doc: fix diagram in dpaa2 guide
[dpdk.git] / doc / guides / nics / ice.rst
1 ..  SPDX-License-Identifier: BSD-3-Clause
2     Copyright(c) 2018 Intel Corporation.
3
4 ICE Poll Mode Driver
5 ======================
6
7 The ice PMD (librte_pmd_ice) provides poll mode driver support for
8 10/25/50/100 Gbps IntelĀ® Ethernet 810 Series Network Adapters based on
9 the Intel Ethernet Controller E810.
10
11
12 Prerequisites
13 -------------
14
15 - Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
16
17 - To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms"
18   section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
19
20 Pre-Installation Configuration
21 ------------------------------
22
23 Config File Options
24 ~~~~~~~~~~~~~~~~~~~
25
26 The following options can be modified in the ``config`` file.
27 Please note that enabling debugging options may affect system performance.
28
29 - ``CONFIG_RTE_LIBRTE_ICE_PMD`` (default ``y``)
30
31   Toggle compilation of the ``librte_pmd_ice`` driver.
32
33 - ``CONFIG_RTE_LIBRTE_ICE_DEBUG_*`` (default ``n``)
34
35   Toggle display of generic debugging messages.
36
37 - ``CONFIG_RTE_LIBRTE_ICE_16BYTE_RX_DESC`` (default ``n``)
38
39   Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte.
40
41 Runtime Config Options
42 ~~~~~~~~~~~~~~~~~~~~~~
43
44 - ``Safe Mode Support`` (default ``0``)
45
46   If driver failed to load OS package, by default driver's initialization failed.
47   But if user intend to use the device without OS package, user can take ``devargs``
48   parameter ``safe-mode-support``, for example::
49
50     -w 80:00.0,safe-mode-support=1
51
52   Then the driver will be initialized successfully and the device will enter Safe Mode.
53   NOTE: In Safe mode, only very limited features are available, features like RSS,
54   checksum, fdir, tunneling ... are all disabled.
55
56 - ``Generic Flow Pipeline Mode Support`` (default ``0``)
57
58   In pipeline mode, a flow can be set at one specific stage by setting parameter
59   ``priority``. Currently, we support two stages: priority = 0 or !0. Flows with
60   priority 0 located at the first pipeline stage which typically be used as a firewall
61   to drop the packet on a blacklist(we called it permission stage). At this stage,
62   flow rules are created for the device's exact match engine: switch. Flows with priority
63   !0 located at the second stage, typically packets are classified here and be steered to
64   specific queue or queue group (we called it distribution stage), At this stage, flow
65   rules are created for device's flow director engine.
66   For none-pipeline mode, ``priority`` is ignored, a flow rule can be created as a flow director
67   rule or a switch rule depends on its pattern/action and the resource allocation situation,
68   all flows are virtually at the same pipeline stage.
69   By default, generic flow API is enabled in none-pipeline mode, user can choose to
70   use pipeline mode by setting ``devargs`` parameter ``pipeline-mode-support``,
71   for example::
72
73     -w 80:00.0,pipeline-mode-support=1
74
75 - ``Protocol extraction for per queue``
76
77   Configure the RX queues to do protocol extraction into mbuf for protocol
78   handling acceleration, like checking the TCP SYN packets quickly.
79
80   The argument format is::
81
82       -w 18:00.0,proto_xtr=<queues:protocol>[<queues:protocol>...]
83       -w 18:00.0,proto_xtr=<protocol>
84
85   Queues are grouped by ``(`` and ``)`` within the group. The ``-`` character
86   is used as a range separator and ``,`` is used as a single number separator.
87   The grouping ``()`` can be omitted for single element group. If no queues are
88   specified, PMD will use this protocol extraction type for all queues.
89
90   Protocol is : ``vlan, ipv4, ipv6, ipv6_flow, tcp, ip_offset``.
91
92   .. code-block:: console
93
94     testpmd -w 18:00.0,proto_xtr='[(1,2-3,8-9):tcp,10-13:vlan]'
95
96   This setting means queues 1, 2-3, 8-9 are TCP extraction, queues 10-13 are
97   VLAN extraction, other queues run with no protocol extraction.
98
99   .. code-block:: console
100
101     testpmd -w 18:00.0,proto_xtr=vlan,proto_xtr='[(1,2-3,8-9):tcp,10-23:ipv6]'
102
103   This setting means queues 1, 2-3, 8-9 are TCP extraction, queues 10-23 are
104   IPv6 extraction, other queues use the default VLAN extraction.
105
106   The extraction metadata is copied into the registered dynamic mbuf field, and
107   the related dynamic mbuf flags is set.
