5 ======================
6
7 The i40e PMD (**librte_net_i40e**) provides poll mode driver support for
8 10/25/40 Gbps Intel® Ethernet 700 Series Network Adapters based on
9 the Intel Ethernet Controller X710/XL710/XXV710 and Intel Ethernet
10 Connection X722 (only support part of features).
11
12
13 Features
14 --------
15
16 Features of the i40e PMD are:
17
18 - Multiple queues for TX and RX
19 - Receiver Side Scaling (RSS)
20 - MAC/VLAN filtering
21 - Packet type information
22 - Flow director
23 - Cloud filter
24 - Checksum offload
25 - VLAN/QinQ stripping and inserting
26 - TSO offload
27 - Promiscuous mode
28 - Multicast mode
29 - Port hardware statistics
30 - Jumbo frames
31 - Link state information
32 - Link flow control
33 - Mirror on port, VLAN and VSI
34 - Interrupt mode for RX
35 - Scattered and gather for TX and RX
36 - Vector Poll mode driver
37 - DCB
38 - VMDQ
39 - SR-IOV VF
40 - Hot plug
41 - IEEE1588/802.1AS timestamping
42 - VF Daemon (VFD) - EXPERIMENTAL
43 - Dynamic Device Personalization (DDP)
44 - Queue region configuration
45 - Virtual Function Port Representors
46 - Malicious Device Drive event catch and notify
47 - Generic flow API
48
49 Linux Prerequisites
50 -------------------
51
52 - Identifying your adapter using `Intel Support
53   <http://www.intel.com/support>`_ and get the latest NVM/FW images.
54
55 - Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
56
57 - To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms"
58   section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
59
60 - Upgrade the NVM/FW version following the `Intel® Ethernet NVM Update Tool Quick Usage Guide for Linux
61   <https://www-ssl.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-linux-usage-guide.html>`_ and `Intel® Ethernet NVM Update Tool: Quick Usage Guide for EFI <https://www.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-efi-usage-guide.html>`_ if needed.
62
63 - For information about supported media, please refer to this document: `Intel® Ethernet Controller X710/XXV710/XL710 Feature Support Matrix
64   <http://www.intel.com/content/dam/www/public/us/en/documents/release-notes/xl710-ethernet-controller-feature-matrix.pdf>`_.
65
66    .. Note::
67
68       * Some adapters based on the Intel(R) Ethernet Controller 700 Series only
69         support Intel Ethernet Optics modules. On these adapters, other modules are not
70         supported and will not function.
71
72       * For connections based on Intel(R) Ethernet Controller 700 Series,
73         support is dependent on your system board. Please see your vendor for details.
74
75       * In all cases Intel recommends using Intel Ethernet Optics; other modules
76         may function but are not validated by Intel. Contact Intel for supported media types.
77
78 Windows Prerequisites
79 ---------------------
80
81 - Follow the :doc:`guide for Windows <../windows_gsg/run_apps>`
82   to setup the basic DPDK environment.
83
84 - Identify the Intel® Ethernet adapter and get the latest NVM/FW version.
85
86 - To access any Intel® Ethernet hardware, load the NetUIO driver in place of existing built-in (inbox) driver.
87
88 - To load NetUIO driver, follow the steps mentioned in `dpdk-kmods repository
89   <https://git.dpdk.org/dpdk-kmods/tree/windows/netuio/README.rst>`_.
90
91 Recommended Matching List
92 -------------------------
93
94 It is highly recommended to upgrade the i40e kernel driver and firmware to
95 avoid the compatibility issues with i40e PMD. Here is the suggested matching
96 list which has been tested and verified. The detailed information can refer
97 to chapter Tested Platforms/Tested NICs in release notes.
