app/testpmd: introduce Rx offloads option
[dpdk.git] / doc / guides / nics / enic.rst
index 89a3015..65e536d 100644 (file)
@@ -1,32 +1,7 @@
-..  BSD LICENSE
+..  SPDX-License-Identifier: BSD-3-Clause
     Copyright (c) 2017, Cisco Systems, Inc.
     All rights reserved.
 
     Copyright (c) 2017, Cisco Systems, Inc.
     All rights reserved.
 
-    Redistribution and use in source and binary forms, with or without
-    modification, are permitted provided that the following conditions
-    are met:
-
-    1. Redistributions of source code must retain the above copyright
-    notice, this list of conditions and the following disclaimer.
-
-    2. Redistributions in binary form must reproduce the above copyright
-    notice, this list of conditions and the following disclaimer in
-    the documentation and/or other materials provided with the
-    distribution.
-
-    THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
-    "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
-    LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
-    FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
-    COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
-    INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
-    BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
-    LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
-    CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
-    LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
-    ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
-    POSSIBILITY OF SUCH DAMAGE.
-
 ENIC Poll Mode Driver
 =====================
 
 ENIC Poll Mode Driver
 =====================
 
@@ -39,7 +14,7 @@ How to obtain ENIC PMD integrated DPDK
 --------------------------------------
 
 ENIC PMD support is integrated into the DPDK suite. dpdk-<version>.tar.gz
 --------------------------------------
 
 ENIC PMD support is integrated into the DPDK suite. dpdk-<version>.tar.gz
-should be downloaded from http://dpdk.org
+should be downloaded from http://core.dpdk.org/download/
 
 
 Configuration information
 
 
 Configuration information
@@ -52,9 +27,6 @@ Configuration information
   - **CONFIG_RTE_LIBRTE_ENIC_PMD** (default y): Enables or disables inclusion
     of the ENIC PMD driver in the DPDK compilation.
 
   - **CONFIG_RTE_LIBRTE_ENIC_PMD** (default y): Enables or disables inclusion
     of the ENIC PMD driver in the DPDK compilation.
 
-  - **CONFIG_RTE_LIBRTE_ENIC_DEBUG** (default n): Enables or disables debug
-    logging within the ENIC PMD driver.
-
 - **vNIC Configuration Parameters**
 
   - **Number of Queues**
 - **vNIC Configuration Parameters**
 
   - **Number of Queues**
@@ -66,7 +38,7 @@ Configuration information
     These values should be configured as follows:
 
     - The number of WQs should be greater or equal to the value of the
     These values should be configured as follows:
 
     - The number of WQs should be greater or equal to the value of the
-      expected nb_tx_q parameter in the call to the
+      expected nb_tx_q parameter in the call to
       rte_eth_dev_configure()
 
     - The number of RQs configured in the vNIC should be greater or
       rte_eth_dev_configure()
 
     - The number of RQs configured in the vNIC should be greater or
@@ -88,7 +60,7 @@ Configuration information
   - **Size of Queues**
 
     Likewise, the number of receive and transmit descriptors are configurable on
   - **Size of Queues**
 
     Likewise, the number of receive and transmit descriptors are configurable on
-    a per vNIC bases via the UCS Manager and should be greater than or equal to
+    a per-vNIC basis via the UCS Manager and should be greater than or equal to
     the nb_rx_desc and   nb_tx_desc parameters expected to be used in the calls
     to rte_eth_rx_queue_setup() and rte_eth_tx_queue_setup() respectively.
     An application requesting more than the set size will be limited to that
     the nb_rx_desc and   nb_tx_desc parameters expected to be used in the calls
     to rte_eth_rx_queue_setup() and rte_eth_tx_queue_setup() respectively.
     An application requesting more than the set size will be limited to that
@@ -101,7 +73,7 @@ Configuration information
 
     - *Note*: Since the introduction of Rx scatter, for performance
       reasons, this PMD uses two RQs on the vNIC per receive queue in
 
