doc: fix syntax in testpmd user guide
[dpdk.git] / doc / guides / testpmd_app_ug / testpmd_funcs.rst
index 975929e..71d831b 100644 (file)
@@ -1,5 +1,5 @@
 ..  BSD LICENSE
-    Copyright(c) 2010-2014 Intel Corporation. All rights reserved.
+    Copyright(c) 2010-2015 Intel Corporation. All rights reserved.
     All rights reserved.
 
     Redistribution and use in source and binary forms, with or without
     (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
     OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
 
+.. _testpmd_runtime:
+
 Testpmd Runtime Functions
 =========================
 
-Where the testpmd application is started in interactive mode, (-i|--interactive),
+Where the testpmd application is started in interactive mode, (``-i|--interactive``),
 it displays a prompt that can be used to start and stop forwarding,
-configure the application, display statistics, set the Flow Director and other tasks.
-
-.. code-block:: console
+configure the application, display statistics, set the Flow Director and other tasks::
 
-    testpmd>
+   testpmd>
 
 The testpmd prompt has some, limited, readline support.
-Common bash command- line functions such as Ctrl+a and Ctrl+e to go to the start and end of the prompt line are supported
+Common bash command-line functions such as ``Ctrl+a`` and ``Ctrl+e`` to go to the start and end of the prompt line are supported
 as well as access to the command history via the up-arrow.
 
 There is also support for tab completion.
-If you type a partial command and hit <TAB> you get a list of the available completions:
+If you type a partial command and hit ``<TAB>`` you get a list of the available completions:
 
 .. code-block:: console
 
-    testpmd> show port <TAB>
+   testpmd> show port <TAB>
+
+       info [Mul-choice STRING]: show|clear port info|stats|fdir|stat_qmap X
+       info [Mul-choice STRING]: show|clear port info|stats|fdir|stat_qmap all
+       stats [Mul-choice STRING]: show|clear port info|stats|fdir|stat_qmap X
+       stats [Mul-choice STRING]: show|clear port info|stats|fdir|stat_qmap all
+       ...
+
+
+.. note::
+
+   Some examples in this document are too long to fit on one line are are shown wrapped at `"\\"` for display purposes::
+
+      testpmd> set flow_ctrl rx (on|off) tx (on|off) (high_water) (low_water) \
+               (pause_time) (send_xon) (port_id)
 
-        info [Mul-choice STRING]: show|clear port info|stats|fdir|stat_qmap X
-        info [Mul-choice STRING]: show|clear port info|stats|fdir|stat_qmap all
-        stats [Mul-choice STRING]: show|clear port info|stats|fdir|stat_qmap X
-        stats [Mul-choice STRING]: show|clear port info|stats|fdir|stat_qmap all
-        ...
+In the real ``testpmd>`` prompt these commands should be on a single line.
 
 Help Functions
 --------------
@@ -64,17 +74,16 @@ These are divided into sections and can be accessed using help, help section or
 
 .. code-block:: console
 
-    testpmd> help
+   testpmd> help
+
+       help control    : Start and stop forwarding.
+       help display    : Displaying port, stats and config information.
+       help config     : Configuration information.
+       help ports      : Configuring ports.
+       help registers  : Reading and setting port registers.
+       help filters    : Filters configuration help.
+       help all        : All of the above sections.
 
-        Help is available for the following sections:
-        help control    : Start and stop forwarding.
-        help display    : Displaying port, stats and config information.
-        help config     : Configuration information.
-        help ports      : Configuring ports.
-        help flowdir    : Flow Director filter help.
-        help registers  : Reading and setting port registers.
-        help filters    : Filters configuration help.
-        help all        : All of the above sections.
 
 Control Functions
 -----------------
@@ -82,30 +91,31 @@ Control Functions
 start
 ~~~~~
 
-Start packet forwarding with current configuration:
+Start packet forwarding with current configuration::
 
-start
+   testpmd> start
 
 start tx_first
 ~~~~~~~~~~~~~~
 
-Start packet forwarding with current configuration after sending one burst of packets:
+Start packet forwarding with current configuration after sending one burst of packets::
 
-start tx_first
+   testpmd> start tx_first
 
 stop
 ~~~~
 
-Stop packet forwarding, and display accumulated statistics:
+Stop packet forwarding, and display accumulated statistics::
 
-stop
+   testpmd> stop
 
 quit
 ~~~~
 
-Quit to prompt:
+Quit to prompt::
+
+   testpmd> quit
 
-quit
 
 Display Functions
 -----------------
@@ -116,125 +126,181 @@ testpmd configuration or the NIC status.
 show port
 ~~~~~~~~~
 
-Display information for a given port or all ports:
+Display information for a given port or all ports::
 
-show port (info|stats|fdir|stat_qmap) (port_id|all)
+   testpmd> show port (info|stats|fdir|stat_qmap) (port_id|all)
 
 The available information categories are:
 
-info    : General port information such as MAC address.
+* ``info``: General port information such as MAC address.
 
-stats   : RX/TX statistics.
+* ``stats``: RX/TX statistics.
 
-fdir    : Flow Director information and statistics.
+* ``fdir``: Flow Director information and statistics.
 
-stat_qmap : Queue statistics mapping.
+* ``stat_qmap``: Queue statistics mapping.
 
 For example:
 
 .. code-block:: console
 
-    testpmd> show port info 0
-
-    ********************* Infos for port 0 *********************
-
-    MAC address: XX:XX:XX:XX:XX:XX
-    Link status: up
-    Link speed: 10000 Mbps
-    Link duplex: full-duplex
-    Promiscuous mode: enabled
-    Allmulticast mode: disabled
-    Maximum number of MAC addresses: 127
-    VLAN offload:
-        strip on
-        filter on
-        qinq(extend) off
+   testpmd> show port info 0
+
+   ********************* Infos for port 0 *********************
+
+   MAC address: XX:XX:XX:XX:XX:XX
+   Connect to socket: 0
+   memory allocation on the socket: 0
+   Link status: up
+   Link speed: 40000 Mbps
+   Link duplex: full-duplex
+   Promiscuous mode: enabled
+   Allmulticast mode: disabled
+   Maximum number of MAC addresses: 64
+   Maximum number of MAC addresses of hash filtering: 0
+   VLAN offload:
+       strip on
+       filter on
+       qinq(extend) off
+   Redirection table size: 512
+   Supported flow types:
+     ipv4-frag
+     ipv4-tcp
+     ipv4-udp
+     ipv4-sctp
+     ipv4-other
+     ipv6-frag
+     ipv6-tcp
+     ipv6-udp
+     ipv6-sctp
+     ipv6-other
+     l2_payload
 
 show port rss reta
 ~~~~~~~~~~~~~~~~~~
 
-Display the rss redirection table entry indicated by masks on port X:
+Display the rss redirection table entry indicated by masks on port X::
 
-show port (port_id) rss reta (size) (mask0, mask1...)
+   testpmd> show port (port_id) rss reta (size) (mask0, mask1...)
 
 size is used to indicate the hardware supported reta size
 
 show port rss-hash
 ~~~~~~~~~~~~~~~~~~
 
-Display the RSS hash functions and RSS hash key of port (port_id).
+Display the RSS hash functions and RSS hash key of a port::
 
-show port (port_id) rss-hash [key] clear port
-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+   testpmd> show port (port_id) rss-hash [key]
 
-Clear the port statistics for a given port or for all ports:
+clear port
+~~~~~~~~~~
 
-clear port (info|stats|fdir|stat_qmap) (port_id|all)
+Clear the port statistics for a given port or for all ports::
 
-For example:
+   testpmd> clear port (info|stats|fdir|stat_qmap) (port_id|all)
 
-.. code-block:: console
+For example::
 
-    testpmd> clear port stats all
+   testpmd> clear port stats all
 
 show config
 ~~~~~~~~~~~
 
 Displays the configuration of the application.
-The configuration comes from the command-line, the runtime or the application defaults:
+The configuration comes from the command-line, the runtime or the application defaults::
 
-show config (rxtx|cores|fwd)
+   testpmd> show config (rxtx|cores|fwd)
 
 The available information categories are:
 
-rxtx  : RX/TX configuration items.
+* ``rxtx``: RX/TX configuration items.
 
-cores : List of forwarding cores.
+* ``cores``: List of forwarding cores.
 
-fwd   : Packet forwarding configuration.
+* ``fwd``: Packet forwarding configuration.
 
 For example:
 
 .. code-block:: console
 
-    testpmd> show config rxtx
+   testpmd> show config rxtx
+
+   io packet forwarding - CRC stripping disabled - packets/burst=16
+   nb forwarding cores=2 - nb forwarding ports=1
+   RX queues=1 - RX desc=128 - RX free threshold=0
+   RX threshold registers: pthresh=8 hthresh=8 wthresh=4
+   TX queues=1 - TX desc=512 - TX free threshold=0
+   TX threshold registers: pthresh=36 hthresh=0 wthresh=0
+   TX RS bit threshold=0 - TXQ flags=0x0
+
+set fwd
+~~~~~~~
+
+Set the packet forwarding mode::
+
+   testpmd> set fwd (io|mac|mac_retry|macswap|flowgen| \
+                     rxonly|txonly|csum|icmpecho)
+
+The available information categories are:
+
+* ``io``: Forwards packets "as-is" in I/O mode.
+  This is the fastest possible forwarding operation as it does not access packets data.
+  This is the default mode.
+
+* ``mac``: Changes the source and the destination Ethernet addresses of packets before forwarding them.
+
+* ``mac_retry``: Same as "mac" forwarding mode, but includes retries if the destination queue is full.
+
+* ``macswap``: MAC swap forwarding mode.
+  Swaps the source and the destination Ethernet addresses of packets before forwarding them.
+
+* ``flowgen``: Multi-flow generation mode.
+  Originates a number of flows (with varying destination IP addresses), and terminate receive traffic.
+
+* ``rxonly``: Receives packets but doesn't transmit them.
+
+* ``txonly``: Generates and transmits packets without receiving any.
+
+* ``csum``: Changes the checksum field with hardware or software methods depending on the offload flags on the packet.
+
+* ``icmpecho``: Receives a burst of packets, lookup for IMCP echo requests and, if any, send back ICMP echo replies.
+
+* ``ieee1588``: Demonstrate L2 IEEE1588 V2 PTP timestamping for RX and TX. Requires ``CONFIG_RTE_LIBRTE_IEEE1588=y``.
+
+Note: TX timestamping is only available in the "Full Featured" TX path. To force ``testpmd`` into this mode set ``--txqflags=0``.
+
+Example::
+
+   testpmd> set fwd rxonly
+
+   Set rxonly packet forwarding mode
 
-    io packet forwarding - CRC stripping disabled - packets/burst=16
-    nb forwarding cores=2 - nb forwarding ports=1
-    RX queues=1 - RX desc=128 - RX free threshold=0
-    RX threshold registers: pthresh=8 hthresh=8 wthresh=4
-    TX queues=1 - TX desc=512 - TX free threshold=0
-    TX threshold registers: pthresh=36 hthresh=0 wthresh=0
-    TX RS bit threshold=0 - TXQ flags=0x0
 
 read rxd
 ~~~~~~~~
 
-Display an RX descriptor for a port RX queue:
+Display an RX descriptor for a port RX queue::
 
-read rxd (port_id) (queue_id) (rxd_id)
+   testpmd> read rxd (port_id) (queue_id) (rxd_id)
 
-For example:
+For example::
 
-.. code-block:: console
-
-    testpmd> read rxd 0 0 4
+   testpmd> read rxd 0 0 4
         0x0000000B - 0x001D0180 / 0x0000000B - 0x001D0180
 
 read txd
 ~~~~~~~~
 
-Display a TX descriptor for a port TX queue:
+Display a TX descriptor for a port TX queue::
 
-read txd (port_id) (queue_id) (txd_id)
+   testpmd> read txd (port_id) (queue_id) (txd_id)
 
-For example:
+For example::
 
-.. code-block:: console
-
-    testpmd> read txd 0 0 4
+   testpmd> read txd 0 0 4
         0x00000001 - 0x24C3C440 / 0x000F0000 - 0x2330003C
 
+
 Configuration Functions
 -----------------------
 
@@ -244,21 +310,21 @@ This section details the available configuration functions that are available.
 