98
99 For X710/XL710/XXV710,
100
101    +--------------+-----------------------+------------------+
102    | DPDK version | Kernel driver version | Firmware version |
103    +==============+=======================+==================+
104    |    21.02     |         2.14.13       |       8.00       |
105    +--------------+-----------------------+------------------+
106    |    20.11     |         2.14.13       |       8.00       |
107    +--------------+-----------------------+------------------+
108    |    20.08     |         2.12.6        |       7.30       |
109    +--------------+-----------------------+------------------+
110    |    20.05     |         2.11.27       |       7.30       |
111    +--------------+-----------------------+------------------+
112    |    20.02     |         2.10.19       |       7.20       |
113    +--------------+-----------------------+------------------+
114    |    19.11     |         2.9.21        |       7.00       |
115    +--------------+-----------------------+------------------+
116    |    19.08     |         2.8.43        |       7.00       |
117    +--------------+-----------------------+------------------+
118    |    19.05     |         2.7.29        |       6.80       |
119    +--------------+-----------------------+------------------+
120    |    19.02     |         2.7.26        |       6.80       |
121    +--------------+-----------------------+------------------+
122    |    18.11     |         2.4.6         |       6.01       |
123    +--------------+-----------------------+------------------+
124    |    18.08     |         2.4.6         |       6.01       |
125    +--------------+-----------------------+------------------+
126    |    18.05     |         2.4.6         |       6.01       |
127    +--------------+-----------------------+------------------+
128    |    18.02     |         2.4.3         |       6.01       |
129    +--------------+-----------------------+------------------+
130    |    17.11     |         2.1.26        |       6.01       |
131    +--------------+-----------------------+------------------+
132    |    17.08     |         2.0.19        |       6.01       |
133    +--------------+-----------------------+------------------+
134    |    17.05     |         1.5.23        |       5.05       |
135    +--------------+-----------------------+------------------+
136    |    17.02     |         1.5.23        |       5.05       |
137    +--------------+-----------------------+------------------+
138    |    16.11     |         1.5.23        |       5.05       |
139    +--------------+-----------------------+------------------+
140    |    16.07     |         1.4.25        |       5.04       |
141    +--------------+-----------------------+------------------+
142    |    16.04     |         1.4.25        |       5.02       |
143    +--------------+-----------------------+------------------+
144
145
146 For X722,
147
148    +--------------+-----------------------+------------------+
149    | DPDK version | Kernel driver version | Firmware version |
150    +==============+=======================+==================+
151    |    21.02     |         2.14.13       |       5.00       |
152    +--------------+-----------------------+------------------+
153    |    20.11     |         2.13.10       |       5.00       |
154    +--------------+-----------------------+------------------+
155    |    20.08     |         2.12.6        |       4.11       |
156    +--------------+-----------------------+------------------+
157    |    20.05     |         2.11.27       |       4.11       |
158    +--------------+-----------------------+------------------+
159    |    20.02     |         2.10.19       |       4.11       |
160    +--------------+-----------------------+------------------+
161    |    19.11     |         2.9.21        |       4.10       |
162    +--------------+-----------------------+------------------+
163    |    19.08     |         2.9.21        |       4.10       |
164    +--------------+-----------------------+------------------+
165    |    19.05     |         2.7.29        |       3.33       |
166    +--------------+-----------------------+------------------+
167    |    19.02     |         2.7.26        |       3.33       |
168    +--------------+-----------------------+------------------+
169    |    18.11     |         2.4.6         |       3.33       |
170    +--------------+-----------------------+------------------+
171
172
173 Pre-Installation Configuration
174 ------------------------------
175
176 Config File Options
177 ~~~~~~~~~~~~~~~~~~~
178
179 The following options can be modified in the ``config/rte_config.h`` file.
180
181 - ``RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
182
183   Number of queues reserved for PF.
184
185 - ``RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
186
187   Number of queues reserved for each VMDQ Pool.
188
189 Runtime Config Options
190 ~~~~~~~~~~~~~~~~~~~~~~
191
192 - ``Reserved number of Queues per VF`` (default ``4``)
193
194   The number of reserved queue per VF is determined by its host PF. If the
195   PCI address of an i40e PF is aaaa:bb.cc, the number of reserved queues per
196   VF can be configured with EAL parameter like -a aaaa:bb.cc,queue-num-per-vf=n.
197   The value n can be 1, 2, 4, 8 or 16. If no such parameter is configured, the
198   number of reserved queues per VF is 4 by default. If VF request more than
199   reserved queues per VF, PF will able to allocate max to 16 queues after a VF
200   reset.
