net/ngbe: add log and error types
[dpdk.git] / doc / guides / nics / sfc_efx.rst
1 ..  SPDX-License-Identifier: BSD-3-Clause
2     Copyright(c) 2019-2021 Xilinx, Inc.
3     Copyright(c) 2016-2019 Solarflare Communications Inc.
4
5     This software was jointly developed between OKTET Labs (under contract
6     for Solarflare) and Solarflare Communications, Inc.
7
8 Solarflare libefx-based Poll Mode Driver
9 ========================================
10
11 The SFC EFX PMD (**librte_net_sfc_efx**) provides poll mode driver support
12 for **Solarflare SFN7xxx and SFN8xxx** family of 10/40 Gbps adapters,
13 **Solarflare XtremeScale X2xxx** family of 10/25/40/50/100 Gbps adapters and
14 **Alveo SN1000 SmartNICs** family of 10/25/40/50/100 Gbps adapters.
15 SFC EFX PMD has support for the latest Linux and FreeBSD operating systems.
16
17 More information can be found at `Solarflare Communications website
18 <http://solarflare.com>`_.
19
20
21 Features
22 --------
23
24 SFC EFX PMD has support for:
25
26 - Multiple transmit and receive queues
27
28 - Link state information including link status change interrupt
29
30 - IPv4/IPv6 TCP/UDP transmit checksum offload
31
32 - Inner IPv4/IPv6 TCP/UDP transmit checksum offload
33
34 - Port hardware statistics
35
36 - Extended statistics (see Solarflare Server Adapter User's Guide for
37   the statistics description)
38
39 - Basic flow control
40
41 - MTU update
42
43 - Jumbo frames up to 9K
44
45 - Promiscuous mode
46
47 - Allmulticast mode
48
49 - TCP segmentation offload (TSO) including VXLAN and GENEVE encapsulated
50
51 - Multicast MAC filter
52
53 - IPv4/IPv6 TCP/UDP receive checksum offload
54
55 - Inner IPv4/IPv6 TCP/UDP receive checksum offload
56
57 - Received packet type information
58
59 - Receive side scaling (RSS)
60
61 - RSS hash
62
63 - Scattered Rx DMA for packet that are larger that a single Rx descriptor
64
65 - Receive queue interrupts
66
67 - Deferred receive and transmit queue start
68
69 - Transmit VLAN insertion (if running firmware variant supports it)
70
71 - Flow API
72
73 - Loopback
74
75 - SR-IOV PF
76
77
78 Non-supported Features
79 ----------------------
80
81 The features not yet supported include:
82
83 - Priority-based flow control
84
85 - Configurable RX CRC stripping (always stripped)
86
87 - Header split on receive
88
89 - VLAN filtering
90
91 - VLAN stripping
92
93 - LRO
94
95
96 Limitations
97 -----------
98
99 Due to requirements on receive buffer alignment and usage of the receive
100 buffer for the auxiliary packet information provided by the NIC up to
101 extra 269 (14 bytes prefix plus up to 255 bytes for end padding) bytes may be
102 required in the receive buffer.
103 It should be taken into account when mbuf pool for receive is created.
104
105
106 Equal stride super-buffer mode
107 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
108
109 When the receive queue uses equal stride super-buffer DMA mode, one HW Rx
110 descriptor carries many Rx buffers which contiguously follow each other
111 with some stride (equal to total size of rte_mbuf as mempool object).
112 Each Rx buffer is an independent rte_mbuf.
113 However dedicated mempool manager must be used when mempool for the Rx
114 queue is created. The manager must support dequeue of the contiguous
115 block of objects and provide mempool info API to get the block size.
116
117 Another limitation of a equal stride super-buffer mode, imposed by the
118 firmware, is that it allows for a single RSS context.
119
120
121 Tunnels support
122 ---------------
123
124 NVGRE, VXLAN and GENEVE tunnels are supported on SFN8xxx and X2xxx family
125 adapters with full-feature firmware variant running.
126 **sfboot** should be used to configure NIC to run full-feature firmware variant.
127 See Solarflare Server Adapter User's Guide for details.
128
129 SFN8xxx and X2xxx family adapters provide either inner or outer packet classes.
130 If adapter firmware advertises support for tunnels then the PMD
131 configures the hardware to report inner classes, and outer classes are
132 not reported in received packets.
133 However, for VXLAN and GENEVE tunnels the PMD does report UDP as the
134 outer layer 4 packet type.
