net/cxgbe: add devargs to control filtermode and filtermask
[dpdk.git] / doc / guides / nics / cxgbe.rst
index 54a019d..54a4c13 100644 (file)
-..  BSD LICENSE
-    Copyright 2015 Chelsio Communications.
-    All rights reserved.
-
-    Redistribution and use in source and binary forms, with or without
-    modification, are permitted provided that the following conditions
-    are met:
-
-    * Redistributions of source code must retain the above copyright
-    notice, this list of conditions and the following disclaimer.
-    * Redistributions in binary form must reproduce the above copyright
-    notice, this list of conditions and the following disclaimer in
-    the documentation and/or other materials provided with the
-    distribution.
-    * Neither the name of Chelsio Communications nor the names of its
-    contributors may be used to endorse or promote products derived
-    from this software without specific prior written permission.
-
-    THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
-    "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
-    LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
-    A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
-    OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
-    SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
-    LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
-    DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
-    THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
-    (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
-    OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
+.. SPDX-License-Identifier: BSD-3-Clause
+   Copyright(c) 2014-2018 Chelsio Communications.
+   All rights reserved.
 
 CXGBE Poll Mode Driver
 ======================
 
 The CXGBE PMD (**librte_pmd_cxgbe**) provides poll mode driver support
-for **Chelsio T5** 10/40 Gbps family of adapters.
+for **Chelsio Terminator** 10/25/40/100 Gbps family of adapters. CXGBE PMD
+has support for the latest Linux and FreeBSD operating systems.
 
-More information can be found at `Chelsio Communications
+CXGBEVF PMD provides poll mode driver support for SR-IOV Virtual functions
+and has support for the latest Linux operating systems.
+
+More information can be found at `Chelsio Communications Official Website
 <http://www.chelsio.com>`_.
 
 Features
 --------
 
-CXGBE PMD has the support for:
+CXGBE and CXGBEVF PMD has support for:
 
-- Multiple queues for TX and RX.
-- Receiver Side Steering (RSS).
-- VLAN filtering.
-- Checksum offload.
-- Promiscuous mode.
-- All multicast mode.
-- Port hardware statistics.
+- Multiple queues for TX and RX
+- Receiver Side Steering (RSS)
+  Receiver Side Steering (RSS) on IPv4, IPv6, IPv4-TCP/UDP, IPv6-TCP/UDP.
+  For 4-tuple, enabling 'RSS on TCP' and 'RSS on TCP + UDP' is supported.
+- VLAN filtering
+- Checksum offload
+- Promiscuous mode
+- All multicast mode
+- Port hardware statistics
+- Jumbo frames
+- Flow API - Support for both Wildcard (LE-TCAM) and Exact (HASH) match filters.
 
 Limitations
 -----------
 
-The Chelsio T5 devices provide two/four ports but expose a single PCI bus
-address, thus, librte_pmd_cxgbe registers itself as a
-PCI driver that allocates one Ethernet device per detected port.
+The Chelsio Terminator series of devices provide two/four ports but
+expose a single PCI bus address, thus, librte_pmd_cxgbe registers
+itself as a PCI driver that allocates one Ethernet device per detected
+port.
+
+For this reason, one cannot whitelist/blacklist a single port without
+whitelisting/blacklisting the other ports on the same device.
+
+.. _t5-nics:
+
+Supported Chelsio T5 NICs
+-------------------------
+
+- 1G NICs: T502-BT
+- 10G NICs: T520-BT, T520-CR, T520-LL-CR, T520-SO-CR, T540-CR
+- 40G NICs: T580-CR, T580-LP-CR, T580-SO-CR
+- Other T5 NICs: T522-CR
+
+.. _t6-nics:
+
+Supported Chelsio T6 NICs
+-------------------------
+
+- 25G NICs: T6425-CR, T6225-CR, T6225-LL-CR, T6225-SO-CR
+- 100G NICs: T62100-CR, T62100-LP-CR, T62100-SO-CR
 
-For this reason, one cannot white/blacklist a single port without also
-white/blacklisting the others on the same device.
+Supported SR-IOV Chelsio NICs
+-----------------------------
 
-Configuration
+SR-IOV virtual functions are supported on all the Chelsio NICs listed
+in :ref:`t5-nics` and :ref:`t6-nics`.
+
+Prerequisites
 -------------
 
-Compiling CXGBE PMD
+- Requires firmware version **1.24.11.0** and higher. Visit
+  `Chelsio Download Center <http://service.chelsio.com>`_ to get latest firmware
+  bundled with the latest Chelsio Unified Wire package.
