+TC TX scheduling mode setting
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+There are 2 TX scheduling modes for TCs, round robin and strict priority mode.
+If a TC is set to strict priority mode, it can consume unlimited bandwidth.
+It means if APP has set the max bandwidth for that TC, it comes to no
+effect.
+It's suggested to set the strict priority mode for a TC that is latency
+sensitive but no consuming much bandwidth.
+
+VF performance is impacted by PCI extended tag setting
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+To reach maximum NIC performance in the VF the PCI extended tag must be
+enabled. The DPDK i40e PF driver will set this feature during initialization,
+but the kernel PF driver does not. So when running traffic on a VF which is
+managed by the kernel PF driver, a significant NIC performance downgrade has
+been observed (for 64 byte packets, there is about 25% line-rate downgrade for
+a 25GbE device and about 35% for a 40GbE device).
+
+For kernel version >= 4.11, the kernel's PCI driver will enable the extended
+tag if it detects that the device supports it. So by default, this is not an
+issue. For kernels <= 4.11 or when the PCI extended tag is disabled it can be
+enabled using the steps below.
+
+#. Get the current value of the PCI configure register::
+
+ setpci -s <XX:XX.X> a8.w
+
+#. Set bit 8::
+
+ value = value | 0x100
+
+#. Set the PCI configure register with new value::
+
+ setpci -s <XX:XX.X> a8.w=<value>
+
+Vlan strip of VF
+~~~~~~~~~~~~~~~~
+
+The VF vlan strip function is only supported in the i40e kernel driver >= 2.1.26.
+
+DCB function
+~~~~~~~~~~~~
+
+DCB works only when RSS is enabled.
+
+Global configuration warning
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+I40E PMD will set some global registers to enable some function or set some
+configure. Then when using different ports of the same NIC with Linux kernel
+and DPDK, the port with Linux kernel will be impacted by the port with DPDK.
+For example, register I40E_GL_SWT_L2TAGCTRL is used to control L2 tag, i40e
+PMD uses I40E_GL_SWT_L2TAGCTRL to set vlan TPID. If setting TPID in port A
+with DPDK, then the configuration will also impact port B in the NIC with
+kernel driver, which don't want to use the TPID.
+So PMD reports warning to clarify what is changed by writing global register.
+
+High Performance of Small Packets on 40GbE NIC
+----------------------------------------------
+
+As there might be firmware fixes for performance enhancement in latest version
+of firmware image, the firmware update might be needed for getting high performance.
+Check the Intel support website for the latest firmware updates.
+Users should consult the release notes specific to a DPDK release to identify
+the validated firmware version for a NIC using the i40e driver.
+
+Use 16 Bytes RX Descriptor Size
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+As i40e PMD supports both 16 and 32 bytes RX descriptor sizes, and 16 bytes size can provide helps to high performance of small packets.
+Configuration of ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` in config files can be changed to use 16 bytes size RX descriptors.
+
+Example of getting best performance with l3fwd example
+------------------------------------------------------
+
+The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with a
+server with Intel Xeon processors and Intel Ethernet CNA XL710.
+
+The example scenario is to get best performance with two Intel Ethernet CNA XL710 40GbE ports.
+See :numref:`figure_intel_perf_test_setup` for the performance test setup.
+
+.. _figure_intel_perf_test_setup:
+
+.. figure:: img/intel_perf_test_setup.*
+
+ Performance Test Setup
+
+
+1. Add two Intel Ethernet CNA XL710 to the platform, and use one port per card to get best performance.
+ The reason for using two NICs is to overcome a PCIe v3.0 limitation since it cannot provide 80GbE bandwidth
+ for two 40GbE ports, but two different PCIe v3.0 x8 slot can.
+ Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
+
+ 82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
+ 85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
+
+2. Connect the ports to the traffic generator. For high speed testing, it's best to use a hardware traffic generator.
+
+3. Check the PCI devices numa node (socket id) and get the cores number on the exact socket id.
+ In this case, ``82:00.0`` and ``85:00.0`` are both in socket 1, and the cores on socket 1 in the referenced platform
+ are 18-35 and 54-71.
+ Note: Don't use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical
+ cores from different cores (e.g core18 and core19).
+
+4. Bind these two ports to igb_uio.
+
+5. As to Intel Ethernet CNA XL710 40GbE port, we need at least two queue pairs to achieve best performance, then two queues per port
+ will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
+
+6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
+ Compile the ``l3fwd sample`` with the default lpm mode.
+
+7. The command line of running l3fwd would be something like the following::
+
+ ./l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \
+ -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
+
+ This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
+ core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
+
+8. Configure the traffic at a traffic generator.
+
+ * Start creating a stream on packet generator.
+
+ * Set the Ethernet II type to 0x0800.
+
+Tx bytes affected by the link status change
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+For firmware versions prior to 6.01 for X710 series and 3.33 for X722 series, the tx_bytes statistics data is affected by
+the link down event. Each time the link status changes to down, the tx_bytes decreases 110 bytes.