135
136 SFN8xxx and X2xxx family adapters report GENEVE packets as VXLAN.
137 If UDP ports are configured for only one tunnel type then it is safe to
138 treat VXLAN packet type indication as the corresponding UDP tunnel type.
139
140
141 Flow API support
142 ----------------
143
144 Supported attributes:
145
146 - Ingress
147 - Transfer
148
149 Supported pattern items (***non-transfer*** rules):
150
151 - VOID
152
153 - ETH (exact match of source/destination addresses, individual/group match
154   of destination address, EtherType in the outer frame and exact match of
155   destination addresses, individual/group match of destination address in
156   the inner frame)
157
158 - VLAN (exact match of VID, double-tagging is supported)
159
160 - IPV4 (exact match of source/destination addresses,
161   IP transport protocol)
162
163 - IPV6 (exact match of source/destination addresses,
164   IP transport protocol)
165
166 - TCP (exact match of source/destination ports)
167
168 - UDP (exact match of source/destination ports)
169
170 - VXLAN (exact match of VXLAN network identifier)
171
172 - GENEVE (exact match of virtual network identifier, only Ethernet (0x6558)
173   protocol type is supported)
174
175 - NVGRE (exact match of virtual subnet ID)
176
177 Supported actions (***non-transfer*** rules):
178
179 - VOID
180
181 - QUEUE
182
183 - RSS
184
185 - DROP
186
187 - FLAG (supported only with ef10_essb Rx datapath)
188
189 - MARK (supported only with ef10_essb Rx datapath)
190
191 Supported pattern items (***transfer*** rules):
192
193 - PORT_ID (cannot repeat; conflicts with other traffic source items)
194
195 - PHY_PORT (cannot repeat; conflicts with other traffic source items)
196
197 - PF (cannot repeat; conflicts with other traffic source items)
198
199 - VF (cannot repeat; conflicts with other traffic source items)
200
201 - ETH
202
203 - VLAN (double-tagging is supported)
204
205 - IPV4 (source/destination addresses, IP transport protocol,
206   type of service, time to live)
207
208 - IPV6 (source/destination addresses, IP transport protocol,
209   traffic class, hop limit)
210
211 - TCP (source/destination ports, TCP header length + TCP flags)
212
213 - UDP (source/destination ports)
214
215 - VXLAN (exact match of VXLAN network identifier)
216
217 - GENEVE (exact match of virtual network identifier)
218
219 - NVGRE (exact match of virtual subnet ID)
220
221 Supported actions (***transfer*** rules):
222
223 - OF_POP_VLAN
224
225 - OF_PUSH_VLAN
226
227 - OF_VLAN_SET_VID
228
229 - OF_VLAN_SET_PCP
230
231 - VXLAN_DECAP
232
233 - VXLAN_ENCAP
234
235 - FLAG
236
237 - MARK
238
239 - PHY_PORT
240
241 - PF
242
243 - VF
244
245 - PORT_ID
246
247 - DROP
248
249 Validating flow rules depends on the firmware variant.
250
251 The :ref:`flow_isolated_mode` is supported.
252
253 The implementation is natively thread-safe.
254
255 Ethernet destination individual/group match
256 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
257
258 Ethernet item supports I/G matching, if only the corresponding bit is set
259 in the mask of destination address. If destination address in the spec is
260 multicast, it matches all multicast (and broadcast) packets, otherwise it
261 matches unicast packets that are not filtered by other flow rules.
262
263 Exceptions to flow rules
264 ~~~~~~~~~~~~~~~~~~~~~~~~
265
266 There is a list of exceptional flow rule patterns which will not be
267 accepted by the PMD. A pattern will be rejected if at least one of the
268 conditions is met:
269
270 - Filtering by IPv4 or IPv6 EtherType without pattern items of internet
271   layer and above.
272
273 - The last item is IPV4 or IPV6, and it's empty.
274
275 - Filtering by TCP or UDP IP transport protocol without pattern items of
276   transport layer and above.
277
278 - The last item is TCP or UDP, and it's empty.