+
+  For Linux, installing and loading the latest cxgb4 kernel driver from the
+  Chelsio Unified Wire package should get you the latest firmware. More
+  information can be obtained from the User Guide that is bundled with the
+  Chelsio Unified Wire package.
+
+  For FreeBSD, the latest firmware obtained from the Chelsio Unified Wire
+  package must be manually flashed via cxgbetool available in FreeBSD source
+  repository.
+
+  Instructions on how to manually flash the firmware are given in section
+  :ref:`linux-installation` for Linux and section :ref:`freebsd-installation`
+  for FreeBSD.
+
+Pre-Installation Configuration
+------------------------------
+
+Config File Options
 ~~~~~~~~~~~~~~~~~~~
 
-These options can be modified in the ``.config`` file.
+The following options can be modified in the ``.config`` file. Please note that
+enabling debugging options may affect system performance.
 
 - ``CONFIG_RTE_LIBRTE_CXGBE_PMD`` (default **y**)
 
   Toggle compilation of librte_pmd_cxgbe driver.
 
-- ``CONFIG_RTE_LIBRTE_CXGBE_DEBUG`` (default **n**)
+  .. note::
+
+     This controls compilation of both CXGBE and CXGBEVF PMD.
+
+Runtime Options
+~~~~~~~~~~~~~~~
+
+The following ``devargs`` options can be enabled at runtime. They must
+be passed as part of EAL arguments. For example,
+
+.. code-block:: console
+
+   testpmd -w 02:00.4,keep_ovlan=1 -- -i
+
+Common Runtime Options
+^^^^^^^^^^^^^^^^^^^^^^
+
+- ``keep_ovlan`` (default **0**)
+
+  Toggle behavior to keep/strip outer VLAN in Q-in-Q packets. If
+  enabled, the outer VLAN tag is preserved in Q-in-Q packets. Otherwise,
+  the outer VLAN tag is stripped in Q-in-Q packets.
+
+- ``tx_mode_latency`` (default **0**)
+
+  When set to 1, Tx doesn't wait for max number of packets to get
+  coalesced and sends the packets immediately at the end of the
+  current Tx burst. When set to 0, Tx waits across multiple Tx bursts
+  until the max number of packets have been coalesced. In this case,
+  Tx only sends the coalesced packets to hardware once the max
+  coalesce limit has been reached.
+
+CXGBE VF Only Runtime Options
+^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
+
+- ``force_link_up`` (default **0**)
+
+  When set to 1, CXGBEVF PMD always forces link as up for all VFs on
+  underlying Chelsio NICs. This enables multiple VFs on the same NIC
+  to send traffic to each other even when the physical link is down.
+
+CXGBE PF Only Runtime Options
+^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
+
+- ``filtermode`` (default **0**)
+
+  Apart from the 4-tuple (IP src/dst addresses and TCP/UDP src/dst port
+  addresses), there are only 40-bits available to match other fields in
+  packet headers. So, ``filtermode`` devarg allows user to dynamically
+  select a 40-bit supported match field combination for LETCAM (wildcard)
+  filters.
+
+  Default value of **0** makes driver pick the combination configured in
+  the firmware configuration file on the adapter.
+
+  The supported flags and their corresponding values are shown in table below.
+  These flags can be OR'd to create 1 of the multiple supported combinations
+  for LETCAM filters.
+
+        ==================      ======
+        FLAG                    VALUE
+        ==================      ======
+        Physical Port           0x1
+        PFVF                    0x2
+        Destination MAC         0x4
+        Ethertype               0x8
+        Inner VLAN              0x10
+        Outer VLAN              0x20
+        IP TOS                  0x40
+        IP Protocol             0x80
+        ==================      ======
+
+  The supported ``filtermode`` combinations and their corresponding OR'd
+  values are shown in table below.
