+ * Callback to enable flow meter.
+ *
+ * @param[in] dev
+ * Pointer to Ethernet device.
+ * @param[in] meter_id
+ * Meter id.
+ * @param[out] error
+ * Pointer to rte meter error structure.
+ *
+ * @return
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_enable(struct rte_eth_dev *dev,
+ uint32_t meter_id,
+ struct rte_mtr_error *error)
+{
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct mlx5_flow_meter *fm;
+ int ret;
+
+ if (!priv->mtr_en)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Meter is not supported");
+ /* Meter object must exist. */
+ fm = mlx5_flow_meter_find(priv, meter_id);
+ if (fm == NULL)
+ return -rte_mtr_error_set(error, ENOENT,
+ RTE_MTR_ERROR_TYPE_MTR_ID,
+ NULL, "Meter not found.");
+ if (fm->active_state == MLX5_FLOW_METER_ENABLE)
+ return 0;
+ ret = mlx5_flow_meter_modify_state(priv, fm, MLX5_FLOW_METER_ENABLE,
+ error);
+ if (!ret)
+ fm->active_state = MLX5_FLOW_METER_ENABLE;
+ return ret;
+}
+
+/**
+ * Callback to disable flow meter.
+ *
+ * @param[in] dev
+ * Pointer to Ethernet device.
+ * @param[in] meter_id
+ * Meter id.
+ * @param[out] error
+ * Pointer to rte meter error structure.
+ *
+ * @return
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_disable(struct rte_eth_dev *dev,
+ uint32_t meter_id,
+ struct rte_mtr_error *error)
+{
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct mlx5_flow_meter *fm;
+ int ret;
+
+ if (!priv->mtr_en)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Meter is not supported");
+ /* Meter object must exist. */
+ fm = mlx5_flow_meter_find(priv, meter_id);
+ if (fm == NULL)
+ return -rte_mtr_error_set(error, ENOENT,
+ RTE_MTR_ERROR_TYPE_MTR_ID,
+ NULL, "Meter not found.");
+ if (fm->active_state == MLX5_FLOW_METER_DISABLE)
+ return 0;
+ ret = mlx5_flow_meter_modify_state(priv, fm, MLX5_FLOW_METER_DISABLE,
+ error);
+ if (!ret)
+ fm->active_state = MLX5_FLOW_METER_DISABLE;
+ return ret;
+}
+
+/**
+ * Callback to update meter profile.
+ *
+ * @param[in] dev
+ * Pointer to Ethernet device.
+ * @param[in] meter_id
+ * Meter id.
+ * @param[in] meter_profile_id
+ * To be updated meter profile id.
+ * @param[out] error
+ * Pointer to rte meter error structure.
+ *
+ * @return
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_profile_update(struct rte_eth_dev *dev,
+ uint32_t meter_id,
+ uint32_t meter_profile_id,
+ struct rte_mtr_error *error)
+{
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct mlx5_flow_meter_profile *fmp;
+ struct mlx5_flow_meter_profile *old_fmp;
+ struct mlx5_flow_meter *fm;
+ uint64_t modify_bits = MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS |
+ MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR;
+ int ret;
+
+ if (!priv->mtr_en)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Meter is not supported");
+ /* Meter profile must exist. */
+ fmp = mlx5_flow_meter_profile_find(priv, meter_profile_id);
+ if (fmp == NULL)
+ return -rte_mtr_error_set(error, ENOENT,
+ RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
+ NULL, "Meter profile not found.");
+ /* Meter object must exist. */
+ fm = mlx5_flow_meter_find(priv, meter_id);
+ if (fm == NULL)
+ return -rte_mtr_error_set(error, ENOENT,
+ RTE_MTR_ERROR_TYPE_MTR_ID,
+ NULL, "Meter not found.");
+ /* MTR object already set to meter profile id. */
+ old_fmp = fm->profile;
+ if (fmp == old_fmp)
+ return 0;
+ /* Update the profile. */
+ fm->profile = fmp;
+ /* Update meter params in HW (if not disabled). */
+ if (fm->active_state == MLX5_FLOW_METER_DISABLE)
+ return 0;
+ ret = mlx5_flow_meter_action_modify(priv, fm, &fm->profile->srtcm_prm,
+ modify_bits, fm->active_state);
+ if (ret) {
+ fm->profile = old_fmp;
+ return -rte_mtr_error_set(error, -ret,
+ RTE_MTR_ERROR_TYPE_MTR_PARAMS,
+ NULL, "Failed to update meter"
+ " parmeters in hardware.");
+ }
+ old_fmp->ref_cnt--;
+ fmp->ref_cnt++;
+ return 0;
+}
+
+/**
+ * Callback to update meter stats mask.
+ *
+ * @param[in] dev
+ * Pointer to Ethernet device.