 .. note::
 
-    Configuration changes only become active when forwarding is started/restarted.
+   Configuration changes only become active when forwarding is started/restarted.
 
 set default
 ~~~~~~~~~~~
 
-Reset forwarding to the default configuration:
+Reset forwarding to the default configuration::
 
-set default
+   testpmd> set default
 
 set verbose
 ~~~~~~~~~~~
 
-Set the debug verbosity level:
+Set the debug verbosity level::
 
-set verbose (level)
+   testpmd> set verbose (level)
 
 Currently the only available levels are 0 (silent except for error) and 1 (fully verbose).
 
@@ -269,1417 +335,1445 @@ Set the number of ports used by the application:
 
 set nbport (num)
 
-This is equivalent to the --nb-ports command-line option.
+This is equivalent to the ``--nb-ports`` command-line option.
 
 set nbcore
 ~~~~~~~~~~
 
-Set the number of cores used by the application:
+Set the number of cores used by the application::
 
-set nbcore (num)
+   testpmd> set nbcore (num)
 
-This is equivalent to the --nb-cores command-line option.
+This is equivalent to the ``--nb-cores`` command-line option.
 
 .. note::
 
-    The number of cores used must not be greater than number of ports used multiplied by the number of queues per port.
+   The number of cores used must not be greater than number of ports used multiplied by the number of queues per port.
 
 set coremask
 ~~~~~~~~~~~~
 
-Set the forwarding cores hexadecimal mask:
+Set the forwarding cores hexadecimal mask::
 
-set coremask (mask)
+   testpmd> set coremask (mask)
 
-This is equivalent to the --coremask command-line option.
+This is equivalent to the ``--coremask`` command-line option.
 
 .. note::
 
-    The master lcore is reserved for command line parsing only and cannot be masked on for packet forwarding.
+   The master lcore is reserved for command line parsing only and cannot be masked on for packet forwarding.
 
 set portmask
 ~~~~~~~~~~~~
 
-Set the forwarding ports hexadecimal mask:
+Set the forwarding ports hexadecimal mask::
 
-set portmask (mask)
+   testpmd> set portmask (mask)
 
-This is equivalent to the --portmask command-line option.
+This is equivalent to the ``--portmask`` command-line option.
 
 set burst
 ~~~~~~~~~
 
-Set number of packets per burst:
+Set number of packets per burst::
 
-set burst (num)
+   testpmd> set burst (num)
 
-This is equivalent to the --burst command-line option.
+This is equivalent to the ``--burst command-line`` option.
 
-In mac_retry forwarding mode, the transmit delay time and number of retries can also be set.
+In ``mac_retry`` forwarding mode, the transmit delay time and number of retries can also be set::
 
-set burst tx delay (micrseconds) retry (num)
+   testpmd> set burst tx delay (micrseconds) retry (num)
 
 set txpkts
 ~~~~~~~~~~
 
-Set the length of each segment of the TX-ONLY packets:
+Set the length of each segment of the TX-ONLY packets::
 
-set txpkts (x[,y]*)
+   testpmd> set txpkts (x[,y]*)
 
 Where x[,y]* represents a CSV list of values, without white space.
 
 set corelist
 ~~~~~~~~~~~~
 
-Set the list of forwarding cores:
+Set the list of forwarding cores::
 
-set corelist (x[,y]*)
+   testpmd> set corelist (x[,y]*)
 
 For example, to change the forwarding cores:
 
 .. code-block:: console
 
-    testpmd> set corelist 3,1
-    testpmd> show config fwd
+   testpmd> set corelist 3,1
+   testpmd> show config fwd
 
-    io packet forwarding - ports=2 - cores=2 - streams=2 - NUMA support disabled
-    Logical Core 3 (socket 0) forwards packets on 1 streams:
-    RX P=0/Q=0 (socket 0) -> TX P=1/Q=0 (socket 0) peer=02:00:00:00:00:01
-    Logical Core 1 (socket 0) forwards packets on 1 streams:
-    RX P=1/Q=0 (socket 0) -> TX P=0/Q=0 (socket 0) peer=02:00:00:00:00:00
+   io packet forwarding - ports=2 - cores=2 - streams=2 - NUMA support disabled
+   Logical Core 3 (socket 0) forwards packets on 1 streams:
+   RX P=0/Q=0 (socket 0) -> TX P=1/Q=0 (socket 0) peer=02:00:00:00:00:01
+   Logical Core 1 (socket 0) forwards packets on 1 streams:
+   RX P=1/Q=0 (socket 0) -> TX P=0/Q=0 (socket 0) peer=02:00:00:00:00:00
 
 .. note::
 
-    The cores are used in the same order as specified on the command line.
+   The cores are used in the same order as specified on the command line.
 
 set portlist
 ~~~~~~~~~~~~
 
-Set the list of forwarding ports:
+Set the list of forwarding ports::
 
-set portlist (x[,y]*)
+   testpmd> set portlist (x[,y]*)
 
 For example, to change the port forwarding:
 
 .. code-block:: console
 
-    testpmd> set portlist 0,2,1,3
-    testpmd> show config fwd
+   testpmd> set portlist 0,2,1,3
+   testpmd> show config fwd
 
-    io packet forwarding - ports=4 - cores=1 - streams=4
-    Logical Core 3 (socket 0) forwards packets on 4 streams:
-    RX P=0/Q=0 (socket 0) -> TX P=2/Q=0 (socket 0) peer=02:00:00:00:00:01
-    RX P=2/Q=0 (socket 0) -> TX P=0/Q=0 (socket 0) peer=02:00:00:00:00:00
-    RX P=1/Q=0 (socket 0) -> TX P=3/Q=0 (socket 0) peer=02:00:00:00:00:03
-    RX P=3/Q=0 (socket 0) -> TX P=1/Q=0 (socket 0) peer=02:00:00:00:00:02
+   io packet forwarding - ports=4 - cores=1 - streams=4
+   Logical Core 3 (socket 0) forwards packets on 4 streams:
+   RX P=0/Q=0 (socket 0) -> TX P=2/Q=0 (socket 0) peer=02:00:00:00:00:01
+   RX P=2/Q=0 (socket 0) -> TX P=0/Q=0 (socket 0) peer=02:00:00:00:00:00
+   RX P=1/Q=0 (socket 0) -> TX P=3/Q=0 (socket 0) peer=02:00:00:00:00:03
+   RX P=3/Q=0 (socket 0) -> TX P=1/Q=0 (socket 0) peer=02:00:00:00:00:02
 
 vlan set strip
 ~~~~~~~~~~~~~~
 
-Set the VLAN strip on a port:
+Set the VLAN strip on a port::
 
-vlan set strip (on|off) (port_id)
+   testpmd> vlan set strip (on|off) (port_id)
 
 vlan set stripq
 ~~~~~~~~~~~~~~~
 
-Set the VLAN strip for a queue on a port:
+Set the VLAN strip for a queue on a port::
 
-vlan set stripq (on|off) (port_id,queue_id)
+   testpmd> vlan set stripq (on|off) (port_id,queue_id)
 
 vlan set filter
 ~~~~~~~~~~~~~~~
 
-Set the VLAN filter on a port:
+Set the VLAN filter on a port::
 
-vlan set filter (on|off) (port_id)
+   testpmd> vlan set filter (on|off) (port_id)
 
 vlan set qinq
 ~~~~~~~~~~~~~
 
-Set the VLAN QinQ (extended queue in queue) on for a port:
+Set the VLAN QinQ (extended queue in queue) on for a port::
 
-vlan set qinq (on|off) (port_id)
+   testpmd> vlan set qinq (on|off) (port_id)
 
 vlan set tpid
 ~~~~~~~~~~~~~
 
-Set the outer VLAN TPID for packet filtering on a port:
+Set the outer VLAN TPID for packet filtering on a port::
 
-vlan set tpid (value) (port_id)
+   testpmd> vlan set tpid (value) (port_id)
 
 .. note::
 
-    TPID value must be a 16-bit number (value <= 65536).
+   TPID value must be a 16-bit number (value <= 65536).
 
 rx_vlan add
 ~~~~~~~~~~~
 
-Add a VLAN ID, or all identifiers, to the set of VLAN identifiers filtered by port ID:
+Add a VLAN ID, or all identifiers, to the set of VLAN identifiers filtered by port ID::
 
-rx_vlan add (vlan_id|all) (port_id)
+   testpmd> rx_vlan add (vlan_id|all) (port_id)
 
 .. note::
 
-    VLAN filter must be set on that port. VLAN ID < 4096.
+   VLAN filter must be set on that port. VLAN ID < 4096.
+   Depending on the NIC used, number of vlan_ids may be limited to the maximum entries
+   in VFTA table. This is important if enabling all vlan_ids.
 
 rx_vlan rm
 ~~~~~~~~~~
 
-Remove a VLAN ID, or all identifiers, from the set of VLAN identifiers filtered by port ID:
-
-rx_vlan rm (vlan_id|all) (port_id)
-
-rx_vlan add(for VF)
-~~~~~~~~~~~~~~~~~~~
+Remove a VLAN ID, or all identifiers, from the set of VLAN identifiers filtered by port ID::
 
-Add a VLAN ID, to the set of VLAN identifiers filtered for VF(s) for port ID:
+   testpmd> rx_vlan rm (vlan_id|all) (port_id)
 
-rx_vlan add (vlan_id) port (port_id) vf (vf_mask)
-
-rx_vlan rm(for VF)
-~~~~~~~~~~~~~~~~~~
+rx_vlan add (for VF)
+~~~~~~~~~~~~~~~~~~~~
 
-Remove a VLAN ID, from the set of VLAN identifiers filtered for VF(s) for port ID:
+Add a VLAN ID, to the set of VLAN identifiers filtered for VF(s) for port ID::
 
-rx_vlan rm (vlan_id) port (port_id) vf (vf_mask)
+   testpmd> rx_vlan add (vlan_id) port (port_id) vf (vf_mask)
 
-tx_rate (for Queue)
+rx_vlan rm (for VF)
 ~~~~~~~~~~~~~~~~~~~
 
-Set TX rate limitation for queue of a port ID:
-
-set port (port_id) queue (queue_id) rate (rate_value)
-
-tx_rate (for VF)
-~~~~~~~~~~~~~~~~
-
-Set TX rate limitation for queues in VF of a port ID:
+Remove a VLAN ID, from the set of VLAN identifiers filtered for VF(s) for port ID::
 
-set port (port_id) vf (vf_id) rate (rate_value) queue_mask (queue_mask)
+   testpmd> rx_vlan rm (vlan_id) port (port_id) vf (vf_mask)
 
 rx_vlan set tpid
 ~~~~~~~~~~~~~~~~
 
-Set the outer VLAN TPID for packet filtering on a port:
+Set the outer VLAN TPID for packet filtering on a port::
 
-rx_vlan set tpid (value) (port_id)
+   testpmd> rx_vlan set tpid (value) (port_id)
 
 tunnel_filter add
 ~~~~~~~~~~~~~~~~~
 
-Add a tunnel filter on a port:
+Add a tunnel filter on a port::
 
-tunnel_filter add (port_id) (outer_mac) (inner_mac) (ip_addr) (inner_vlan)
- (tunnel_type) (filter_type) (tenant_id) (queue_id)
+   testpmd> tunnel_filter add (port_id) (outer_mac) (inner_mac) (ip_addr) \
           (inner_vlan) (tunnel_type) (filter_type) (tenant_id) (queue_id)
 
 tunnel_filter remove
 ~~~~~~~~~~~~~~~~~~~~
 
-Remove a tunnel filter on a port:
+Remove a tunnel filter on a port::
 