+
+        +-----------------------------------+-----------+
+        | FILTERMODE COMBINATIONS           |   VALUE   |
+        +===================================+===========+
+        | Protocol, TOS, Outer VLAN, Port   |     0xE1  |
+        +-----------------------------------+-----------+
+        | Protocol, TOS, Outer VLAN         |     0xE0  |
+        +-----------------------------------+-----------+
+        | Protocol, TOS, Inner VLAN, Port   |     0xD1  |
+        +-----------------------------------+-----------+
+        | Protocol, TOS, Inner VLAN         |     0xD0  |
+        +-----------------------------------+-----------+
+        | Protocol, TOS, PFVF, Port         |     0xC3  |
+        +-----------------------------------+-----------+
+        | Protocol, TOS, PFVF               |     0xC2  |
+        +-----------------------------------+-----------+
+        | Protocol, TOS, Port               |     0xC1  |
+        +-----------------------------------+-----------+
+        | Protocol, TOS                     |     0xC0  |
+        +-----------------------------------+-----------+
+        | Protocol, Outer VLAN, Port        |     0xA1  |
+        +-----------------------------------+-----------+
+        | Protocol, Outer VLAN              |     0xA0  |
+        +-----------------------------------+-----------+
+        | Protocol, Inner VLAN, Port        |     0x91  |
+        +-----------------------------------+-----------+
+        | Protocol, Inner VLAN              |     0x90  |
+        +-----------------------------------+-----------+
+        | Protocol, Ethertype, DstMAC, Port |     0x8D  |
+        +-----------------------------------+-----------+
+        | Protocol, Ethertype, DstMAC       |     0x8C  |
+        +-----------------------------------+-----------+
+        | Protocol, Ethertype, Port         |     0x89  |
+        +-----------------------------------+-----------+
+        | Protocol, Ethertype               |     0x88  |
+        +-----------------------------------+-----------+
+        | Protocol, DstMAC, PFVF, Port      |     0x87  |
+        +-----------------------------------+-----------+
+        | Protocol, DstMAC, PFVF            |     0x86  |
+        +-----------------------------------+-----------+
+        | Protocol, DstMAC, Port            |     0x85  |
+        +-----------------------------------+-----------+
+        | Protocol, DstMAC                  |     0x84  |
+        +-----------------------------------+-----------+
+        | Protocol, PFVF, Port              |     0x83  |
+        +-----------------------------------+-----------+
+        | Protocol, PFVF                    |     0x82  |
+        +-----------------------------------+-----------+
+        | Protocol, Port                    |     0x81  |
+        +-----------------------------------+-----------+
+        | Protocol                          |     0x80  |
+        +-----------------------------------+-----------+
+        | TOS, Outer VLAN, Port             |     0x61  |
+        +-----------------------------------+-----------+
+        | TOS, Outer VLAN                   |     0x60  |
+        +-----------------------------------+-----------+
+        | TOS, Inner VLAN, Port             |     0x51  |
+        +-----------------------------------+-----------+
+        | TOS, Inner VLAN                   |     0x50  |
+        +-----------------------------------+-----------+
+        | TOS, Ethertype, DstMAC, Port      |     0x4D  |
+        +-----------------------------------+-----------+
+        | TOS, Ethertype, DstMAC            |     0x4C  |
+        +-----------------------------------+-----------+
+        | TOS, Ethertype, Port              |     0x49  |
+        +-----------------------------------+-----------+
+        | TOS, Ethertype                    |     0x48  |
+        +-----------------------------------+-----------+
+        | TOS, DstMAC, PFVF, Port           |     0x47  |
+        +-----------------------------------+-----------+
+        | TOS, DstMAC, PFVF                 |     0x46  |
+        +-----------------------------------+-----------+
+        | TOS, DstMAC, Port                 |     0x45  |
+        +-----------------------------------+-----------+
+        | TOS, DstMAC                       |     0x44  |
+        +-----------------------------------+-----------+
+        | TOS, PFVF, Port                   |     0x43  |
+        +-----------------------------------+-----------+
+        | TOS, PFVF                         |     0x42  |
+        +-----------------------------------+-----------+
+        | TOS, Port                         |     0x41  |
+        +-----------------------------------+-----------+
+        | TOS                               |     0x40  |
+        +-----------------------------------+-----------+
+        | Outer VLAN, Inner VLAN, Port      |     0x31  |
+        +-----------------------------------+-----------+
+        | Outer VLAN, Ethertype, Port       |     0x29  |
+        +-----------------------------------+-----------+
+        | Outer VLAN, Ethertype             |     0x28  |
