net/cnxk: add Rx queue setup and release
[dpdk.git] / doc / guides / nics / enic.rst
index 4e7629c..91bdcd0 100644 (file)
@@ -294,35 +294,31 @@ inner and outer packets can be IPv4 or IPv6.
 
   RSS hash calculation, therefore queue selection, is done on inner packets.
 
 
   RSS hash calculation, therefore queue selection, is done on inner packets.
 
-In order to enable overlay offload, the 'Enable VXLAN' box should be checked
+In order to enable overlay offload, enable VXLAN and/or Geneve on vNIC
 via CIMC or UCSM followed by a reboot of the server. When PMD successfully
 via CIMC or UCSM followed by a reboot of the server. When PMD successfully
-enables overlay offload, it prints the following message on the console.
+enables overlay offload, it prints one of the following messages on the console.
 
 .. code-block:: console
 
 
 .. code-block:: console
 
-    Overlay offload is enabled
+    Overlay offload is enabled (VxLAN)
+    Overlay offload is enabled (Geneve)
+    Overlay offload is enabled (VxLAN, Geneve)
 
 By default, PMD enables overlay offload if hardware supports it. To disable
 it, set ``devargs`` parameter ``disable-overlay=1``. For example::
 
     -a 12:00.0,disable-overlay=1
 
 
 By default, PMD enables overlay offload if hardware supports it. To disable
 it, set ``devargs`` parameter ``disable-overlay=1``. For example::
 
     -a 12:00.0,disable-overlay=1
 
-By default, the NIC uses 4789 as the VXLAN port. The user may change
-it through ``rte_eth_dev_udp_tunnel_port_{add,delete}``. However, as
-the current NIC has a single VXLAN port number, the user cannot
-configure multiple port numbers.
-
-Geneve headers with non-zero options are not supported by default. To
-use Geneve with options, update the VIC firmware to the latest version
-and then set ``devargs`` parameter ``geneve-opt=1``. When Geneve with
-options is enabled, flow API cannot be used as the features are
-currently mutually exclusive. When this feature is successfully
-enabled, PMD prints the following message.
-
-.. code-block:: console
-
-    Geneve with options is enabled
+By default, the NIC uses 4789 and 6081 as the VXLAN and Geneve ports,
+respectively. The user may change them through
+``rte_eth_dev_udp_tunnel_port_{add,delete}``. However, as the current
+NIC has a single VXLAN port number and a single Geneve port number,
+the user cannot configure multiple port numbers for each tunnel type.
 
 
+Geneve offload support has evolved over VIC models. On older models,
+Geneve offload and advanced filters are mutually exclusive.  This is
+enforced by UCSM and CIMC, which only allow one of the two features
+to be selected at one time. Newer VIC models do not have this restriction.
 
 Ingress VLAN Rewrite
 --------------------
 