108
109   .. table:: Protocol extraction : ``vlan``
110
111    +----------------------------+----------------------------+
112    |           VLAN2            |           VLAN1            |
113    +======+===+=================+======+===+=================+
114    |  PCP | D |       VID       |  PCP | D |       VID       |
115    +------+---+-----------------+------+---+-----------------+
116
117   VLAN1 - single or EVLAN (first for QinQ).
118
119   VLAN2 - C-VLAN (second for QinQ).
120
121   .. table:: Protocol extraction : ``ipv4``
122
123    +----------------------------+----------------------------+
124    |           IPHDR2           |           IPHDR1           |
125    +======+=======+=============+==============+=============+
126    |  Ver |Hdr Len|    ToS      |      TTL     |  Protocol   |
127    +------+-------+-------------+--------------+-------------+
128
129   IPHDR1 - IPv4 header word 4, "TTL" and "Protocol" fields.
130
131   IPHDR2 - IPv4 header word 0, "Ver", "Hdr Len" and "Type of Service" fields.
132
133   .. table:: Protocol extraction : ``ipv6``
134
135    +----------------------------+----------------------------+
136    |           IPHDR2           |           IPHDR1           |
137    +=====+=============+========+=============+==============+
138    | Ver |Traffic class|  Flow  | Next Header |   Hop Limit  |
139    +-----+-------------+--------+-------------+--------------+
140
141   IPHDR1 - IPv6 header word 3, "Next Header" and "Hop Limit" fields.
142
143   IPHDR2 - IPv6 header word 0, "Ver", "Traffic class" and high 4 bits of
144   "Flow Label" fields.
145
146   .. table:: Protocol extraction : ``ipv6_flow``
147
148    +----------------------------+----------------------------+
149    |           IPHDR2           |           IPHDR1           |
150    +=====+=============+========+============================+
151    | Ver |Traffic class|            Flow Label               |
152    +-----+-------------+-------------------------------------+
153
154   IPHDR1 - IPv6 header word 1, 16 low bits of the "Flow Label" field.
155
156   IPHDR2 - IPv6 header word 0, "Ver", "Traffic class" and high 4 bits of
157   "Flow Label" fields.
158
159   .. table:: Protocol extraction : ``tcp``
160
161    +----------------------------+----------------------------+
162    |           TCPHDR2          |           TCPHDR1          |
163    +============================+======+======+==============+
164    |          Reserved          |Offset|  RSV |     Flags    |
165    +----------------------------+------+------+--------------+
166
167   TCPHDR1 - TCP header word 6, "Data Offset" and "Flags" fields.
168
169   TCPHDR2 - Reserved
170
171   .. table:: Protocol extraction : ``ip_offset``
172
173    +----------------------------+----------------------------+
174    |           IPHDR2           |           IPHDR1           |
175    +============================+============================+
176    |       IPv6 HDR Offset      |       IPv4 HDR Offset      |
177    +----------------------------+----------------------------+
178
179   IPHDR1 - Outer/Single IPv4 Header offset.
180
181   IPHDR2 - Outer/Single IPv6 Header offset.
182
183   Use ``rte_net_ice_dynf_proto_xtr_metadata_get`` to access the protocol
184   extraction metadata, and use ``RTE_PKT_RX_DYNF_PROTO_XTR_*`` to get the
185   metadata type of ``struct rte_mbuf::ol_flags``.
186
187   The ``rte_net_ice_dump_proto_xtr_metadata`` routine shows how to
188   access the protocol extraction result in ``struct rte_mbuf``.
189
190 Driver compilation and testing
191 ------------------------------
192
193 Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
194 for details.
195
196 Features
197 --------
198
199 Vector PMD
200 ~~~~~~~~~~
201
202 Vector PMD for RX and TX path are selected automatically. The paths
203 are chosen based on 2 conditions.
