+ * Convert wrong color setting action to verbose error.
+ *
+ * @param[in] action
+ * Policy color action.
+ *
+ * @return
+ * Verbose meter color error type.
+ */
+static inline enum rte_mtr_error_type
+action2error(enum rte_mtr_policer_action action)
+{
+ switch (action) {
+ case MTR_POLICER_ACTION_COLOR_GREEN:
+ return RTE_MTR_ERROR_TYPE_POLICER_ACTION_GREEN;
+ case MTR_POLICER_ACTION_COLOR_YELLOW:
+ return RTE_MTR_ERROR_TYPE_POLICER_ACTION_YELLOW;
+ case MTR_POLICER_ACTION_COLOR_RED:
+ return RTE_MTR_ERROR_TYPE_POLICER_ACTION_RED;
+ default:
+ break;
+ }
+ return RTE_MTR_ERROR_TYPE_UNSPECIFIED;
+}
+
+/**
+ * Check meter validation.
+ *
+ * @param[in] priv
+ * Pointer to mlx5 private data structure.
+ * @param[in] meter_id
+ * Meter id.
+ * @param[in] params
+ * Pointer to rte meter parameters.
+ * @param[out] error
+ * Pointer to rte meter error structure.
+ *
+ * @return
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_validate(struct mlx5_priv *priv, uint32_t meter_id,
+ struct rte_mtr_params *params,
+ struct rte_mtr_error *error)
+{
+ static enum rte_mtr_policer_action
+ valid_recol_action[RTE_COLORS] = {
+ MTR_POLICER_ACTION_COLOR_GREEN,
+ MTR_POLICER_ACTION_COLOR_YELLOW,
+ MTR_POLICER_ACTION_COLOR_RED };
+ int i;
+
+ /* Meter params must not be NULL. */
+ if (params == NULL)
+ return -rte_mtr_error_set(error, EINVAL,
+ RTE_MTR_ERROR_TYPE_MTR_PARAMS,
+ NULL, "Meter object params null.");
+ /* Previous meter color is not supported. */
+ if (params->use_prev_mtr_color)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_MTR_PARAMS,
+ NULL,
+ "Previous meter color "
+ "not supported.");
+ /* Validate policer settings. */
+ for (i = 0; i < RTE_COLORS; i++)
+ if (params->action[i] != valid_recol_action[i] &&
+ params->action[i] != MTR_POLICER_ACTION_DROP)
+ return -rte_mtr_error_set
+ (error, ENOTSUP,
+ action2error(params->action[i]), NULL,
+ "Recolor action not supported.");
+ /* Validate meter id. */
+ if (mlx5_flow_meter_find(priv, meter_id))
+ return -rte_mtr_error_set(error, EEXIST,
+ RTE_MTR_ERROR_TYPE_MTR_ID, NULL,
+ "Meter object already exists.");
+ return 0;
+}
+
+/**
+ * Modify the flow meter action.
+ *
+ * @param[in] priv
+ * Pointer to mlx5 private data structure.
+ * @param[in] fm
+ * Pointer to flow meter to be modified.
+ * @param[in] srtcm
+ * Pointer to meter srtcm description parameter.
+ * @param[in] modify_bits
+ * The bit in srtcm to be updated.
+ * @param[in] active_state
+ * The state to be updated.
+ * @return
+ * 0 on success, o negative value otherwise.