279
280
281 Supported NICs
282 --------------
283
284 - Xilinx Adapters:
285
286    - Alveo SN1022 SmartNIC
287
288 - Solarflare XtremeScale Adapters:
289
290    - Solarflare X2522 Dual Port SFP28 10/25GbE Adapter
291
292    - Solarflare X2541 Single Port QSFP28 10/25G/100G Adapter
293
294    - Solarflare X2542 Dual Port QSFP28 10/25G/100G Adapter
295
296 - Solarflare Flareon [Ultra] Server Adapters:
297
298    - Solarflare SFN8522 Dual Port SFP+ Server Adapter
299
300    - Solarflare SFN8522M Dual Port SFP+ Server Adapter
301
302    - Solarflare SFN8042 Dual Port QSFP+ Server Adapter
303
304    - Solarflare SFN8542 Dual Port QSFP+ Server Adapter
305
306    - Solarflare SFN8722 Dual Port SFP+ OCP Server Adapter
307
308    - Solarflare SFN7002F Dual Port SFP+ Server Adapter
309
310    - Solarflare SFN7004F Quad Port SFP+ Server Adapter
311
312    - Solarflare SFN7042Q Dual Port QSFP+ Server Adapter
313
314    - Solarflare SFN7122F Dual Port SFP+ Server Adapter
315
316    - Solarflare SFN7124F Quad Port SFP+ Server Adapter
317
318    - Solarflare SFN7142Q Dual Port QSFP+ Server Adapter
319
320    - Solarflare SFN7322F Precision Time Synchronization Server Adapter
321
322
323 Prerequisites
324 -------------
325
326 - Requires firmware version:
327
328    - SFN7xxx: **4.7.1.1001** or higher
329
330    - SFN8xxx: **6.0.2.1004** or higher
331
332 Visit `Solarflare Support Downloads <https://support.solarflare.com>`_ to get
333 Solarflare Utilities (either Linux or FreeBSD) with the latest firmware.
334 Follow instructions from Solarflare Server Adapter User's Guide to
335 update firmware and configure the adapter.
336
337
338 Pre-Installation Configuration
339 ------------------------------
340
341
342 Build Options
343 ~~~~~~~~~~~~~
344
345 The following build-time options may be enabled on build time using
346 ``-Dc_args=`` meson argument (e.g.  ``-Dc_args=-DRTE_LIBRTE_SFC_EFX_DEBUG``).
347
348 Please note that enabling debugging options may affect system performance.
349
350 - ``RTE_LIBRTE_SFC_EFX_DEBUG`` (undefined by default)
351
352   Enable compilation of the extra run-time consistency checks.
353
354
355 Per-Device Parameters
356 ~~~~~~~~~~~~~~~~~~~~~
357
358 The following per-device parameters can be passed via EAL PCI device
359 allow option like "-a 02:00.0,arg1=value1,...".
360
361 Case-insensitive 1/y/yes/on or 0/n/no/off may be used to specify
362 boolean parameters value.
363
364 - ``class`` [net|vdpa] (default **net**)
365
366   Choose the mode of operation of ef100 device.
367   **net** device will work as network device and will be probed by net/sfc driver.
368   **vdpa** device will work as vdpa device and will be probed by vdpa/sfc driver.
369   If this parameter is not specified then ef100 device will operate as
370   network device.
371
372 - ``rx_datapath`` [auto|efx|ef10|ef10_essb] (default **auto**)
373
374   Choose receive datapath implementation.
375   **auto** allows the driver itself to make a choice based on firmware
376   features available and required by the datapath implementation.
377   **efx** chooses libefx-based datapath which supports Rx scatter.
378   Supported for SFN7xxx, SFN8xxx and X2xxx family adapters only.
379   **ef10** chooses EF10 (SFN7xxx, SFN8xxx, X2xxx) native datapath which is
380   more efficient than libefx-based and provides richer packet type
381   classification.
382   **ef10_essb** chooses SFNX2xxx equal stride super-buffer datapath
383   which may be used on DPDK firmware variant only
384   (see notes about its limitations above).
385   **ef100** chooses EF100 native datapath which is the only supported
386   Rx datapath for EF100 architecture based NICs.
387
388 - ``tx_datapath`` [auto|efx|ef10|ef10_simple|ef100] (default **auto**)
389
390   Choose transmit datapath implementation.
391   **auto** allows the driver itself to make a choice based on firmware
392   features available and required by the datapath implementation.
393   **efx** chooses libefx-based datapath which supports VLAN insertion
394   (full-feature firmware variant only), TSO and multi-segment mbufs.
395   Mbuf segments may come from different mempools, and mbuf reference
396   counters are treated responsibly.