     - *Note*: Since the introduction of Rx scatter, for performance
       reasons, this PMD uses two RQs on the vNIC per receive queue in
-      DPDK.  One RQ holds descriptors for the start of a packet the
+      DPDK.  One RQ holds descriptors for the start of a packet, and the
       second RQ holds the descriptors for the rest of the fragments of
       a packet.  This means that the nb_rx_desc parameter to
       rte_eth_rx_queue_setup() can be a greater than 4096.  The exact
       second RQ holds the descriptors for the rest of the fragments of
       a packet.  This means that the nb_rx_desc parameter to
       rte_eth_rx_queue_setup() can be a greater than 4096.  The exact
@@ -110,53 +82,49 @@ Configuration information
 
       For example: If the mbuf size is 2048, and the MTU is 9000, then
       receiving a full size packet will take 5 descriptors, 1 from the
 
       For example: If the mbuf size is 2048, and the MTU is 9000, then
       receiving a full size packet will take 5 descriptors, 1 from the
-      start of packet queue, and 4 from the second queue.  Assuming
+      start-of-packet queue, and 4 from the second queue.  Assuming
       that the RQ size was set to the maximum of 4096, then the
       application can specify up to 1024 + 4096 as the nb_rx_desc
       parameter to rte_eth_rx_queue_setup().
 
   - **Interrupts**
 
       that the RQ size was set to the maximum of 4096, then the
       application can specify up to 1024 + 4096 as the nb_rx_desc
       parameter to rte_eth_rx_queue_setup().
 
   - **Interrupts**
 
-    Only one interrupt per vNIC interface should be configured in the UCS
+    At least one interrupt per vNIC interface should be configured in the UCS
     manager regardless of the number receive/transmit queues. The ENIC PMD
     uses this interrupt to get information about link status and errors
     in the fast path.
 
     manager regardless of the number receive/transmit queues. The ENIC PMD
     uses this interrupt to get information about link status and errors
     in the fast path.
 
-.. _enic-flow-director:
+    In addition to the interrupt for link status and errors, when using Rx queue
+    interrupts, increase the number of configured interrupts so that there is at
+    least one interrupt for each Rx queue. For example, if the app uses 3 Rx
+    queues and wants to use per-queue interrupts, configure 4 (3 + 1) interrupts.
 
 
-Flow director support
----------------------
+  - **Receive Side Scaling**
 
 
-Advanced filtering support was added to 1300 series VIC firmware starting
-with version 2.0.13 for C-series UCS servers and version 3.1.2 for UCSM
-managed blade servers. In order to enable advanced filtering the 'Advanced
-filter' radio button should be enabled via CIMC or UCSM followed by a reboot
-of the server.
+    In order to fully utilize RSS in DPDK, enable all RSS related settings in
+    CIMC or UCSM. These include the following items listed under
+    Receive Side Scaling:
+    TCP, IPv4, TCP-IPv4, IPv6, TCP-IPv6, IPv6 Extension, TCP-IPv6 Extension.
 
 
-With advanced filters, perfect matching of all fields of IPv4, IPv6 headers
-as well as TCP, UDP and SCTP L4 headers is available through flow director.
-Masking of these fields for partial match is also supported.
-
-Without advanced filter support, the flow director is limited to IPv4
-perfect filtering of the 5-tuple with no masking of fields supported.
 
 SR-IOV mode utilization
 -----------------------
 
 
 SR-IOV mode utilization
 -----------------------
 
-UCS blade servers configured with dynamic vNIC connection policies in UCS
-manager are capable of supporting assigned devices on virtual machines (VMs)
-through a KVM hypervisor. Assigned devices, also known as 'passthrough'
-devices, are SR-IOV virtual functions (VFs) on the host which are exposed
-to VM instances.
+UCS blade servers configured with dynamic vNIC connection policies in UCSM
+are capable of supporting SR-IOV. SR-IOV virtual functions (VFs) are
+specialized vNICs, distinct from regular Ethernet vNICs. These VFs can be
+directly assigned to virtual machines (VMs) as 'passthrough' devices.
 
 
-The Cisco Virtual Machine Fabric Extender (VM-FEX) gives the VM a dedicated
+In UCS, SR-IOV VFs require the use of the Cisco Virtual Machine Fabric Extender
+(VM-FEX), which gives the VM a dedicated
 interface on the Fabric Interconnect (FI). Layer 2 switching is done at
 the FI. This may eliminate the requirement for software switching on the
 host to route intra-host VM traffic.
 
