net/mlx5: add option to configure FCS or decapsulation
[dpdk.git] / doc / guides / nics / bnx2x.rst
index 7a94080..ab90d8a 100644 (file)
@@ -1,32 +1,5 @@
-..  BSD LICENSE
+..  SPDX-License-Identifier: BSD-3-Clause
     Copyright (c) 2015 QLogic Corporation
     Copyright (c) 2015 QLogic Corporation
-    All rights reserved.
-
-    Redistribution and use in source and binary forms, with or without
-    modification, are permitted provided that the following conditions
-    are met:
-
-    * Redistributions of source code must retain the above copyright
-    notice, this list of conditions and the following disclaimer.
-    * Redistributions in binary form must reproduce the above copyright
-    notice, this list of conditions and the following disclaimer in
-    the documentation and/or other materials provided with the
-    distribution.
-    * Neither the name of QLogic Corporation nor the names of its
-    contributors may be used to endorse or promote products derived
-    from this software without specific prior written permission.
-
-    THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
-    "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
-    LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
-    A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
-    OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
-    SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
-    LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
-    DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
-    THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
-    (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
-    OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
 
 BNX2X Poll Mode Driver
 ======================
 
 BNX2X Poll Mode Driver
 ======================
@@ -34,7 +7,7 @@ BNX2X Poll Mode Driver
 The BNX2X poll mode driver library (**librte_pmd_bnx2x**) implements support
 for **QLogic 578xx** 10/20 Gbps family of adapters as well as their virtual
 functions (VF) in SR-IOV context. It is supported on several standard Linux
 The BNX2X poll mode driver library (**librte_pmd_bnx2x**) implements support
 for **QLogic 578xx** 10/20 Gbps family of adapters as well as their virtual
 functions (VF) in SR-IOV context. It is supported on several standard Linux
-distros like Red Hat 7.x and SLES12 OS. It is compile-tested under FreeBSD OS.
+distros like RHEL and SLES. It is compile-tested under FreeBSD OS.
 
 More information can be found at `QLogic Corporation's Official Website
 <http://www.qlogic.com>`_.
 
 More information can be found at `QLogic Corporation's Official Website
 <http://www.qlogic.com>`_.
@@ -60,18 +33,31 @@ The features not yet supported include:
 - LRO/TSO offload
 - Checksum offload
 - SR-IOV PF
 - LRO/TSO offload
 - Checksum offload
 - SR-IOV PF
+- Rx TX scatter gather
 
 Co-existence considerations
 ---------------------------
 
 
 Co-existence considerations
 ---------------------------
 
-- BCM578xx being a CNA can have both NIC and Storage personalities.
-  However, coexistence with storage protocol drivers (cnic, bnx2fc and
-  bnx2fi) is not supported on the same adapter. So storage personality
-  has to be disabled on that adapter when used in DPDK applications.
-
-- For SR-IOV case, bnx2x PMD will be used to bind to SR-IOV VF device and
-  Linux native kernel driver (bnx2x) will be attached to SR-IOV PF.
-
+- QLogic 578xx CNAs support Ethernet, iSCSI and FCoE functionalities.
+  These functionalities are supported using QLogic Linux kernel
+  drivers bnx2x, cnic, bnx2i and bnx2fc. DPDK is supported on these
+  adapters using bnx2x PMD.
+
+- When SR-IOV is not enabled on the adapter,
+  QLogic Linux kernel drivers (bnx2x, cnic, bnx2i and bnx2fc) and bnx2x
+  PMD can’t be attached to different PFs on a given QLogic 578xx
+  adapter.
+  A given adapter needs to be completely used by DPDK or Linux drivers.
+  Before binding DPDK driver to one or more PFs on the adapter,
+  please make sure to unbind Linux drivers from all PFs of the adapter.
+  If there are multiple adapters on the system, one or more adapters
+  can be used by DPDK driver completely and other adapters can be used
+  by Linux drivers completely.
+
+- When SR-IOV is enabled on the adapter,
+  Linux kernel drivers (bnx2x, cnic, bnx2i and bnx2fc) can be bound
+  to the PFs of a given adapter and either bnx2x PMD or Linux drivers
+  bnx2x can be bound to the VFs of the adapter.
 
 Supported QLogic NICs
 ---------------------
 
 Supported QLogic NICs
 ---------------------
@@ -81,9 +67,9 @@ Supported QLogic NICs
 Prerequisites
 -------------
 
 Prerequisites
 -------------
 
-- Requires firmware version **7.2.51.0**. It is inbox on most of the
+- Requires firmware version **7.13.11.0**. It is included in most of the
   standard Linux distros. If it is not available visit
   standard Linux distros. If it is not available visit
-  `QLogic Driver Download Center <http://driverdownloads.qlogic.com>`_
+  `linux-firmware git repository <https://git.kernel.org/pub/scm/linux/kernel/git/firmware/linux-firmware.git/plain/bnx2x/bnx2x-e2-7.13.11.0.fw>`_
   to get the required firmware.
 
