#define BNX2X_PMD_VER_PREFIX "BNX2X PMD"
#define BNX2X_PMD_VERSION_MAJOR 1
#define BNX2X_PMD_VERSION_MINOR 0
-#define BNX2X_PMD_VERSION_REVISION 1
+#define BNX2X_PMD_VERSION_REVISION 5
#define BNX2X_PMD_VERSION_PATCH 1
static inline const char *
static void bnx2x_free_mem(struct bnx2x_softc *sc);
static int bnx2x_alloc_fw_stats_mem(struct bnx2x_softc *sc);
static void bnx2x_free_fw_stats_mem(struct bnx2x_softc *sc);
-static __attribute__ ((noinline))
+static __rte_noinline
int bnx2x_nic_load(struct bnx2x_softc *sc);
static int bnx2x_handle_sp_tq(struct bnx2x_softc *sc);
PMD_DRV_LOG(ERR, "DMA alloc failed for %s", msg);
return -ENOMEM;
}
- dma->paddr = (uint64_t) z->phys_addr;
+ dma->paddr = (uint64_t) z->iova;
dma->vaddr = z->addr;
PMD_DRV_LOG(DEBUG, "%s: virt=%p phys=%" PRIx64, msg, dma->vaddr, dma->paddr);
/*
* Post a slowpath command.
*
- * A slowpath command is used to propogate a configuration change through
+ * A slowpath command is used to propagate a configuration change through
* the controller in a controlled manner, allowing each STORM processor and
* other H/W blocks to phase in the change. The commands sent on the
* slowpath are referred to as ramrods. Depending on the ramrod used the
}
/* stop the controller */
-__attribute__ ((noinline))
+__rte_noinline
int
bnx2x_nic_unload(struct bnx2x_softc *sc, uint32_t unload_mode, uint8_t keep_link)
{
/*
* Nothing to do during unload if previous bnx2x_nic_load()
- * did not completed succesfully - all resourses are released.
+ * did not completed successfully - all resourses are released.
*/
if ((sc->state == BNX2X_STATE_CLOSED) || (sc->state == BNX2X_STATE_ERROR)) {
return 0;
}
PMD_TX_LOG(DEBUG,
- "start bd: nbytes %d flags %x vlan %x\n",
+ "start bd: nbytes %d flags %x vlan %x",
tx_start_bd->nbytes,
tx_start_bd->bd_flags.as_bitfield,
tx_start_bd->vlan_or_ethertype);
mask1 = REG_RD(sc, PXP2_REG_PXP2_INT_MASK_1);
val0 = REG_RD(sc, PXP2_REG_PXP2_INT_STS_0);
/*
- * If the olny PXP2_EOP_ERROR_BIT is set in
+ * If the only PXP2_EOP_ERROR_BIT is set in
* STS0 and STS1 - clear it
*
* probably we lose additional attentions between
(val | HC_CONFIG_0_REG_BLOCK_DISABLE_0));
} else {
-/* Prevent incomming interrupts in IGU */
+/* Prevent incoming interrupts in IGU */
val = REG_RD(sc, IGU_REG_BLOCK_CONFIGURATION);
if (close)
/* Hash bits */
params.rss_result_mask = MULTI_MASK;
- (void)rte_memcpy(params.ind_table, rss_obj->ind_table,
+ rte_memcpy(params.ind_table, rss_obj->ind_table,
sizeof(params.ind_table));
if (config_hash) {
/* fill a user request section if needed */
if (!bnx2x_test_bit(RAMROD_CONT, ramrod_flags)) {
- (void)rte_memcpy(ramrod_param.user_req.u.mac.mac, mac,
+ rte_memcpy(ramrod_param.user_req.u.mac.mac, mac,
ETH_ALEN);
bnx2x_set_bit(mac_type, &ramrod_param.user_req.vlan_mac_flags);
sc->link_cnt++;
/* report new link params and remember the state for the next time */
- (void)rte_memcpy(&sc->last_reported_link, &cur_data, sizeof(cur_data));
+ rte_memcpy(&sc->last_reported_link, &cur_data, sizeof(cur_data));
if (bnx2x_test_bit(BNX2X_LINK_REPORT_LINK_DOWN,
&cur_data.link_report_flags)) {
}
/* start the controller */
-static __attribute__ ((noinline))
+static __rte_noinline
int bnx2x_nic_load(struct bnx2x_softc *sc)
{
uint32_t val;