*/
static void *
mlx5_flow_meter_action_create(struct mlx5_priv *priv,
- struct mlx5_flow_meter *fm)
+ struct mlx5_flow_meter_info *fm)
{
#ifdef HAVE_MLX5_DR_CREATE_ACTION_FLOW_METER
struct mlx5dv_dr_flow_meter_attr mtr_init;
- void *attr = fm->mfts->fmp;
+ uint32_t fmp[MLX5_ST_SZ_DW(flow_meter_parameters)];
struct mlx5_flow_meter_srtcm_rfc2697_prm *srtcm =
&fm->profile->srtcm_prm;
+ uint32_t cbs_cir = rte_be_to_cpu_32(srtcm->cbs_cir);
+ uint32_t ebs_eir = rte_be_to_cpu_32(srtcm->ebs_eir);
+ uint32_t val;
+ enum mlx5_meter_domain domain =
+ fm->transfer ? MLX5_MTR_DOMAIN_TRANSFER :
+ fm->egress ? MLX5_MTR_DOMAIN_EGRESS :
+ MLX5_MTR_DOMAIN_INGRESS;
+ struct mlx5_flow_meter_def_policy *def_policy =
+ priv->sh->mtrmng->def_policy[domain];
- fm->mfts->fmp_size = MLX5_ST_SZ_BYTES(flow_meter_parameters);
- memset(attr, 0, fm->mfts->fmp_size);
- MLX5_SET(flow_meter_parameters, attr, valid, 1);
- MLX5_SET(flow_meter_parameters, attr, bucket_overflow, 1);
- MLX5_SET(flow_meter_parameters, attr,
- start_color, MLX5_FLOW_COLOR_GREEN);
- MLX5_SET(flow_meter_parameters, attr, both_buckets_on_green, 0);
- MLX5_SET(flow_meter_parameters,
- attr, cbs_exponent, srtcm->cbs_exponent);
- MLX5_SET(flow_meter_parameters,
- attr, cbs_mantissa, srtcm->cbs_mantissa);
- MLX5_SET(flow_meter_parameters,
- attr, cir_exponent, srtcm->cir_exponent);
- MLX5_SET(flow_meter_parameters,
- attr, cir_mantissa, srtcm->cir_mantissa);
- MLX5_SET(flow_meter_parameters,
- attr, ebs_exponent, srtcm->ebs_exponent);
- MLX5_SET(flow_meter_parameters,
- attr, ebs_mantissa, srtcm->ebs_mantissa);
- mtr_init.next_table =
- fm->transfer ? fm->mfts->transfer.tbl->obj :
- fm->egress ? fm->mfts->egress.tbl->obj :
- fm->mfts->ingress.tbl->obj;
+ memset(fmp, 0, MLX5_ST_SZ_BYTES(flow_meter_parameters));
+ MLX5_SET(flow_meter_parameters, fmp, valid, 1);
+ MLX5_SET(flow_meter_parameters, fmp, bucket_overflow, 1);
+ MLX5_SET(flow_meter_parameters, fmp,
+ start_color, MLX5_FLOW_COLOR_GREEN);
+ MLX5_SET(flow_meter_parameters, fmp, both_buckets_on_green, 0);
+ val = (cbs_cir >> ASO_DSEG_CBS_EXP_OFFSET) & ASO_DSEG_EXP_MASK;
+ MLX5_SET(flow_meter_parameters, fmp, cbs_exponent, val);
+ val = (cbs_cir >> ASO_DSEG_CBS_MAN_OFFSET) & ASO_DSEG_MAN_MASK;
+ MLX5_SET(flow_meter_parameters, fmp, cbs_mantissa, val);
+ val = (cbs_cir >> ASO_DSEG_CIR_EXP_OFFSET) & ASO_DSEG_EXP_MASK;
+ MLX5_SET(flow_meter_parameters, fmp, cir_exponent, val);
+ val = (cbs_cir & ASO_DSEG_MAN_MASK);
+ MLX5_SET(flow_meter_parameters, fmp, cir_mantissa, val);
+ val = (ebs_eir >> ASO_DSEG_EBS_EXP_OFFSET) & ASO_DSEG_EXP_MASK;
+ MLX5_SET(flow_meter_parameters, fmp, ebs_exponent, val);
+ val = (ebs_eir >> ASO_DSEG_EBS_MAN_OFFSET) & ASO_DSEG_MAN_MASK;
+ MLX5_SET(flow_meter_parameters, fmp, ebs_mantissa, val);
+ mtr_init.next_table = def_policy->sub_policy.tbl_rsc->obj;
mtr_init.reg_c_index = priv->mtr_color_reg - REG_C_0;
- mtr_init.flow_meter_parameter = fm->mfts->fmp;
- mtr_init.flow_meter_parameter_sz = fm->mfts->fmp_size;
+ mtr_init.flow_meter_parameter = fmp;
+ mtr_init.flow_meter_parameter_sz =
+ MLX5_ST_SZ_BYTES(flow_meter_parameters);
mtr_init.active = fm->active_state;
return mlx5_glue->dv_create_flow_action_meter(&mtr_init);
#else
struct mlx5_flow_meter_profile *fmp;
TAILQ_FOREACH(fmp, fmps, next)
- if (meter_profile_id == fmp->meter_profile_id)
+ if (meter_profile_id == fmp->id)
return fmp;
return NULL;
}
NULL,
"Meter profile already exists.");
if (profile->alg == RTE_MTR_SRTCM_RFC2697) {
- if (priv->config.hca_attr.qos.srtcm_sup) {
+ if (priv->config.hca_attr.qos.flow_meter_old) {
/* Verify support for flow meter parameters. */
- if (profile->srtcm_rfc2697.cir > 0 &&
- profile->srtcm_rfc2697.cir <= MLX5_SRTCM_CIR_MAX &&
- profile->srtcm_rfc2697.cbs > 0 &&
- profile->srtcm_rfc2697.cbs <= MLX5_SRTCM_CBS_MAX &&
- profile->srtcm_rfc2697.ebs <= MLX5_SRTCM_EBS_MAX)
- return 0;
- else
+ if (priv->sh->meter_aso_en && profile->packet_mode) {
+ if (profile->srtcm_rfc2697.cir > 0 &&
+ (profile->srtcm_rfc2697.cir <<
+ MLX5_MTRS_PPS_MAP_BPS_SHIFT)
+ <= MLX5_SRTCM_CIR_MAX &&
+ profile->srtcm_rfc2697.cbs > 0 &&
+ (profile->srtcm_rfc2697.cbs <<
+ MLX5_MTRS_PPS_MAP_BPS_SHIFT)
+ <= MLX5_SRTCM_CBS_MAX &&
+ (profile->srtcm_rfc2697.ebs <<
+ MLX5_MTRS_PPS_MAP_BPS_SHIFT)
+ <= MLX5_SRTCM_EBS_MAX)
+ return 0;
return -rte_mtr_error_set
(error, ENOTSUP,
RTE_MTR_ERROR_TYPE_MTR_PARAMS,
profile->srtcm_rfc2697.ebs ?