201
202
203 - ``Support multiple driver`` (default ``disable``)
204
205   There was a multiple driver support issue during use of 700 series Ethernet
206   Adapter with both Linux kernel and DPDK PMD. To fix this issue, ``devargs``
207   parameter ``support-multi-driver`` is introduced, for example::
208
209     -a 84:00.0,support-multi-driver=1
210
211   With the above configuration, DPDK PMD will not change global registers, and
212   will switch PF interrupt from IntN to Int0 to avoid interrupt conflict between
213   DPDK and Linux Kernel.
214
215 - ``Support VF Port Representor`` (default ``not enabled``)
216
217   The i40e PF PMD supports the creation of VF port representors for the control
218   and monitoring of i40e virtual function devices. Each port representor
219   corresponds to a single virtual function of that device. Using the ``devargs``
220   option ``representor`` the user can specify which virtual functions to create
221   port representors for on initialization of the PF PMD by passing the VF IDs of
222   the VFs which are required.::
223
224   -a DBDF,representor=[0,1,4]
225
226   Currently hot-plugging of representor ports is not supported so all required
227   representors must be specified on the creation of the PF.
228
229 - ``Enable validation for VF message`` (default ``not enabled``)
230
231   The PF counts messages from each VF. If in any period of seconds the message
232   statistic from a VF exceeds maximal limitation, the PF will ignore any new message
233   from that VF for some seconds.
234   Format -- "maximal-message@period-seconds:ignore-seconds"
235   For example::
236
237   -a 84:00.0,vf_msg_cfg=80@120:180
238
239 Vector RX Pre-conditions
240 ~~~~~~~~~~~~~~~~~~~~~~~~
241 For Vector RX it is assumed that the number of descriptor rings will be a power
242 of 2. With this pre-condition, the ring pointer can easily scroll back to the
243 head after hitting the tail without a conditional check. In addition Vector RX
244 can use this assumption to do a bit mask using ``ring_size - 1``.
245
246 Driver compilation and testing
247 ------------------------------
248
249 Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
250 for details.
251
252
253 SR-IOV: Prerequisites and sample Application Notes
254 --------------------------------------------------
255
256 #. Load the kernel module:
257
258    .. code-block:: console
259
260       modprobe i40e
261
262    Check the output in dmesg:
263
264    .. code-block:: console
265
266       i40e 0000:83:00.1 ens802f0: renamed from eth0
267
268 #. Bring up the PF ports:
269
270    .. code-block:: console
271
272       ifconfig ens802f0 up
273
274 #. Create VF device(s):
275
276    Echo the number of VFs to be created into the ``sriov_numvfs`` sysfs entry
277    of the parent PF.
278
279    Example:
280
281    .. code-block:: console
282
283       echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
284
285
286 #. Assign VF MAC address:
287
288    Assign MAC address to the VF using iproute2 utility. The syntax is:
289
290    .. code-block:: console
291
292       ip link set <PF netdev id> vf <VF id> mac <macaddr>
293
294    Example:
295
296    .. code-block:: console
297
298       ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0
299
300 #. Assign VF to VM, and bring up the VM.
301    Please see the documentation for the *I40E/IXGBE/IGB Virtual Function Driver*.
302
303 #. Running testpmd:
304
305    Follow instructions available in the document
306    :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
307    to run testpmd.
308
309    Example output:
310
311    .. code-block:: console
312
313       ...
314       EAL: PCI device 0000:83:00.0 on NUMA socket 1
315       EAL: probe driver: 8086:1572 rte_i40e_pmd
316       EAL: PCI memory mapped at 0x7f7f80000000
317       EAL: PCI memory mapped at 0x7f7f80800000
318       PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a
319       Interactive-mode selected
320       Configuring Port 0 (socket 0)
321       ...