+        +-----------------------------------+-----------+
+        | Outer VLAN, DstMAC, Port          |     0x25  |
+        +-----------------------------------+-----------+
+        | Outer VLAN, DstMAC                |     0x24  |
+        +-----------------------------------+-----------+
+        | Outer VLAN, Port                  |     0x21  |
+        +-----------------------------------+-----------+
+        | Outer VLAN                        |     0x20  |
+        +-----------------------------------+-----------+
+        | Inner VLAN, Ethertype, Port       |     0x19  |
+        +-----------------------------------+-----------+
+        | Inner VLAN, Ethertype             |     0x18  |
+        +-----------------------------------+-----------+
+        | Inner VLAN, DstMAC, Port          |     0x15  |
+        +-----------------------------------+-----------+
+        | Inner VLAN, DstMAC                |     0x14  |
+        +-----------------------------------+-----------+
+        | Inner VLAN, Port                  |     0x11  |
+        +-----------------------------------+-----------+
+        | Inner VLAN                        |     0x10  |
+        +-----------------------------------+-----------+
+        | Ethertype, DstMAC, Port           |     0xD   |
+        +-----------------------------------+-----------+
+        | Ethertype, DstMAC                 |     0xC   |
+        +-----------------------------------+-----------+
+        | Ethertype, PFVF, Port             |     0xB   |
+        +-----------------------------------+-----------+
+        | Ethertype, PFVF                   |     0xA   |
+        +-----------------------------------+-----------+
+        | Ethertype, Port                   |     0x9   |
+        +-----------------------------------+-----------+
+        | Ethertype                         |     0x8   |
+        +-----------------------------------+-----------+
+        | DstMAC, PFVF, Port                |     0x7   |
+        +-----------------------------------+-----------+
+        | DstMAC, PFVF                      |     0x6   |
+        +-----------------------------------+-----------+
+        | DstMAC, Port                      |     0x5   |
+        +-----------------------------------+-----------+
+        | Destination MAC                   |     0x4   |
+        +-----------------------------------+-----------+
+        | PFVF, Port                        |     0x3   |
+        +-----------------------------------+-----------+
+        | PFVF                              |     0x2   |
+        +-----------------------------------+-----------+
+        | Physical Port                     |     0x1   +
+        +-----------------------------------+-----------+
+
+  For example, to enable matching ``ethertype`` field in Ethernet
+  header, and ``protocol`` field in IPv4 header, the ``filtermode``
+  combination must be given as:
+
+  .. code-block:: console
+
+     testpmd -w 02:00.4,filtermode=0x88 -- -i
+
+- ``filtermask`` (default **0**)
+
+  ``filtermask`` devarg works similar to ``filtermode``, but is used
+  to configure a filter mode combination for HASH (exact-match) filters.
+
+  .. note::
+
+     The combination chosen for ``filtermask`` devarg **must be a subset** of
+     the combination chosen for ``filtermode`` devarg.
+
+  Default value of **0** makes driver pick the combination configured in
+  the firmware configuration file on the adapter.
+
+  Note that the filter rule will only be inserted in HASH region, if the
+  rule contains **all** the fields specified in the ``filtermask`` combination.
+  Otherwise, the filter rule will get inserted in LETCAM region.
+
+  The same combination list explained in the tables in ``filtermode`` devarg
+  section earlier applies for ``filtermask`` devarg, as well.
+
+  For example, to enable matching only protocol field in IPv4 header, the
+  ``filtermask`` combination must be given as:
+
+  .. code-block:: console
+
+     testpmd -w 02:00.4,filtermode=0x88,filtermask=0x80 -- -i
+
+.. _driver-compilation:
+
+Driver compilation and testing
+------------------------------
+
+Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
+for details.
+
+Linux
+-----
+
+.. _linux-installation:
+
+Linux Installation
+~~~~~~~~~~~~~~~~~~
+
+Steps to manually install the latest firmware from the downloaded Chelsio
+Unified Wire package for Linux operating system are as follows:
 
-  Toggle debugging code. Enabling this option adds additional generic debugging
-  messages at the cost of lower performance.
+#. Load the kernel module:
 
-- ``CONFIG_RTE_LIBRTE_CXGBE_DEBUG_REG`` (default **n**)
+   .. code-block:: console
 
-  Toggle debugging code. Enabling this option adds additional registers related
-  run-time checks and debugging messages at the cost of lower performance.
+      modprobe cxgb4
 
-- ``CONFIG_RTE_LIBRTE_CXGBE_DEBUG_MBOX`` (default **n**)
+#. Use ifconfig to get the interface name assigned to Chelsio card:
 
-  Toggle debugging code. Enabling this option adds additional firmware mailbox
-  related run-time checks and debugging messages at the cost of lower
-  performance.