-tunnel_filter rm (port_id) (outer_mac) (inner_mac) (ip_addr) (inner_vlan)
- (tunnel_type) (filter_type) (tenant_id) (queue_id)
+   testpmd> tunnel_filter rm (port_id) (outer_mac) (inner_mac) (ip_addr) \
           (inner_vlan) (tunnel_type) (filter_type) (tenant_id) (queue_id)
 
 rx_vxlan_port add
 ~~~~~~~~~~~~~~~~~
 
-Add an UDP port for VXLAN packet filter on a port:
+Add an UDP port for VXLAN packet filter on a port::
 
-rx_vxlan_port add (udp_port) (port_id)
+   testpmd> rx_vxlan_port add (udp_port) (port_id)
 
 rx_vxlan_port remove
 ~~~~~~~~~~~~~~~~~~~~
 
-Remove an UDP port for VXLAN packet filter on a port:
+Remove an UDP port for VXLAN packet filter on a port::
 
-rx_vxlan_port rm (udp_port) (port_id)
+   testpmd> rx_vxlan_port rm (udp_port) (port_id)
 
 tx_vlan set
 ~~~~~~~~~~~
 
-Set hardware insertion of VLAN ID in packets sent on a port:
+Set hardware insertion of VLAN IDs in packets sent on a port::
+
+   testpmd> tx_vlan set (port_id) vlan_id[, vlan_id_outer]
+
+For example, set a single VLAN ID (5) insertion on port 0::
+
+   tx_vlan set 0 5
+
+Or, set double VLAN ID (inner: 2, outer: 3) insertion on port 1::
+
+   tx_vlan set 1 2 3
 
-tx_vlan set (vlan_id) (port_id)
 
 tx_vlan set pvid
 ~~~~~~~~~~~~~~~~
 
-Set port based hardware insertion of VLAN ID in pacekts sent on a port:
+Set port based hardware insertion of VLAN ID in packets sent on a port::
 
-tx_vlan set pvid (port_id) (vlan_id) (on|off)
+   testpmd> tx_vlan set pvid (port_id) (vlan_id) (on|off)
 
 tx_vlan reset
 ~~~~~~~~~~~~~
 
-Disable hardware insertion of a VLAN header in packets sent on a port:
+Disable hardware insertion of a VLAN header in packets sent on a port::
 
-tx_vlan reset (port_id)
+   testpmd> tx_vlan reset (port_id)
 
-tx_checksum set
-~~~~~~~~~~~~~~~
+csum set
+~~~~~~~~
 
 Select hardware or software calculation of the checksum when
-transmitting a packet using the csum forward engine:
-
-tx_cksum set (ip|udp|tcp|sctp|vxlan)
+transmitting a packet using the ``csum`` forwarding engine::
 
-ip|udp|tcp|sctp always concern the inner layer.
-vxlan concerns the outer IP and UDP layer (in case the packet
-is recognized as a vxlan packet by the forward engine)
-
-.. note::
+   testpmd> csum set (ip|udp|tcp|sctp|outer-ip) (hw|sw) (port_id)
 
-    Check the NIC Datasheet for hardware limits.
-
-tx_checksum show
-~~~~~~~~~~~~~~~~
+Where:
 
-Display tx checksum offload configuration:
+* ``ip|udp|tcp|sctp`` always relate to  the inner layer.
 
-tx_checksum show (port_id)
+* ``outer-ip`` relates to the outer IP layer (only for IPv4) in the case where the packet is recognized
+  as a tunnel packet by the forwarding engine (vxlan, gre and ipip are
+  supported). See also the ``csum parse-tunnel`` command.
 
-tso set
-~~~~~~~
+.. note::
 
-Enable TCP Segmentation Offload in csum forward engine:
+   Check the NIC Datasheet for hardware limits.
 
-tso set (segsize) (port_id)
+csum parse-tunnel
+~~~~~~~~~~~~~~~~~
 
-.. note::
-   Please check the NIC datasheet for HW limits
+Define how tunneled packets should be handled by the csum forward
+engine::
 
-tso show
-~~~~~~~~
+   testpmd> csum parse-tunnel (on|off) (tx_port_id)
 
-Display the status of TCP Segmentation Offload:
+If enabled, the csum forward engine will try to recognize supported
+tunnel headers (vxlan, gre, ipip).
 
-tso show (port_id)
+If disabled, treat tunnel packets as non-tunneled packets (a inner
+header is handled as a packet payload).
 
-set fwd
-~~~~~~~
+.. note::
 
-Set the packet forwarding mode:
+   The port argument is the TX port like in the ``csum set`` command.
 
-set fwd (io|mac|mac_retry|macswap|flowgen|rxonly|txonly|csum|icmpecho)
+Example:
 
-The available information categories are:
+Consider a packet in packet like the following::
 
-*   io: forwards packets "as-is" in I/O mode.
-    This is the fastest possible forwarding operation as it does not access packets data.
-    This is the default mode.
+   eth_out/ipv4_out/udp_out/vxlan/eth_in/ipv4_in/tcp_in
 
-*   mac: changes the source and the destination Ethernet addresses of packets before forwarding them.
+* If parse-tunnel is enabled, the ``ip|udp|tcp|sctp`` parameters of ``csum set``
+  command relate to the inner headers (here ``ipv4_in`` and ``tcp_in``), and the
+  ``outer-ip parameter`` relates to the outer headers (here ``ipv4_out``).
 
-*   mac_retry: same as "mac" forwarding mode, but includes retries if the destination queue is full.
+* If parse-tunnel is disabled, the ``ip|udp|tcp|sctp`` parameters of ``csum  set``
+   command relate to the outer headers, here ``ipv4_out`` and ``udp_out``.
 
-*   macswap: MAC swap forwarding mode.
-    Swaps the source and the destination Ethernet addresses of packets before forwarding them.
+csum show
+~~~~~~~~~
 
-*   flowgen: multi-flow generation mode.
-    Originates a bunch of flows (varying destination IP addresses), and terminate receive traffic.
+Display tx checksum offload configuration::
 
-*   rxonly: receives packets but doesn't transmit them.
+   testpmd> csum show (port_id)
 
-*   txonly: generates and transmits packets without receiving any.
+tso set
+~~~~~~~
 
-*   csum: changes the checksum field with HW or SW methods depending on the offload flags on the packet.
+Enable TCP Segmentation Offload (TSO) in the ``csum`` forwarding engine::
 
-*   icmpecho: receives a burst of packets, lookup for IMCP echo requests and, if any, send back ICMP echo replies.
+   testpmd> tso set (segsize) (port_id)
 
+.. note::
 
-Example:
+   Check the NIC datasheet for hardware limits.
 
-.. code-block:: console
+tso show
+~~~~~~~~
 
-    testpmd> set fwd rxonly
+Display the status of TCP Segmentation Offload::
 
-    Set rxonly packet forwarding mode
+   testpmd> tso show (port_id)
 
 mac_addr add
 ~~~~~~~~~~~~
 
-Add an alternative MAC address to a port:
+Add an alternative MAC address to a port::
 
-mac_addr add (port_id) (XX:XX:XX:XX:XX:XX)
+   testpmd> mac_addr add (port_id) (XX:XX:XX:XX:XX:XX)
 
 mac_addr remove
 ~~~~~~~~~~~~~~~
 
-Remove a MAC address from a port:
+Remove a MAC address from a port::
 
-mac_addr remove (port_id) (XX:XX:XX:XX:XX:XX)
+   testpmd> mac_addr remove (port_id) (XX:XX:XX:XX:XX:XX)
 
 mac_addr add(for VF)
 ~~~~~~~~~~~~~~~~~~~~
 
-Add an alternative MAC address for a VF to a port:
+Add an alternative MAC address for a VF to a port::
 
-mac_add add port (port_id) vf (vf_id) (XX:XX:XX:XX:XX:XX)
+   testpmd> mac_add add port (port_id) vf (vf_id) (XX:XX:XX:XX:XX:XX)
 
 set port-uta
 ~~~~~~~~~~~~
 
-Set the unicast hash filter(s) on/off for a port X:
+Set the unicast hash filter(s) on/off for a port::
 
-set port (port_id) uta (XX:XX:XX:XX:XX:XX|all) (on|off)
+   testpmd> set port (port_id) uta (XX:XX:XX:XX:XX:XX|all) (on|off)
 
 set promisc
 ~~~~~~~~~~~
 
 Set the promiscuous mode on for a port or for all ports.
-In promiscuous mode packets are not dropped if they aren't for the specified MAC address:
+In promiscuous mode packets are not dropped if they aren't for the specified MAC address::
 
-set promisc (port_id|all) (on|off)
+   testpmd> set promisc (port_id|all) (on|off)
 
 set allmulti
 ~~~~~~~~~~~~
 
-Set the allmulti mode for a port or for all ports:
+Set the allmulti mode for a port or for all ports::
 
-set allmulti (port_id|all) (on|off)
+   testpmd> set allmulti (port_id|all) (on|off)
 
 Same as the ifconfig (8) option. Controls how multicast packets are handled.
 
 set flow_ctrl rx
 ~~~~~~~~~~~~~~~~
 
-Set the link flow control parameter on a port:
+Set the link flow control parameter on a port::
 
-set flow_ctrl rx (on|off) tx (on|off) (high_water) (low_water) \
-(pause_time) (send_xon) (port_id)
+   testpmd> set flow_ctrl rx (on|off) tx (on|off) (high_water) (low_water) \
+            (pause_time) (send_xon) mac_ctrl_frame_fwd (on|off) \
+           autoneg (on|off) (port_id)
 
 Where:
 
-high_water (integer): High threshold value to trigger XOFF.
+* ``high_water`` (integer): High threshold value to trigger XOFF.
+
+* ``low_water`` (integer): Low threshold value to trigger XON.
 
-low_water (integer) : Low threshold value to trigger XON.
+* ``pause_time`` (integer): Pause quota in the Pause frame.
 
-pause_time (integer): Pause quota in the Pause frame.
+* ``send_xon`` (0/1): Send XON frame.
 
-send_xon (0/1) : Send XON frame.
+* ``mac_ctrl_frame_fwd``: Enable receiving MAC control frames.
 
-mac_ctrl_frame_fwd : Enable receiving MAC control frames
+* ``autoneg``: Change the auto-negotiation para mete.
 
 set pfc_ctrl rx
 ~~~~~~~~~~~~~~~
 
-Set the priority flow control parameter on a port:
+Set the priority flow control parameter on a port::
 
-set pfc_ctrl rx (on|off) tx (on|off) (high_water) (low_water) \ (pause_time) (priority) (port_id)
+   testpmd> set pfc_ctrl rx (on|off) tx (on|off) (high_water) (low_water) \
+            (pause_time) (priority) (port_id)
 
 Where:
 
-priority (0-7): VLAN User Priority.
+* ``high_water`` (integer): High threshold value.
+
+* ``low_water`` (integer): Low threshold value.
+
+* ``pause_time`` (integer): Pause quota in the Pause frame.
+
+* ``priority`` (0-7): VLAN User Priority.
 
 set stat_qmap
 ~~~~~~~~~~~~~
 
-Set statistics mapping (qmapping 0..15) for RX/TX queue on port:
-
-set stat_qmap (tx|rx) (port_id) (queue_id) (qmapping)
+Set statistics mapping (qmapping 0..15) for RX/TX queue on port::
 
-For example, to set rx queue 2 on port 0 to mapping 5:
+   testpmd> set stat_qmap (tx|rx) (port_id) (queue_id) (qmapping)
 
-.. code-block:: console
+For example, to set rx queue 2 on port 0 to mapping 5::
 
-     testpmd>set stat_qmap rx 0 2 5
+   testpmd>set stat_qmap rx 0 2 5
 
-set port - rx/tx(for VF)
-~~~~~~~~~~~~~~~~~~~~~~~~
+set port - rx/tx (for VF)
+~~~~~~~~~~~~~~~~~~~~~~~~~
 
-Set VF receive/transmit from a port:
+Set VF receive/transmit from a port::
 
-set port (port_id) vf (vf_id) (rx|tx) (on|off)
+   testpmd> set port (port_id) vf (vf_id) (rx|tx) (on|off)
 
 set port - mac address filter (for VF)
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 
-Add/Remove unicast or multicast MAC addr filter for a VF:
+Add/Remove unicast or multicast MAC addr filter for a VF::
 