 Please refer to `Creating a Dynamic vNIC Connection Policy
 <http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/vm_fex/vmware/gui/config_guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide_chapter_010.html#task_433E01651F69464783A68E66DA8A47A5>`_
 interface on the Fabric Interconnect (FI). Layer 2 switching is done at
 the FI. This may eliminate the requirement for software switching on the
 host to route intra-host VM traffic.
 
 Please refer to `Creating a Dynamic vNIC Connection Policy
 <http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/vm_fex/vmware/gui/config_guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide_chapter_010.html#task_433E01651F69464783A68E66DA8A47A5>`_
-for information on configuring SR-IOV Adapter policies using UCS manager.
+for information on configuring SR-IOV adapter policies and port profiles
+using UCSM.
 
 Once the policies are in place and the host OS is rebooted, VFs should be
 visible on the host, E.g.:
 
 Once the policies are in place and the host OS is rebooted, VFs should be
 visible on the host, E.g.:
@@ -173,30 +141,37 @@ visible on the host, E.g.:
      0d:00.6 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
      0d:00.7 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
 
      0d:00.6 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
      0d:00.7 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
 
-Enable Intel IOMMU on the host and install KVM and libvirt. A VM instance should
-be created with an assigned device. When using libvirt, this configuration can
-be done within the domain (i.e. VM) config file. For example this entry maps
-host VF 0d:00:01 into the VM.
+Enable Intel IOMMU on the host and install KVM and libvirt, and reboot again as
+required. Then, using libvirt, create a VM instance with an assigned device.
+Below is an example ``interface`` block (part of the domain configuration XML)
+that adds the host VF 0d:00:01 to the VM. ``profileid='pp-vlan-25'`` indicates
+the port profile that has been configured in UCSM.
 
 .. code-block:: console
 
     <interface type='hostdev' managed='yes'>
       <mac address='52:54:00:ac:ff:b6'/>
 
 .. code-block:: console
 
     <interface type='hostdev' managed='yes'>
       <mac address='52:54:00:ac:ff:b6'/>
+      <driver name='vfio'/>
       <source>
         <address type='pci' domain='0x0000' bus='0x0d' slot='0x00' function='0x1'/>
       </source>
       <source>
         <address type='pci' domain='0x0000' bus='0x0d' slot='0x00' function='0x1'/>
       </source>
+      <virtualport type='802.1Qbh'>
+        <parameters profileid='pp-vlan-25'/>
+      </virtualport>
+    </interface>
+
 
 Alternatively, the configuration can be done in a separate file using the
 ``network`` keyword. These methods are described in the libvirt documentation for
 `Network XML format <https://libvirt.org/formatnetwork.html>`_.
 
 
 Alternatively, the configuration can be done in a separate file using the
 ``network`` keyword. These methods are described in the libvirt documentation for
 `Network XML format <https://libvirt.org/formatnetwork.html>`_.
 
-When the VM instance is started, the ENIC KVM driver will bind the host VF to
+When the VM instance is started, libvirt will bind the host VF to
 vfio, complete provisioning on the FI and bring up the link.
 
 .. note::
 
     It is not possible to use a VF directly from the host because it is not
 vfio, complete provisioning on the FI and bring up the link.
 
 .. note::
 
     It is not possible to use a VF directly from the host because it is not
-    fully provisioned until the hypervisor brings up the VM that it is assigned
+    fully provisioned until libvirt brings up the VM that it is assigned
     to.
 
 In the VM instance, the VF will now be visible. E.g., here the VF 00:04.0 is
     to.
 
 In the VM instance, the VF will now be visible. E.g., here the VF 00:04.0 is
@@ -210,9 +185,216 @@ seen on the VM instance and should be available for binding to a DPDK.
 Follow the normal DPDK install procedure, binding the VF to either ``igb_uio``
 or ``vfio`` in non-IOMMU mode.
 
 Follow the normal DPDK install procedure, binding the VF to either ``igb_uio``
 or ``vfio`` in non-IOMMU mode.
 