+   .. code-block:: console
 
-- ``CONFIG_RTE_LIBRTE_CXGBE_DEBUG_TX`` (default **n**)
+      ifconfig -a | grep "00:07:43"
 
-  Toggle debugging code. Enabling this option adds additional transmission data
-  path run-time checks and debugging messages at the cost of lower performance.
+   Example output:
 
-- ``CONFIG_RTE_LIBRTE_CXGBE_DEBUG_RX`` (default **n**)
+   .. code-block:: console
 
-  Toggle debugging code. Enabling this option adds additional receiving data
-  path run-time checks and debugging messages at the cost of lower performance.
+      p1p1      Link encap:Ethernet  HWaddr 00:07:43:2D:EA:C0
+      p1p2      Link encap:Ethernet  HWaddr 00:07:43:2D:EA:C8
 
-Prerequisites
--------------
+#. Install cxgbtool:
 
-- Requires firmware version **1.13.32.0** and higher. Visit
-  `Chelsio Communications <http://www.chelsio.com>`_ to get latest firmware.
+   .. code-block:: console
 
-Sample Application Notes
--------------------------
+      cd <path_to_uwire>/tools/cxgbtool
+      make install
+
+#. Use cxgbtool to load the firmware config file onto the card:
+
+   .. code-block:: console
 
-This section demonstrates how to launch **testpmd** with Chelsio T5
-devices managed by librte_pmd_cxgbe.
+      cxgbtool p1p1 loadcfg <path_to_uwire>/src/network/firmware/t5-config.txt
+
+#. Use cxgbtool to load the firmware image onto the card:
+
+   .. code-block:: console
+
+      cxgbtool p1p1 loadfw <path_to_uwire>/src/network/firmware/t5fw-*.bin
+
+#. Unload and reload the kernel module:
+
+   .. code-block:: console
+
+      modprobe -r cxgb4
+      modprobe cxgb4
+
+#. Verify with ethtool:
+
+   .. code-block:: console
+
+      ethtool -i p1p1 | grep "firmware"
+
+   Example output:
+
+   .. code-block:: console
+
+      firmware-version: 1.24.11.0, TP 0.1.23.2
+
+Running testpmd
+~~~~~~~~~~~~~~~
+
+This section demonstrates how to launch **testpmd** with Chelsio
+devices managed by librte_pmd_cxgbe in Linux operating system.
 
 #. Load the kernel module:
 
@@ -131,7 +449,7 @@ devices managed by librte_pmd_cxgbe.
 
    .. note::
 
-      Both the interfaces of a Chelsio T5 2-port adapter are bound to the
+      Both the interfaces of a Chelsio 2-port adapter are bound to the
       same PCI bus address.
 
 #. Unload the kernel module:
@@ -140,60 +458,337 @@ devices managed by librte_pmd_cxgbe.
 
       modprobe -ar cxgb4 csiostor
 
-#. Request huge pages:
+#. Running testpmd
+
+   Follow instructions available in the document
+   :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
+   to run testpmd.
+
+   .. note::
+
+      Currently, CXGBE PMD only supports the binding of PF4 for Chelsio NICs.
+
+   Example output:
+
+   .. code-block:: console
+
+      [...]
+      EAL: PCI device 0000:02:00.4 on NUMA socket -1
+      EAL:   probe driver: 1425:5401 rte_cxgbe_pmd
+      EAL:   PCI memory mapped at 0x7fd7c0200000
+      EAL:   PCI memory mapped at 0x7fd77cdfd000
+      EAL:   PCI memory mapped at 0x7fd7c10b7000
+      PMD: rte_cxgbe_pmd: fw: 1.24.11.0, TP: 0.1.23.2
+      PMD: rte_cxgbe_pmd: Coming up as MASTER: Initializing adapter
+      Interactive-mode selected
+      Configuring Port 0 (socket 0)
+      Port 0: 00:07:43:2D:EA:C0
+      Configuring Port 1 (socket 0)
+      Port 1: 00:07:43:2D:EA:C8
+      Checking link statuses...
+      PMD: rte_cxgbe_pmd: Port0: passive DA port module inserted
+      PMD: rte_cxgbe_pmd: Port1: passive DA port module inserted
+      Port 0 Link Up - speed 10000 Mbps - full-duplex
+      Port 1 Link Up - speed 10000 Mbps - full-duplex
+      Done
+      testpmd>
+
+   .. note::
+
+      Flow control pause TX/RX is disabled by default and can be enabled via
+      testpmd. Refer section :ref:`flow-control` for more details.