"Metering value ebs must be 0." :
"Invalid metering parameters.");
+ }
+ if (profile->srtcm_rfc2697.cir > 0 &&
+ profile->srtcm_rfc2697.cir <=
+ MLX5_SRTCM_CIR_MAX &&
+ profile->srtcm_rfc2697.cbs > 0 &&
+ profile->srtcm_rfc2697.cbs <=
+ MLX5_SRTCM_CBS_MAX &&
+ profile->srtcm_rfc2697.ebs <=
+ MLX5_SRTCM_EBS_MAX)
+ return 0;
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_MTR_PARAMS,
+ NULL,
+ profile->srtcm_rfc2697.ebs ?
+ "Metering value ebs must be 0." :
+ "Invalid metering parameters.");
}
}
return -rte_mtr_error_set(error, ENOTSUP,
*/
static int
mlx5_flow_meter_param_fill(struct mlx5_flow_meter_profile *fmp,
- struct rte_mtr_error *error)
+ struct mlx5_priv *priv, struct rte_mtr_error *error)
{
struct mlx5_flow_meter_srtcm_rfc2697_prm *srtcm = &fmp->srtcm_prm;
uint8_t man, exp;
+ uint32_t cbs_exp, cbs_man, cir_exp, cir_man;
+ uint32_t ebs_exp, ebs_man;
+ uint64_t cir, cbs, ebs;
if (fmp->profile.alg != RTE_MTR_SRTCM_RFC2697)
return -rte_mtr_error_set(error, ENOTSUP,
RTE_MTR_ERROR_TYPE_METER_PROFILE,
NULL, "Metering algorithm not supported.");
+ if (!priv->sh->meter_aso_en && fmp->profile.packet_mode)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_METER_PROFILE,
+ NULL, "Metering algorithm packet mode not supported.");
+ if (priv->sh->meter_aso_en && fmp->profile.packet_mode) {
+ cir = fmp->profile.srtcm_rfc2697.cir <<
+ MLX5_MTRS_PPS_MAP_BPS_SHIFT;
+ cbs = fmp->profile.srtcm_rfc2697.cbs <<
+ MLX5_MTRS_PPS_MAP_BPS_SHIFT;
+ ebs = fmp->profile.srtcm_rfc2697.ebs <<
+ MLX5_MTRS_PPS_MAP_BPS_SHIFT;
+ } else {
+ cir = fmp->profile.srtcm_rfc2697.cir;
+ cbs = fmp->profile.srtcm_rfc2697.cbs;
+ ebs = fmp->profile.srtcm_rfc2697.ebs;
+ }
+ /* cir = 8G * cir_mantissa * 1/(2^cir_exponent)) Bytes/Sec */
+ mlx5_flow_meter_cir_man_exp_calc(cir, &man, &exp);
+ /* Check if cir mantissa is too large. */
+ if (exp > ASO_DSEG_CIR_EXP_MASK)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL,
+ "meter profile parameter cir is"
+ " not supported.");
+ cir_man = man;
+ cir_exp = exp;
/* cbs = cbs_mantissa * 2^cbs_exponent */
- mlx5_flow_meter_xbs_man_exp_calc(fmp->profile.srtcm_rfc2697.cbs,
- &man, &exp);
- srtcm->cbs_mantissa = man;
- srtcm->cbs_exponent = exp;
+ mlx5_flow_meter_xbs_man_exp_calc(cbs, &man, &exp);
/* Check if cbs mantissa is too large. */
- if (srtcm->cbs_exponent != exp)
- return -rte_mtr_error_set(error, EINVAL,
+ if (exp > ASO_DSEG_EXP_MASK)
+ return -rte_mtr_error_set(error, ENOTSUP,
RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL,
- "Metering profile parameter cbs is"
- " invalid.");
- /* ebs = ebs_mantissa * 2^ebs_exponent */
- mlx5_flow_meter_xbs_man_exp_calc(fmp->profile.srtcm_rfc2697.ebs,
- &man, &exp);
- srtcm->ebs_mantissa = man;
- srtcm->ebs_exponent = exp;
+ "meter profile parameter cbs is"
+ " not supported.");
+ cbs_man = man;
+ cbs_exp = exp;
+ srtcm->cbs_cir = rte_cpu_to_be_32(cbs_exp << ASO_DSEG_CBS_EXP_OFFSET |
+ cbs_man << ASO_DSEG_CBS_MAN_OFFSET |
+ cir_exp << ASO_DSEG_CIR_EXP_OFFSET |
+ cir_man);
+ mlx5_flow_meter_xbs_man_exp_calc(ebs, &man, &exp);
/* Check if ebs mantissa is too large. */
- if (srtcm->ebs_exponent != exp)
- return -rte_mtr_error_set(error, EINVAL,
- RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL,
- "Metering profile parameter ebs is"
- " invalid.");
- /* cir = 8G * cir_mantissa * 1/(2^cir_exponent)) Bytes/Sec */
- mlx5_flow_meter_cir_man_exp_calc(fmp->profile.srtcm_rfc2697.cir,
- &man, &exp);
- srtcm->cir_mantissa = man;
- srtcm->cir_exponent = exp;
- /* Check if cir mantissa is too large. */
- if (srtcm->cir_exponent != exp)
- return -rte_mtr_error_set(error, EINVAL,
+ if (exp > ASO_DSEG_EXP_MASK)
+ return -rte_mtr_error_set(error, ENOTSUP,
RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL,
- "Metering profile parameter cir is"
- " invalid.");
+ "meter profile parameter ebs is"
+ " not supported.");
+ ebs_man = man;
+ ebs_exp = exp;
+ srtcm->ebs_eir = rte_cpu_to_be_32(ebs_exp << ASO_DSEG_EBS_EXP_OFFSET |
+ ebs_man << ASO_DSEG_EBS_MAN_OFFSET);
return 0;
}
RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
"Meter is not supported");
memset(cap, 0, sizeof(*cap));
- cap->n_max = 1 << qattr->log_max_flow_meter;
+ if (priv->sh->meter_aso_en) {
+ /* 2 meters per one ASO cache line. */
+ cap->n_max = 1 << (qattr->log_max_num_meter_aso + 1);
+ cap->srtcm_rfc2697_packet_mode_supported = 1;
+ } else {
+ cap->n_max = 1 << qattr->log_max_flow_meter;
+ cap->srtcm_rfc2697_packet_mode_supported = 0;
+ }
+ cap->srtcm_rfc2697_byte_mode_supported = 1;
cap->n_shared_max = cap->n_max;
cap->identical = 1;
cap->shared_identical = 1;
cap->shared_n_flows_per_mtr_max = 4 << 20;
/* 2M flows can share the same meter. */
cap->chaining_n_mtrs_per_flow_max = 1; /* Chaining is not supported. */
- cap->meter_srtcm_rfc2697_n_max = qattr->srtcm_sup ? cap->n_max : 0;
+ cap->meter_srtcm_rfc2697_n_max = qattr->flow_meter_old ? cap->n_max : 0;
cap->meter_rate_max = 1ULL << 40; /* 1 Tera tokens per sec. */
- cap->policer_action_drop_supported = 1;
cap->stats_mask = RTE_MTR_STATS_N_BYTES_DROPPED |
RTE_MTR_STATS_N_PKTS_DROPPED;
return 0;
NULL, "Meter profile memory "
"alloc failed.");
/* Fill profile info. */
- fmp->meter_profile_id = meter_profile_id;
+ fmp->id = meter_profile_id;
fmp->profile = *profile;
/* Fill the flow meter parameters for the PRM. */
- ret = mlx5_flow_meter_param_fill(fmp, error);
+ ret = mlx5_flow_meter_param_fill(fmp, priv, error);
if (ret)
goto error;
/* Add to list. */
}
/**
- * Convert wrong color setting action to verbose error.