+In the VM, the kernel enic driver may be automatically bound to the VF during
+boot. Unbinding it currently hangs due to a known issue with the driver. To
+work around the issue, blacklist the enic module as follows.
 Please see :ref:`Limitations <enic_limitations>` for limitations in
 the use of SR-IOV.
 
 Please see :ref:`Limitations <enic_limitations>` for limitations in
 the use of SR-IOV.
 
+.. code-block:: console
+
+     # cat /etc/modprobe.d/enic.conf
+     blacklist enic
+
+     # dracut --force
+
+.. note::
+
+    Passthrough does not require SR-IOV. If VM-FEX is not desired, the user
+    may create as many regular vNICs as necessary and assign them to VMs as
+    passthrough devices. Since these vNICs are not SR-IOV VFs, using them as
+    passthrough devices do not require libvirt, port profiles, and VM-FEX.
+
+
+.. _enic-generic-flow-api:
+
+Generic Flow API support
+------------------------
+
+Generic Flow API (also called "rte_flow" API) is supported. More advanced
+capabilities are available when "Advanced Filtering" is enabled on the adapter.
+Advanced filtering was added to 1300 series VIC firmware starting with version
+2.0.13 for C-series UCS servers and version 3.1.2 for UCSM managed blade
+servers. Advanced filtering is available on 1400 series adapters and beyond.
+To enable advanced filtering, the 'Advanced filter' radio button should be
+selected via CIMC or UCSM followed by a reboot of the server.
+
+- **1200 series VICs**
+
+  5-tuple exact flow support for 1200 series adapters. This allows:
+
+  - Attributes: ingress
+  - Items: ipv4, ipv6, udp, tcp (must exactly match src/dst IP
+    addresses and ports and all must be specified)
+  - Actions: queue and void
+  - Selectors: 'is'
+
+- **1300 and later series VICS with advanced filters disabled**
+
+  With advanced filters disabled, an IPv4 or IPv6 item must be specified
+  in the pattern.
+
+  - Attributes: ingress
+  - Items: eth, vlan, ipv4, ipv6, udp, tcp, vxlan, inner eth, vlan, ipv4, ipv6, udp, tcp
+  - Actions: queue and void
+  - Selectors: 'is', 'spec' and 'mask'. 'last' is not supported
+  - In total, up to 64 bytes of mask is allowed across all headers
+
+- **1300 and later series VICS with advanced filters enabled**
+
+  - Attributes: ingress
+  - Items: eth, vlan, ipv4, ipv6, udp, tcp, vxlan, raw, inner eth, vlan, ipv4, ipv6, udp, tcp
+  - Actions: queue, mark, drop, flag, rss, passthru, and void
+  - Selectors: 'is', 'spec' and 'mask'. 'last' is not supported
+  - In total, up to 64 bytes of mask is allowed across all headers
+
+- **1400 and later series VICs with Flow Manager API enabled**
+
+  - Attributes: ingress, egress
+  - Items: eth, vlan, ipv4, ipv6, sctp, udp, tcp, vxlan, raw, inner eth, vlan, ipv4, ipv6, sctp, udp, tcp
+  - Ingress Actions: count, drop, flag, jump, mark, port_id, passthru, queue, rss, vxlan_decap, vxlan_encap, and void
+  - Egress Actions: count, drop, jump, passthru, vxlan_encap, and void
+  - Selectors: 'is', 'spec' and 'mask'. 'last' is not supported
+  - In total, up to 64 bytes of mask is allowed across all headers
+
+The VIC performs packet matching after applying VLAN strip. If VLAN
+stripping is enabled, EtherType in the ETH item corresponds to the
+stripped VLAN header's EtherType. Stripping does not affect the VLAN
+item. TCI and EtherType in the VLAN item are matched against those in
+the (stripped) VLAN header whether stripping is enabled or disabled.
+
+More features may be added in future firmware and new versions of the VIC.
+Please refer to the release notes.
+
+.. _overlay_offload:
+
+Overlay Offload
+---------------
+
+Recent hardware models support overlay offload. When enabled, the NIC performs
+the following operations for VXLAN, NVGRE, and GENEVE packets. In all cases,
+inner and outer packets can be IPv4 or IPv6.
+
+- TSO for VXLAN and GENEVE packets.
+
+  Hardware supports NVGRE TSO, but DPDK currently has no NVGRE offload flags.
+
+- Tx checksum offloads.
+
+  The NIC fills in IPv4/UDP/TCP checksums for both inner and outer packets.
+
+- Rx checksum offloads.
+
+  The NIC validates IPv4/UDP/TCP checksums of both inner and outer packets.
+  Good checksum flags (e.g. ``PKT_RX_L4_CKSUM_GOOD``) indicate that the inner
+  packet has the correct checksum, and if applicable, the outer packet also
+  has the correct checksum. Bad checksum flags (e.g. ``PKT_RX_L4_CKSUM_BAD``)