397   Supported for SFN7xxx, SFN8xxx and X2xxx family adapters only.
398   **ef10** chooses EF10 (SFN7xxx, SFN8xxx, X2xxx) native datapath which is
399   more efficient than libefx-based but has no VLAN insertion support yet.
400   Mbuf segments may come from different mempools, and mbuf reference
401   counters are treated responsibly.
402   **ef10_simple** chooses EF10 (SFN7xxx, SFN8xxx, X2xxx) native datapath which
403   is even more faster then **ef10** but does not support multi-segment
404   mbufs, disallows multiple mempools and neglects mbuf reference counters.
405   **ef100** chooses EF100 native datapath which supports multi-segment
406   mbufs, VLAN insertion, inner/outer IPv4 and TCP/UDP checksum and TCP
407   segmentation offloads including VXLAN and GENEVE IPv4/IPv6 tunnels.
408
409 - ``perf_profile`` [auto|throughput|low-latency] (default **throughput**)
410
411   Choose hardware tuning to be optimized for either throughput or
412   low-latency.
413   **auto** allows NIC firmware to make a choice based on
414   installed licenses and firmware variant configured using **sfboot**.
415
416 - ``stats_update_period_ms`` [long] (default **1000**)
417
418   Adjust period in milliseconds to update port hardware statistics.
419   The accepted range is 0 to 65535. The value of **0** may be used
420   to disable periodic statistics update. One should note that it's
421   only possible to set an arbitrary value on SFN8xxx and X2xxx provided that
422   firmware version is 6.2.1.1033 or higher, otherwise any positive
423   value will select a fixed update period of **1000** milliseconds
424
425 - ``fw_variant`` [dont-care|full-feature|ultra-low-latency|
426   capture-packed-stream|dpdk] (default **dont-care**)
427
428   Choose the preferred firmware variant to use.
429   The parameter is supported for SFN7xxX, SFN8xxx and X2xxx families only.
430   In order for the selected option to have an effect, the **sfboot** utility
431   must be configured with the **auto** firmware-variant option.
432   The preferred firmware variant applies to all ports on the NIC.
433   **dont-care** ensures that the driver can attach to an unprivileged function.
434   The datapath firmware type to use is controlled by the **sfboot**
435   utility.
436   **full-feature** chooses full featured firmware.
437   **ultra-low-latency** chooses firmware with fewer features but lower latency.
438   **capture-packed-stream** chooses firmware for SolarCapture packed stream
439   mode.
440   **dpdk** chooses DPDK firmware with equal stride super-buffer Rx mode
441   for higher Rx packet rate and packet marks support and firmware subvariant
442   without checksumming on transmit for higher Tx packet rate if
443   checksumming is not required.
444
445 - ``rxd_wait_timeout_ns`` [long] (default **200 us**)
446
447   Adjust timeout in nanoseconds to head-of-line block to wait for
448   Rx descriptors.
449   The accepted range is 0 to 400 ms.
450   Flow control should be enabled to make it work.
451   The value of **0** disables it and packets are dropped immediately.
452   When a packet is dropped because of no Rx descriptors,
453   ``rx_nodesc_drop_cnt`` counter grows.
454   The feature is supported only by the DPDK firmware variant when equal
455   stride super-buffer Rx mode is used.
456
457
458 Dynamic Logging Parameters
459 ~~~~~~~~~~~~~~~~~~~~~~~~~~
460
461 One may leverage EAL option "--log-level" to change default levels
462 for the log types supported by the driver. The option is used with
463 an argument typically consisting of two parts separated by a colon.
464
465 Level value is the last part which takes a symbolic name (or integer).
466 Log type is the former part which may shell match syntax.
467 Depending on the choice of the expression, the given log level may
468 be used either for some specific log type or for a subset of types.
469
470 SFC EFX PMD provides the following log types available for control:
471
472 - ``pmd.net.sfc.driver`` (default level is **notice**)
473
474   Affects driver-wide messages unrelated to any particular devices.
475
476 - ``pmd.net.sfc.main`` (default level is **notice**)
477
478   Matches a subset of per-port log types registered during runtime.
479   A full name for a particular type may be obtained by appending a
480   dot and a PCI device identifier (``XXXX:XX:XX.X``) to the prefix.
481
482 - ``pmd.net.sfc.mcdi`` (default level is **notice**)
483
484   Extra logging of the communication with the NIC's management CPU.
485   The format of the log is consumed by the Solarflare netlogdecode