+ * Find policy by id.
+ *
+ * @param[in] dev
+ * Pointer to Ethernet device.
+ * @param policy_id
+ * Policy id.
+ *
+ * @return
+ * Pointer to the policy found on success, NULL otherwise.
+ */
+struct mlx5_flow_meter_policy *
+mlx5_flow_meter_policy_find(struct rte_eth_dev *dev,
+ uint32_t policy_id,
+ uint32_t *policy_idx)
+{
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct mlx5_flow_meter_sub_policy *sub_policy = NULL;
+ union mlx5_l3t_data data;
+
+ if (policy_id > MLX5_MAX_SUB_POLICY_TBL_NUM ||
+ !priv->sh->mtrmng->policy_idx_tbl)
+ return NULL;
+ if (mlx5_l3t_get_entry(priv->sh->mtrmng->policy_idx_tbl,
+ policy_id, &data) ||
+ !data.dword)
+ return NULL;
+ if (policy_idx)
+ *policy_idx = data.dword;
+ sub_policy = mlx5_ipool_get(priv->sh->ipool[MLX5_IPOOL_MTR_POLICY],
+ data.dword);
+ /* Remove reference taken by the mlx5_l3t_get_entry. */
+ mlx5_l3t_clear_entry(priv->sh->mtrmng->policy_idx_tbl,
+ policy_id);
+ if (sub_policy)
+ if (sub_policy->main_policy_id)
+ return sub_policy->main_policy;
+ return NULL;
+}
+
+/**
+ * Callback to check MTR policy action validate
+ *
+ * @param[in] dev
+ * Pointer to Ethernet device.
+ * @param[in] actions
+ * Pointer to meter policy action detail.
+ * @param[out] error
+ * Pointer to the error structure.
+ *
+ * @return
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_policy_validate(struct rte_eth_dev *dev,
+ struct rte_mtr_meter_policy_params *policy,
+ struct rte_mtr_error *error)
+{
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct rte_flow_attr attr = { .transfer =
+ priv->config.dv_esw_en ? 1 : 0};
+ bool is_rss = false;
+ bool is_def_policy = false;
+ uint8_t domain_bitmap;
+ int ret;
+
+ if (!priv->mtr_en || !priv->sh->meter_aso_en)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_METER_POLICY,
+ NULL, "meter policy unsupported.");
+ ret = mlx5_flow_validate_mtr_acts(dev, policy->actions, &attr,
+ &is_rss, &domain_bitmap, &is_def_policy, error);
+ if (ret)
+ return ret;
+ return 0;
+}
+
+static int
+__mlx5_flow_meter_policy_delete(struct rte_eth_dev *dev,
+ uint32_t policy_id,
+ struct mlx5_flow_meter_policy *mtr_policy,
+ struct rte_mtr_error *error)
+{
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct mlx5_flow_meter_sub_policy *sub_policy;
+ uint32_t i, j;
+ uint16_t sub_policy_num;
+
+ rte_spinlock_lock(&mtr_policy->sl);
+ if (mtr_policy->ref_cnt) {
+ rte_spinlock_unlock(&mtr_policy->sl);
+ return -rte_mtr_error_set(error, EBUSY,
+ RTE_MTR_ERROR_TYPE_METER_POLICY_ID,
+ NULL,
+ "Meter policy object is being used.");
+ }
+ mlx5_flow_destroy_policy_rules(dev, mtr_policy);
+ mlx5_flow_destroy_mtr_acts(dev, mtr_policy);
+ for (i = 0; i < MLX5_MTR_DOMAIN_MAX; i++) {
+ sub_policy_num = (mtr_policy->sub_policy_num >>
+ (MLX5_MTR_SUB_POLICY_NUM_SHIFT * i)) &
+ MLX5_MTR_SUB_POLICY_NUM_MASK;
+ if (sub_policy_num) {
+ for (j = 0; j < sub_policy_num; j++) {
+ sub_policy = mtr_policy->sub_policys[i][j];
+ if (sub_policy)
+ mlx5_ipool_free
+ (priv->sh->ipool[MLX5_IPOOL_MTR_POLICY],
+ sub_policy->idx);
+ }
+ }
+ }
+ if (priv->sh->mtrmng->policy_idx_tbl) {
+ if (mlx5_l3t_clear_entry(priv->sh->mtrmng->policy_idx_tbl,
+ policy_id)) {
+ rte_spinlock_unlock(&mtr_policy->sl);
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL,
+ "Fail to delete policy in index table.");
+ }
+ }
+ rte_spinlock_unlock(&mtr_policy->sl);
+ return 0;
+}
+
+/**
+ * Callback to add MTR policy.