 Pre-Installation Configuration
   to get the required firmware.
 
 Pre-Installation Configuration
@@ -95,17 +81,11 @@ Config File Options
 The following options can be modified in the ``.config`` file. Please note that
 enabling debugging options may affect system performance.
 
 The following options can be modified in the ``.config`` file. Please note that
 enabling debugging options may affect system performance.
 
-- ``CONFIG_RTE_LIBRTE_BNX2X_PMD`` (default **y**)
-
-  Toggle compilation of bnx2x driver.
-
-- ``CONFIG_RTE_LIBRTE_BNX2X_DEBUG`` (default **n**)
+- ``CONFIG_RTE_LIBRTE_BNX2X_PMD`` (default **n**)
 
 
-  Toggle display of generic debugging messages.
-
-- ``CONFIG_RTE_LIBRTE_BNX2X_DEBUG_INIT`` (default **n**)
-
-  Toggle display of initialization related messages.
+  Toggle compilation of bnx2x driver. To use bnx2x PMD set this config parameter
+  to 'y'. Also, in order for firmware binary to load user will need zlib devel
+  package installed.
 
 - ``CONFIG_RTE_LIBRTE_BNX2X_DEBUG_TX`` (default **n**)
 
 
 - ``CONFIG_RTE_LIBRTE_BNX2X_DEBUG_TX`` (default **n**)
 
@@ -122,127 +102,31 @@ enabling debugging options may affect system performance.
 
 .. _bnx2x_driver-compilation:
 
 
 .. _bnx2x_driver-compilation:
 
-Driver Compilation
-~~~~~~~~~~~~~~~~~~
-
-BNX2X PMD for Linux x86_64 gcc target, run the following "make"
-command::
-
-   cd <DPDK-source-directory>
-   make config T=x86_64-native-linuxapp-gcc install
-
-To compile BNX2X PMD for Linux x86_64 clang target, run the following "make"
-command::
-
-   cd <DPDK-source-directory>
-   make config T=x86_64-native-linuxapp-clang install
-
-To compile BNX2X PMD for Linux i686 gcc target, run the following "make"
-command::
-
-   cd <DPDK-source-directory>
-   make config T=i686-native-linuxapp-gcc install
-
-To compile BNX2X PMD for FreeBSD x86_64 clang target, run the following "gmake"
-command::
-
-   cd <DPDK-source-directory>
-   gmake config T=x86_64-native-bsdapp-clang install
-
-To compile BNX2X PMD for FreeBSD x86_64 gcc target, run the following "gmake"
-command::
-
-   cd <DPDK-source-directory>
-   gmake config T=x86_64-native-bsdapp-gcc install -Wl,-rpath=/usr/local/lib/gcc48 CC=gcc48
-
-Linux
------
-
-.. _bnx2x_Linux-installation:
-
-Linux Installation
-~~~~~~~~~~~~~~~~~~
-
-Sample Application Notes
-~~~~~~~~~~~~~~~~~~~~~~~~
-
-This section demonstrates how to launch ``testpmd`` with QLogic 578xx
-devices managed by ``librte_pmd_bnx2x`` in Linux operating system.
-
-#. Request huge pages:
-
-   .. code-block:: console
-
-      echo 1024 > /sys/kernel/mm/hugepages/hugepages-2048kB/nr_hugepages/nr_hugepages
-
-#. Load ``igb_uio`` or ``vfio-pci`` driver:
-
-   .. code-block:: console
-
-      insmod ./x86_64-native-linuxapp-gcc/kmod/igb_uio.ko
-
-   or
-
-   .. code-block:: console
-
-      modprobe vfio-pci
-
-#. Bind the QLogic adapters to ``igb_uio`` or ``vfio-pci`` loaded in the
-   previous step::
-
-      ./tools/dpdk_nic_bind.py --bind igb_uio 0000:84:00.0 0000:84:00.1
-
-   or
-
-   Setup VFIO permissions for regular users and then bind to ``vfio-pci``:
-
-   .. code-block:: console
-
-      sudo chmod a+x /dev/vfio
+Driver compilation and testing
+------------------------------
 
 
-      sudo chmod 0666 /dev/vfio/*
+Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
+for details.
 
 
-      ./tools/dpdk_nic_bind.py --bind vfio-pci 0000:84:00.0 0000:84:00.1
+Jumbo: Limitation
+-----------------
 
 
-#. Start ``testpmd`` with basic parameters:
+Rx descriptor limit for number of segments per MTU is set to 1.
+PMD doesn't support Jumbo Rx scatter gather. Some applciations can
+adjust mbuf_size based on this param and max_pkt_len.
 
 
-   .. code-block:: console
+For others, PMD detects the condition where Rx packet length cannot
+be held by configured mbuf size and logs the message.
 
 
-      ./x86_64-native-linuxapp-gcc/app/testpmd -c 0xf -n 4 -- -i
-
-   Example output:
+Example output:
 
    .. code-block:: console
 
       [...]
 