322
323       PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are
324       satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0.
325
326       ...
327       Port 0: 68:05:CA:26:85:84
328       Checking link statuses...
329       Port 0 Link Up - speed 10000 Mbps - full-duplex
330       Done
331
332       testpmd>
333
334
335 Sample Application Notes
336 ------------------------
337
338 Vlan filter
339 ~~~~~~~~~~~
340
341 Vlan filter only works when Promiscuous mode is off.
342
343 To start ``testpmd``, and add vlan 10 to port 0:
344
345 .. code-block:: console
346
347     ./<build_dir>/app/dpdk-testpmd -l 0-15 -n 4 -- -i --forward-mode=mac
348     ...
349
350     testpmd> set promisc 0 off
351     testpmd> rx_vlan add 10 0
352
353
354 Flow Director
355 ~~~~~~~~~~~~~
356
357 The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
358 The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload.
359
360 The default input set of each flow type is::
361
362    ipv4-other : src_ip_address, dst_ip_address
363    ipv4-frag  : src_ip_address, dst_ip_address
364    ipv4-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
365    ipv4-udp   : src_ip_address, dst_ip_address, src_port, dst_port
366    ipv4-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
367                 verification_tag
368    ipv6-other : src_ip_address, dst_ip_address
369    ipv6-frag  : src_ip_address, dst_ip_address
370    ipv6-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
371    ipv6-udp   : src_ip_address, dst_ip_address, src_port, dst_port
372    ipv6-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
373                 verification_tag
374    l2_payload : ether_type
375
376 The flex payload is selected from offset 0 to 15 of packet's payload by default, while it is masked out from matching.
377
378 Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``:
379
380 .. code-block:: console
381
382    ./<build_dir>/app/dpdk-testpmd -l 0-15 -n 4 -- -i --disable-rss \
383                  --pkt-filter-mode=perfect --rxq=8 --txq=8 --nb-cores=8 \
384                  --nb-ports=1
385
386 Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1:
387
388 .. code-block:: console
389
390    testpmd> flow create 0 ingress pattern eth / ipv4 src is 2.2.2.3 \
391             dst is 2.2.2.5 / udp src is 32 dst is 32 / end \
392             actions mark id 1 / queue index 1 / end
393
394 Check the flow director status:
395
396 .. code-block:: console
397
398    testpmd> show port fdir 0
399
400    ######################## FDIR infos for port 0      ####################
401      MODE:   PERFECT
402      SUPPORTED FLOW TYPE:  ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other
403                            ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other
404                            l2_payload
405      FLEX PAYLOAD INFO:
406      max_len:       16          payload_limit: 480
407      payload_unit:  2           payload_seg:   3
408      bitmask_unit:  2           bitmask_num:   2
409      MASK:
410        vlan_tci: 0x0000,
411        src_ipv4: 0x00000000,
412        dst_ipv4: 0x00000000,
413        src_port: 0x0000,
414        dst_port: 0x0000
415        src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000,
416        dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000
417      FLEX PAYLOAD SRC OFFSET:
418        L2_PAYLOAD:    0      1      2      3      4      5      6  ...
419        L3_PAYLOAD:    0      1      2      3      4      5      6  ...
420        L4_PAYLOAD:    0      1      2      3      4      5      6  ...
421      FLEX MASK CFG:
422        ipv4-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
423        ipv4-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
424        ipv4-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
425        ipv4-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
426        ipv4-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
427        ipv6-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
428        ipv6-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
429        ipv6-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
430        ipv6-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
431        ipv6-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
432        l2_payload:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
433      guarant_count: 1           best_count:    0
434      guarant_space: 512         best_space:    7168
435      collision:     0           free:          0
436      maxhash:       0           maxlen:        0
437      add:           0           remove:        0
438      f_add:         0           f_remove:      0
439
440
441 Floating VEB
442 ~~~~~~~~~~~~~
443
444 The Intel® Ethernet 700 Series support a feature called
445 "Floating VEB".