-set port (port_id) vf (vf_id) (mac_addr)
- (exact-mac|exact-mac-vlan|hashmac|hashmac-vlan) (on|off)
+   testpmd> set port (port_id) vf (vf_id) (mac_addr) \
           (exact-mac|exact-mac-vlan|hashmac|hashmac-vlan) (on|off)
 
 set port - rx mode(for VF)
 ~~~~~~~~~~~~~~~~~~~~~~~~~~
 
-Set the VF receive mode of a port:
+Set the VF receive mode of a port::
 
-set port (port_id) vf (vf_id) rxmode (AUPE|ROPE|BAM|MPE) (on|off)
+   testpmd> set port (port_id) vf (vf_id) \
+            rxmode (AUPE|ROPE|BAM|MPE) (on|off)
 
 The available receive modes are:
 
-*  AUPE: accepts untagged VLAN.
+* ``AUPE``: Accepts untagged VLAN.
+
+* ``ROPE``: Accepts unicast hash.
+
+* ``BAM``: Accepts broadcast packets.
+
+* ``MPE``: Accepts all multicast packets.
+
+set port - tx_rate (for Queue)
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 
-*  ROPE: accepts unicast hash.
+Set TX rate limitation for a queue on a port::
 
-*  BAM: accepts broadcast packets
+   testpmd> set port (port_id) queue (queue_id) rate (rate_value)
 
-*  MPE: accepts all multicast packets
+set port - tx_rate (for VF)
+~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+Set TX rate limitation for queues in VF on a port::
+
+   testpmd> set port (port_id) vf (vf_id) rate (rate_value) queue_mask (queue_mask)
 
 set port - mirror rule
 ~~~~~~~~~~~~~~~~~~~~~~
 
-Set port or vlan type mirror rule for a port.
+Set pool or vlan type mirror rule for a port::
 
-set port (port_id) mirror-rule (rule_id) (pool-mirror|vlan-mirror) (poolmask|vlanid[,vlanid]*) dst-pool (pool_id) (on|off)
+   testpmd> set port (port_id) mirror-rule (rule_id) \
+            (pool-mirror-up|pool-mirror-down|vlan-mirror) \
+            (poolmask|vlanid[,vlanid]*) dst-pool (pool_id) (on|off)
 
-For example to enable mirror traffic with vlan 0,1 to pool 0:
+Set link mirror rule for a port::
 
-.. code-block:: console
+   testpmd> set port (port_id) mirror-rule (rule_id) \
+           (uplink-mirror|downlink-mirror) dst-pool (pool_id) (on|off)
+
+For example to enable mirror traffic with vlan 0,1 to pool 0::
 
-    set port 0 mirror-rule 0 vlan-mirror 0,1 dst-pool 0 on
+   set port 0 mirror-rule 0 vlan-mirror 0,1 dst-pool 0 on
 
 reset port - mirror rule
 ~~~~~~~~~~~~~~~~~~~~~~~~
 
-Reset a mirror rule for a port.
+Reset a mirror rule for a port::
 
-reset port (port_id) mirror-rule (rule_id)
+   testpmd> reset port (port_id) mirror-rule (rule_id)
 
 set flush_rx
 ~~~~~~~~~~~~
 
-Flush (default) or don't flush RX streams before forwarding.
-Mainly used with PCAP drivers to avoid the default behavior of flushing the first 512 packets on RX streams.
+Set the flush on RX streams before forwarding.
+The default is flush ``on``.
+Mainly used with PCAP drivers to turn off the default behavior of flushing the first 512 packets on RX streams::
 
-set flush_rx off
+   testpmd> set flush_rx off
 
 set bypass mode
 ~~~~~~~~~~~~~~~
 
-Set the bypass mode for the lowest port on bypass enabled NIC.
+Set the bypass mode for the lowest port on bypass enabled NIC::
 
-set bypass mode (normal|bypass|isolate) (port_id)
+   testpmd> set bypass mode (normal|bypass|isolate) (port_id)
 
 set bypass event
 ~~~~~~~~~~~~~~~~
 
-Set the event required to initiate specified bypass mode for the lowest port on a bypass enabled NIC where:
+Set the event required to initiate specified bypass mode for the lowest port on a bypass enabled::
+
+   testpmd> set bypass event (timeout|os_on|os_off|power_on|power_off) \
+            mode (normal|bypass|isolate) (port_id)
+
+Where:
 
-*   timeout: enable bypass after watchdog timeout.
+* ``timeout``: Enable bypass after watchdog timeout.
 
-*   os_on: enable bypass when OS/board is powered on.
+* ``os_on``: Enable bypass when OS/board is powered on.
 
-*   os_off: enable bypass when OS/board is powered off.
+* ``os_off``: Enable bypass when OS/board is powered off.
 
-*   power_on: enable bypass when power supply is turned on.
+* ``power_on``: Enable bypass when power supply is turned on.
 
-*   power_off: enable bypass when power supply is turned off.
+* ``power_off``: Enable bypass when power supply is turned off.
 
-set bypass event (timeout|os_on|os_off|power_on|power_off) mode (normal|bypass|isolate) (port_id)
 
 set bypass timeout
 ~~~~~~~~~~~~~~~~~~
 
-Set the bypass watchdog timeout to 'n' seconds where 0 = instant.
+Set the bypass watchdog timeout to ``n`` seconds where 0 = instant::
 
-set bypass timeout (0|1.5|2|3|4|8|16|32)
+   testpmd> set bypass timeout (0|1.5|2|3|4|8|16|32)
 
 show bypass config
 ~~~~~~~~~~~~~~~~~~
 
-Show the bypass configuration for a bypass enabled NIC using the lowest port on the NIC.
-
-show bypass config (port_id)
-
-add_ethertype_filter
-~~~~~~~~~~~~~~~~~~~~
-
-Add a L2 Ethertype filter, which identify packets by their L2 Ethertype mainly assign them to a receive queue.
-
-add_ethertype_filter (port_id) ethertype (eth_value) priority (enable|disable) (pri_value) queue (queue_id) index (idx)
-
-The available information parameters are:
+Show the bypass configuration for a bypass enabled NIC using the lowest port on the NIC::
 
-*   port_id:  the port which the Ethertype filter assigned on.
+   testpmd> show bypass config (port_id)
 
-*   eth_value: the EtherType value want to match,
-    for example 0x0806 for ARP packet. 0x0800 (IPv4) and 0x86DD (IPv6) are invalid.
+set link up
+~~~~~~~~~~~
 
-*   enable: user priority participates in the match.
+Set link up for a port::
 
-*   disable: user priority doesn't participate in the match.
+   testpmd> set link-up port (port id)
 
-*   pri_value: user priority value that want to match.
+set link down
+~~~~~~~~~~~~~
 
-*   queue_id : The receive queue associated with this EtherType filter
+Set link down for a port::
 
-*   index: the index of this EtherType filter
+   testpmd> set link-down port (port id)
 
-Example:
 
-.. code-block:: console
-
-    testpmd> add_ethertype_filter 0 ethertype 0x0806 priority disable 0 queue 3 index 0
-    Assign ARP packet to receive queue 3
+Port Functions
+--------------
 
-remove_ethertype_filter
-~~~~~~~~~~~~~~~~~~~~~~~
+The following sections show functions for configuring ports.
 
-Remove a L2 Ethertype filter
+.. note::
 
-remove_ethertype_filter (port_id) index (idx)
+   Port configuration changes only become active when forwarding is started/restarted.
 
-get_ethertype_filter
-~~~~~~~~~~~~~~~~~~~~
+port attach
+~~~~~~~~~~~
 
-Get and display a L2 Ethertype filter
+Attach a port specified by pci address or virtual device args.
 
-get_ethertype_filter (port_id) index (idx)
+To attach a new pci device, the device should be recognized by kernel first.
+Then it should be moved under DPDK management.
+Finally the port can be attached to testpmd.
 
-Example:
+For example, to move a pci device using ixgbe under DPDK management:
 
 .. code-block:: console
 
-    testpmd> get_ethertype_filter 0 index 0
+   # Check the status of the available devices.
+   ./tools/dpdk_nic_bind.py --status
 
-    filter[0]:
-        ethertype: 0x0806
-        priority: disable, 0
-        queue: 3
+   Network devices using DPDK-compatible driver
+   ============================================
+   <none>
 
-add_2tuple_filter
-~~~~~~~~~~~~~~~~~
+   Network devices using kernel driver
+   ===================================
+   0000:0a:00.0 '82599ES 10-Gigabit' if=eth2 drv=ixgbe unused=
 
-Add a 2-tuple filter,
-which identify packets by specific protocol and destination TCP/UDP port
-and forwards packets into one of the receive queues.
-
-add_2tuple_filter (port_id) protocol (pro_value) (pro_mask) dst_port (port_value) (port_mask)
-flags (flg_value) priority (prio_value) queue (queue_id) index (idx)
-
-The available information parameters are:
 
-*   port_id: the port which the 2-tuple filter assigned on.
+   # Bind the device to igb_uio.
+   sudo ./tools/dpdk_nic_bind.py -b igb_uio 0000:0a:00.0
 
-*   pro_value: IP L4 protocol
 
-*   pro_mask: protocol participates in the match or not, 1 means participate
+   # Recheck the status of the devices.
+   ./tools/dpdk_nic_bind.py --status
+   Network devices using DPDK-compatible driver
+   ============================================
+   0000:0a:00.0 '82599ES 10-Gigabit' drv=igb_uio unused=
 
-*   port_value: destination port in L4.
+To attach a port created by virtual device, above steps are not needed.
 
-*   port_mask: destination port participates in the match or not, 1 means participate.
+port attach (identifier)
 
-*   flg_value: TCP control bits. The non-zero value is invalid, when the pro_value is not set to 0x06 (TCP).
-
-*   prio_value: the priority of this filter.
-
-*   queue_id: The receive queue associated with this 2-tuple filter
-
-*   index: the index of this 2-tuple filter
-
-Example:
+For example, to attach a port whose pci address is 0000:0a:00.0.
 
 .. code-block:: console
 
-    testpmd> add_2tuple_filter 0 protocol 0x06 1 dst_port 32 1 flags 0x02 priority 3 queue 3 index 0
-
-remove_2tuple_filter
-~~~~~~~~~~~~~~~~~~~~
-
-Remove a 2-tuple filter
+   testpmd> port attach 0000:0a:00.0
+   Attaching a new port...
+   EAL: PCI device 0000:0a:00.0 on NUMA socket -1
+   EAL:   probe driver: 8086:10fb rte_ixgbe_pmd
+   EAL:   PCI memory mapped at 0x7f83bfa00000
+   EAL:   PCI memory mapped at 0x7f83bfa80000
+   PMD: eth_ixgbe_dev_init(): MAC: 2, PHY: 18, SFP+: 5
+   PMD: eth_ixgbe_dev_init(): port 0 vendorID=0x8086 deviceID=0x10fb
+   Port 0 is attached. Now total ports is 1
+   Done
 
-remove_2tuple_filter (port_id) index (idx)
-
-get_2tuple_filter
-~~~~~~~~~~~~~~~~~
-
-Get and display a 2-tuple filter
-
-get_2tuple_filter (port_id) index (idx)
-
-Example:
+For example, to attach a port created by pcap PMD.
 
 .. code-block:: console
 
-    testpmd> get_2tuple_filter 0 index 0
-
-    filter[0]:
-        Destination Port: 0x0020 mask: 1
-        protocol: 0x06 mask:1 tcp_flags: 0x02
-        priority: 3   queue: 3
-
-add_5tuple_filter
-~~~~~~~~~~~~~~~~~
+   testpmd> port attach eth_pcap0
+   Attaching a new port...
+   PMD: Initializing pmd_pcap for eth_pcap0
+   PMD: Creating pcap-backed ethdev on numa socket 0
+   Port 0 is attached. Now total ports is 1
+   Done
 
-Add a 5-tuple filter,
-which consists of a 5-tuple (protocol, source and destination IP addresses, source and destination TCP/UDP/SCTP port)
-and routes packets into one of the receive queues.
+In this case, identifier is ``eth_pcap0``.
+This identifier format is the same as ``--vdev`` format of DPDK applications.
 