+ */
+static int
+mlx5_flow_meter_action_modify(struct mlx5_priv *priv,
+ struct mlx5_flow_meter *fm,
+ const struct mlx5_flow_meter_srtcm_rfc2697_prm *srtcm,
+ uint64_t modify_bits, uint32_t active_state)
+{
+#ifdef HAVE_MLX5_DR_CREATE_ACTION_FLOW_METER
+ uint32_t in[MLX5_ST_SZ_DW(flow_meter_parameters)] = { 0 };
+ uint32_t *attr;
+ struct mlx5dv_dr_flow_meter_attr mod_attr = { 0 };
+ int ret;
+
+ /* Fill command parameters. */
+ mod_attr.reg_c_index = priv->mtr_color_reg - REG_C_0;
+ mod_attr.flow_meter_parameter = in;
+ mod_attr.flow_meter_parameter_sz = fm->mfts->fmp_size;
+ if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_ACTIVE)
+ mod_attr.active = !!active_state;
+ else
+ mod_attr.active = 0;
+ attr = in;
+ if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS) {
+ MLX5_SET(flow_meter_parameters,
+ attr, cbs_exponent, srtcm->cbs_exponent);
+ MLX5_SET(flow_meter_parameters,
+ attr, cbs_mantissa, srtcm->cbs_mantissa);
+ }
+ if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR) {
+ MLX5_SET(flow_meter_parameters,
+ attr, cir_exponent, srtcm->cir_exponent);
+ MLX5_SET(flow_meter_parameters,
+ attr, cir_mantissa, srtcm->cir_mantissa);
+ }
+ if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_EBS) {
+ MLX5_SET(flow_meter_parameters,
+ attr, ebs_exponent, srtcm->ebs_exponent);
+ MLX5_SET(flow_meter_parameters,
+ attr, ebs_mantissa, srtcm->ebs_mantissa);
+ }
+ /* Apply modifications to meter only if it was created. */
+ if (fm->mfts->meter_action) {
+ ret = mlx5_glue->dv_modify_flow_action_meter
+ (fm->mfts->meter_action, &mod_attr,
+ rte_cpu_to_be_64(modify_bits));
+ if (ret)
+ return ret;
+ }
+ /* Update succeedded modify meter parameters. */
+ if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_ACTIVE)
+ fm->active_state = !!active_state;
+ attr = fm->mfts->fmp;
+ if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS) {
+ MLX5_SET(flow_meter_parameters,
+ attr, cbs_exponent, srtcm->cbs_exponent);
+ MLX5_SET(flow_meter_parameters,
+ attr, cbs_mantissa, srtcm->cbs_mantissa);
+ }
+ if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR) {
+ MLX5_SET(flow_meter_parameters,
+ attr, cir_exponent, srtcm->cir_exponent);
+ MLX5_SET(flow_meter_parameters,
+ attr, cir_mantissa, srtcm->cir_mantissa);
+ }
+ if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_EBS) {
+ MLX5_SET(flow_meter_parameters,
+ attr, ebs_exponent, srtcm->ebs_exponent);
+ MLX5_SET(flow_meter_parameters,
+ attr, ebs_mantissa, srtcm->ebs_mantissa);
+ }
+
+ return 0;
+#else
+ (void)priv;
+ (void)fm;
+ (void)srtcm;
+ (void)modify_bits;
+ (void)active_state;
+ return -ENOTSUP;
+#endif
+}
+
+/**
+ * Create meter rules.
+ *
+ * @param[in] dev
+ * Pointer to Ethernet device.
+ * @param[in] meter_id
+ * Meter id.
+ * @param[in] params
+ * Pointer to rte meter parameters.
+ * @param[in] shared
+ * Meter shared with other flow or not.
+ * @param[out] error
+ * Pointer to rte meter error structure.