+  indicate that the inner and/or outer packets have invalid checksum values.
+
+- Inner Rx packet type classification
+
+  PMD sets inner L3/L4 packet types (e.g. ``RTE_PTYPE_INNER_L4_TCP``), and
+  ``RTE_PTYPE_TUNNEL_GRENAT`` to indicate that the packet is tunneled.
+  PMD does not set L3/L4 packet types for outer packets.
+
+- Inner RSS
+
+  RSS hash calculation, therefore queue selection, is done on inner packets.
+
+In order to enable overlay offload, the 'Enable VXLAN' box should be checked
+via CIMC or UCSM followed by a reboot of the server. When PMD successfully
+enables overlay offload, it prints the following message on the console.
+
+.. code-block:: console
+
+    Overlay offload is enabled
+
+By default, PMD enables overlay offload if hardware supports it. To disable
+it, set ``devargs`` parameter ``disable-overlay=1``. For example::
+
+    -w 12:00.0,disable-overlay=1
+
+By default, the NIC uses 4789 as the VXLAN port. The user may change
+it through ``rte_eth_dev_udp_tunnel_port_{add,delete}``. However, as
+the current NIC has a single VXLAN port number, the user cannot
+configure multiple port numbers.
+
+Geneve headers with non-zero options are not supported by default. To
+use Geneve with options, update the VIC firmware to the latest version
+and then set ``devargs`` parameter ``geneve-opt=1``. When Geneve with
+options is enabled, flow API cannot be used as the features are
+currently mutually exclusive. When this feature is successfully
+enabled, PMD prints the following message.
+
+.. code-block:: console
+
+    Geneve with options is enabled
+
+
+Ingress VLAN Rewrite
+--------------------
+
+VIC adapters can tag, untag, or modify the VLAN headers of ingress
+packets. The ingress VLAN rewrite mode controls this behavior. By
+default, it is set to pass-through, where the NIC does not modify the
+VLAN header in any way so that the application can see the original
+header. This mode is sufficient for many applications, but may not be
+suitable for others. Such applications may change the mode by setting
+``devargs`` parameter ``ig-vlan-rewrite`` to one of the following.
+
+- ``pass``: Pass-through mode. The NIC does not modify the VLAN
+  header. This is the default mode.
+
+- ``priority``: Priority-tag default VLAN mode. If the ingress packet
+  is tagged with the default VLAN, the NIC replaces its VLAN header
+  with the priority tag (VLAN ID 0).
+
+- ``trunk``: Default trunk mode. The NIC tags untagged ingress packets
+  with the default VLAN. Tagged ingress packets are not modified. To
+  the application, every packet appears as tagged.
+
+- ``untag``: Untag default VLAN mode. If the ingress packet is tagged
+  with the default VLAN, the NIC removes or untags its VLAN header so
+  that the application sees an untagged packet. As a result, the
+  default VLAN becomes `untagged`. This mode can be useful for
+  applications such as OVS-DPDK performance benchmarks that utilize
+  only the default VLAN and want to see only untagged packets.
+
+
+Vectorized Rx Handler
+---------------------
+
+ENIC PMD includes a version of the receive handler that is vectorized using
+AVX2 SIMD instructions. It is meant for bulk, throughput oriented workloads
+where reducing cycles/packet in PMD is a priority. In order to use the
+vectorized handler, take the following steps.
+
+- Use a recent version of gcc, icc, or clang and build 64-bit DPDK. If
+  the compiler is known to support AVX2, DPDK build system
+  automatically compiles the vectorized handler. Otherwise, the
+  handler is not available.
+
+- Set ``devargs`` parameter ``enable-avx2-rx=1`` to explicitly request that
+  PMD consider the vectorized handler when selecting the receive handler.
+  For example::
+
+    -w 12:00.0,enable-avx2-rx=1
+
+  As the current implementation is intended for field trials, by default, the
+  vectorized handler is not considered (``enable-avx2-rx=0``).
+
+- Run on a UCS M4 or later server with CPUs that support AVX2.
+
+PMD selects the vectorized handler when the handler is compiled into
+the driver, the user requests its use via ``enable-avx2-rx=1``, CPU
+supports AVX2, and scatter Rx is not used. To verify that the
+vectorized handler is selected, enable debug logging
+(``--log-level=pmd,debug``) and check the following message.
+
+.. code-block:: console
+
+    enic_use_vector_rx_handler use the non-scatter avx2 Rx handler
+
 .. _enic_limitations:
 
