doc: remove reference to make from tools guide
[dpdk.git] / doc / guides / nics / sfc_efx.rst
1 ..  SPDX-License-Identifier: BSD-3-Clause
2     Copyright(c) 2019-2020 Xilinx, Inc.
3     Copyright(c) 2016-2019 Solarflare Communications Inc.
4
5     This software was jointly developed between OKTET Labs (under contract
6     for Solarflare) and Solarflare Communications, Inc.
7
8 Solarflare libefx-based Poll Mode Driver
9 ========================================
10
11 The SFC EFX PMD (**librte_pmd_sfc_efx**) provides poll mode driver support
12 for **Solarflare SFN7xxx and SFN8xxx** family of 10/40 Gbps adapters,
13 **Solarflare XtremeScale X2xxx** family of 10/25/40/50/100 Gbps adapters and
14 **Alveo SN1000 SmartNICs** family of 10/25/40/50/100 Gbps adapters.
15 SFC EFX PMD has support for the latest Linux and FreeBSD operating systems.
16
17 More information can be found at `Solarflare Communications website
18 <http://solarflare.com>`_.
19
20
21 Features
22 --------
23
24 SFC EFX PMD has support for:
25
26 - Multiple transmit and receive queues
27
28 - Link state information including link status change interrupt
29
30 - IPv4/IPv6 TCP/UDP transmit checksum offload
31
32 - Inner IPv4/IPv6 TCP/UDP transmit checksum offload
33
34 - Port hardware statistics
35
36 - Extended statistics (see Solarflare Server Adapter User's Guide for
37   the statistics description)
38
39 - Basic flow control
40
41 - MTU update
42
43 - Jumbo frames up to 9K
44
45 - Promiscuous mode
46
47 - Allmulticast mode
48
49 - TCP segmentation offload (TSO) including VXLAN and GENEVE encapsulated
50
51 - Multicast MAC filter
52
53 - IPv4/IPv6 TCP/UDP receive checksum offload
54
55 - Inner IPv4/IPv6 TCP/UDP receive checksum offload
56
57 - Received packet type information
58
59 - Receive side scaling (RSS)
60
61 - RSS hash
62
63 - Scattered Rx DMA for packet that are larger that a single Rx descriptor
64
65 - Receive queue interrupts
66
67 - Deferred receive and transmit queue start
68
69 - Transmit VLAN insertion (if running firmware variant supports it)
70
71 - Flow API
72
73 - Loopback
74
75 - SR-IOV PF
76
77
78 Non-supported Features
79 ----------------------
80
81 The features not yet supported include:
82
83 - Priority-based flow control
84
85 - Configurable RX CRC stripping (always stripped)
86
87 - Header split on receive
88
89 - VLAN filtering
90
91 - VLAN stripping
92
93 - LRO
94
95
96 Limitations
97 -----------
98
99 Due to requirements on receive buffer alignment and usage of the receive
100 buffer for the auxiliary packet information provided by the NIC up to
101 extra 269 (14 bytes prefix plus up to 255 bytes for end padding) bytes may be
102 required in the receive buffer.
103 It should be taken into account when mbuf pool for receive is created.
104
105
106 Equal stride super-buffer mode
107 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
108
109 When the receive queue uses equal stride super-buffer DMA mode, one HW Rx
110 descriptor carries many Rx buffers which contiguously follow each other
111 with some stride (equal to total size of rte_mbuf as mempool object).
112 Each Rx buffer is an independent rte_mbuf.
113 However dedicated mempool manager must be used when mempool for the Rx
114 queue is created. The manager must support dequeue of the contiguous
115 block of objects and provide mempool info API to get the block size.
116
117 Another limitation of a equal stride super-buffer mode, imposed by the
118 firmware, is that it allows for a single RSS context.
119
120
121 Tunnels support
122 ---------------
123
124 NVGRE, VXLAN and GENEVE tunnels are supported on SFN8xxx and X2xxx family
125 adapters with full-feature firmware variant running.