+ *
+ * @return
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_create(struct rte_eth_dev *dev, uint32_t meter_id,
+ struct rte_mtr_params *params, int shared,
+ struct rte_mtr_error *error)
+{
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct mlx5_flow_meters *fms = &priv->flow_meters;
+ struct mlx5_flow_meter_profile *fmp;
+ struct mlx5_flow_meter *fm;
+ const struct rte_flow_attr attr = {
+ .ingress = 1,
+ .egress = 1,
+ .transfer = priv->config.dv_esw_en ? 1 : 0,
+ };
+ int ret;
+ unsigned int i;
+
+ if (!priv->mtr_en)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Meter is not support");
+ /* Validate the parameters. */
+ ret = mlx5_flow_meter_validate(priv, meter_id, params, error);
+ if (ret)
+ return ret;
+ /* Meter profile must exist. */
+ fmp = mlx5_flow_meter_profile_find(priv, params->meter_profile_id);
+ if (fmp == NULL)
+ return -rte_mtr_error_set(error, ENOENT,
+ RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
+ NULL, "Meter profile id not valid.");
+ /* Allocate the flow meter memory. */
+ fm = rte_calloc(__func__, 1,
+ sizeof(struct mlx5_flow_meter), RTE_CACHE_LINE_SIZE);
+ if (fm == NULL)
+ return -rte_mtr_error_set(error, ENOMEM,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Memory alloc failed for meter.");
+ /* Fill the flow meter parameters. */
+ fm->meter_id = meter_id;
+ fm->profile = fmp;
+ fm->params = *params;
+ /* Alloc policer counters. */
+ for (i = 0; i < RTE_DIM(fm->policer_stats.cnt); i++) {
+ fm->policer_stats.cnt[i] = mlx5_counter_alloc(dev);
+ if (!fm->policer_stats.cnt[i])
+ goto error;
+ }
+ fm->mfts = mlx5_flow_create_mtr_tbls(dev, fm);
+ if (!fm->mfts)
+ goto error;
+ ret = mlx5_flow_create_policer_rules(dev, fm, &attr);
+ if (ret)
+ goto error;
+ /* Add to the flow meter list. */
+ TAILQ_INSERT_TAIL(fms, fm, next);
+ fm->active_state = 1; /* Config meter starts as active. */
+ fm->shared = !!shared;
+ fm->policer_stats.stats_mask = params->stats_mask;
+ fm->profile->ref_cnt++;
+ return 0;
+error:
+ mlx5_flow_destroy_policer_rules(dev, fm, &attr);
+ mlx5_flow_destroy_mtr_tbls(dev, fm->mfts);
+ /* Free policer counters. */
+ for (i = 0; i < RTE_DIM(fm->policer_stats.cnt); i++)
+ if (fm->policer_stats.cnt[i])
+ mlx5_counter_free(dev, fm->policer_stats.cnt[i]);
+ rte_free(fm);
+ return -rte_mtr_error_set(error, -ret,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED,
+ NULL, "Failed to create devx meter.");
+}
+
+/**
+ * Destroy meter rules.
+ *
+ * @param[in] dev
+ * Pointer to Ethernet device.
+ * @param[in] meter_id
+ * Meter id.
+ * @param[out] error
+ * Pointer to rte meter error structure.
+ *
+ * @return
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_destroy(struct rte_eth_dev *dev, uint32_t meter_id,
+ struct rte_mtr_error *error)
+{
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct mlx5_flow_meters *fms = &priv->flow_meters;
+ struct mlx5_flow_meter_profile *fmp;
+ struct mlx5_flow_meter *fm;
+ const struct rte_flow_attr attr = {
+ .ingress = 1,
+ .egress = 1,
+ .transfer = priv->config.dv_esw_en ? 1 : 0,
+ };
+ unsigned int i;
+
+ if (!priv->mtr_en)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Meter is not support");
+ /* Meter object must exist. */
+ fm = mlx5_flow_meter_find(priv, meter_id);
+ if (fm == NULL)
+ return -rte_mtr_error_set(error, ENOENT,
+ RTE_MTR_ERROR_TYPE_MTR_ID,
+ NULL, "Meter object id not valid.");
+ /* Meter object must not have any owner. */
+ if (fm->ref_cnt > 0)
+ return -rte_mtr_error_set(error, EBUSY,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED,
+ NULL, "Meter object is being used.");
+ /* Get the meter profile. */
+ fmp = fm->profile;
+ RTE_ASSERT(fmp);
+ /* Update dependencies. */
+ fmp->ref_cnt--;
+ /* Remove from the flow meter list. */
+ TAILQ_REMOVE(fms, fm, next);
+ /* Free policer counters. */
+ for (i = 0; i < RTE_DIM(fm->policer_stats.cnt); i++)
+ if (fm->policer_stats.cnt[i])
+ mlx5_counter_free(dev, fm->policer_stats.cnt[i]);
+ /* Free meter flow table */
+ mlx5_flow_destroy_policer_rules(dev, fm, &attr);
+ mlx5_flow_destroy_mtr_tbls(dev, fm->mfts);
+ rte_free(fm);
+ return 0;
+}
+
+/**
+ * Modify meter state.
