net/sfc: support UDP tunnel ports configuration
[dpdk.git] / doc / guides / nics / sfc_efx.rst
1 ..  BSD LICENSE
2     Copyright (c) 2016 Solarflare Communications Inc.
3     All rights reserved.
4
5     This software was jointly developed between OKTET Labs (under contract
6     for Solarflare) and Solarflare Communications, Inc.
7
8     Redistribution and use in source and binary forms, with or without
9     modification, are permitted provided that the following conditions are met:
10
11     1. Redistributions of source code must retain the above copyright notice,
12        this list of conditions and the following disclaimer.
13     2. Redistributions in binary form must reproduce the above copyright notice,
14        this list of conditions and the following disclaimer in the documentation
15        and/or other materials provided with the distribution.
16
17     THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
18     AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
19     THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
20     PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
21     CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
22     EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO,
23     PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS;
24     OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY,
25     WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
26     OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE,
27     EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
28
29 Solarflare libefx-based Poll Mode Driver
30 ========================================
31
32 The SFC EFX PMD (**librte_pmd_sfc_efx**) provides poll mode driver support
33 for **Solarflare SFN7xxx and SFN8xxx** family of 10/40 Gbps adapters.
34 SFC EFX PMD has support for the latest Linux and FreeBSD operating systems.
35
36 More information can be found at `Solarflare Communications website
37 <http://solarflare.com>`_.
38
39
40 Features
41 --------
42
43 SFC EFX PMD has support for:
44
45 - Multiple transmit and receive queues
46
47 - Link state information including link status change interrupt
48
49 - IPv4/IPv6 TCP/UDP transmit checksum offload
50
51 - Port hardware statistics
52
53 - Extended statistics (see Solarflare Server Adapter User's Guide for
54   the statistics description)
55
56 - Basic flow control
57
58 - MTU update
59
60 - Jumbo frames up to 9K
61
62 - Promiscuous mode
63
64 - Allmulticast mode
65
66 - TCP segmentation offload (TSO)
67
68 - Multicast MAC filter
69
70 - IPv4/IPv6 TCP/UDP receive checksum offload
71
72 - Received packet type information
73
74 - Receive side scaling (RSS)
75
76 - RSS hash
77
78 - Scattered Rx DMA for packet that are larger that a single Rx descriptor
79
80 - Deferred receive and transmit queue start
81
82 - Transmit VLAN insertion (if running firmware variant supports it)
83
84 - Flow API
85
86
87 Non-supported Features
88 ----------------------
89
90 The features not yet supported include:
91
92 - Receive queue interupts
93
94 - Priority-based flow control
95
96 - Loopback
97
98 - Configurable RX CRC stripping (always stripped)
99
100 - Header split on receive
101
102 - VLAN filtering
103
104 - VLAN stripping
105
106 - LRO
107
108
109 Limitations
110 -----------
111
112 Due to requirements on receive buffer alignment and usage of the receive
113 buffer for the auxiliary packet information provided by the NIC up to
114 extra 269 (14 bytes prefix plus up to 255 bytes for end padding) bytes may be
115 required in the receive buffer.
116 It should be taken into account when mbuf pool for receive is created.
117
118
119 Tunnels support
120 ---------------
121
122 NVGRE, VXLAN and GENEVE tunnels are supported on SFN8xxx family adapters
123 with full-feature firmware variant running.
124 **sfboot** should be used to configure NIC to run full-feature firmware variant.
125 See Solarflare Server Adapter User's Guide for details.
126
127
128 Flow API support
129 ----------------
130
131 Supported attributes:
132
133 - Ingress
134
135 Supported pattern items:
136
137 - VOID
138
139 - ETH (exact match of source/destination addresses, individual/group match
140   of destination address, EtherType)
141
142 - VLAN (exact match of VID, double-tagging is supported)
143
144 - IPV4 (exact match of source/destination addresses,
145   IP transport protocol)
146
147 - IPV6 (exact match of source/destination addresses,
148   IP transport protocol)
149
150 - TCP (exact match of source/destination ports)
151
152 - UDP (exact match of source/destination ports)
153
154 Supported actions:
155
156 - VOID
157
158 - QUEUE
159
160 - RSS
161
162 Validating flow rules depends on the firmware variant.
163
164 Ethernet destinaton individual/group match
165 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
166
167 Ethernet item supports I/G matching, if only the corresponding bit is set
168 in the mask of destination address. If destinaton address in the spec is
169 multicast, it matches all multicast (and broadcast) packets, oherwise it
170 matches unicast packets that are not filtered by other flow rules.