+ *
+ * @param[in] dev
+ * Pointer to Ethernet device.
+ * @param[out] policy_id
+ * Pointer to policy id
+ * @param[in] actions
+ * Pointer to meter policy action detail.
+ * @param[out] error
+ * Pointer to the error structure.
+ *
+ * @return
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
+ */
+static int
+mlx5_flow_meter_policy_add(struct rte_eth_dev *dev,
+ uint32_t policy_id,
+ struct rte_mtr_meter_policy_params *policy,
+ struct rte_mtr_error *error)
+{
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct rte_flow_attr attr = { .transfer =
+ priv->config.dv_esw_en ? 1 : 0};
+ uint32_t sub_policy_idx = 0;
+ uint32_t policy_idx = 0;
+ struct mlx5_flow_meter_policy *mtr_policy = NULL;
+ struct mlx5_flow_meter_sub_policy *sub_policy;
+ bool is_rss = false;
+ bool is_def_policy = false;
+ uint32_t i;
+ int ret;
+ uint32_t policy_size = sizeof(struct mlx5_flow_meter_policy);
+ uint16_t sub_policy_num;
+ uint8_t domain_bitmap = 0;
+ union mlx5_l3t_data data;
+
+ if (!priv->mtr_en)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_METER_POLICY,
+ NULL, "meter policy unsupported.");
+ if (policy_id == MLX5_INVALID_POLICY_ID)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL,
+ "policy ID is invalid. ");
+ if (policy_id == priv->sh->mtrmng->def_policy_id)
+ return -rte_mtr_error_set(error, EEXIST,
+ RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL,
+ "policy ID exists. ");
+ mtr_policy = mlx5_flow_meter_policy_find(dev, policy_id,
+ &policy_idx);
+ if (mtr_policy)
+ return -rte_mtr_error_set(error, EEXIST,
+ RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL,
+ "policy ID exists. ");
+ ret = mlx5_flow_validate_mtr_acts(dev, policy->actions, &attr,
+ &is_rss, &domain_bitmap, &is_def_policy, error);
+ if (ret)
+ return ret;
+ if (!domain_bitmap)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_METER_POLICY,
+ NULL, "fail to find policy domain.");
+ if (is_def_policy) {
+ if (priv->sh->mtrmng->def_policy_id != MLX5_INVALID_POLICY_ID)
+ return -rte_mtr_error_set(error, EEXIST,
+ RTE_MTR_ERROR_TYPE_METER_POLICY_ID,
+ NULL, "a policy with similar actions "
+ "is already configured");
+ if (mlx5_flow_create_def_policy(dev))
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_METER_POLICY,
+ NULL,
+ "fail to create non-terminated policy.");
+ priv->sh->mtrmng->def_policy_id = policy_id;
+ return 0;
+ }
+ if (!priv->sh->meter_aso_en)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_METER_POLICY, NULL,
+ "no ASO capability to support the policy ");
+ for (i = 0; i < MLX5_MTR_DOMAIN_MAX; i++) {
+ if (!(domain_bitmap & (1 << i)))
+ continue;
+ if (is_rss) {
+ policy_size +=
+ sizeof(struct mlx5_flow_meter_sub_policy *) *
+ MLX5_MTR_RSS_MAX_SUB_POLICY;
+ break;
+ }
+ policy_size += sizeof(struct mlx5_flow_meter_sub_policy *);
+ }
+ mtr_policy = mlx5_malloc(MLX5_MEM_ZERO, policy_size,
+ RTE_CACHE_LINE_SIZE, SOCKET_ID_ANY);
+ if (!mtr_policy)
+ return -rte_mtr_error_set(error, ENOMEM,
+ RTE_MTR_ERROR_TYPE_METER_POLICY, NULL,
+ "Memory alloc failed for meter policy.");
+ policy_size = sizeof(struct mlx5_flow_meter_policy);
+ for (i = 0; i < MLX5_MTR_DOMAIN_MAX; i++) {
+ if (!(domain_bitmap & (1 << i)))
+ continue;
+ if (i == MLX5_MTR_DOMAIN_INGRESS)
+ mtr_policy->ingress = 1;
+ if (i == MLX5_MTR_DOMAIN_EGRESS)
+ mtr_policy->egress = 1;
+ if (i == MLX5_MTR_DOMAIN_TRANSFER)
+ mtr_policy->transfer = 1;
+ sub_policy = mlx5_ipool_zmalloc
+ (priv->sh->ipool[MLX5_IPOOL_MTR_POLICY],
+ &sub_policy_idx);
+ if (!sub_policy)
+ goto policy_add_err;
+ if (sub_policy_idx > MLX5_MAX_SUB_POLICY_TBL_NUM)
+ goto policy_add_err;
+ sub_policy->idx = sub_policy_idx;
+ sub_policy->main_policy = mtr_policy;
+ if (!policy_idx) {
+ policy_idx = sub_policy_idx;
+ sub_policy->main_policy_id = 1;
+ }
+ mtr_policy->sub_policys[i] =
+ (struct mlx5_flow_meter_sub_policy **)
+ ((uint8_t *)mtr_policy + policy_size);
+ mtr_policy->sub_policys[i][0] = sub_policy;
+ sub_policy_num = (mtr_policy->sub_policy_num >>
+ (MLX5_MTR_SUB_POLICY_NUM_SHIFT * i)) &
+ MLX5_MTR_SUB_POLICY_NUM_MASK;
+ sub_policy_num++;
+ mtr_policy->sub_policy_num &= ~(MLX5_MTR_SUB_POLICY_NUM_MASK <<
+ (MLX5_MTR_SUB_POLICY_NUM_SHIFT * i));
+ mtr_policy->sub_policy_num |=
+ (sub_policy_num & MLX5_MTR_SUB_POLICY_NUM_MASK) <<
+ (MLX5_MTR_SUB_POLICY_NUM_SHIFT * i);
+ if (is_rss) {
+ mtr_policy->is_rss = 1;
+ break;
+ }
+ policy_size += sizeof(struct mlx5_flow_meter_sub_policy *);
+ }
+ rte_spinlock_init(&mtr_policy->sl);
+ ret = mlx5_flow_create_mtr_acts(dev, mtr_policy,
+ policy->actions, error);
+ if (ret)
+ goto policy_add_err;
+ if (!is_rss && !mtr_policy->is_queue) {
+ /* Create policy rules in HW. */
+ ret = mlx5_flow_create_policy_rules(dev, mtr_policy);
+ if (ret)
+ goto policy_add_err;
+ }
+ data.dword = policy_idx;
+ if (!priv->sh->mtrmng->policy_idx_tbl) {
+ priv->sh->mtrmng->policy_idx_tbl =
+ mlx5_l3t_create(MLX5_L3T_TYPE_DWORD);
+ if (!priv->sh->mtrmng->policy_idx_tbl)
+ goto policy_add_err;
+ }
+ if (mlx5_l3t_set_entry(priv->sh->mtrmng->policy_idx_tbl,
+ policy_id, &data))
+ goto policy_add_err;
+ return 0;
+policy_add_err:
+ if (mtr_policy) {
+ ret = __mlx5_flow_meter_policy_delete(dev, policy_id,
+ mtr_policy, error);
+ mlx5_free(mtr_policy);
+ if (ret)
+ return ret;
+ }
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED,
+ NULL, "Failed to create devx policy.");
+}
+
+/**
+ * Callback to delete MTR policy.