+ *
+ * @param[in] priv
+ * Pointer to mlx5 private data structure.
+ * @param[in] fm
+ * Pointer to flow meter.
+ * @param[in] new_state
+ * New state to update.
+ * @param[out] error
+ * Pointer to rte meter error structure.
+ *
+ * @return
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_modify_state(struct mlx5_priv *priv,
+ struct mlx5_flow_meter *fm,
+ uint32_t new_state,
+ struct rte_mtr_error *error)
+{
+ static const struct mlx5_flow_meter_srtcm_rfc2697_prm srtcm = {
+ .cbs_exponent = 20,
+ .cbs_mantissa = 191,
+ .cir_exponent = 0,
+ .cir_mantissa = 200,
+ .ebs_exponent = 0,
+ .ebs_mantissa = 0,
+ };
+ uint64_t modify_bits = MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS |
+ MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR;
+ int ret;
+
+ if (new_state == MLX5_FLOW_METER_DISABLE)
+ ret = mlx5_flow_meter_action_modify(priv, fm, &srtcm,
+ modify_bits, 0);
+ else
+ ret = mlx5_flow_meter_action_modify(priv, fm,
+ &fm->profile->srtcm_prm,
+ modify_bits, 0);
+ if (ret)
+ return -rte_mtr_error_set(error, -ret,
+ RTE_MTR_ERROR_TYPE_MTR_PARAMS,
+ NULL,
+ new_state ?
+ "Failed to enable meter." :
+ "Failed to disable meter.");
+ return 0;
+}
+
+/**
+ * Callback to enable flow meter.
+ *
+ * @param[in] dev
+ * Pointer to Ethernet device.
+ * @param[in] meter_id
+ * Meter id.
+ * @param[out] error
+ * Pointer to rte meter error structure.
+ *
+ * @return
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_enable(struct rte_eth_dev *dev,
+ uint32_t meter_id,
+ struct rte_mtr_error *error)
+{
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct mlx5_flow_meter *fm;
+ int ret;
+
+ if (!priv->mtr_en)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Meter is not support");
+ /* Meter object must exist. */
+ fm = mlx5_flow_meter_find(priv, meter_id);
+ if (fm == NULL)
+ return -rte_mtr_error_set(error, ENOENT,
+ RTE_MTR_ERROR_TYPE_MTR_ID,
+ NULL, "Meter not found.");
+ if (fm->active_state == MLX5_FLOW_METER_ENABLE)
+ return 0;
+ ret = mlx5_flow_meter_modify_state(priv, fm, MLX5_FLOW_METER_ENABLE,
+ error);
+ if (!ret)
+ fm->active_state = MLX5_FLOW_METER_ENABLE;
+ return ret;
+}
+
+/**
+ * Callback to disable flow meter.
+ *
+ * @param[in] dev
+ * Pointer to Ethernet device.
+ * @param[in] meter_id
+ * Meter id.
+ * @param[out] error
+ * Pointer to rte meter error structure.