-add_5tuple_filter (port_id) dst_ip (dst_address) src_ip (src_address) dst_port (dst_port_value) src_port (src_port_value)
-protocol (protocol_value) mask (mask_value) flags (flags_value) priority (prio_value) queue (queue_id) index (idx)
+For example, to re-attach a bonded port which has been previously detached,
+the mode and slave parameters must be given.
 
-The available information parameters are:
+.. code-block:: console
 
-*   port_id: the port which the 5-tuple filter assigned on.
+   testpmd> port attach eth_bond_0,mode=0,slave=1
+   Attaching a new port...
+   EAL: Initializing pmd_bond for eth_bond_0
+   EAL: Create bonded device eth_bond_0 on port 0 in mode 0 on socket 0.
+   Port 0 is attached. Now total ports is 1
+   Done
 
-*   dst_address: destination IP address.
 
-*   src_address: source IP address.
+port detach
+~~~~~~~~~~~
 
-*   dst_port_value: TCP/UDP destination port.
+Detach a specific port.
 
-*   src_port_value: TCP/UDP source port.
+Before detaching a port, the port should be closed::
 
-*   protocol_value: L4 protocol.
+   testpmd> port detach (port_id)
 
-*   mask_value: participates in the match or not by bit for field above, 1b means participate
+For example, to detach a pci device port 0.
 
-*   flags_value: TCP control bits. The non-zero value is invalid, when the protocol_value is not set to 0x06 (TCP).
+.. code-block:: console
 
-*   prio_value: the priority of this filter.
+   testpmd> port close 0
+   Closing ports...
+   Done
 
-*   queue_id: The receive queue associated with this 5-tuple filter.
+   testpmd> port detach 0
+   Detaching a port...
+   EAL: PCI device 0000:0a:00.0 on NUMA socket -1
+   EAL:   remove driver: 8086:10fb rte_ixgbe_pmd
+   EAL:   PCI memory unmapped at 0x7f83bfa00000
+   EAL:   PCI memory unmapped at 0x7f83bfa80000
+   Done
 
-*   index: the index of this 5-tuple filter
 
-Example:
+For example, to detach a virtual device port 0.
 
 .. code-block:: console
 
-    testpmd> add_5tuple_filter 1 dst_ip 2.2.2.5 src_ip 2.2.2.4 dst_port 64 src_port 32 protocol 0x06 mask 0x1F flags 0x0 priority 3 queue 3 index 0
+   testpmd> port close 0
+   Closing ports...
+   Done
 
-remove_5tuple_filter
-~~~~~~~~~~~~~~~~~~~~
-
-Remove a 5-tuple filter
+   testpmd> port detach 0
+   Detaching a port...
+   PMD: Closing pcap ethdev on numa socket 0
+   Port 'eth_pcap0' is detached. Now total ports is 0
+   Done
 
-remove_5tuple_filter (port_id) index (idx)
+To remove a pci device completely from the system, first detach the port from testpmd.
+Then the device should be moved under kernel management.
+Finally the device can be removed using kernel pci hotplug functionality.
 
-get_5tuple_filter
-~~~~~~~~~~~~~~~~~
-
-Get and display a 5-tuple filter
-
-get_5tuple_filter (port_id) index (idx)
-
-Example:
+For example, to move a pci device under kernel management:
 
 .. code-block:: console
 
-    testpmd> get_5tuple_filter 1 index 0
+   sudo ./tools/dpdk_nic_bind.py -b ixgbe 0000:0a:00.0
 
-    filter[0]:
-        Destination IP: 0x02020205 mask: 1
-        Source IP: 0x02020204 mask: 1
-        Destination Port: 0x0040 mask: 1
-        Source Port: 0x0020 mask: 1
-        protocol: 0x06 mask: 1
-        priority: 3 flags: 0x00 queue: 3
+   ./tools/dpdk_nic_bind.py --status
 
-add_syn_filter
-~~~~~~~~~~~~~~
+   Network devices using DPDK-compatible driver
+   ============================================
+   <none>
 
-Add SYN filter, which can forward TCP packets whose *SYN* flag is set into a separate queue.
+   Network devices using kernel driver
+   ===================================
+   0000:0a:00.0 '82599ES 10-Gigabit' if=eth2 drv=ixgbe unused=igb_uio
 
-add_syn_filter (port_id) priority (high|low) queue (queue_id)
+To remove a port created by a virtual device, above steps are not needed.
 
-The available information parameters are:
+port start
+~~~~~~~~~~
 
-*   port_id: the port which the SYN filter assigned on.
+Start all ports or a specific port::
 
-*   high: this SYN filter has higher priority than other filters.
+   testpmd> port start (port_id|all)
 
-*   low: this SYN filter has lower priority than other filters.
+port stop
+~~~~~~~~~
 
-*   queue_id: The receive queue associated with this SYN filter
+Stop all ports or a specific port::
 
-Example:
+   testpmd> port stop (port_id|all)
 
-.. code-block:: console
+port close
+~~~~~~~~~~
 
-    testpmd> add_syn_filter 0 priority high queue 3,
+Close all ports or a specific port::
 
-remove_syn_filter
-~~~~~~~~~~~~~~~~~
+   testpmd> port close (port_id|all)
+
+port start/stop queue
+~~~~~~~~~~~~~~~~~~~~~
 
-Remove SYN filter
+Start/stop a rx/tx queue on a specific port::
 
-remove_syn_filter (port_id)
+   testpmd> port (port_id) (rxq|txq) (queue_id) (start|stop)
 
-get_syn_filter
-~~~~~~~~~~~~~~
+Only take effect when port is started.
 
-Get and display SYN filter
+port config - speed
+~~~~~~~~~~~~~~~~~~~
 
-get_syn_filter (port_id)
+Set the speed and duplex mode for all ports or a specific port::
 
-Example:
+   testpmd> port config (port_id|all) speed (10|100|1000|10000|auto) \
+            duplex (half|full|auto)
 
-.. code-block:: console
+port config - queues/descriptors
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 
-    testpmd> get_syn_filter 0
+Set number of queues/descriptors for rxq, txq, rxd and txd::
 
-    syn filter: on, priority: high, queue: 3
+   testpmd> port config all (rxq|txq|rxd|txd) (value)
 
-add_flex_filter
-~~~~~~~~~~~~~~~
+This is equivalent to the ``--rxq``, ``--txq``, ``--rxd`` and ``--txd`` command-line options.
 
-Add a Flex filter,
-which recognizes any arbitrary pattern within the first 128 bytes of the packet
-and routes packets into one of the receive queues.
+port config - max-pkt-len
+~~~~~~~~~~~~~~~~~~~~~~~~~
 
-add_flex_filter (port_id) len (len_value) bytes (bytes_string) mask (mask_value)
-priority (prio_value) queue (queue_id) index (idx)
+Set the maximum packet length::
 
-The available information parameters are:
+   testpmd> port config all max-pkt-len (value)
 
-*   port_id: the port which the Flex filter assigned on.
+This is equivalent to the ``--max-pkt-len`` command-line option.
 
-*   len_value: filter length in byte, no greater than 128.
+port config - CRC Strip
+~~~~~~~~~~~~~~~~~~~~~~~
 
-*   bytes_string: a sting in format of octal, means the value the flex filter need to match.
+Set hardware CRC stripping on or off for all ports::
 
-*   mask_value: a sting in format of octal, bit 1 means corresponding byte in DWORD participates in the match.
+   testpmd> port config all crc-strip (on|off)
 
-*   prio_value: the priority of this filter.
+CRC stripping is off by default.
 
-*   queue_id: The receive queue associated with this Flex filter.
+The ``on`` option is equivalent to the ``--crc-strip`` command-line option.
 
-*   index: the index of this Flex filter
+port config - RX Checksum
+~~~~~~~~~~~~~~~~~~~~~~~~~
 
-Example:
+Set hardware RX checksum offload to on or off for all ports::
 
-.. code-block:: console
+   testpmd> port config all rx-cksum (on|off)
 
-   testpmd> add_flex_filter 0 len 16 bytes 0x00000000000000000000000008060000 mask 000C priority 3 queue 3 index 0
+Checksum offload is off by default.
 
-Assign a packet whose 13th and 14th bytes are 0x0806 to queue 3.
+The ``on`` option is equivalent to the ``--enable-rx-cksum`` command-line option.
 
-remove_flex_filter
+port config - VLAN
 ~~~~~~~~~~~~~~~~~~
 
-Remove a Flex filter
+Set hardware VLAN on or off for all ports::
 
-remove_flex_filter (port_id) index (idx)
+   testpmd> port config all hw-vlan (on|off)
 
-get_flex_filter
-~~~~~~~~~~~~~~~
+Hardware VLAN is on by default.
 
-Get and display a Flex filter
+The ``off`` option is equivalent to the ``--disable-hw-vlan`` command-line option.
 
-get_flex_filter (port_id) index (idx)
+port config - VLAN filter
+~~~~~~~~~~~~~~~~~~~~~~~~~
 
-Example:
+Set hardware VLAN filter on or off for all ports::
 
-.. code-block:: console
+   testpmd> port config all hw-vlan-filter (on|off)
 
-    testpmd> get_flex_filter 0 index 0
+Hardware VLAN filter is on by default.
 
-    filter[0]:
+The ``off`` option is equivalent to the ``--disable-hw-vlan-filter`` command-line option.
 
-        length: 16
+port config - VLAN strip
+~~~~~~~~~~~~~~~~~~~~~~~~
 
-        dword[]: 0x00000000 00000000 00000000 08060000 00000000 00000000 00000000
-    00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
-    00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
-    00000000 00000000 00000000 00000000 00000000 00000000 00000000
+Set hardware VLAN strip on or off for all ports::
 
-        mask[]:
-    0b0000000000001100000000000000000000000000000000000000000000000000000000
-    0000000000000000000000000000000000000000000000000000000000
+   testpmd> port config all hw-vlan-strip (on|off)
 
-        priority: 3   queue: 3
+Hardware VLAN strip is on by default.
 
-set link up
-~~~~~~~~~~~
+The ``off`` option is equivalent to the ``--disable-hw-vlan-strip`` command-line option.
 
-Set link up for a port.
+port config - VLAN extend
+~~~~~~~~~~~~~~~~~~~~~~~~~
 
-set link-up port (port id)
+Set hardware VLAN extend on or off for all ports::
 
-set link down
-~~~~~~~~~~~~~
+   testpmd> port config all hw-vlan-extend (on|off)
 
-Set link down for a port.
+Hardware VLAN extend is off by default.
 
-set link-down port (port id)
+The ``off`` option is equivalent to the ``--disable-hw-vlan-extend`` command-line option.
 
-Port Functions
---------------
+port config - Drop Packets
+~~~~~~~~~~~~~~~~~~~~~~~~~~
 
-The following sections show functions for configuring ports.
+Set packet drop for packets with no descriptors on or off for all ports::
 
-.. note::
+   testpmd> port config all drop-en (on|off)
 
-    Port configuration changes only become active when forwarding is started/restarted.
+Packet dropping for packets with no descriptors is off by default.
 
-port start
-~~~~~~~~~~
+The ``on`` option is equivalent to the ``--enable-drop-en`` command-line option.
 
-Start all ports or a specific port:
+port config - RSS
+~~~~~~~~~~~~~~~~~
 
-port start (port_id|all)
+Set the RSS (Receive Side Scaling) mode on or off::
 
-port stop
-~~~~~~~~~
+   testpmd> port config all rss (all|ip|tcp|udp|sctp|ether|none)
 
-Stop all ports or a specific port:
+RSS is on by default.
 
-port stop (port_id|all)
+The ``none`` option is equivalent to the ``--disable-rss`` command-line option.
 
-port close
-~~~~~~~~~~
+port config - RSS Reta
+~~~~~~~~~~~~~~~~~~~~~~
 
-Close all ports or a specific port:
+Set the RSS (Receive Side Scaling) redirection table::
 
-port close (port_id|all)
+   testpmd> port config all rss reta (hash,queue)[,(hash,queue)]
 
-port start/stop queue
-~~~~~~~~~~~~~~~~~~~~~
+port config - DCB
+~~~~~~~~~~~~~~~~~
 
-Start/stop a rx/tx queue on a specific port:
+Set the DCB mode for an individual port::
 
-port (port_id) (rxq|txq) (queue_id) (start|stop)
+   testpmd> port config (port_id) dcb vt (on|off) (traffic_class) pfc (on|off)
 
-Only take effect when port is started.
+The traffic class should be 4 or 8.
 
-port config - speed
+port config - Burst
 ~~~~~~~~~~~~~~~~~~~
 
-Set the speed and duplex mode for all ports or a specific port:
+Set the number of packets per burst::
 
-port config (port_id|all) speed (10|100|1000|10000|auto) duplex (half|full|auto)
+   testpmd> port config all burst (value)
 
-port config - queues/descriptors
-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+This is equivalent to the ``--burst`` command-line option.
 