 Limitations
 .. _enic_limitations:
 
 Limitations
@@ -228,9 +410,10 @@ Limitations
   In test setups where an Ethernet port of a Cisco adapter in TRUNK mode is
   connected point-to-point to another adapter port or connected though a router
   instead of a switch, all ingress packets will be VLAN tagged. Programs such
   In test setups where an Ethernet port of a Cisco adapter in TRUNK mode is
   connected point-to-point to another adapter port or connected though a router
   instead of a switch, all ingress packets will be VLAN tagged. Programs such
-  as l3fwd which do not account for VLAN tags in packets will misbehave. The
-  solution is to enable VLAN stripping on ingress. The follow code fragment is
-  example of how to accomplish this:
+  as l3fwd may not account for VLAN tags in packets and may misbehave. One
+  solution is to enable VLAN stripping on ingress so the VLAN tag is removed
+  from the packet and put into the mbuf->vlan_tci field. Here is an example
+  of how to accomplish this:
 
 .. code-block:: console
 
 
 .. code-block:: console
 
@@ -238,11 +421,13 @@ Limitations
      vlan_offload |= ETH_VLAN_STRIP_OFFLOAD;
      rte_eth_dev_set_vlan_offload(port, vlan_offload);
 
      vlan_offload |= ETH_VLAN_STRIP_OFFLOAD;
      rte_eth_dev_set_vlan_offload(port, vlan_offload);
 
-- Limited flow director support on 1200 series and 1300 series Cisco VIC
-  adapters with old firmware. Please see :ref:`enic-flow-director`.
+Another alternative is modify the adapter's ingress VLAN rewrite mode so that
+packets with the default VLAN tag are stripped by the adapter and presented to
+DPDK as untagged packets. In this case mbuf->vlan_tci and the PKT_RX_VLAN and
+PKT_RX_VLAN_STRIPPED mbuf flags would not be set. This mode is enabled with the
+``devargs`` parameter ``ig-vlan-rewrite=untag``. For example::
 
 
-- Flow director features are not supported on generation 1 Cisco VIC adapters
-  (M81KR and P81E)
+    -w 12:00.0,ig-vlan-rewrite=untag
 
 - **SR-IOV**
 
 
 - **SR-IOV**
 
@@ -252,7 +437,7 @@ Limitations
   - VF devices are not usable directly from the host. They can  only be used
     as assigned devices on VM instances.
   - Currently, unbind of the ENIC kernel mode driver 'enic.ko' on the VM
   - VF devices are not usable directly from the host. They can  only be used
     as assigned devices on VM instances.
   - Currently, unbind of the ENIC kernel mode driver 'enic.ko' on the VM
-    instance may hang. As a workaround, enic.ko should blacklisted or removed
+    instance may hang. As a workaround, enic.ko should be blacklisted or removed
     from the boot process.
   - pci_generic cannot be used as the uio module in the VM. igb_uio or
     vfio in non-IOMMU mode can be used.
     from the boot process.
   - pci_generic cannot be used as the uio module in the VM. igb_uio or
     vfio in non-IOMMU mode can be used.
@@ -260,14 +445,48 @@ Limitations
   - The number of SR-IOV devices is limited to 256. Components on target system
     might limit this number to fewer than 256.
 