+ *
+ * @return
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_disable(struct rte_eth_dev *dev,
+ uint32_t meter_id,
+ struct rte_mtr_error *error)
+{
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct mlx5_flow_meter *fm;
+ int ret;
+
+ if (!priv->mtr_en)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Meter is not support");
+ /* Meter object must exist. */
+ fm = mlx5_flow_meter_find(priv, meter_id);
+ if (fm == NULL)
+ return -rte_mtr_error_set(error, ENOENT,
+ RTE_MTR_ERROR_TYPE_MTR_ID,
+ NULL, "Meter not found.");
+ if (fm->active_state == MLX5_FLOW_METER_DISABLE)
+ return 0;
+ ret = mlx5_flow_meter_modify_state(priv, fm, MLX5_FLOW_METER_DISABLE,
+ error);
+ if (!ret)
+ fm->active_state = MLX5_FLOW_METER_DISABLE;
+ return ret;
+}
+
+/**
+ * Callback to update meter profile.
+ *
+ * @param[in] dev
+ * Pointer to Ethernet device.
+ * @param[in] meter_id
+ * Meter id.
+ * @param[in] meter_profile_id
+ * To be updated meter profile id.
+ * @param[out] error
+ * Pointer to rte meter error structure.
+ *
+ * @return
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_profile_update(struct rte_eth_dev *dev,
+ uint32_t meter_id,
+ uint32_t meter_profile_id,
+ struct rte_mtr_error *error)
+{
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct mlx5_flow_meter_profile *fmp;
+ struct mlx5_flow_meter_profile *old_fmp;
+ struct mlx5_flow_meter *fm;
+ uint64_t modify_bits = MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS |
+ MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR;
+ int ret;
+
+ if (!priv->mtr_en)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Meter is not support");
+ /* Meter profile must exist. */
+ fmp = mlx5_flow_meter_profile_find(priv, meter_profile_id);
+ if (fmp == NULL)
+ return -rte_mtr_error_set(error, ENOENT,
+ RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
+ NULL, "Meter profile not found.");
+ /* Meter object must exist. */
+ fm = mlx5_flow_meter_find(priv, meter_id);
+ if (fm == NULL)
+ return -rte_mtr_error_set(error, ENOENT,
+ RTE_MTR_ERROR_TYPE_MTR_ID,
+ NULL, "Meter not found.");
+ /* MTR object already set to meter profile id. */
+ old_fmp = fm->profile;
+ if (fmp == old_fmp)
+ return 0;
+ /* Update the profile. */
+ fm->profile = fmp;
+ /* Update meter params in HW (if not disabled). */
+ if (fm->active_state == MLX5_FLOW_METER_DISABLE)
+ return 0;
+ ret = mlx5_flow_meter_action_modify(priv, fm, &fm->profile->srtcm_prm,
+ modify_bits, fm->active_state);
+ if (ret) {
+ fm->profile = old_fmp;
+ return -rte_mtr_error_set(error, -ret,
+ RTE_MTR_ERROR_TYPE_MTR_PARAMS,
+ NULL, "Failed to update meter"
+ " parmeters in hardware.");
+ }
+ old_fmp->ref_cnt--;
+ fmp->ref_cnt++;
+ return 0;
+}
+
+/**
+ * Callback to update meter stats mask.
+ *
+ * @param[in] dev
+ * Pointer to Ethernet device.
+ * @param[in] meter_id
+ * Meter id.
+ * @param[in] stats_mask
+ * To be updated stats_mask.
+ * @param[out] error
+ * Pointer to rte meter error structure.
+ *
+ * @return
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_stats_update(struct rte_eth_dev *dev,
+ uint32_t meter_id,
+ uint64_t stats_mask,
+ struct rte_mtr_error *error)
+{
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct mlx5_flow_meter *fm;
+
+ if (!priv->mtr_en)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Meter is not support");
+ /* Meter object must exist. */
+ fm = mlx5_flow_meter_find(priv, meter_id);
+ if (fm == NULL)
+ return -rte_mtr_error_set(error, ENOENT,
+ RTE_MTR_ERROR_TYPE_MTR_ID,
+ NULL, "Meter object id not valid.");
+ fm->policer_stats.stats_mask = stats_mask;
+ return 0;
+}
+
+/**
+ * Callback to read meter statistics.