    .. code-block:: console
 
       [...]
-      EAL: PCI device 0000:84:00.0 on NUMA socket 1
-      EAL:   probe driver: 14e4:168e rte_bnx2x_pmd
-      EAL:   PCI memory mapped at 0x7f14f6fe5000
-      EAL:   PCI memory mapped at 0x7f14f67e5000
-      EAL:   PCI memory mapped at 0x7f15fbd9b000
-      EAL: PCI device 0000:84:00.1 on NUMA socket 1
-      EAL:   probe driver: 14e4:168e rte_bnx2x_pmd
-      EAL:   PCI memory mapped at 0x7f14f5fe5000
-      EAL:   PCI memory mapped at 0x7f14f57e5000
-      EAL:   PCI memory mapped at 0x7f15fbd4f000
-      Interactive-mode selected
-      Configuring Port 0 (socket 0)
-      PMD: bnx2x_dev_tx_queue_setup(): fp[00] req_bd=512, thresh=512,
-                   usable_bd=1020, total_bd=1024,
-                                tx_pages=4
-      PMD: bnx2x_dev_rx_queue_setup(): fp[00] req_bd=128, thresh=0,
-                   usable_bd=510, total_bd=512,
-                                rx_pages=1, cq_pages=8
-      PMD: bnx2x_print_adapter_info():
-      [...]
-      Checking link statuses...
-      Port 0 Link Up - speed 10000 Mbps - full-duplex
-      Port 1 Link Up - speed 10000 Mbps - full-duplex
-      Done
-      testpmd>
+      [bnx2x_recv_pkts:397(04:00.0:dpdk-port-0)] mbuf size 2048 is not enough to hold Rx packet length more than 2046
 
 SR-IOV: Prerequisites and sample Application Notes
 
 SR-IOV: Prerequisites and sample Application Notes
-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+--------------------------------------------------
 
 This section provides instructions to configure SR-IOV with Linux OS.
 
 
 This section provides instructions to configure SR-IOV with Linux OS.
 
@@ -294,10 +178,9 @@ This section provides instructions to configure SR-IOV with Linux OS.
 
       echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
 
 
       echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
 
-
 #. Assign VF MAC address:
 
 #. Assign VF MAC address:
 
-   Assign MAC address to the VF using iproute2 ulility. The syntax is:
+   Assign MAC address to the VF using iproute2 utility. The syntax is:
    ip link set <PF iface> vf <VF id> mac <macaddr>
 
    Example output:
    ip link set <PF iface> vf <VF id> mac <macaddr>
 
    Example output:
@@ -306,9 +189,46 @@ This section provides instructions to configure SR-IOV with Linux OS.
 
       ip link set ens5f0 vf 0 mac 52:54:00:2f:9d:e8
 
 
       ip link set ens5f0 vf 0 mac 52:54:00:2f:9d:e8
 
-
-#. PCI passthrough:
+#. PCI Passthrough:
 
    The VF devices may be passed through to the guest VM using virt-manager or
    virsh etc. bnx2x PMD should be used to bind the VF devices in the guest VM
    using the instructions outlined in the Application notes below.
 
    The VF devices may be passed through to the guest VM using virt-manager or
    virsh etc. bnx2x PMD should be used to bind the VF devices in the guest VM
    using the instructions outlined in the Application notes below.
+
+#. Running testpmd:
+   (Supply ``--log-level="pmd.net.bnx2x.driver",7`` to view informational messages):
+
+   Follow instructions available in the document
+   :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
+   to run testpmd.
+
+   Example output:
+
+   .. code-block:: console
+
+      [...]
+      EAL: PCI device 0000:84:00.0 on NUMA socket 1
+      EAL:   probe driver: 14e4:168e rte_bnx2x_pmd
+      EAL:   PCI memory mapped at 0x7f14f6fe5000
+      EAL:   PCI memory mapped at 0x7f14f67e5000
+      EAL:   PCI memory mapped at 0x7f15fbd9b000
+      EAL: PCI device 0000:84:00.1 on NUMA socket 1
+      EAL:   probe driver: 14e4:168e rte_bnx2x_pmd
+      EAL:   PCI memory mapped at 0x7f14f5fe5000
+      EAL:   PCI memory mapped at 0x7f14f57e5000
+      EAL:   PCI memory mapped at 0x7f15fbd4f000
+      Interactive-mode selected
+      Configuring Port 0 (socket 0)
+      PMD: bnx2x_dev_tx_queue_setup(): fp[00] req_bd=512, thresh=512,
+                   usable_bd=1020, total_bd=1024,
+                                tx_pages=4
+      PMD: bnx2x_dev_rx_queue_setup(): fp[00] req_bd=128, thresh=0,
+                   usable_bd=510, total_bd=512,
+                                rx_pages=1, cq_pages=8
+      PMD: bnx2x_print_adapter_info():
+      [...]
+      Checking link statuses...
+      Port 0 Link Up - speed 10000 Mbps - full-duplex
+      Port 1 Link Up - speed 10000 Mbps - full-duplex
+      Done