*
- * @param[in] action
- * Policy color action.
+ * @param[in] dev
+ * Pointer to Ethernet device.
+ * @param[in] policy_id
+ * Meter policy id.
+ * @param[out] error
+ * Pointer to the error structure.
*
* @return
- * Verbose meter color error type.
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
*/
-static inline enum rte_mtr_error_type
-action2error(enum rte_mtr_policer_action action)
+static int
+mlx5_flow_meter_policy_delete(struct rte_eth_dev *dev,
+ uint32_t policy_id,
+ struct rte_mtr_error *error)
{
- switch (action) {
- case MTR_POLICER_ACTION_COLOR_GREEN:
- return RTE_MTR_ERROR_TYPE_POLICER_ACTION_GREEN;
- case MTR_POLICER_ACTION_COLOR_YELLOW:
- return RTE_MTR_ERROR_TYPE_POLICER_ACTION_YELLOW;
- case MTR_POLICER_ACTION_COLOR_RED:
- return RTE_MTR_ERROR_TYPE_POLICER_ACTION_RED;
- default:
- break;
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct mlx5_flow_meter_policy *mtr_policy;
+ uint32_t policy_idx;
+ int ret;
+
+ if (policy_id == priv->sh->mtrmng->def_policy_id) {
+ if (priv->sh->mtrmng->def_policy_ref_cnt > 0)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL,
+ "Meter policy object is being used.");
+ priv->sh->mtrmng->def_policy_id = MLX5_INVALID_POLICY_ID;
+ return 0;
}
- return RTE_MTR_ERROR_TYPE_UNSPECIFIED;
+ mtr_policy = mlx5_flow_meter_policy_find(dev, policy_id, &policy_idx);
+ if (!mtr_policy)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL,
+ "Meter policy id is invalid. ");
+ ret = __mlx5_flow_meter_policy_delete(dev, policy_id, mtr_policy,
+ error);
+ if (ret)
+ return ret;
+ mlx5_free(mtr_policy);
+ return 0;
}
/**
struct rte_mtr_params *params,
struct rte_mtr_error *error)
{
- static enum rte_mtr_policer_action
- valid_recol_action[RTE_COLORS] = {
- MTR_POLICER_ACTION_COLOR_GREEN,
- MTR_POLICER_ACTION_COLOR_YELLOW,
- MTR_POLICER_ACTION_COLOR_RED };
- int i;
-
+ /* Meter must use global drop action. */
+ if (!priv->sh->dr_drop_action)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_MTR_PARAMS,
+ NULL,
+ "No drop action ready for meter.");
/* Meter params must not be NULL. */
if (params == NULL)
return -rte_mtr_error_set(error, EINVAL,
NULL,
"Previous meter color "
"not supported.");
- /* Validate policer settings. */
- for (i = 0; i < RTE_COLORS; i++)
- if (params->action[i] != valid_recol_action[i] &&
- params->action[i] != MTR_POLICER_ACTION_DROP)
- return -rte_mtr_error_set
- (error, ENOTSUP,
- action2error(params->action[i]), NULL,
- "Recolor action not supported.");
+ if (params->meter_policy_id == MLX5_INVALID_POLICY_ID)
+ return -rte_mtr_error_set(error, ENOENT,
+ RTE_MTR_ERROR_TYPE_METER_POLICY_ID,
+ NULL, "Meter policy id not valid.");
/* Validate meter id. */
- if (mlx5_flow_meter_find(priv, meter_id))
+ if (mlx5_flow_meter_find(priv, meter_id, NULL))
return -rte_mtr_error_set(error, EEXIST,
- RTE_MTR_ERROR_TYPE_MTR_ID, NULL,
- "Meter object already exists.");
+ RTE_MTR_ERROR_TYPE_MTR_ID, NULL,
+ "Meter object already exists.");
return 0;
}
*/
static int
mlx5_flow_meter_action_modify(struct mlx5_priv *priv,
- struct mlx5_flow_meter *fm,
+ struct mlx5_flow_meter_info *fm,
const struct mlx5_flow_meter_srtcm_rfc2697_prm *srtcm,
- uint64_t modify_bits, uint32_t active_state)
+ uint64_t modify_bits, uint32_t active_state, uint32_t is_enable)
{
#ifdef HAVE_MLX5_DR_CREATE_ACTION_FLOW_METER
uint32_t in[MLX5_ST_SZ_DW(flow_meter_parameters)] = { 0 };
uint32_t *attr;
struct mlx5dv_dr_flow_meter_attr mod_attr = { 0 };
int ret;
+ struct mlx5_aso_mtr *aso_mtr = NULL;
+ uint32_t cbs_cir, ebs_eir, val;
- /* Fill command parameters. */
- mod_attr.reg_c_index = priv->mtr_color_reg - REG_C_0;
- mod_attr.flow_meter_parameter = in;
- mod_attr.flow_meter_parameter_sz = fm->mfts->fmp_size;
- if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_ACTIVE)
- mod_attr.active = !!active_state;
- else
- mod_attr.active = 0;
- attr = in;
- if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS) {
- MLX5_SET(flow_meter_parameters,
- attr, cbs_exponent, srtcm->cbs_exponent);
- MLX5_SET(flow_meter_parameters,
- attr, cbs_mantissa, srtcm->cbs_mantissa);
- }
- if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR) {
- MLX5_SET(flow_meter_parameters,
- attr, cir_exponent, srtcm->cir_exponent);
- MLX5_SET(flow_meter_parameters,
- attr, cir_mantissa, srtcm->cir_mantissa);
- }
- if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_EBS) {
- MLX5_SET(flow_meter_parameters,
- attr, ebs_exponent, srtcm->ebs_exponent);
- MLX5_SET(flow_meter_parameters,
- attr, ebs_mantissa, srtcm->ebs_mantissa);
- }
- /* Apply modifications to meter only if it was created. */
- if (fm->mfts->meter_action) {
- ret = mlx5_glue->dv_modify_flow_action_meter