126 **sfboot** should be used to configure NIC to run full-feature firmware variant.
127 See Solarflare Server Adapter User's Guide for details.
128
129 SFN8xxx and X2xxx family adapters provide either inner or outer packet classes.
130 If adapter firmware advertises support for tunnels then the PMD
131 configures the hardware to report inner classes, and outer classes are
132 not reported in received packets.
133 However, for VXLAN and GENEVE tunnels the PMD does report UDP as the
134 outer layer 4 packet type.
135
136 SFN8xxx and X2xxx family adapters report GENEVE packets as VXLAN.
137 If UDP ports are configured for only one tunnel type then it is safe to
138 treat VXLAN packet type indication as the corresponding UDP tunnel type.
139
140
141 Flow API support
142 ----------------
143
144 Supported attributes:
145
146 - Ingress
147
148 Supported pattern items:
149
150 - VOID
151
152 - ETH (exact match of source/destination addresses, individual/group match
153   of destination address, EtherType in the outer frame and exact match of
154   destination addresses, individual/group match of destination address in
155   the inner frame)
156
157 - VLAN (exact match of VID, double-tagging is supported)
158
159 - IPV4 (exact match of source/destination addresses,
160   IP transport protocol)
161
162 - IPV6 (exact match of source/destination addresses,
163   IP transport protocol)
164
165 - TCP (exact match of source/destination ports)
166
167 - UDP (exact match of source/destination ports)
168
169 - VXLAN (exact match of VXLAN network identifier)
170
171 - GENEVE (exact match of virtual network identifier, only Ethernet (0x6558)
172   protocol type is supported)
173
174 - NVGRE (exact match of virtual subnet ID)
175
176 Supported actions:
177
178 - VOID
179
180 - QUEUE
181
182 - RSS
183
184 - DROP
185
186 - FLAG (supported only with ef10_essb Rx datapath)
187
188 - MARK (supported only with ef10_essb Rx datapath)
189
190 Validating flow rules depends on the firmware variant.
191
192 The :ref:`flow_isolated_mode` is supported.
193
194 Ethernet destination individual/group match
195 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
196
197 Ethernet item supports I/G matching, if only the corresponding bit is set
198 in the mask of destination address. If destination address in the spec is
199 multicast, it matches all multicast (and broadcast) packets, otherwise it
200 matches unicast packets that are not filtered by other flow rules.
201
202 Exceptions to flow rules
203 ~~~~~~~~~~~~~~~~~~~~~~~~
204
205 There is a list of exceptional flow rule patterns which will not be
206 accepted by the PMD. A pattern will be rejected if at least one of the
207 conditions is met:
208
209 - Filtering by IPv4 or IPv6 EtherType without pattern items of internet
210   layer and above.
211
212 - The last item is IPV4 or IPV6, and it's empty.
213
214 - Filtering by TCP or UDP IP transport protocol without pattern items of
215   transport layer and above.
216
217 - The last item is TCP or UDP, and it's empty.