446
447 A Virtual Ethernet Bridge (VEB) is an IEEE Edge Virtual Bridging (EVB) term
448 for functionality that allows local switching between virtual endpoints within
449 a physical endpoint and also with an external bridge/network.
450
451 A "Floating" VEB doesn't have an uplink connection to the outside world so all
452 switching is done internally and remains within the host. As such, this
453 feature provides security benefits.
454
455 In addition, a Floating VEB overcomes a limitation of normal VEBs where they
456 cannot forward packets when the physical link is down. Floating VEBs don't need
457 to connect to the NIC port so they can still forward traffic from VF to VF
458 even when the physical link is down.
459
460 Therefore, with this feature enabled VFs can be limited to communicating with
461 each other but not an outside network, and they can do so even when there is
462 no physical uplink on the associated NIC port.
463
464 To enable this feature, the user should pass a ``devargs`` parameter to the
465 EAL, for example::
466
467     -a 84:00.0,enable_floating_veb=1
468
469 In this configuration the PMD will use the floating VEB feature for all the
470 VFs created by this PF device.
471
472 Alternatively, the user can specify which VFs need to connect to this floating
473 VEB using the ``floating_veb_list`` argument::
474
475     -a 84:00.0,enable_floating_veb=1,floating_veb_list=1;3-4
476
477 In this example ``VF1``, ``VF3`` and ``VF4`` connect to the floating VEB,
478 while other VFs connect to the normal VEB.
479
480 The current implementation only supports one floating VEB and one regular
481 VEB. VFs can connect to a floating VEB or a regular VEB according to the
482 configuration passed on the EAL command line.
483
484 The floating VEB functionality requires a NIC firmware version of 5.0
485 or greater.
486
487 Dynamic Device Personalization (DDP)
488 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
489
490 The Intel® Ethernet 700 Series except for the Intel Ethernet Connection
491 X722 support a feature called "Dynamic Device Personalization (DDP)",
492 which is used to configure hardware by downloading a profile to support
493 protocols/filters which are not supported by default. The DDP
494 functionality requires a NIC firmware version of 6.0 or greater.
495
496 Current implementation supports GTP-C/GTP-U/PPPoE/PPPoL2TP/ESP,
497 steering can be used with rte_flow API.
498
499 GTPv1 package is released, and it can be downloaded from
500 https://downloadcenter.intel.com/download/27587.
501
502 PPPoE package is released, and it can be downloaded from
503 https://downloadcenter.intel.com/download/28040.
504
505 ESP-AH package is released, and it can be downloaded from
506 https://downloadcenter.intel.com/download/29446.
507
508 Load a profile which supports GTP and store backup profile:
509
510 .. code-block:: console
511
512    testpmd> ddp add 0 ./gtp.pkgo,./backup.pkgo
513
514 Delete a GTP profile and restore backup profile:
515
516 .. code-block:: console
517
518    testpmd> ddp del 0 ./backup.pkgo
519
520 Get loaded DDP package info list:
521
522 .. code-block:: console
523
524    testpmd> ddp get list 0
525
526 Display information about a GTP profile:
527
528 .. code-block:: console
529
530    testpmd> ddp get info ./gtp.pkgo
531
532 Input set configuration
533 ~~~~~~~~~~~~~~~~~~~~~~~
534 Input set for any PCTYPE can be configured with user defined configuration,
535 For example, to use only 48bit prefix for IPv6 src address for IPv6 TCP RSS:
536
537 .. code-block:: console
538
539    testpmd> port config 0 pctype 43 hash_inset clear all
540    testpmd> port config 0 pctype 43 hash_inset set field 13
541    testpmd> port config 0 pctype 43 hash_inset set field 14
542    testpmd> port config 0 pctype 43 hash_inset set field 15
543
544 Queue region configuration
545 ~~~~~~~~~~~~~~~~~~~~~~~~~~~
546 The Intel® Ethernet 700 Series supports a feature of queue regions
547 configuration for RSS in the PF, so that different traffic classes or
548 different packet classification types can be separated to different
549 queues in different queue regions. There is an API for configuration
550 of queue regions in RSS with a command line. It can parse the parameters
551 of the region index, queue number, queue start index, user priority, traffic
552 classes and so on. Depending on commands from the command line, it will call
553 i40e private APIs and start the process of setting or flushing the queue
554 region configuration. As this feature is specific for i40e only private
555 APIs are used. These new ``test_pmd`` commands are as shown below. For
556 details please refer to :doc:`../testpmd_app_ug/index`.