-Set number of queues/descriptors for rxq, txq, rxd and txd:
-
-port config all (rxq|txq|rxd|txd) (value)
+port config - Threshold
+~~~~~~~~~~~~~~~~~~~~~~~
 
-This is equivalent to the --rxq, --txq, --rxd and --txd command-line options.
+Set thresholds for TX/RX queues::
 
-port config - max-pkt-len
-~~~~~~~~~~~~~~~~~~~~~~~~~
+   testpmd> port config all (threshold) (value)
 
-Set the maximum packet length:
+Where the threshold type can be:
 
-port config all max-pkt-len (value)
+* ``txpt:`` Set the prefetch threshold register of the TX rings, 0 <= value <= 255.
 
-This is equivalent to the --max-pkt-len command-line option.
+* ``txht:`` Set the host threshold register of the TX rings, 0 <= value <= 255.
 
-port config - CRC Strip
-~~~~~~~~~~~~~~~~~~~~~~~
+* ``txwt:`` Set the write-back threshold register of the TX rings, 0 <= value <= 255.
 
-Set hardware CRC stripping on or off for all ports:
+* ``rxpt:`` Set the prefetch threshold register of the RX rings, 0 <= value <= 255.
 
-port config all crc-strip (on|off)
+* ``rxht:`` Set the host threshold register of the RX rings, 0 <= value <= 255.
 
-CRC stripping is off by default.
+* ``rxwt:`` Set the write-back threshold register of the RX rings, 0 <= value <= 255.
 
-The on option is equivalent to the --crc-strip command-line option.
+* ``txfreet:`` Set the transmit free threshold of the TX rings, 0 <= value <= txd.
 
-port config - RX Checksum
-~~~~~~~~~~~~~~~~~~~~~~~~~
+* ``rxfreet:`` Set the transmit free threshold of the RX rings, 0 <= value <= rxd.
 
-Set hardware RX checksum offload to on or off for all ports:
+* ``txrst:`` Set the transmit RS bit threshold of TX rings, 0 <= value <= txd.
 
-port config all rx-cksum (on|off)
+These threshold options are also available from the command-line.
 
-Checksum offload is off by default.
 
-The on option is equivalent to the --enable-rx-cksum command-line option.
+Link Bonding Functions
+----------------------
 
-port config - VLAN
-~~~~~~~~~~~~~~~~~~
+The Link Bonding functions make it possible to dynamically create and
+manage link bonding devices from within testpmd interactive prompt.
 
-Set hardware VLAN on or off for all ports:
+create bonded device
+~~~~~~~~~~~~~~~~~~~~
 
-port config all hw-vlan (on|off)
+Create a new bonding device::
 
-Hardware VLAN is on by default.
+   testpmd> create bonded device (mode) (socket)
 
-The off option is equivalent to the --disable-hw-vlan command-line option.
+For example, to create a bonded device in mode 1 on socket 0::
 
-port config - Drop Packets
-~~~~~~~~~~~~~~~~~~~~~~~~~~
+   testpmd> create bonded 1 0
+   created new bonded device (port X)
 
-Set packet drop for packets with no descriptors on or off for all ports:
+add bonding slave
+~~~~~~~~~~~~~~~~~
 
-port config all drop-en (on|off)
+Adds Ethernet device to a Link Bonding device::
 
-Packet dropping for packets with no descriptors is off by default.
+   testpmd> add bonding slave (slave id) (port id)
 
-The on option is equivalent to the --enable-drop-en command-line option.
+For example, to add Ethernet device (port 6) to a Link Bonding device (port 10)::
 
-port config - RSS
-~~~~~~~~~~~~~~~~~
+   testpmd> add bonding slave 6 10
 
-Set the RSS (Receive Side Scaling) mode on or off:
 
-port config all rss (ip|udp|none)
+remove bonding slave
+~~~~~~~~~~~~~~~~~~~~
 
-RSS is on by default.
+Removes an Ethernet slave device from a Link Bonding device::
 
-The off option is equivalent to the --disable-rss command-line option.
+   testpmd> remove bonding slave (slave id) (port id)
 
-port config - RSS Reta
-~~~~~~~~~~~~~~~~~~~~~~
+For example, to remove Ethernet slave device (port 6) to a Link Bonding device (port 10)::
 
-Set the RSS (Receive Side Scaling) redirection table:
+   testpmd> remove bonding slave 6 10
 
-port config all rss reta (hash,queue)[,(hash,queue)]
+set bonding mode
+~~~~~~~~~~~~~~~~
 
-port config - DCB
-~~~~~~~~~~~~~~~~~
+Set the Link Bonding mode of a Link Bonding device::
 
-Set the DCB mode for an individual port:
+   testpmd> set bonding mode (value) (port id)
 
-port config (port_id) dcb vt (on|off) (traffic_class) pfc (on|off)
+For example, to set the bonding mode of a Link Bonding device (port 10) to broadcast (mode 3)::
 
-The traffic class should be 4 or 8.
+   testpmd> set bonding mode 3 10
 
-port config - Burst
+set bonding primary
 ~~~~~~~~~~~~~~~~~~~
 
-Set the number of packets per burst:
-
-port config all burst (value)
-
-This is equivalent to the --burst command-line option.
+Set an Ethernet slave device as the primary device on a Link Bonding device::
 
-port config - Threshold
-~~~~~~~~~~~~~~~~~~~~~~~
+   testpmd> set bonding primary (slave id) (port id)
 
-Set thresholds for TX/RX queues:
+For example, to set the Ethernet slave device (port 6) as the primary port of a Link Bonding device (port 10)::
 
-port config all (threshold) (value)
+   testpmd> set bonding primary 6 10
 
-Where the threshold type can be:
+set bonding mac
+~~~~~~~~~~~~~~~
 
-*   txpt: Set the prefetch threshold register of the TX rings, 0 <= value <= 255.
+Set the MAC address of a Link Bonding device::
 
-*   txht: Set the host threshold register of the TX rings, 0 <= value <= 255.
+   testpmd> set bonding mac (port id) (mac)
 
-*   txwt: Set the write-back threshold register of the TX rings, 0 <= value <= 255.
+For example, to set the MAC address of a Link Bonding device (port 10) to 00:00:00:00:00:01::
 
-*   rxpt: Set the prefetch threshold register of the RX rings, 0 <= value <= 255.
+   testpmd> set bonding mac 10 00:00:00:00:00:01
 
-*   rxht: Set the host threshold register of the RX rings, 0 <= value <= 255.
+set bonding xmit_balance_policy
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 
-*   rxwt: Set the write-back threshold register of the RX rings, 0 <= value <= 255.
+Set the transmission policy for a Link Bonding device when it is in Balance XOR mode::
 
-*   txfreet: Set the transmit free threshold of the TX rings, 0 <= value <= txd.
+   testpmd> set bonding xmit_balance_policy (port_id) (l2|l23|l34)
 
-*   rxfreet: Set the transmit free threshold of the RX rings, 0 <= value <= rxd.
+For example, set a Link Bonding device (port 10) to use a balance policy of layer 3+4 (IP addresses & UDP ports)::
 
-*   txrst: Set the transmit RS bit threshold of TX rings, 0 <= value <= txd.
-    These threshold options are also available from the command-line.
+   testpmd> set bonding xmit_balance_policy 10 l34
 
-Flow Director Functions
------------------------
 
-The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
+set bonding mon_period
+~~~~~~~~~~~~~~~~~~~~~~
 
-Two types of filtering are supported which are referred to as Perfect Match and Signature filters:
+Set the link status monitoring polling period in milliseconds for a bonding device.
 
-*   Perfect match filters.
-    The hardware checks a match between the masked fields of the received packets and the programmed filters.
+This adds support for PMD slave devices which do not support link status interrupts.
+When the mon_period is set to a value greater than 0 then all PMD's which do not support
+link status ISR will be queried every polling interval to check if their link status has changed::
 
-*   Signature filters.
-    The hardware checks a match between a hash-based signature of the masked fields of the received packet.
+   testpmd> set bonding mon_period (port_id) (value)
 
-The Flow Director filters can match the following fields in a packet:
+For example, to set the link status monitoring polling period of bonded device (port 5) to 150ms::
 
-*   Source IP and destination IP addresses.
+   testpmd> set bonding mon_period 5 150
 
-*   Source port and destination port numbers (for UDP and TCP packets).
 
-*   IPv4/IPv6 and UDP/ TCP/SCTP protocol match.
+show bonding config
+~~~~~~~~~~~~~~~~~~~
 
-*   VLAN header.
+Show the current configuration of a Link Bonding device::
 
-*   Flexible 2-byte tuple match anywhere in the first 64 bytes of the packet.
+   testpmd> show bonding config (port id)
 
-The Flow Director can also mask out parts of all of these fields so that filters are only applied to certain fields
-or parts of the fields.
-For example it is possible to mask out sub-nets of IP addresses or to ignore VLAN headers.
+For example,
+to show the configuration a Link Bonding device (port 9) with 3 slave devices (1, 3, 4)
+in balance mode with a transmission policy of layer 2+3::
 
-In the following sections, several common parameters are used in the Flow Director filters.
-These are explained below:
+   testpmd> show bonding config 9
+        Bonding mode: 2
+        Balance Xmit Policy: BALANCE_XMIT_POLICY_LAYER23
+        Slaves (3): [1 3 4]
+        Active Slaves (3): [1 3 4]
+        Primary: [3]
 
-*   src: A pair of source address values. The source IP, in IPv4 or IPv6 format, and the source port:
 
-    src 192.168.0.1 1024
+Register Functions
+------------------
 
-    src 2001:DB8:85A3:0:0:8A2E:370:7000 1024
+The Register Functions can be used to read from and write to registers on the network card referenced by a port number.
+This is mainly useful for debugging purposes.
+Reference should be made to the appropriate datasheet for the network card for details on the register addresses
+and fields that can be accessed.
 
-*   dst: A pair of destination address values. The destination IP, in IPv4 or IPv6 format, and the destination port.
+read reg
+~~~~~~~~
 
-*   flexbytes: A 2-byte tuple to be matched within the first 64 bytes of a packet.
+Display the value of a port register::
 
-The offset where the match occurs is set by the --pkt-filter-flexbytes-offset command-line parameter
-and is counted from the first byte of the destination Ethernet MAC address.
-The default offset is 0xC bytes, which is the "Type" word in the MAC header.
-Typically, the flexbyte value is set to 0x0800 to match the IPv4 MAC type or 0x86DD to match IPv6.
-These values change when a VLAN tag is added.
+   testpmd> read reg (port_id) (address)
 
-*   vlan: The VLAN header to match in the packet.
+For example, to examine the Flow Director control register (FDIRCTL, 0x0000EE000) on an Intel 82599 10 GbE Controller::
 
-*   queue: The index of the RX queue to route matched packets to.
+   testpmd> read reg 0 0xEE00
+   port 0 PCI register at offset 0xEE00: 0x4A060029 (1241907241)
 
-*   soft: The 16-bit value in the MBUF flow director ID field for RX packets matching the filter.
+read regfield
+~~~~~~~~~~~~~
 
-add_signature_filter
-~~~~~~~~~~~~~~~~~~~~
+Display a port register bit field::
 
-Add a signature filter:
+   testpmd> read regfield (port_id) (address) (bit_x) (bit_y)
 
-# Command is displayed on several lines for clarity.
+For example, reading the lowest two bits from the register in the example above::
 
-add_signature_filter (port_id) (ip|udp|tcp|sctp)
+   testpmd> read regfield 0 0xEE00 0 1
+   port 0 PCI register at offset 0xEE00: bits[0, 1]=0x1 (1)
 
-    src (src_ip_address) (src_port)
+read regbit
+~~~~~~~~~~~
 
-    dst (dst_ip_address) (dst_port)
+Display a single port register bit::
 
-    flexbytes (flexbytes_values)
+   testpmd> read regbit (port_id) (address) (bit_x)
 
-    vlan (vlan_id) queue (queue_id)
+For example, reading the lowest bit from the register in the example above::
 
-upd_signature_filter
-~~~~~~~~~~~~~~~~~~~~
+   testpmd> read regbit 0 0xEE00 0
+   port 0 PCI register at offset 0xEE00: bit 0=1
 
-Update a signature filter:
+write reg
+~~~~~~~~~
 
-# Command is displayed on several lines for clarity.
+Set the value of a port register::
 
-upd_signature_filter (port_id) (ip|udp|tcp|sctp)
+   testpmd> write reg (port_id) (address) (value)
 
-    src (src_ip_address) (src_port)
+For example, to clear a register::
 
-    dst (dst_ip_address) (dst_port)
+   testpmd> write reg 0 0xEE00 0x0
+   port 0 PCI register at offset 0xEE00: 0x00000000 (0)
 
-    flexbytes (flexbytes_values)
+write regfield
+~~~~~~~~~~~~~~
 
-    vlan (vlan_id) queue (queue_id)
+Set bit field of a port register::
 
-rm_signature_filter
-~~~~~~~~~~~~~~~~~~~
+   testpmd> write regfield (port_id) (address) (bit_x) (bit_y) (value)
 
-Remove a signature filter:
+For example, writing to the register cleared in the example above::
 
-# Command is displayed on several lines for clarity.
+   testpmd> write regfield 0 0xEE00 0 1 2
+   port 0 PCI register at offset 0xEE00: 0x00000002 (2)
 
-rm_signature_filter (port_id) (ip|udp|tcp|sctp)
+write regbit
+~~~~~~~~~~~~
 
-    src (src_ip_address) (src_port)
+Set single bit value of a port register::
 
-    dst (dst_ip_address) (dst_port)
+   testpmd> write regbit (port_id) (address) (bit_x) (value)
 
-    flexbytes (flexbytes_values)
+For example, to set the high bit in the register from the example above::
 
-    vlan (vlan_id)
+   testpmd> write regbit 0 0xEE00 31 1
+   port 0 PCI register at offset 0xEE00: 0x8000000A (2147483658)
 
-add_perfect_filter
-~~~~~~~~~~~~~~~~~~
 
-Add a perfect filter:
+Filter Functions
+----------------
 
-# Command is displayed on several lines for clarity.
+This section details the available filter functions that are available.
 
-add_perfect_filter (port_id) (ip|udp|tcp|sctp)
+ethertype_filter
+~~~~~~~~~~~~~~~~~~~~
 
-    src (src_ip_address) (src_port)
+Add or delete a L2 Ethertype filter, which identify packets by their L2 Ethertype mainly assign them to a receive queue::
 
-    dst (dst_ip_address) (dst_port)
+   ethertype_filter (port_id) (add|del) (mac_addr|mac_ignr) (mac_address) \
+                    ethertype (ether_type) (drop|fwd) queue (queue_id)
 
-    flexbytes (flexbytes_values)
+The available information parameters are:
 
-    vlan (vlan_id) queue (queue_id) soft (soft_id)
+* ``port_id``: The port which the Ethertype filter assigned on.
 
-upd_perfect_filter
-~~~~~~~~~~~~~~~~~~
+* ``mac_addr``: Compare destination mac address.
 
-Update a perfect filter:
+* ``mac_ignr``: Ignore destination mac address match.
 
-# Command is displayed on several lines for clarity.
+* ``mac_address``: Destination mac address to match.
 
-upd_perfect_filter (port_id) (ip|udp|tcp|sctp)
+* ``ether_type``: The EtherType value want to match,
+  for example 0x0806 for ARP packet. 0x0800 (IPv4) and 0x86DD (IPv6) are invalid.
 
-    src (src_ip_address) (src_port)
+* ``queue_id``: The receive queue associated with this EtherType filter.
+  It is meaningless when deleting or dropping.
 
-    dst (dst_ip_address) (dst_port)
+Example, to add/remove an ethertype filter rule::
 
-    flexbytes (flexbytes_values)
+   testpmd> ethertype_filter 0 add mac_ignr 00:11:22:33:44:55 \
+                             ethertype 0x0806 fwd queue 3
 
-    vlan (vlan_id) queue (queue_id)
+   testpmd> ethertype_filter 0 del mac_ignr 00:11:22:33:44:55 \
+                             ethertype 0x0806 fwd queue 3
 
-rm_perfect_filter
+2tuple_filter
 ~~~~~~~~~~~~~~~~~
 