+ *
+ * @param[in] dev
+ * Pointer to Ethernet device.
+ * @param[in] meter_id
+ * Meter id.
+ * @param[out] stats
+ * Pointer to store the statistics.
+ * @param[out] stats_mask
+ * Pointer to store the stats_mask.
+ * @param[in] clear
+ * Statistic to be cleared after read or not.
+ * @param[out] error
+ * Pointer to rte meter error structure.
+ *
+ * @return
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_stats_read(struct rte_eth_dev *dev,
+ uint32_t meter_id,
+ struct rte_mtr_stats *stats,
+ uint64_t *stats_mask,
+ int clear,
+ struct rte_mtr_error *error)
+{
+ static uint64_t meter2mask[RTE_MTR_DROPPED + 1] = {
+ RTE_MTR_STATS_N_PKTS_GREEN | RTE_MTR_STATS_N_BYTES_GREEN,
+ RTE_MTR_STATS_N_PKTS_YELLOW | RTE_MTR_STATS_N_BYTES_YELLOW,
+ RTE_MTR_STATS_N_PKTS_RED | RTE_MTR_STATS_N_BYTES_RED,
+ RTE_MTR_STATS_N_PKTS_DROPPED | RTE_MTR_STATS_N_BYTES_DROPPED
+ };
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct mlx5_flow_meter *fm;
+ struct mlx5_flow_policer_stats *ps;
+ uint64_t pkts_dropped = 0;
+ uint64_t bytes_dropped = 0;
+ uint64_t pkts;
+ uint64_t bytes;
+ int i;
+ int ret = 0;
+
+ if (!priv->mtr_en)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Meter is not support");
+ /* Meter object must exist. */
+ fm = mlx5_flow_meter_find(priv, meter_id);
+ if (fm == NULL)
+ return -rte_mtr_error_set(error, ENOENT,
+ RTE_MTR_ERROR_TYPE_MTR_ID,
+ NULL, "Meter object id not valid.");
+ ps = &fm->policer_stats;
+ *stats_mask = ps->stats_mask;
+ for (i = 0; i < RTE_MTR_DROPPED; i++) {
+ if (*stats_mask & meter2mask[i]) {
+ ret = mlx5_counter_query(dev, ps->cnt[i], clear, &pkts,
+ &bytes);
+ if (ret)
+ goto error;
+ if (fm->params.action[i] == MTR_POLICER_ACTION_DROP) {
+ pkts_dropped += pkts;
+ bytes_dropped += bytes;
+ }
+ /* If need to read the packets, set it. */
+ if ((1 << i) & (*stats_mask & meter2mask[i]))
+ stats->n_pkts[i] = pkts;
+ /* If need to read the bytes, set it. */
+ if ((1 << (RTE_MTR_DROPPED + 1 + i)) &
+ (*stats_mask & meter2mask[i]))
+ stats->n_bytes[i] = bytes;
+ }
+ }
+ /* Dropped packets/bytes are treated differently. */
+ if (*stats_mask & meter2mask[i]) {
+ ret = mlx5_counter_query(dev, ps->cnt[i], clear, &pkts,
+ &bytes);
+ if (ret)
+ goto error;
+ pkts += pkts_dropped;
+ bytes += bytes_dropped;
+ /* If need to read the packets, set it. */
+ if ((*stats_mask & meter2mask[i]) &
+ RTE_MTR_STATS_N_PKTS_DROPPED)
+ stats->n_pkts_dropped = pkts;
+ /* If need to read the bytes, set it. */
+ if ((*stats_mask & meter2mask[i]) &
+ RTE_MTR_STATS_N_BYTES_DROPPED)
+ stats->n_bytes_dropped = bytes;
+ }
+ return 0;
+error:
+ return -rte_mtr_error_set(error, ret, RTE_MTR_ERROR_TYPE_STATS, NULL,
+ "Failed to read policer counters.");
+}
+