557
558 .. code-block:: console
559
560    testpmd> set port (port_id) queue-region region_id (value) \
561                 queue_start_index (value) queue_num (value)
562    testpmd> set port (port_id) queue-region region_id (value) flowtype (value)
563    testpmd> set port (port_id) queue-region UP (value) region_id (value)
564    testpmd> set port (port_id) queue-region flush (on|off)
565    testpmd> show port (port_id) queue-region
566
567 Generic flow API
568 ~~~~~~~~~~~~~~~~~~~
569
570 - ``RSS Flow``
571
572   RSS Flow supports to set hash input set, hash function, enable hash
573   and configure queues.
574   For example:
575   Configure queues as queue 0, 1, 2, 3.
576
577   .. code-block:: console
578
579     testpmd> flow create 0 ingress pattern end actions rss types end \
580       queues 0 1 2 3 end / end
581
582   Enable hash and set input set for ipv4-tcp.
583
584   .. code-block:: console
585
586     testpmd> flow create 0 ingress pattern eth / ipv4 / tcp / end \
587       actions rss types ipv4-tcp l3-src-only end queues end / end
588
589   Set symmetric hash enable for flow type ipv4-tcp.
590
591   .. code-block:: console
592
593     testpmd> flow create 0 ingress pattern eth / ipv4 / tcp / end \
594       actions rss types ipv4-tcp end queues end func symmetric_toeplitz / end
595
596   Set hash function as simple xor.
597
598   .. code-block:: console
599
600     testpmd> flow create 0 ingress pattern end actions rss types end \
601       queues end func simple_xor / end
602
603 Limitations or Known issues
604 ---------------------------
605
606 MPLS packet classification
607 ~~~~~~~~~~~~~~~~~~~~~~~~~~
608
609 For firmware versions prior to 5.0, MPLS packets are not recognized by the NIC.
610 The L2 Payload flow type in flow director can be used to classify MPLS packet
611 by using a command in testpmd like:
612
613    testpmd> flow_director_filter 0 mode IP add flow l2_payload ether \
614             0x8847 flexbytes () fwd pf queue <N> fd_id <M>
615
616 With the NIC firmware version 5.0 or greater, some limited MPLS support
617 is added: Native MPLS (MPLS in Ethernet) skip is implemented, while no
618 new packet type, no classification or offload are possible. With this change,
619 L2 Payload flow type in flow director cannot be used to classify MPLS packet
620 as with previous firmware versions. Meanwhile, the Ethertype filter can be
621 used to classify MPLS packet by using a command in testpmd like:
622
623    testpmd> flow create 0 ingress pattern eth type is 0x8847 / end \
624             actions queue index <M> / end
625
626 16 Byte RX Descriptor setting on DPDK VF
627 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
628
629 Currently the VF's RX descriptor mode is decided by PF. There's no PF-VF
630 interface for VF to request the RX descriptor mode, also no interface to notify
631 VF its own RX descriptor mode.
632 For all available versions of the i40e driver, these drivers don't support 16
633 byte RX descriptor. If the Linux i40e kernel driver is used as host driver,
634 while DPDK i40e PMD is used as the VF driver, DPDK cannot choose 16 byte receive
635 descriptor. The reason is that the RX descriptor is already set to 32 byte by
636 the i40e kernel driver.