-Remove a perfect filter:
-
-rm_perfect_filter (port_id) (ip|udp|tcp|sctp)
-
-    src (src_ip_address) (src_port)
-
-    dst (dst_ip_address) (dst_port)
+Add or delete a 2-tuple filter,
+which identifies packets by specific protocol and destination TCP/UDP port
+and forwards packets into one of the receive queues::
 
-    flexbytes (flexbytes_values)
+   2tuple_filter (port_id) (add|del) dst_port (dst_port_value) \
+                 protocol (protocol_value) mask (mask_value) \
+                 tcp_flags (tcp_flags_value) priority (prio_value) \
+                 queue (queue_id)
 
-    vlan (vlan_id) soft (soft_id)
+The available information parameters are:
 
-set_masks_filter
-~~~~~~~~~~~~~~~~
+* ``port_id``: The port which the 2-tuple filter assigned on.
 
-Set IPv4 filter masks:
+* ``dst_port_value``: Destination port in L4.
 
-# Command is displayed on several lines for clarity.
+* ``protocol_value``: IP L4 protocol.
 
-set_masks_filter (port_id) only_ip_flow (0|1)
+* ``mask_value``: Participates in the match or not by bit for field above, 1b means participate.
 
-    src_mask (ip_src_mask) (src_port_mask)
+* ``tcp_flags_value``: TCP control bits. The non-zero value is invalid, when the pro_value is not set to 0x06 (TCP).
 
-    dst_mask (ip_dst_mask) (dst_port_mask)
+* ``prio_value``: Priority of this filter.
 
-    flexbytes (0|1) vlan_id (0|1) vlan_prio (0|1)
+* ``queue_id``: The receive queue associated with this 2-tuple filter.
 
-set_ipv6_masks_filter
-~~~~~~~~~~~~~~~~~~~~~
+Example, to add/remove an 2tuple filter rule::
 
-Set IPv6 filter masks:
+   testpmd> 2tuple_filter 0 add dst_port 32 protocol 0x06 mask 0x03 \
+                          tcp_flags 0x02 priority 3 queue 3
 
-# Command is displayed on several lines for clarity.
+   testpmd> 2tuple_filter 0 del dst_port 32 protocol 0x06 mask 0x03 \
+                          tcp_flags 0x02 priority 3 queue 3
 
-set_ipv6_masks_filter (port_id) only_ip_flow (0|1)
+5tuple_filter
+~~~~~~~~~~~~~~~~~
 
-    src_mask (ip_src_mask) (src_port_mask)
+Add or delete a 5-tuple filter,
+which consists of a 5-tuple (protocol, source and destination IP addresses, source and destination TCP/UDP/SCTP port)
+and routes packets into one of the receive queues::
 
-    dst_mask (ip_dst_mask) (dst_port_mask)
+   5tuple_filter (port_id) (add|del) dst_ip (dst_address) src_ip \
+                 (src_address) dst_port (dst_port_value) \
+                 src_port (src_port_value) protocol (protocol_value) \
+                 mask (mask_value) tcp_flags (tcp_flags_value) \
+                 priority (prio_value) queue (queue_id)
 
-    flexbytes (0|1) vlan_id (0|1) vlan_prio (0|1)
+The available information parameters are:
 
-    compare_dst (0|1)
+* ``port_id``: The port which the 5-tuple filter assigned on.
 
-Link Bonding Functions
-----------------------
+* ``dst_address``: Destination IP address.
 
-The Link Bonding functions make it possible to dynamically create and
-manage link bonding devices from within testpmd interactive prompt.
+* ``src_address``: Source IP address.
 
-create bonded device
-~~~~~~~~~~~~~~~~~~~~
+* ``dst_port_value``: TCP/UDP destination port.
 
-Create a new bonding device:
+* ``src_port_value``: TCP/UDP source port.
 
-create bonded device (mode) (socket)
+* ``protocol_value``: L4 protocol.
 
-For example, to create a bonded device in mode 1 on socket 0.
+* ``mask_value``: Participates in the match or not by bit for field above, 1b means participate
 
-.. code-block:: console
+* ``tcp_flags_value``: TCP control bits. The non-zero value is invalid, when the protocol_value is not set to 0x06 (TCP).
 
-    testpmd> create bonded 1 0
-    created new bonded device (port X)
+* ``prio_value``: The priority of this filter.
 
-add bonding slave
-~~~~~~~~~~~~~~~~~
+* ``queue_id``: The receive queue associated with this 5-tuple filter.
 
-Adds Ethernet device to a Link Bonding device:
+Example, to add/remove an 5tuple filter rule::
 
-add bonding slave (slave id) (port id)
+   testpmd> 5tuple_filter 0 add dst_ip 2.2.2.5 src_ip 2.2.2.4 \
+            dst_port 64 src_port 32 protocol 0x06 mask 0x1F \
+            flags 0x0 priority 3 queue 3
 
-For example, to add Ethernet device (port 6) to a Link Bonding device (port 10).
+   testpmd> 5tuple_filter 0 del dst_ip 2.2.2.5 src_ip 2.2.2.4 \
+            dst_port 64 src_port 32 protocol 0x06 mask 0x1F \
+            flags 0x0 priority 3 queue 3
 
-.. code-block:: console
+syn_filter
+~~~~~~~~~~
 
-    testpmd> add bonding slave 6 10
+Using the  SYN filter, TCP packets whose *SYN* flag is set can be forwarded to a separate queue::
 
+   syn_filter (port_id) (add|del) priority (high|low) queue (queue_id)
 
-remove bonding slave
-~~~~~~~~~~~~~~~~~~~~
+The available information parameters are:
 
-Removes an Ethernet slave device from a Link Bonding device:
+* ``port_id``: The port which the SYN filter assigned on.
 
-remove bonding slave (slave id) (port id)
+* ``high``: This SYN filter has higher priority than other filters.
 
-For example, to remove Ethernet slave device (port 6) to a Link Bonding device (port 10).
+* ``low``: This SYN filter has lower priority than other filters.
 
-.. code-block:: console
+* ``queue_id``: The receive queue associated with this SYN filter
 
-    testpmd> remove bonding slave 6 10
+Example::
 
-set bonding mode
-~~~~~~~~~~~~~~~~
+   testpmd> syn_filter 0 add priority high queue 3
 
-Set the Link Bonding mode of a Link Bonding device:
+flex_filter
+~~~~~~~~~~~
 
-set bonding mode (value) (port id)
+With flex filter, packets can be recognized by any arbitrary pattern within the first 128 bytes of the packet
+and routed into one of the receive queues::
 
-For example, to set the bonding mode of a Link Bonding device (port 10) to broadcast (mode 3).
+   flex_filter (port_id) (add|del) len (len_value) bytes (bytes_value) \
+               mask (mask_value) priority (prio_value) queue (queue_id)
 
-.. code-block:: console
+The available information parameters are:
 
-    testpmd> set bonding mode 3 10
+* ``port_id``: The port which the Flex filter is assigned on.
 
