+ * txgbe_fdir_check_cmd_complete - poll to check whether FDIRPICMD is complete
+ * @hw: pointer to hardware structure
+ * @fdircmd: current value of FDIRCMD register
+ */
+static s32 txgbe_fdir_check_cmd_complete(struct txgbe_hw *hw, u32 *fdircmd)
+{
+ int i;
+
+ for (i = 0; i < TXGBE_FDIRCMD_CMD_POLL; i++) {
+ *fdircmd = rd32(hw, TXGBE_FDIRPICMD);
+ if (!(*fdircmd & TXGBE_FDIRPICMD_OP_MASK))
+ return 0;
+ usec_delay(10);
+ }
+
+ return TXGBE_ERR_FDIR_CMD_INCOMPLETE;
+}
+
+/**
+ * txgbe_reinit_fdir_tables - Reinitialize Flow Director tables.
+ * @hw: pointer to hardware structure
+ **/
+s32 txgbe_reinit_fdir_tables(struct txgbe_hw *hw)
+{
+ s32 err;
+ int i;
+ u32 fdirctrl = rd32(hw, TXGBE_FDIRCTL);
+ u32 fdircmd;
+ fdirctrl &= ~TXGBE_FDIRCTL_INITDONE;
+
+ DEBUGFUNC("txgbe_reinit_fdir_tables");
+
+ /*
+ * Before starting reinitialization process,
+ * FDIRPICMD.OP must be zero.
+ */
+ err = txgbe_fdir_check_cmd_complete(hw, &fdircmd);
+ if (err) {
+ DEBUGOUT("Flow Director previous command did not complete, aborting table re-initialization.\n");
+ return err;
+ }
+
+ wr32(hw, TXGBE_FDIRFREE, 0);
+ txgbe_flush(hw);
+ /*
+ * adapters flow director init flow cannot be restarted,
+ * Workaround silicon errata by performing the following steps
+ * before re-writing the FDIRCTL control register with the same value.
+ * - write 1 to bit 8 of FDIRPICMD register &
+ * - write 0 to bit 8 of FDIRPICMD register
+ */
+ wr32m(hw, TXGBE_FDIRPICMD, TXGBE_FDIRPICMD_CLR, TXGBE_FDIRPICMD_CLR);
+ txgbe_flush(hw);
+ wr32m(hw, TXGBE_FDIRPICMD, TXGBE_FDIRPICMD_CLR, 0);
+ txgbe_flush(hw);
+ /*
+ * Clear FDIR Hash register to clear any leftover hashes
+ * waiting to be programmed.
+ */
+ wr32(hw, TXGBE_FDIRPIHASH, 0x00);
+ txgbe_flush(hw);
+
+ wr32(hw, TXGBE_FDIRCTL, fdirctrl);
+ txgbe_flush(hw);
+
+ /* Poll init-done after we write FDIRCTL register */
+ for (i = 0; i < TXGBE_FDIR_INIT_DONE_POLL; i++) {
+ if (rd32m(hw, TXGBE_FDIRCTL, TXGBE_FDIRCTL_INITDONE))
+ break;
+ msec_delay(1);
+ }
+ if (i >= TXGBE_FDIR_INIT_DONE_POLL) {
+ DEBUGOUT("Flow Director Signature poll time exceeded!\n");
+ return TXGBE_ERR_FDIR_REINIT_FAILED;
+ }
+
+ /* Clear FDIR statistics registers (read to clear) */
+ rd32(hw, TXGBE_FDIRUSED);
+ rd32(hw, TXGBE_FDIRFAIL);
+ rd32(hw, TXGBE_FDIRMATCH);
+ rd32(hw, TXGBE_FDIRMISS);
+ rd32(hw, TXGBE_FDIRLEN);
+
+ return 0;
+}
+