637 In the future, if the Linux i40e driver supports 16 byte RX descriptor, user
638 should make sure the DPDK VF uses the same RX descriptor mode, 16 byte or 32
639 byte, as the PF driver.
640
641 The same rule for DPDK PF + DPDK VF. The PF and VF should use the same RX
642 descriptor mode. Or the VF RX will not work.
643
644 Receive packets with Ethertype 0x88A8
645 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
646
647 Due to the FW limitation, PF can receive packets with Ethertype 0x88A8
648 only when floating VEB is disabled.
649
650 Incorrect Rx statistics when packet is oversize
651 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
652
653 When a packet is over maximum frame size, the packet is dropped.
654 However, the Rx statistics, when calling `rte_eth_stats_get` incorrectly
655 shows it as received.
656
657 RX/TX statistics may be incorrect when register overflowed
658 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
659
660 The rx_bytes/tx_bytes statistics register is 48 bit length.
661 Although this limitation is enlarged to 64 bit length on the software side,
662 but there is no way to detect if the overflow occurred more than once.
663 So rx_bytes/tx_bytes statistics data is correct when statistics are
664 updated at least once between two overflows.
665
666 VF & TC max bandwidth setting
667 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
668
669 The per VF max bandwidth and per TC max bandwidth cannot be enabled in parallel.
670 The behavior is different when handling per VF and per TC max bandwidth setting.
671 When enabling per VF max bandwidth, SW will check if per TC max bandwidth is
672 enabled. If so, return failure.
673 When enabling per TC max bandwidth, SW will check if per VF max bandwidth
674 is enabled. If so, disable per VF max bandwidth and continue with per TC max
675 bandwidth setting.
676
677 TC TX scheduling mode setting
678 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
679
680 There are 2 TX scheduling modes for TCs, round robin and strict priority mode.
681 If a TC is set to strict priority mode, it can consume unlimited bandwidth.
682 It means if APP has set the max bandwidth for that TC, it comes to no
683 effect.
684 It's suggested to set the strict priority mode for a TC that is latency
685 sensitive but no consuming much bandwidth.
686
687 VF performance is impacted by PCI extended tag setting
688 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
689
690 To reach maximum NIC performance in the VF the PCI extended tag must be
691 enabled. The DPDK i40e PF driver will set this feature during initialization,
692 but the kernel PF driver does not. So when running traffic on a VF which is
693 managed by the kernel PF driver, a significant NIC performance downgrade has
694 been observed (for 64 byte packets, there is about 25% line-rate downgrade for
695 a 25GbE device and about 35% for a 40GbE device).
696
697 For kernel version >= 4.11, the kernel's PCI driver will enable the extended
698 tag if it detects that the device supports it. So by default, this is not an
699 issue. For kernels <= 4.11 or when the PCI extended tag is disabled it can be
700 enabled using the steps below.
701
702 #. Get the current value of the PCI configure register::
703
704       setpci -s <XX:XX.X> a8.w
705
706 #. Set bit 8::
707
708       value = value | 0x100
709
710 #. Set the PCI configure register with new value::
711
712       setpci -s <XX:XX.X> a8.w=<value>
713
714 Vlan strip of VF
715 ~~~~~~~~~~~~~~~~
716
717 The VF vlan strip function is only supported in the i40e kernel driver >= 2.1.26.
718
719 DCB function
720 ~~~~~~~~~~~~
721
722 DCB works only when RSS is enabled.
723
724 Global configuration warning
725 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
726
727 I40E PMD will set some global registers to enable some function or set some
728 configure. Then when using different ports of the same NIC with Linux kernel
729 and DPDK, the port with Linux kernel will be impacted by the port with DPDK.
730 For example, register I40E_GL_SWT_L2TAGCTRL is used to control L2 tag, i40e
731 PMD uses I40E_GL_SWT_L2TAGCTRL to set vlan TPID. If setting TPID in port A
732 with DPDK, then the configuration will also impact port B in the NIC with
733 kernel driver, which don't want to use the TPID.