   - The number of SR-IOV devices is limited to 256. Components on target system
     might limit this number to fewer than 256.
 
+- **Flow API**
+
+  - The number of filters that can be specified with the Generic Flow API is
+    dependent on how many header fields are being masked. Use 'flow create' in
+    a loop to determine how many filters your VIC will support (not more than
+    1000 for 1300 series VICs). Filters are checked for matching in the order they
+    were added. Since there currently is no grouping or priority support,
+    'catch-all' filters should be added last.
+  - The supported range of IDs for the 'MARK' action is 0 - 0xFFFD.
+  - RSS and PASSTHRU actions only support "receive normally". They are limited
+    to supporting MARK + RSS and PASSTHRU + MARK to allow the application to mark
+    packets and then receive them normally. These require 1400 series VIC adapters
+    and latest firmware.
+  - RAW items are limited to matching UDP tunnel headers like VXLAN.
+
+- **Statistics**
+
+  - ``rx_good_bytes`` (ibytes) always includes VLAN header (4B) and CRC bytes (4B).
+    This behavior applies to 1300 and older series VIC adapters.
+    1400 series VICs do not count CRC bytes, and count VLAN header only when VLAN
+    stripping is disabled.
+  - When the NIC drops a packet because the Rx queue has no free buffers,
+    ``rx_good_bytes`` still increments by 4B if the packet is not VLAN tagged or
+    VLAN stripping is disabled, or by 8B if the packet is VLAN tagged and stripping
+    is enabled.
+    This behavior applies to 1300 and older series VIC adapters. 1400 series VICs
+    do not increment this byte counter when packets are dropped.
+
+- **RSS Hashing**
+
+  - Hardware enables and disables UDP and TCP RSS hashing together. The driver
+    cannot control UDP and TCP hashing individually.
+
 How to build the suite
 ----------------------
 
 How to build the suite
 ----------------------
 
+The build instructions for the DPDK suite should be followed. By default
+the ENIC PMD library will be built into the DPDK library.
+
 Refer to the document :ref:`compiling and testing a PMD for a NIC
 <pmd_build_and_test>` for details.
 
 Refer to the document :ref:`compiling and testing a PMD for a NIC
 <pmd_build_and_test>` for details.
 
-By default the ENIC PMD library will be built into the DPDK library.
-
 For configuring and using UIO and VFIO frameworks, please refer to the
 documentation that comes with DPDK suite.
 
 For configuring and using UIO and VFIO frameworks, please refer to the
 documentation that comes with DPDK suite.
 
@@ -276,17 +495,9 @@ Supported Cisco VIC adapters
 
 ENIC PMD supports all recent generations of Cisco VIC adapters including:
 
 
 ENIC PMD supports all recent generations of Cisco VIC adapters including:
 
-- VIC 1280
-- VIC 1240
-- VIC 1225
-- VIC 1285
-- VIC 1225T
-- VIC 1227
-- VIC 1227T
-- VIC 1380
-- VIC 1340
-- VIC 1385
-- VIC 1387
+- VIC 1200 series
+- VIC 1300 series
+- VIC 1400 series
 
 Supported Operating Systems
 ---------------------------
 
 Supported Operating Systems
 ---------------------------
@@ -304,15 +515,21 @@ Supported features
 - IP checksum offload
 - Receive side VLAN stripping
 - Multiple receive and transmit queues
 - IP checksum offload
 - Receive side VLAN stripping
 - Multiple receive and transmit queues
-- Flow Director ADD, UPDATE, DELETE, STATS operation support IPv4 and IPv6
 - Promiscuous mode
 - Setting RX VLAN (supported via UCSM/CIMC only)
 - VLAN filtering (supported via UCSM/CIMC only)
 - Execution of application by unprivileged system users
 - IPV4, IPV6 and TCP RSS hashing
 - Promiscuous mode
 - Setting RX VLAN (supported via UCSM/CIMC only)
 - VLAN filtering (supported via UCSM/CIMC only)
 - Execution of application by unprivileged system users
 - IPV4, IPV6 and TCP RSS hashing
+- UDP RSS hashing (1400 series and later adapters)
 - Scattered Rx
 - MTU update
 - Scattered Rx
 - MTU update
-- SR-IOV on UCS managed servers connected to Fabric Interconnects.
+- SR-IOV on UCS managed servers connected to Fabric Interconnects
+- Flow API
+- Overlay offload
+
+  - Rx/Tx checksum offloads for VXLAN, NVGRE, GENEVE
+  - TSO for VXLAN and GENEVE packets
+  - Inner RSS
 