+
+Configuring SR-IOV Virtual Functions
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+This section demonstrates how to enable SR-IOV virtual functions
+on Chelsio NICs and demonstrates how to run testpmd with SR-IOV
+virtual functions.
+
+#. Load the kernel module:
+
+   .. code-block:: console
+
+      modprobe cxgb4
+
+#. Get the PCI bus addresses of the interfaces bound to cxgb4 driver:
+
+   .. code-block:: console
+
+      dmesg | tail -2
+
+   Example output:
+
+   .. code-block:: console
+
+      cxgb4 0000:02:00.4 p1p1: renamed from eth0
+      cxgb4 0000:02:00.4 p1p2: renamed from eth1
+
+   .. note::
+
+      Both the interfaces of a Chelsio 2-port adapter are bound to the
+      same PCI bus address.
+
+#. Use ifconfig to get the interface name assigned to Chelsio card:
+
+   .. code-block:: console
+
+      ifconfig -a | grep "00:07:43"
+
+   Example output:
+
+   .. code-block:: console
+
+      p1p1      Link encap:Ethernet  HWaddr 00:07:43:2D:EA:C0
+      p1p2      Link encap:Ethernet  HWaddr 00:07:43:2D:EA:C8
+
+#. Bring up the interfaces:
+
+   .. code-block:: console
+
+      ifconfig p1p1 up
+      ifconfig p1p2 up
+
+#. Instantiate SR-IOV Virtual Functions. PF0..3 can be used for
+   SR-IOV VFs. Multiple VFs can be instantiated on each of PF0..3.
+   To instantiate one SR-IOV VF on each PF0 and PF1:
+
+   .. code-block:: console
+
+      echo 1 > /sys/bus/pci/devices/0000\:02\:00.0/sriov_numvfs
+      echo 1 > /sys/bus/pci/devices/0000\:02\:00.1/sriov_numvfs
+
+#. Get the PCI bus addresses of the virtual functions:
+
+   .. code-block:: console
+
+      lspci | grep -i "Chelsio" | grep -i "VF"
+
+   Example output:
+
+   .. code-block:: console
+
+      02:01.0 Ethernet controller: Chelsio Communications Inc T540-CR Unified Wire Ethernet Controller [VF]
+      02:01.1 Ethernet controller: Chelsio Communications Inc T540-CR Unified Wire Ethernet Controller [VF]
+
+#. Running testpmd
+
+   Follow instructions available in the document
+   :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
+   to bind virtual functions and run testpmd.
+
+   Example output:
+
+   .. code-block:: console
+
+      [...]
+      EAL: PCI device 0000:02:01.0 on NUMA socket 0
+      EAL:   probe driver: 1425:5803 net_cxgbevf
+      PMD: rte_cxgbe_pmd: Firmware version: 1.24.11.0
+      PMD: rte_cxgbe_pmd: TP Microcode version: 0.1.23.2
+      PMD: rte_cxgbe_pmd: Chelsio rev 0
+      PMD: rte_cxgbe_pmd: No bootstrap loaded
+      PMD: rte_cxgbe_pmd: No Expansion ROM loaded
+      PMD: rte_cxgbe_pmd:  0000:02:01.0 Chelsio rev 0 1G/10GBASE-SFP
+      EAL: PCI device 0000:02:01.1 on NUMA socket 0
+      EAL:   probe driver: 1425:5803 net_cxgbevf
+      PMD: rte_cxgbe_pmd: Firmware version: 1.24.11.0
+      PMD: rte_cxgbe_pmd: TP Microcode version: 0.1.23.2
+      PMD: rte_cxgbe_pmd: Chelsio rev 0
+      PMD: rte_cxgbe_pmd: No bootstrap loaded
+      PMD: rte_cxgbe_pmd: No Expansion ROM loaded
+      PMD: rte_cxgbe_pmd:  0000:02:01.1 Chelsio rev 0 1G/10GBASE-SFP
+      Configuring Port 0 (socket 0)
+      Port 0: 06:44:29:44:40:00
+      Configuring Port 1 (socket 0)
+      Port 1: 06:44:29:44:40:10
+      Checking link statuses...