734 So PMD reports warning to clarify what is changed by writing global register.
735
736 Cloud Filter
737 ~~~~~~~~~~~~
738
739 When programming cloud filters for IPv4/6_UDP/TCP/SCTP with SRC port only or DST port only,
740 it will make any cloud filter using inner_vlan or tunnel key invalid. Default configuration will be
741 recovered only by NIC core reset.
742
743 Mirror rule limitation for X722
744 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
745
746 Due to firmware restriction of X722, the same VSI cannot have more than one mirror rule.
747
748 High Performance of Small Packets on 40GbE NIC
749 ----------------------------------------------
750
751 As there might be firmware fixes for performance enhancement in latest version
752 of firmware image, the firmware update might be needed for getting high performance.
753 Check the Intel support website for the latest firmware updates.
754 Users should consult the release notes specific to a DPDK release to identify
755 the validated firmware version for a NIC using the i40e driver.
756
757 Use 16 Bytes RX Descriptor Size
758 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
759
760 As i40e PMD supports both 16 and 32 bytes RX descriptor sizes, and 16 bytes size can provide helps to high performance of small packets.
761 In ``config/rte_config.h`` set the following to use 16 bytes size RX descriptors::
762
763    #define RTE_LIBRTE_I40E_16BYTE_RX_DESC 1
764
765 Input set requirement of each pctype for FDIR
766 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
767
768 Each PCTYPE can only have one specific FDIR input set at one time.
769 For example, if creating 2 rte_flow rules with different input set for one PCTYPE,
770 it will fail and return the info "Conflict with the first rule's input set",
771 which means the current rule's input set conflicts with the first rule's.
772 Remove the first rule if want to change the input set of the PCTYPE.
773
774 Example of getting best performance with l3fwd example
775 ------------------------------------------------------
776
777 The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with a
778 server with Intel Xeon processors and Intel Ethernet CNA XL710.
779
780 The example scenario is to get best performance with two Intel Ethernet CNA XL710 40GbE ports.
781 See :numref:`figure_intel_perf_test_setup` for the performance test setup.
782
783 .. _figure_intel_perf_test_setup:
784
785 .. figure:: img/intel_perf_test_setup.*
786
787    Performance Test Setup
788
789
790 1. Add two Intel Ethernet CNA XL710 to the platform, and use one port per card to get best performance.
791    The reason for using two NICs is to overcome a PCIe v3.0 limitation since it cannot provide 80GbE bandwidth
792    for two 40GbE ports, but two different PCIe v3.0 x8 slot can.
793    Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
794
795       82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
796       85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
797
798 2. Connect the ports to the traffic generator. For high speed testing, it's best to use a hardware traffic generator.
799
800 3. Check the PCI devices numa node (socket id) and get the cores number on the exact socket id.
801    In this case, ``82:00.0`` and ``85:00.0`` are both in socket 1, and the cores on socket 1 in the referenced platform
802    are 18-35 and 54-71.
803    Note: Don't use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical
804    cores from different cores (e.g core18 and core19).
805
806 4. Bind these two ports to igb_uio.
807
808 5. As to Intel Ethernet CNA XL710 40GbE port, we need at least two queue pairs to achieve best performance, then two queues per port
809    will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
810
811 6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
812    Compile the ``l3fwd sample`` with the default lpm mode.
813
814 7. The command line of running l3fwd would be something like the following::
815
816       ./dpdk-l3fwd -l 18-21 -n 4 -a 82:00.0 -a 85:00.0 \
817               -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
818
819    This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
820    core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
821
822 8. Configure the traffic at a traffic generator.
823
824    * Start creating a stream on packet generator.
825
826    * Set the Ethernet II type to 0x0800.
827
828 Tx bytes affected by the link status change
829 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
830
831 For firmware versions prior to 6.01 for X710 series and 3.33 for X722 series, the tx_bytes statistics data is affected by
832 the link down event. Each time the link status changes to down, the tx_bytes decreases 110 bytes.