- (fm->mfts->meter_action, &mod_attr,
- rte_cpu_to_be_64(modify_bits));
+ if (priv->sh->meter_aso_en) {
+ fm->is_enable = !!is_enable;
+ aso_mtr = container_of(fm, struct mlx5_aso_mtr, fm);
+ ret = mlx5_aso_meter_update_by_wqe(priv->sh, aso_mtr);
if (ret)
return ret;
+ ret = mlx5_aso_mtr_wait(priv->sh, aso_mtr);
+ if (ret)
+ return ret;
+ } else {
+ /* Fill command parameters. */
+ mod_attr.reg_c_index = priv->mtr_color_reg - REG_C_0;
+ mod_attr.flow_meter_parameter = in;
+ mod_attr.flow_meter_parameter_sz =
+ MLX5_ST_SZ_BYTES(flow_meter_parameters);
+ if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_ACTIVE)
+ mod_attr.active = !!active_state;
+ else
+ mod_attr.active = 0;
+ attr = in;
+ cbs_cir = rte_be_to_cpu_32(srtcm->cbs_cir);
+ ebs_eir = rte_be_to_cpu_32(srtcm->ebs_eir);
+ if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS) {
+ val = (cbs_cir >> ASO_DSEG_CBS_EXP_OFFSET) &
+ ASO_DSEG_EXP_MASK;
+ MLX5_SET(flow_meter_parameters, attr,
+ cbs_exponent, val);
+ val = (cbs_cir >> ASO_DSEG_CBS_MAN_OFFSET) &
+ ASO_DSEG_MAN_MASK;
+ MLX5_SET(flow_meter_parameters, attr,
+ cbs_mantissa, val);
+ }
+ if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR) {
+ val = (cbs_cir >> ASO_DSEG_CIR_EXP_OFFSET) &
+ ASO_DSEG_EXP_MASK;
+ MLX5_SET(flow_meter_parameters, attr,
+ cir_exponent, val);
+ val = cbs_cir & ASO_DSEG_MAN_MASK;
+ MLX5_SET(flow_meter_parameters, attr,
+ cir_mantissa, val);
+ }
+ if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_EBS) {
+ val = (ebs_eir >> ASO_DSEG_EBS_EXP_OFFSET) &
+ ASO_DSEG_EXP_MASK;
+ MLX5_SET(flow_meter_parameters, attr,
+ ebs_exponent, val);
+ val = (ebs_eir >> ASO_DSEG_EBS_MAN_OFFSET) &
+ ASO_DSEG_MAN_MASK;
+ MLX5_SET(flow_meter_parameters, attr,
+ ebs_mantissa, val);
+ }
+ /* Apply modifications to meter only if it was created. */
+ if (fm->meter_action) {
+ ret = mlx5_glue->dv_modify_flow_action_meter
+ (fm->meter_action, &mod_attr,
+ rte_cpu_to_be_64(modify_bits));
+ if (ret)
+ return ret;
+ }
+ /* Update succeedded modify meter parameters. */
+ if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_ACTIVE)
+ fm->active_state = !!active_state;
}
- /* Update succeedded modify meter parameters. */
- if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_ACTIVE)
- fm->active_state = !!active_state;
- attr = fm->mfts->fmp;
- if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS) {
- MLX5_SET(flow_meter_parameters,
- attr, cbs_exponent, srtcm->cbs_exponent);
- MLX5_SET(flow_meter_parameters,
- attr, cbs_mantissa, srtcm->cbs_mantissa);
- }
- if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR) {
- MLX5_SET(flow_meter_parameters,
- attr, cir_exponent, srtcm->cir_exponent);
- MLX5_SET(flow_meter_parameters,
- attr, cir_mantissa, srtcm->cir_mantissa);
- }
- if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_EBS) {
- MLX5_SET(flow_meter_parameters,
- attr, ebs_exponent, srtcm->ebs_exponent);
- MLX5_SET(flow_meter_parameters,
- attr, ebs_mantissa, srtcm->ebs_mantissa);
- }
-
return 0;
#else
(void)priv;
(void)srtcm;
(void)modify_bits;
(void)active_state;
+ (void)is_enable;
return -ENOTSUP;
#endif
}
+static int
+mlx5_flow_meter_stats_enable_update(struct rte_eth_dev *dev,
+ struct mlx5_flow_meter_info *fm,
+ uint64_t stats_mask)
+{
+ fm->bytes_dropped =
+ (stats_mask & RTE_MTR_STATS_N_BYTES_DROPPED) ? 1 : 0;
+ fm->pkts_dropped = (stats_mask & RTE_MTR_STATS_N_PKTS_DROPPED) ? 1 : 0;
+ if (fm->bytes_dropped || fm->pkts_dropped) {
+ if (!fm->drop_cnt) {
+ /* Alloc policer counters. */
+ fm->drop_cnt = mlx5_counter_alloc(dev);
+ if (!fm->drop_cnt)
+ return -1;
+ }
+ } else {
+ if (fm->drop_cnt) {
+ mlx5_counter_free(dev, fm->drop_cnt);
+ fm->drop_cnt = 0;
+ }
+ }
+ return 0;
+}
+
/**
* Create meter rules.
*
struct rte_mtr_error *error)
{
struct mlx5_priv *priv = dev->data->dev_private;
- struct mlx5_flow_meters *fms = &priv->flow_meters;
+ struct mlx5_legacy_flow_meters *fms = &priv->flow_meters;
struct mlx5_flow_meter_profile *fmp;
- struct mlx5_flow_meter *fm;
- const struct rte_flow_attr attr = {
- .ingress = 1,
- .egress = 1,
- .transfer = priv->config.dv_esw_en ? 1 : 0,
- };
+ struct mlx5_flow_meter_info *fm;
+ struct mlx5_legacy_flow_meter *legacy_fm;
+ struct mlx5_flow_meter_policy *mtr_policy = NULL;
+ struct mlx5_indexed_pool_config flow_ipool_cfg = {
+ .size = 0,
+ .trunk_size = 64,
+ .need_lock = 1,
+ .type = "mlx5_flow_mtr_flow_id_pool",
+ };
+ struct mlx5_aso_mtr *aso_mtr;
+ uint32_t mtr_idx, policy_idx;
+ union mlx5_l3t_data data;
int ret;
- unsigned int i;
- uint32_t idx = 0;
+ uint8_t domain_bitmap;
+ uint8_t mtr_id_bits;
+ uint8_t mtr_reg_bits = priv->mtr_reg_share ?