 Known bugs and unsupported features in this release
 ---------------------------------------------------
 
 Known bugs and unsupported features in this release
 ---------------------------------------------------
@@ -320,24 +537,24 @@ Known bugs and unsupported features in this release
 - Signature or flex byte based flow direction
 - Drop feature of flow direction
 - VLAN based flow direction
 - Signature or flex byte based flow direction
 - Drop feature of flow direction
 - VLAN based flow direction
-- non-IPV4 flow direction
+- Non-IPV4 flow direction
 - Setting of extended VLAN
 - Setting of extended VLAN
-- UDP RSS hashing
 - MTU update only works if Scattered Rx mode is disabled
 - MTU update only works if Scattered Rx mode is disabled
+- Maximum receive packet length is ignored if Scattered Rx mode is used
 
 Prerequisites
 -------------
 
 - Prepare the system as recommended by DPDK suite.  This includes environment
 
 Prerequisites
 -------------
 
 - Prepare the system as recommended by DPDK suite.  This includes environment
-  variables, hugepages configuration, tool-chains and configuration
+  variables, hugepages configuration, tool-chains and configuration.
 - Insert vfio-pci kernel module using the command 'modprobe vfio-pci' if the
 - Insert vfio-pci kernel module using the command 'modprobe vfio-pci' if the
-  user wants to use VFIO framework
+  user wants to use VFIO framework.
 - Insert uio kernel module using the command 'modprobe uio' if the user wants
 - Insert uio kernel module using the command 'modprobe uio' if the user wants
-  to use UIO framework
+  to use UIO framework.
 - DPDK suite should be configured based on the user's decision to use VFIO or
 - DPDK suite should be configured based on the user's decision to use VFIO or
-  UIO framework
+  UIO framework.
 - If the vNIC device(s) to be used is bound to the kernel mode Ethernet driver
 - If the vNIC device(s) to be used is bound to the kernel mode Ethernet driver
-  use 'ifconfig' to bring the interface down. The dpdk-devbind.py tool can
+  use 'ip' to bring the interface down. The dpdk-devbind.py tool can
   then be used to unbind the device's bus id from the ENIC kernel mode driver.
 - Bind the intended vNIC to vfio-pci in case the user wants ENIC PMD to use
   VFIO framework using dpdk-devbind.py.
   then be used to unbind the device's bus id from the ENIC kernel mode driver.
 - Bind the intended vNIC to vfio-pci in case the user wants ENIC PMD to use
   VFIO framework using dpdk-devbind.py.
@@ -363,14 +580,15 @@ PMD.  Typically, the limit has to be raised to higher than 2GB.
 e.g., 2621440
 
 The compilation of any unused drivers can be disabled using the
 e.g., 2621440
 
 The compilation of any unused drivers can be disabled using the
-configuration file in config/ directory (e.g., config/common_linuxapp).
+configuration file in config/ directory (e.g., config/common_linux).
 This would help in bringing down the time taken for building the
 libraries and the initialization time of the application.
 
 Additional Reference
 --------------------
 
 This would help in bringing down the time taken for building the
 libraries and the initialization time of the application.
 
 Additional Reference
 --------------------
 
-- http://www.cisco.com/c/en/us/products/servers-unified-computing
+- https://www.cisco.com/c/en/us/products/servers-unified-computing/index.html
+- https://www.cisco.com/c/en/us/products/interfaces-modules/unified-computing-system-adapters/index.html
 
 Contact Information
 -------------------
 
 Contact Information
 -------------------
@@ -379,4 +597,4 @@ Any questions or bugs should be reported to DPDK community and to the ENIC PMD
 maintainers:
 
 - John Daley <johndale@cisco.com>
 maintainers:
 
 - John Daley <johndale@cisco.com>
-- Nelson Escobar <neescoba@cisco.com>
+- Hyong Youb Kim <hyonkim@cisco.com>