218
219
220 Supported NICs
221 --------------
222
223 - Xilinx Adapters:
224
225    - Alveo SN1022 SmartNIC
226
227 - Solarflare XtremeScale Adapters:
228
229    - Solarflare X2522 Dual Port SFP28 10/25GbE Adapter
230
231    - Solarflare X2541 Single Port QSFP28 10/25G/100G Adapter
232
233    - Solarflare X2542 Dual Port QSFP28 10/25G/100G Adapter
234
235 - Solarflare Flareon [Ultra] Server Adapters:
236
237    - Solarflare SFN8522 Dual Port SFP+ Server Adapter
238
239    - Solarflare SFN8522M Dual Port SFP+ Server Adapter
240
241    - Solarflare SFN8042 Dual Port QSFP+ Server Adapter
242
243    - Solarflare SFN8542 Dual Port QSFP+ Server Adapter
244
245    - Solarflare SFN8722 Dual Port SFP+ OCP Server Adapter
246
247    - Solarflare SFN7002F Dual Port SFP+ Server Adapter
248
249    - Solarflare SFN7004F Quad Port SFP+ Server Adapter
250
251    - Solarflare SFN7042Q Dual Port QSFP+ Server Adapter
252
253    - Solarflare SFN7122F Dual Port SFP+ Server Adapter
254
255    - Solarflare SFN7124F Quad Port SFP+ Server Adapter
256
257    - Solarflare SFN7142Q Dual Port QSFP+ Server Adapter
258
259    - Solarflare SFN7322F Precision Time Synchronization Server Adapter
260
261
262 Prerequisites
263 -------------
264
265 - Requires firmware version:
266
267    - SFN7xxx: **4.7.1.1001** or higher
268
269    - SFN8xxx: **6.0.2.1004** or higher
270
271 Visit `Solarflare Support Downloads <https://support.solarflare.com>`_ to get
272 Solarflare Utilities (either Linux or FreeBSD) with the latest firmware.
273 Follow instructions from Solarflare Server Adapter User's Guide to
274 update firmware and configure the adapter.
275
276
277 Pre-Installation Configuration
278 ------------------------------
279
280
281 Build Options
282 ~~~~~~~~~~~~~
283
284 The following build-time options may be enabled on build time using
285 ``-Dc_args=`` meson argument (e.g.  ``-Dc_args=-DRTE_LIBRTE_SFC_EFX_DEBUG``).
286
287 Please note that enabling debugging options may affect system performance.
288
289 - ``RTE_LIBRTE_SFC_EFX_DEBUG`` (undefined by default)
290
291   Enable compilation of the extra run-time consistency checks.
292
293
294 Per-Device Parameters
295 ~~~~~~~~~~~~~~~~~~~~~
296
297 The following per-device parameters can be passed via EAL PCI device
298 whitelist option like "-w 02:00.0,arg1=value1,...".
299
300 Case-insensitive 1/y/yes/on or 0/n/no/off may be used to specify
301 boolean parameters value.
302
303 - ``rx_datapath`` [auto|efx|ef10|ef10_essb] (default **auto**)
304
305   Choose receive datapath implementation.
306   **auto** allows the driver itself to make a choice based on firmware
307   features available and required by the datapath implementation.
308   **efx** chooses libefx-based datapath which supports Rx scatter.
309   Supported for SFN7xxx, SFN8xxx and X2xxx family adapters only.
310   **ef10** chooses EF10 (SFN7xxx, SFN8xxx, X2xxx) native datapath which is
311   more efficient than libefx-based and provides richer packet type
312   classification.
313   **ef10_essb** chooses SFNX2xxx equal stride super-buffer datapath
314   which may be used on DPDK firmware variant only
315   (see notes about its limitations above).
316   **ef100** chooses EF100 native datapath which is the only supported
317   Rx datapath for EF100 architecture based NICs.
318
319 - ``tx_datapath`` [auto|efx|ef10|ef10_simple|ef100] (default **auto**)
320
321   Choose transmit datapath implementation.
322   **auto** allows the driver itself to make a choice based on firmware
323   features available and required by the datapath implementation.
324   **efx** chooses libefx-based datapath which supports VLAN insertion
325   (full-feature firmware variant only), TSO and multi-segment mbufs.
326   Mbuf segments may come from different mempools, and mbuf reference
327   counters are treated responsibly.
328   Supported for SFN7xxx, SFN8xxx and X2xxx family adapters only.
329   **ef10** chooses EF10 (SFN7xxx, SFN8xxx, X2xxx) native datapath which is
330   more efficient than libefx-based but has no VLAN insertion support yet.
331   Mbuf segments may come from different mempools, and mbuf reference
332   counters are treated responsibly.
333   **ef10_simple** chooses EF10 (SFN7xxx, SFN8xxx, X2xxx) native datapath which
334   is even more faster then **ef10** but does not support multi-segment
335   mbufs, disallows multiple mempools and neglects mbuf reference counters.