+ MLX5_MTR_IDLE_BITS_IN_COLOR_REG : MLX5_REG_BITS;
if (!priv->mtr_en)
return -rte_mtr_error_set(error, ENOTSUP,
- RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
- "Meter is not supported");
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Meter is not supported");
/* Validate the parameters. */
ret = mlx5_flow_meter_validate(priv, meter_id, params, error);
if (ret)
fmp = mlx5_flow_meter_profile_find(priv, params->meter_profile_id);
if (fmp == NULL)
return -rte_mtr_error_set(error, ENOENT,
- RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
- NULL, "Meter profile id not valid.");
+ RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
+ NULL, "Meter profile id not valid.");
+ /* Meter policy must exist. */
+ if (params->meter_policy_id == priv->sh->mtrmng->def_policy_id) {
+ __atomic_add_fetch
+ (&priv->sh->mtrmng->def_policy_ref_cnt,
+ 1, __ATOMIC_RELAXED);
+ domain_bitmap = MLX5_MTR_ALL_DOMAIN_BIT;
+ if (!priv->config.dv_esw_en)
+ domain_bitmap &= ~MLX5_MTR_DOMAIN_TRANSFER_BIT;
+ } else {
+ mtr_policy = mlx5_flow_meter_policy_find(dev,
+ params->meter_policy_id, &policy_idx);
+ if (!priv->sh->meter_aso_en)
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Part of the policies cannot be "
+ "supported without ASO ");
+ if (!mtr_policy)
+ return -rte_mtr_error_set(error, ENOENT,
+ RTE_MTR_ERROR_TYPE_METER_POLICY_ID,
+ NULL, "Meter policy id not valid.");
+ domain_bitmap = (mtr_policy->ingress ?
+ MLX5_MTR_DOMAIN_INGRESS_BIT : 0) |
+ (mtr_policy->egress ?
+ MLX5_MTR_DOMAIN_EGRESS_BIT : 0) |
+ (mtr_policy->transfer ?
+ MLX5_MTR_DOMAIN_TRANSFER_BIT : 0);
+ }
/* Allocate the flow meter memory. */
- fm = mlx5_ipool_zmalloc(priv->sh->ipool[MLX5_IPOOL_MTR], &idx);
- if (fm == NULL)
- return -rte_mtr_error_set(error, ENOMEM,
- RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
- "Memory alloc failed for meter.");
- fm->idx = idx;
+ if (priv->sh->meter_aso_en) {
+ mtr_idx = mlx5_flow_mtr_alloc(dev);
+ if (!mtr_idx)
+ return -rte_mtr_error_set(error, ENOMEM,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Memory alloc failed for meter.");
+ aso_mtr = mlx5_aso_meter_by_idx(priv, mtr_idx);
+ fm = &aso_mtr->fm;
+ } else {
+ legacy_fm = mlx5_ipool_zmalloc
+ (priv->sh->ipool[MLX5_IPOOL_MTR], &mtr_idx);
+ if (legacy_fm == NULL)
+ return -rte_mtr_error_set(error, ENOMEM,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Memory alloc failed for meter.");
+ legacy_fm->idx = mtr_idx;
+ fm = &legacy_fm->fm;
+ }
+ mtr_id_bits = MLX5_REG_BITS - __builtin_clz(mtr_idx);
+ if ((mtr_id_bits + priv->sh->mtrmng->max_mtr_flow_bits) >
+ mtr_reg_bits) {
+ DRV_LOG(ERR, "Meter number exceeds max limit.");
+ goto error;
+ }
+ if (mtr_id_bits > priv->sh->mtrmng->max_mtr_bits)
+ priv->sh->mtrmng->max_mtr_bits = mtr_id_bits;
/* Fill the flow meter parameters. */
fm->meter_id = meter_id;
+ fm->policy_id = params->meter_policy_id;
fm->profile = fmp;
- memcpy(fm->action, params->action, sizeof(params->action));
- fm->stats_mask = params->stats_mask;
-
- /* Alloc policer counters. */
- for (i = 0; i < RTE_DIM(fm->policer_stats.cnt); i++) {
- fm->policer_stats.cnt[i] = mlx5_counter_alloc(dev);
- if (!fm->policer_stats.cnt[i])
- goto error;
- }
- fm->mfts = mlx5_flow_create_mtr_tbls(dev, fm);
- if (!fm->mfts)
+ if (mlx5_flow_meter_stats_enable_update(dev, fm, params->stats_mask))
goto error;
- ret = mlx5_flow_create_policer_rules(dev, fm, &attr);
- if (ret)
+ if (mlx5_flow_create_mtr_tbls(dev, fm, mtr_idx, domain_bitmap))
goto error;
/* Add to the flow meter list. */
- TAILQ_INSERT_TAIL(fms, fm, next);
+ if (!priv->sh->meter_aso_en)
+ TAILQ_INSERT_TAIL(fms, legacy_fm, next);
+ /* Add to the flow meter list. */
fm->active_state = 1; /* Config meter starts as active. */
+ fm->is_enable = 1;
fm->shared = !!shared;
- fm->policer_stats.stats_mask = params->stats_mask;
- fm->profile->ref_cnt++;
+ __atomic_add_fetch(&fm->profile->ref_cnt, 1, __ATOMIC_RELAXED);
+ if (params->meter_policy_id == priv->sh->mtrmng->def_policy_id) {
+ fm->def_policy = 1;
+ fm->flow_ipool = mlx5_ipool_create(&flow_ipool_cfg);
+ if (!fm->flow_ipool)
+ goto error;
+ }
+ rte_spinlock_init(&fm->sl);
+ /* If ASO meter supported, update ASO flow meter by wqe. */
+ if (priv->sh->meter_aso_en) {
+ aso_mtr = container_of(fm, struct mlx5_aso_mtr, fm);
+ ret = mlx5_aso_meter_update_by_wqe(priv->sh, aso_mtr);
+ if (ret)
+ goto error;
+ if (!priv->mtr_idx_tbl) {
+ priv->mtr_idx_tbl =
+ mlx5_l3t_create(MLX5_L3T_TYPE_DWORD);