+      Done
+      testpmd>
+
+FreeBSD
+-------
+
+.. _freebsd-installation:
+
+FreeBSD Installation
+~~~~~~~~~~~~~~~~~~~~
+
+Steps to manually install the latest firmware from the downloaded Chelsio
+Unified Wire package for FreeBSD operating system are as follows:
+
+#. Load the kernel module:
+
+   .. code-block:: console
+
+      kldload if_cxgbe
+
+#. Use dmesg to get the t5nex instance assigned to the Chelsio card:
+
+   .. code-block:: console
+
+      dmesg | grep "t5nex"
+
+   Example output:
+
+   .. code-block:: console
+
+      t5nex0: <Chelsio T520-CR> irq 16 at device 0.4 on pci2
+      cxl0: <port 0> on t5nex0
+      cxl1: <port 1> on t5nex0
+      t5nex0: PCIe x8, 2 ports, 14 MSI-X interrupts, 31 eq, 13 iq
+
+   In the example above, a Chelsio T520-CR card is bound to a t5nex0 instance.
+
+#. Install cxgbetool from FreeBSD source repository:
+
+   .. code-block:: console
+
+      cd <path_to_FreeBSD_source>/tools/tools/cxgbetool/
+      make && make install
+
+#. Use cxgbetool to load the firmware image onto the card:
+
+   .. code-block:: console
+
+      cxgbetool t5nex0 loadfw <path_to_uwire>/src/network/firmware/t5fw-*.bin
+
+#. Unload and reload the kernel module:
+
+   .. code-block:: console
+
+      kldunload if_cxgbe
+      kldload if_cxgbe
+
+#. Verify with sysctl:
+
+   .. code-block:: console
+
+      sysctl -a | grep "t5nex" | grep "firmware"
+
+   Example output:
+
+   .. code-block:: console
+
+      dev.t5nex.0.firmware_version: 1.24.11.0
+
+Running testpmd
+~~~~~~~~~~~~~~~
+
+This section demonstrates how to launch **testpmd** with Chelsio
+devices managed by librte_pmd_cxgbe in FreeBSD operating system.
+
+#. Change to DPDK source directory where the target has been compiled in
+   section :ref:`driver-compilation`:
+
+   .. code-block:: console
+
+      cd <DPDK-source-directory>
+
+#. Copy the contigmem kernel module to /boot/kernel directory:
+
+   .. code-block:: console
+
+      cp x86_64-native-freebsd-clang/kmod/contigmem.ko /boot/kernel/
+
+#. Add the following lines to /boot/loader.conf:
 
    .. code-block:: console
 
-      echo 1024 > /sys/kernel/mm/hugepages/hugepages-2048kB/nr_hugepages/nr_hugepages
+      # reserve 2 x 1G blocks of contiguous memory using contigmem driver
+      hw.contigmem.num_buffers=2
+      hw.contigmem.buffer_size=1073741824
+      # load contigmem module during boot process
+      contigmem_load="YES"
+
+   The above lines load the contigmem kernel module during boot process and
+   allocate 2 x 1G blocks of contiguous memory to be used for DPDK later on.
+   This is to avoid issues with potential memory fragmentation during later
+   system up time, which may result in failure of allocating the contiguous
+   memory required for the contigmem kernel module.
 
-#. Load igb_uio or vfio-pci driver:
+#. Restart the system and ensure the contigmem module is loaded successfully:
 
    .. code-block:: console
 
-      insmod ./x86_64-native-linuxapp-gcc/kmod/igb_uio.ko
+      reboot
+      kldstat | grep "contigmem"
 
-   or
+   Example output:
 
    .. code-block:: console
 
-      modprobe vfio-pci
+      2    1 0xffffffff817f1000 3118     contigmem.ko
+
+#. Repeat step 1 to ensure that you are in the DPDK source directory.
 
-#. Bind the Chelsio T5 adapters to igb_uio or vfio-pci loaded in the previous
-   step:
+#. Load the cxgbe kernel module:
 
    .. code-block:: console
 
-      ./tools/dpdk_nic_bind.py --bind igb_uio 0000:02:00.4
+      kldload if_cxgbe
+
+#. Get the PCI bus addresses of the interfaces bound to t5nex driver:
+
+   .. code-block:: console
+
+      pciconf -l | grep "t5nex"
+
+   Example output:
+
+   .. code-block:: console
+
+      t5nex0@pci0:2:0:4: class=0x020000 card=0x00001425 chip=0x54011425 rev=0x00
+
+   In the above example, the t5nex0 is bound to 2:0:4 bus address.
+
+   .. note::
+
+      Both the interfaces of a Chelsio 2-port adapter are bound to the
+      same PCI bus address.
