       uint32_t i;
+
+       TAILQ_FOREACH_SAFE(fm, fms, next, tmp) {
+               /* Meter object must not have any owner. */
+               RTE_ASSERT(!fm->ref_cnt);
+               /* Get meter profile. */
+               fmp = fm->profile;
+               if (fmp == NULL)
+                       return -rte_mtr_error_set(error, EINVAL,
+                               RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
+                               NULL, "MTR object meter profile invalid.");
+               /* Update dependencies. */
+               fmp->ref_cnt--;
+               /* Remove from list. */
+               TAILQ_REMOVE(fms, fm, next);
+               /* Free policer counters. */
+               for (i = 0; i < RTE_DIM(fm->policer_stats.cnt); i++)
+                       if (fm->policer_stats.cnt[i])
+                               mlx5_counter_free(dev,
+                                                 fm->policer_stats.cnt[i]);
+               /* Free meter flow table. */
+               mlx5_flow_destroy_policer_rules(dev, fm, &attr);
+               mlx5_flow_destroy_mtr_tbls(dev, fm->mfts);
+               rte_free(fm);
+       }
+       TAILQ_FOREACH_SAFE(fmp, fmps, next, tmp) {
+               /* Check unused. */
+               RTE_ASSERT(!fmp->ref_cnt);
+               /* Remove from list. */
+               TAILQ_REMOVE(&priv->flow_meter_profiles, fmp, next);
+               rte_free(fmp);
+       }
+       return 0;
+}