336   **ef100** chooses EF100 native datapath which supports multi-segment
337   mbufs, VLAN insertion, inner/outer IPv4 and TCP/UDP checksum and TCP
338   segmentation offloads including VXLAN and GENEVE IPv4/IPv6 tunnels.
339
340 - ``perf_profile`` [auto|throughput|low-latency] (default **throughput**)
341
342   Choose hardware tuning to be optimized for either throughput or
343   low-latency.
344   **auto** allows NIC firmware to make a choice based on
345   installed licenses and firmware variant configured using **sfboot**.
346
347 - ``stats_update_period_ms`` [long] (default **1000**)
348
349   Adjust period in milliseconds to update port hardware statistics.
350   The accepted range is 0 to 65535. The value of **0** may be used
351   to disable periodic statistics update. One should note that it's
352   only possible to set an arbitrary value on SFN8xxx and X2xxx provided that
353   firmware version is 6.2.1.1033 or higher, otherwise any positive
354   value will select a fixed update period of **1000** milliseconds
355
356 - ``fw_variant`` [dont-care|full-feature|ultra-low-latency|
357   capture-packed-stream|dpdk] (default **dont-care**)
358
359   Choose the preferred firmware variant to use.
360   The parameter is supported for SFN7xxX, SFN8xxx and X2xxx families only.
361   In order for the selected option to have an effect, the **sfboot** utility
362   must be configured with the **auto** firmware-variant option.
363   The preferred firmware variant applies to all ports on the NIC.
364   **dont-care** ensures that the driver can attach to an unprivileged function.
365   The datapath firmware type to use is controlled by the **sfboot**
366   utility.
367   **full-feature** chooses full featured firmware.
368   **ultra-low-latency** chooses firmware with fewer features but lower latency.
369   **capture-packed-stream** chooses firmware for SolarCapture packed stream
370   mode.
371   **dpdk** chooses DPDK firmware with equal stride super-buffer Rx mode
372   for higher Rx packet rate and packet marks support and firmware subvariant
373   without checksumming on transmit for higher Tx packet rate if
374   checksumming is not required.
375
376 - ``rxd_wait_timeout_ns`` [long] (default **200 us**)
377
378   Adjust timeout in nanoseconds to head-of-line block to wait for
379   Rx descriptors.
380   The accepted range is 0 to 400 ms.
381   Flow control should be enabled to make it work.
382   The value of **0** disables it and packets are dropped immediately.
383   When a packet is dropped because of no Rx descriptors,
384   ``rx_nodesc_drop_cnt`` counter grows.
385   The feature is supported only by the DPDK firmware variant when equal
386   stride super-buffer Rx mode is used.
387
388
389 Dynamic Logging Parameters
390 ~~~~~~~~~~~~~~~~~~~~~~~~~~
391
392 One may leverage EAL option "--log-level" to change default levels
393 for the log types supported by the driver. The option is used with
394 an argument typically consisting of two parts separated by a colon.
395
396 Level value is the last part which takes a symbolic name (or integer).
397 Log type is the former part which may shell match syntax.
398 Depending on the choice of the expression, the given log level may
399 be used either for some specific log type or for a subset of types.
400
401 SFC EFX PMD provides the following log types available for control:
402
403 - ``pmd.net.sfc.driver`` (default level is **notice**)
404
405   Affects driver-wide messages unrelated to any particular devices.
406
407 - ``pmd.net.sfc.main`` (default level is **notice**)
408
409   Matches a subset of per-port log types registered during runtime.
410   A full name for a particular type may be obtained by appending a
411   dot and a PCI device identifier (``XXXX:XX:XX.X``) to the prefix.
412
413 - ``pmd.net.sfc.mcdi`` (default level is **notice**)
414
415   Extra logging of the communication with the NIC's management CPU.
416   The format of the log is consumed by the Solarflare netlogdecode
417   cross-platform tool. May be managed per-port, as explained above.