+
+#. Unload the kernel module:
+
+   .. code-block:: console
 
-   or
+      kldunload if_cxgbe
 
-   Setup VFIO permissions for regular users and then bind to vfio-pci:
+#. Set the PCI bus addresses to hw.nic_uio.bdfs kernel environment parameter:
 
    .. code-block:: console
 
-      sudo chmod a+x /dev/vfio
+      kenv hw.nic_uio.bdfs="2:0:4"
+
+   This automatically binds 2:0:4 to nic_uio kernel driver when it is loaded in
+   the next step.
+
+   .. note::
+
+      Currently, CXGBE PMD only supports the binding of PF4 for Chelsio NICs.
+
+#. Load nic_uio kernel driver:
 
-      sudo chmod 0666 /dev/vfio/*
+   .. code-block:: console
 
-      ./tools/dpdk_nic_bind.py --bind vfio-pci 0000:02:00.4
+      kldload ./x86_64-native-freebsd-clang/kmod/nic_uio.ko
 
 #. Start testpmd with basic parameters:
 
    .. code-block:: console
 
-      ./x86_64-native-linuxapp-gcc/app/testpmd -c 0xf -n 4 -w 0000:02:00.4 -- -i
+      ./x86_64-native-freebsd-clang/app/testpmd -l 0-3 -n 4 -w 0000:02:00.4 -- -i
 
    Example output:
 
    .. code-block:: console
 
       [...]
-      EAL: PCI device 0000:02:00.4 on NUMA socket -1
+      EAL: PCI device 0000:02:00.4 on NUMA socket 0
       EAL:   probe driver: 1425:5401 rte_cxgbe_pmd
-      EAL:   PCI memory mapped at 0x7fd7c0200000
-      EAL:   PCI memory mapped at 0x7fd77cdfd000
-      EAL:   PCI memory mapped at 0x7fd7c10b7000
-      PMD: rte_cxgbe_pmd: fw: 1.13.33.0, TP: 0.1.4.8
+      EAL:   PCI memory mapped at 0x8007ec000
+      EAL:   PCI memory mapped at 0x842800000
+      EAL:   PCI memory mapped at 0x80086c000
+      PMD: rte_cxgbe_pmd: fw: 1.24.11.0, TP: 0.1.23.2
       PMD: rte_cxgbe_pmd: Coming up as MASTER: Initializing adapter
       Interactive-mode selected
       Configuring Port 0 (socket 0)
@@ -207,3 +802,55 @@ devices managed by librte_pmd_cxgbe.
       Port 1 Link Up - speed 10000 Mbps - full-duplex
       Done
       testpmd>
+
+.. note::
+
+   Flow control pause TX/RX is disabled by default and can be enabled via
+   testpmd. Refer section :ref:`flow-control` for more details.
+
+Sample Application Notes
+------------------------
+
+.. _flow-control:
+
+Enable/Disable Flow Control
+~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+Flow control pause TX/RX is disabled by default and can be enabled via
+testpmd as follows:
+
+.. code-block:: console
+
+   testpmd> set flow_ctrl rx on tx on 0 0 0 0 mac_ctrl_frame_fwd off autoneg on 0
+   testpmd> set flow_ctrl rx on tx on 0 0 0 0 mac_ctrl_frame_fwd off autoneg on 1
+
+To disable again, run:
+
+.. code-block:: console
+
+   testpmd> set flow_ctrl rx off tx off 0 0 0 0 mac_ctrl_frame_fwd off autoneg off 0
+   testpmd> set flow_ctrl rx off tx off 0 0 0 0 mac_ctrl_frame_fwd off autoneg off 1
+
+Jumbo Mode
+~~~~~~~~~~
+
+There are two ways to enable sending and receiving of jumbo frames via testpmd.
+One method involves using the **mtu** command, which changes the mtu of an
+individual port without having to stop the selected port. Another method
+involves stopping all the ports first and then running **max-pkt-len** command
+to configure the mtu of all the ports with a single command.
+
+- To configure each port individually, run the mtu command as follows:
+
+  .. code-block:: console
+
+     testpmd> port config mtu 0 9000
+     testpmd> port config mtu 1 9000
+
+- To configure all the ports at once, stop all the ports first and run the
+  max-pkt-len command as follows:
+
+  .. code-block:: console
+
+     testpmd> port stop all
+     testpmd> port config all max-pkt-len 9000