The FM10K poll mode driver library provides support for the Intel FM10000
(FM10K) family of 40GbE/100GbE adapters.
+FTAG Based Forwarding of FM10K
+------------------------------
+
+FTAG Based Forwarding is a unique feature of FM10K. The FM10K family of NICs
+support the addition of a Fabric Tag (FTAG) to carry special information.
+The FTAG is placed at the beginning of the frame, it contains information
+such as where the packet comes from and goes, and the vlan tag. In FTAG based
+forwarding mode, the switch logic forwards packets according to glort (global
+resource tag) information, rather than the mac and vlan table. Currently this
+feature works only on PF.
+
+To enable this feature, the user should pass a devargs parameter to the eal
+like "-w 84:00.0,enable_ftag=1", and the application should make sure an
+appropriate FTAG is inserted for every frame on TX side.
Vector PMD for FM10K
--------------------
The Intel FM10000 family of NICs integrate a hardware switch and multiple host
interfaces. The FM10000 PMD driver only manages host interfaces. For the
switch component another switch driver has to be loaded prior to to the
-FM10000 PMD driver. The switch driver can be acquired for Intel support or
-from the `Match Interface <https://github.com/match-interface>`_ project.
+FM10000 PMD driver. The switch driver can be acquired from Intel support.
Only Testpoint is validated with DPDK, the latest version that has been
-validated with DPDK2.2 is 4.1.6.
+validated with DPDK is 4.1.6.
+
+Support for Switch Restart
+~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+For FM10000 multi host based design a DPDK app running in the VM or host needs
+to be aware of the switch's state since it may undergo a quit-restart. When
+the switch goes down the DPDK app will receive a LSC event indicating link
+status down, and the app should stop the worker threads that are polling on
+the Rx/Tx queues. When switch comes up, a LSC event indicating ``LINK_UP`` is
+sent to the app, which can then restart the FM10000 port to resume network
+processing.