+ * @param[in] meter_id
+ * Meter id.
+ * @param[in] stats_mask
+ * To be updated stats_mask.
+ * @param[out] error
+ * Pointer to rte meter error structure.
+ *
+ * @return
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_stats_update(struct rte_eth_dev *dev,
+ uint32_t meter_id,
+ uint64_t stats_mask,
+ struct rte_mtr_error *error)
+{
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct mlx5_flow_meter *fm;
+
+ if (!priv->mtr_en)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Meter is not supported");
+ /* Meter object must exist. */
+ fm = mlx5_flow_meter_find(priv, meter_id);
+ if (fm == NULL)
+ return -rte_mtr_error_set(error, ENOENT,
+ RTE_MTR_ERROR_TYPE_MTR_ID,
+ NULL, "Meter object id not valid.");
+ fm->policer_stats.stats_mask = stats_mask;
+ return 0;
+}
+
+/**
+ * Callback to read meter statistics.
+ *
+ * @param[in] dev
+ * Pointer to Ethernet device.
+ * @param[in] meter_id
+ * Meter id.
+ * @param[out] stats
+ * Pointer to store the statistics.
+ * @param[out] stats_mask
+ * Pointer to store the stats_mask.
+ * @param[in] clear
+ * Statistic to be cleared after read or not.
+ * @param[out] error
+ * Pointer to rte meter error structure.
+ *
+ * @return
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_stats_read(struct rte_eth_dev *dev,
+ uint32_t meter_id,
+ struct rte_mtr_stats *stats,
+ uint64_t *stats_mask,
+ int clear,
+ struct rte_mtr_error *error)
+{
+ static uint64_t meter2mask[RTE_MTR_DROPPED + 1] = {
+ RTE_MTR_STATS_N_PKTS_GREEN | RTE_MTR_STATS_N_BYTES_GREEN,
+ RTE_MTR_STATS_N_PKTS_YELLOW | RTE_MTR_STATS_N_BYTES_YELLOW,
+ RTE_MTR_STATS_N_PKTS_RED | RTE_MTR_STATS_N_BYTES_RED,
+ RTE_MTR_STATS_N_PKTS_DROPPED | RTE_MTR_STATS_N_BYTES_DROPPED
+ };
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct mlx5_flow_meter *fm;
+ struct mlx5_flow_policer_stats *ps;
+ uint64_t pkts_dropped = 0;
+ uint64_t bytes_dropped = 0;
+ uint64_t pkts;
+ uint64_t bytes;
+ int i;
+ int ret = 0;
+
+ if (!priv->mtr_en)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Meter is not supported");
+ /* Meter object must exist. */
+ fm = mlx5_flow_meter_find(priv, meter_id);
+ if (fm == NULL)
+ return -rte_mtr_error_set(error, ENOENT,
+ RTE_MTR_ERROR_TYPE_MTR_ID,
+ NULL, "Meter object id not valid.");
+ ps = &fm->policer_stats;
+ *stats_mask = ps->stats_mask;
+ for (i = 0; i < RTE_MTR_DROPPED; i++) {
+ if (*stats_mask & meter2mask[i]) {
+ ret = mlx5_counter_query(dev, ps->cnt[i], clear, &pkts,
+ &bytes);
+ if (ret)
+ goto error;
+ if (fm->action[i] == MTR_POLICER_ACTION_DROP) {
+ pkts_dropped += pkts;
+ bytes_dropped += bytes;
+ }
+ /* If need to read the packets, set it. */
+ if ((1 << i) & (*stats_mask & meter2mask[i]))
+ stats->n_pkts[i] = pkts;
+ /* If need to read the bytes, set it. */
+ if ((1 << (RTE_MTR_DROPPED + 1 + i)) &
+ (*stats_mask & meter2mask[i]))
+ stats->n_bytes[i] = bytes;
+ }
+ }
+ /* Dropped packets/bytes are treated differently. */
+ if (*stats_mask & meter2mask[i]) {
+ ret = mlx5_counter_query(dev, ps->cnt[i], clear, &pkts,
+ &bytes);
+ if (ret)
+ goto error;
+ pkts += pkts_dropped;
+ bytes += bytes_dropped;
+ /* If need to read the packets, set it. */
+ if ((*stats_mask & meter2mask[i]) &
+ RTE_MTR_STATS_N_PKTS_DROPPED)
+ stats->n_pkts_dropped = pkts;
+ /* If need to read the bytes, set it. */
+ if ((*stats_mask & meter2mask[i]) &
+ RTE_MTR_STATS_N_BYTES_DROPPED)
+ stats->n_bytes_dropped = bytes;
+ }
+ return 0;
+error:
+ return -rte_mtr_error_set(error, ret, RTE_MTR_ERROR_TYPE_STATS, NULL,
+ "Failed to read policer counters.");
+}
+