204
205 - ``CPU``
206   On the X86 platform, the driver checks if the CPU supports AVX2.
207   If it's supported, AVX2 paths will be chosen. If not, SSE is chosen.
208
209 - ``Offload features``
210   The supported HW offload features are described in the document ice_vec.ini.
211   If any not supported features are used, ICE vector PMD is disabled and the
212   normal paths are chosen.
213
214 Malicious driver detection (MDD)
215 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
216
217 It's not appropriate to send a packet, if this packet's destination MAC address
218 is just this port's MAC address. If SW tries to send such packets, HW will
219 report a MDD event and drop the packets.
220
221 The APPs based on DPDK should avoid providing such packets.
222
223 Device Config Function (DCF)
224 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
225
226 This section demonstrates ICE DCF PMD, which shares the core module with ICE
227 PMD and iAVF PMD.
228
229 A DCF (Device Config Function) PMD bounds to the device's trusted VF with ID 0,
230 it can act as a sole controlling entity to exercise advance functionality (such
231 as switch, ACL) for the rest VFs.
232
233 The DCF PMD needs to advertise and acquire DCF capability which allows DCF to
234 send AdminQ commands that it would like to execute over to the PF and receive
235 responses for the same from PF.
236
237 .. _figure_ice_dcf:
238
239 .. figure:: img/ice_dcf.*
240
241    DCF Communication flow.
242
243 #. Create the VFs::
244
245       echo 4 > /sys/bus/pci/devices/0000\:18\:00.0/sriov_numvfs
246
247 #. Enable the VF0 trust on::
248
249       ip link set dev enp24s0f0 vf 0 trust on
250
251 #. Bind the VF0,  and run testpmd with 'cap=dcf' devarg::
252
253       testpmd -l 22-25 -n 4 -w 18:01.0,cap=dcf -- -i
254
255 #. Monitor the VF2 interface network traffic::
256
257       tcpdump -e -nn -i enp24s1f2
258
259 #. Create one flow to redirect the traffic to VF2 by DCF::
260
261       flow create 0 priority 0 ingress pattern eth / ipv4 src is 192.168.0.2 \
262       dst is 192.168.0.3 / end actions vf id 2 / end
263
264 #. Send the packet, and it should be displayed on tcpdump::
265
266       sendp(Ether(src='3c:fd:fe:aa:bb:78', dst='00:00:00:01:02:03')/IP(src=' \
267       192.168.0.2', dst="192.168.0.3")/TCP(flags='S')/Raw(load='XXXXXXXXXX'), \
268       iface="enp24s0f0", count=10)
269
270 Sample Application Notes
271 ------------------------
272
273 Vlan filter
274 ~~~~~~~~~~~
275
276 Vlan filter only works when Promiscuous mode is off.
277
278 To start ``testpmd``, and add vlan 10 to port 0:
279
280 .. code-block:: console
281
282     ./app/testpmd -l 0-15 -n 4 -- -i
283     ...
284
285     testpmd> rx_vlan add 10 0
286
287 Limitations or Known issues
288 ---------------------------
289
290 The Intel E810 requires a programmable pipeline package be downloaded
291 by the driver to support normal operations. The E810 has a limited
292 functionality built in to allow PXE boot and other use cases, but the
293 driver must download a package file during the driver initialization
294 stage.
295
296 The default DDP package file name is ice.pkg. For a specific NIC, the
297 DDP package supposed to be loaded can have a filename: ice-xxxxxx.pkg,
298 where 'xxxxxx' is the 64-bit PCIe Device Serial Number of the NIC. For
299 example, if the NIC's device serial number is 00-CC-BB-FF-FF-AA-05-68,
300 the device-specific DDP package filename is ice-00ccbbffffaa0568.pkg
301 (in hex and all low case). During initialization, the driver searches
302 in the following paths in order: /lib/firmware/updates/intel/ice/ddp
303 and /lib/firmware/intel/ice/ddp. The corresponding device-specific DDP
304 package will be downloaded first if the file exists. If not, then the
305 driver tries to load the default package. The type of loaded package
306 is stored in ``ice_adapter->active_pkg_type``.
307
308 A symbolic link to the DDP package file is also ok. The same package
309 file is used by both the kernel driver and the DPDK PMD.