-set bonding primary
-~~~~~~~~~~~~~~~~~~~
+* ``len_value``: Filter length in bytes, no greater than 128.
 
-Set an Ethernet slave device as the primary device on a Link Bonding device:
+* ``bytes_value``: A string in hexadecimal, means the value the flex filter needs to match.
 
-set bonding primary (slave id) (port id)
+* ``mask_value``: A string in hexadecimal, bit 1 means corresponding byte participates in the match.
 
-For example, to set the Ethernet slave device (port 6) as the primary port of a Link Bonding device (port 10).
+* ``prio_value``: The priority of this filter.
 
-.. code-block:: console
+* ``queue_id``: The receive queue associated with this Flex filter.
 
-    testpmd> set bonding primary 6 10
+Example::
 
-set bonding mac
-~~~~~~~~~~~~~~~
+   testpmd> flex_filter 0 add len 16 bytes 0x00000000000000000000000008060000 \
+                          mask 000C priority 3 queue 3
 
-Set the MAC address of a Link Bonding device:
+   testpmd> flex_filter 0 del len 16 bytes 0x00000000000000000000000008060000 \
+                          mask 000C priority 3 queue 3
 
-set bonding mac (port id) (mac)
 
-For example, to set the MAC address of a Link Bonding device (port 10) to 00:00:00:00:00:01
+.. _testpmd_flow_director:
 
-.. code-block:: console
+flow_director_filter
+~~~~~~~~~~~~~~~~~~~~
 
-    testpmd> set bonding mac 10 00:00:00:00:00:01
+The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
 
-set bonding xmit_balance_policy
-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+Two types of filtering are supported which are referred to as Perfect Match and Signature filters, the match mode
+is set by the ``--pkt-filter-mode`` command-line parameter:
 
-Set the transmission policy for a Link Bonding device when it is in Balance XOR mode:
+* Perfect match filters.
+  The hardware checks a match between the masked fields of the received packets and the programmed filters.
 
-set bonding xmit_balance_policy (port_id) (l2|l23|l34)
+* Signature filters.
+  The hardware checks a match between a hash-based signature of the masked fields of the received packet.
 
-For example, set a Link Bonding device (port 10) to use a balance policy of layer 3+4 (IP addresses & UDP ports )
+The Flow Director filters can match the different fields for different type of packet: flow type, specific input set
+per flow type and the flexible payload.
 
-.. code-block:: console
+The Flow Director can also mask out parts of all of these fields so that filters
+are only applied to certain fields or parts of the fields.
 
-    testpmd> set bonding xmit_balance_policy 10 l34
+Different NICs may have different capabilities, command show port fdir (port_id) can be used to acquire the information.
 
+# Commands to add flow director filters of different flow types::
 
-set bonding mon_period
-~~~~~~~~~~~~~~~~~~~~~~
+   flow_director_filter (port_id) (add|del|update) \
+                        flow (ipv4-other|ipv4-frag|ipv6-other|ipv6-frag)
+                        src (src_ip_address) dst (dst_ip_address) \
+                        vlan (vlan_value) flexbytes (flexbytes_value) \
+                        (drop|fwd) queue (queue_id) fd_id (fd_id_value)
 
-Set the link status monitoring polling period in milliseconds for a bonding devicie.
+   flow_director_filter (port_id) (add|del|update) \
+                        flow (ipv4-tcp|ipv4-udp|ipv6-tcp|ipv6-udp) \
+                        src (src_ip_address) (src_port) \
+                        dst (dst_ip_address) (dst_port) \
+                        vlan (vlan_value) flexbytes (flexbytes_value) \
+                        (drop|fwd) queue (queue_id) fd_id (fd_id_value)
 
-This adds support for PMD slave devices which do not support link status interrupts.
-When the mon_period is set to a value greater than 0 then all PMD's which do not support
-link status ISR will be queried every polling interval to check if their link status has changed.
+   flow_director_filter (port_id) (add|del|update) \
+                        flow (ipv4-sctp|ipv6-sctp) \
+                        src (src_ip_address) (src_port) \
+                        dst (dst_ip_address) (dst_port)
+                        tag (verification_tag) vlan (vlan_value) \
+                        flexbytes (flexbytes_value) (drop|fwd) \
+                        queue (queue_id) fd_id (fd_id_value)
 
-set bonding mon_period (port_id) (value)
+   flow_director_filter (port_id) (add|del|update) flow l2_payload \
+                        ether (ethertype) flexbytes (flexbytes_value) \
+                        (drop|fwd) queue (queue_id) fd_id (fd_id_value)
 
-For example, to set the link status monitoring polling period of bonded device (port 5) to 150ms
+For example, to add an ipv4-udp flow type filter::
 
-.. code-block:: console
+   testpmd> flow_director_filter 0 add flow ipv4-udp src 2.2.2.3 32 \
+            dst 2.2.2.5 33 vlan 0x1 flexbytes (0x88,0x48) fwd queue 1 fd_id 1
 
-    testpmd> set bonding mon_period 5 150
+For example, add an ipv4-other flow type filter::
 
+   testpmd> flow_director_filter 0 add flow ipv4-other src 2.2.2.3 \
+             dst 2.2.2.5 vlan 0x1 flexbytes (0x88,0x48) fwd queue 1 fd_id 1
 
-show bonding config
+flush_flow_director
 ~~~~~~~~~~~~~~~~~~~
 
-Show the current configuration of a Link Bonding device:
-
-show bonding config (port id)
-
-For example,
-to show the configuration a Link Bonding device (port 9) with 3 slave devices (1, 3, 4)
-in balance mode with a transmission policy of layer 2+3.
+Flush all flow director filters on a device::
 
-.. code-block:: console
+   testpmd> flush_flow_director (port_id)
 
-    testpmd> show bonding config 9
-        Bonding mode: 2
-        Balance Xmit Policy: BALANCE_XMIT_POLICY_LAYER23
-        Slaves (3): [1 3 4]
-        Active Slaves (3): [1 3 4]
-        Primary: [3]
-
-Register Functions
-------------------
+Example, to flush all flow director filter on port 0::
 
-The Register functions can be used to read from and write to registers on the network card referenced by a port number.
-This is mainly useful for debugging purposes.
-Reference should be made to the appropriate datasheet for the network card for details on the register addresses
-and fields that can be accessed.
+   testpmd> flush_flow_director 0
 
-read reg
-~~~~~~~~
+flow_director_mask
+~~~~~~~~~~~~~~~~~~
 
-Display the value of a port register:
+Set flow director's input masks::
 
-read reg (port_id) (address)
+   flow_director_mask (port_id) vlan (vlan_value) \
+                      src_mask (ipv4_src) (ipv6_src) (src_port) \
+                      dst_mask (ipv4_dst) (ipv6_dst) (dst_port)
 
-For example, to examine the Flow Director control register (FDIRCTL, 0x0000EE000) on an IntelĀ® 82599 10 GbE Controller:
+Example, to set flow director mask on port 0::
 
-.. code-block:: console
+   testpmd> flow_director_mask 0 vlan 0xefff \
+            src_mask 255.255.255.255 \
+                FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF 0xFFFF \
+            dst_mask 255.255.255.255 \
+                FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF 0xFFFF
 
-    testpmd> read reg 0 0xEE00
-    port 0 PCI register at offset 0xEE00: 0x4A060029 (1241907241)
+flow_director_flex_mask
+~~~~~~~~~~~~~~~~~~~~~~~
 
-read regfield
-~~~~~~~~~~~~~
+set masks of flow director's flexible payload based on certain flow type::
 
-Display a port register bit field:
+   testpmd> flow_director_flex_mask (port_id) \
+            flow (none|ipv4-other|ipv4-frag|ipv4-tcp|ipv4-udp|ipv4-sctp| \
+                  ipv6-other|ipv6-frag|ipv6-tcp|ipv6-udp|ipv6-sctp| \
+                  l2_payload|all) (mask)
 
-read regfield (port_id) (address) (bit_x) (bit_y)
+Example, to set flow director's flex mask for all flow type on port 0::
 
-For example, reading the lowest two bits from the register in the example above:
+   testpmd> flow_director_flex_mask 0 flow all \
+            (0xff,0xff,0,0,0,0,0,0,0,0,0,0,0,0,0,0)
 
-.. code-block:: console
 
-    testpmd> read regfield 0 0xEE00 0 1
-    port 0 PCI register at offset 0xEE00: bits[0, 1]=0x1 (1)
+flow_director_flex_payload
+~~~~~~~~~~~~~~~~~~~~~~~~~~
 
-read regbit
-~~~~~~~~~~~
+Configure flexible payload selection::
 
-Display a single port register bit:
+   flow_director_flex_payload (port_id) (raw|l2|l3|l4) (config)
 
-read regbit (port_id) (address) (bit_x)
+For example, to select the first 16 bytes from the offset 4 (bytes) of packet's payload as flexible payload::
 
-For example, reading the lowest bit from the register in the example above:
+   testpmd> flow_director_flex_payload 0 l4 \
+            (4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19)
 
-.. code-block:: console
+get_sym_hash_ena_per_port
+~~~~~~~~~~~~~~~~~~~~~~~~~
 
-    testpmd> read regbit 0 0xEE00 0
-    port 0 PCI register at offset 0xEE00: bit 0=1
+Get symmetric hash enable configuration per port::
 
-write reg
-~~~~~~~~~
+   get_sym_hash_ena_per_port (port_id)
 
-Set the value of a port register:
+For example, to get symmetric hash enable configuration of port 1::
 
-write reg (port_id) (address) (value)
+   testpmd> get_sym_hash_ena_per_port 1
 
-For example, to clear a register:
+set_sym_hash_ena_per_port
+~~~~~~~~~~~~~~~~~~~~~~~~~
 
-.. code-block:: console
+Set symmetric hash enable configuration per port to enable or disable::
 
-    testpmd> write reg 0 0xEE00 0x0
-    port 0 PCI register at offset 0xEE00: 0x00000000 (0)
+   set_sym_hash_ena_per_port (port_id) (enable|disable)
 
-write regfield
-~~~~~~~~~~~~~~
+For example, to set symmetric hash enable configuration of port 1 to enable::
 
-Set bit field of a port register:
+   testpmd> set_sym_hash_ena_per_port 1 enable
 
-write regfield (port_id) (address) (bit_x) (bit_y) (value)
+get_hash_global_config
+~~~~~~~~~~~~~~~~~~~~~~
 
-For example, writing to the register cleared in the example above:
+Get the global configurations of hash filters::
 
-.. code-block:: console
+   get_hash_global_config (port_id)
 
-    testpmd> write regfield 0 0xEE00 0 1 2
-    port 0 PCI register at offset 0xEE00: 0x00000002 (2)
+For example, to get the global configurations of hash filters of port 1::
 
-write regbit
-~~~~~~~~~~~~
+   testpmd> get_hash_global_config 1
 
-Set single bit value of a port register:
+set_hash_global_config
+~~~~~~~~~~~~~~~~~~~~~~
 
-write regbit (port_id) (address) (bit_x) (value)
+Set the global configurations of hash filters::
 
-For example, to set the high bit in the register from the example above:
+   set_hash_global_config (port_id) (toeplitz|simple_xor|default) \
+   (ipv4|ipv4-frag|ipv4-tcp|ipv4-udp|ipv4-sctp|ipv4-other|ipv6|ipv6-frag| \
+   ipv6-tcp|ipv6-udp|ipv6-sctp|ipv6-other|l2_payload) \
+   (enable|disable)
 
-.. code-block:: console
+For example, to enable simple_xor for flow type of ipv6 on port 2::
 
-    testpmd> write regbit 0 0xEE00 31 1
-    port 0 PCI register at offset 0xEE00: 0x8000000A (2147483658)
+   testpmd> set_hash_global_config 2 simple_xor ipv6 enable