171
172
173 Supported NICs
174 --------------
175
176 - Solarflare Flareon [Ultra] Server Adapters:
177
178    - Solarflare SFN8522 Dual Port SFP+ Server Adapter
179
180    - Solarflare SFN8542 Dual Port QSFP+ Server Adapter
181
182    - Solarflare SFN7002F Dual Port SFP+ Server Adapter
183
184    - Solarflare SFN7004F Quad Port SFP+ Server Adapter
185
186    - Solarflare SFN7042Q Dual Port QSFP+ Server Adapter
187
188    - Solarflare SFN7122F Dual Port SFP+ Server Adapter
189
190    - Solarflare SFN7124F Quad Port SFP+ Server Adapter
191
192    - Solarflare SFN7142Q Dual Port QSFP+ Server Adapter
193
194    - Solarflare SFN7322F Precision Time Synchronization Server Adapter
195
196
197 Prerequisites
198 -------------
199
200 - Requires firmware version:
201
202    - SFN7xxx: **4.7.1.1001** or higher
203
204    - SFN8xxx: **6.0.2.1004** or higher
205
206 Visit `Solarflare Support Downloads <https://support.solarflare.com>`_ to get
207 Solarflare Utilities (either Linux or FreeBSD) with the latest firmware.
208 Follow instructions from Solarflare Server Adapter User's Guide to
209 update firmware and configure the adapter.
210
211
212 Pre-Installation Configuration
213 ------------------------------
214
215
216 Config File Options
217 ~~~~~~~~~~~~~~~~~~~
218
219 The following options can be modified in the ``.config`` file.
220 Please note that enabling debugging options may affect system performance.
221
222 - ``CONFIG_RTE_LIBRTE_SFC_EFX_PMD`` (default **y**)
223
224   Enable compilation of Solarflare libefx-based poll-mode driver.
225
226 - ``CONFIG_RTE_LIBRTE_SFC_EFX_DEBUG`` (default **n**)
227
228   Enable compilation of the extra run-time consistency checks.
229
230
231 Per-Device Parameters
232 ~~~~~~~~~~~~~~~~~~~~~
233
234 The following per-device parameters can be passed via EAL PCI device
235 whitelist option like "-w 02:00.0,arg1=value1,...".
236
237 Case-insensitive 1/y/yes/on or 0/n/no/off may be used to specify
238 boolean parameters value.
239
240 - ``rx_datapath`` [auto|efx|ef10] (default **auto**)
241
242   Choose receive datapath implementation.
243   **auto** allows the driver itself to make a choice based on firmware
244   features available and required by the datapath implementation.
245   **efx** chooses libefx-based datapath which supports Rx scatter.
246   **ef10** chooses EF10 (SFN7xxx, SFN8xxx) native datapath which is
247   more efficient than libefx-based and provides richer packet type
248   classification, but lacks Rx scatter support.
249
250 - ``tx_datapath`` [auto|efx|ef10|ef10_simple] (default **auto**)
251
252   Choose transmit datapath implementation.
253   **auto** allows the driver itself to make a choice based on firmware
254   features available and required by the datapath implementation.
255   **efx** chooses libefx-based datapath which supports VLAN insertion
256   (full-feature firmware variant only), TSO and multi-segment mbufs.
257   Mbuf segments may come from different mempools, and mbuf reference
258   counters are treated responsibly.
259   **ef10** chooses EF10 (SFN7xxx, SFN8xxx) native datapath which is
260   more efficient than libefx-based but has no VLAN insertion and TSO
261   support yet.
262   Mbuf segments may come from different mempools, and mbuf reference
263   counters are treated responsibly.
264   **ef10_simple** chooses EF10 (SFN7xxx, SFN8xxx) native datapath which
265   is even more faster then **ef10** but does not support multi-segment
266   mbufs, disallows multiple mempools and neglects mbuf reference counters.
267
268 - ``perf_profile`` [auto|throughput|low-latency] (default **throughput**)
269
270   Choose hardware tunning to be optimized for either throughput or
271   low-latency.
272   **auto** allows NIC firmware to make a choice based on
273   installed licences and firmware variant configured using **sfboot**.
274
275 - ``debug_init`` [bool] (default **n**)
276
277   Enable extra logging during device initialization and startup.
278
279 - ``mcdi_logging`` [bool] (default **n**)
280
281   Enable extra logging of the communication with the NIC's management CPU.
282   The logging is done using RTE_LOG() with INFO level and PMD type.
283   The format is consumed by the Solarflare netlogdecode cross-platform tool.
284
285 - ``stats_update_period_ms`` [long] (default **1000**)
286
287   Adjust period in milliseconds to update port hardware statistics.
288   The accepted range is 0 to 65535. The value of **0** may be used
289   to disable periodic statistics update. One should note that it's
290   only possible to set an arbitrary value on SFN8xxx provided that
291   firmware version is 6.2.1.1033 or higher, otherwise any positive
292   value will select a fixed update period of **1000** milliseconds