+ if (!priv->mtr_idx_tbl)
+ goto error;
+ }
+ data.dword = mtr_idx;
+ if (mlx5_l3t_set_entry(priv->mtr_idx_tbl, meter_id, &data))
+ goto error;
+ }
+ if (mtr_policy)
+ __atomic_add_fetch(&mtr_policy->ref_cnt, 1, __ATOMIC_RELAXED);
return 0;
error:
- mlx5_flow_destroy_policer_rules(dev, fm, &attr);
- mlx5_flow_destroy_mtr_tbls(dev, fm->mfts);
+ mlx5_flow_destroy_mtr_tbls(dev, fm);
/* Free policer counters. */
- for (i = 0; i < RTE_DIM(fm->policer_stats.cnt); i++)
- if (fm->policer_stats.cnt[i])
- mlx5_counter_free(dev, fm->policer_stats.cnt[i]);
- mlx5_ipool_free(priv->sh->ipool[MLX5_IPOOL_MTR], idx);
- return -rte_mtr_error_set(error, -ret,
- RTE_MTR_ERROR_TYPE_UNSPECIFIED,
- NULL, "Failed to create devx meter.");
+ if (fm->drop_cnt)
+ mlx5_counter_free(dev, fm->drop_cnt);
+ if (priv->sh->meter_aso_en)
+ mlx5_flow_mtr_free(dev, mtr_idx);
+ else
+ mlx5_ipool_free(priv->sh->ipool[MLX5_IPOOL_MTR], mtr_idx);
+ return -rte_mtr_error_set(error, ENOTSUP,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED,
+ NULL, "Failed to create devx meter.");
+}
+
+static int
+mlx5_flow_meter_params_flush(struct rte_eth_dev *dev,
+ struct mlx5_flow_meter_info *fm,
+ uint32_t mtr_idx)
+{
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct mlx5_legacy_flow_meters *fms = &priv->flow_meters;
+ struct mlx5_flow_meter_profile *fmp;
+ struct mlx5_legacy_flow_meter *legacy_fm = NULL;
+ struct mlx5_flow_meter_policy *mtr_policy;
+
+ /* Meter object must not have any owner. */
+ MLX5_ASSERT(!fm->ref_cnt);
+ /* Get meter profile. */
+ fmp = fm->profile;
+ if (fmp == NULL)
+ return -1;
+ /* Update dependencies. */
+ __atomic_sub_fetch(&fmp->ref_cnt, 1, __ATOMIC_RELAXED);
+ fm->profile = NULL;
+ /* Remove from list. */
+ if (!priv->sh->meter_aso_en) {
+ legacy_fm = container_of(fm,
+ struct mlx5_legacy_flow_meter, fm);
+ TAILQ_REMOVE(fms, legacy_fm, next);
+ }
+ /* Free drop counters. */
+ if (fm->drop_cnt)
+ mlx5_counter_free(dev, fm->drop_cnt);
+ /* Free meter flow table. */
+ if (fm->flow_ipool) {
+ mlx5_ipool_destroy(fm->flow_ipool);
+ fm->flow_ipool = 0;
+ }
+ mlx5_flow_destroy_mtr_tbls(dev, fm);
+ if (fm->def_policy)
+ __atomic_sub_fetch(&priv->sh->mtrmng->def_policy_ref_cnt,
+ 1, __ATOMIC_RELAXED);
+ if (priv->sh->meter_aso_en) {
+ if (!fm->def_policy) {
+ mtr_policy = mlx5_flow_meter_policy_find(dev,
+ fm->policy_id, NULL);
+ if (mtr_policy)
+ __atomic_sub_fetch(&mtr_policy->ref_cnt,
+ 1, __ATOMIC_RELAXED);
+ fm->policy_id = 0;
+ }
+ fm->def_policy = 0;
+ if (mlx5_l3t_clear_entry(priv->mtr_idx_tbl, fm->meter_id))
+ return -1;
+ mlx5_flow_mtr_free(dev, mtr_idx);
+ } else {
+ mlx5_ipool_free(priv->sh->ipool[MLX5_IPOOL_MTR],
+ legacy_fm->idx);
+ }
+ return 0;
}
/**
struct rte_mtr_error *error)
{
struct mlx5_priv *priv = dev->data->dev_private;
- struct mlx5_flow_meters *fms = &priv->flow_meters;
- struct mlx5_flow_meter_profile *fmp;
- struct mlx5_flow_meter *fm;
- const struct rte_flow_attr attr = {
- .ingress = 1,
- .egress = 1,
- .transfer = priv->config.dv_esw_en ? 1 : 0,
- };
- unsigned int i;
+ struct mlx5_flow_meter_info *fm;
+ uint32_t mtr_idx = 0;
if (!priv->mtr_en)
return -rte_mtr_error_set(error, ENOTSUP,
- RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
+ RTE_MTR_ERROR_TYPE_UNSPECIFIED,
+ NULL,
"Meter is not supported");
/* Meter object must exist. */
- fm = mlx5_flow_meter_find(priv, meter_id);
+ fm = mlx5_flow_meter_find(priv, meter_id, &mtr_idx);
if (fm == NULL)
return -rte_mtr_error_set(error, ENOENT,
RTE_MTR_ERROR_TYPE_MTR_ID,
- NULL, "Meter object id not valid.");
+ NULL,
+ "Meter object id not valid.");
/* Meter object must not have any owner. */
if (fm->ref_cnt > 0)
return -rte_mtr_error_set(error, EBUSY,
RTE_MTR_ERROR_TYPE_UNSPECIFIED,
- NULL, "Meter object is being used.");
- /* Get the meter profile. */
- fmp = fm->profile;
- MLX5_ASSERT(fmp);
- /* Update dependencies. */
- fmp->ref_cnt--;
- /* Remove from the flow meter list. */
- TAILQ_REMOVE(fms, fm, next);
- /* Free policer counters. */
- for (i = 0; i < RTE_DIM(fm->policer_stats.cnt); i++)
- if (fm->policer_stats.cnt[i])
- mlx5_counter_free(dev, fm->policer_stats.cnt[i]);
- /* Free meter flow table */
- mlx5_flow_destroy_policer_rules(dev, fm, &attr);
- mlx5_flow_destroy_mtr_tbls(dev, fm->mfts);
- mlx5_ipool_free(priv->sh->ipool[MLX5_IPOOL_MTR], fm->idx);
+ NULL,
+ "Meter object is being used.");
+ /* Destroy the meter profile. */
+ if (mlx5_flow_meter_params_flush(dev, fm, mtr_idx))
+ return -rte_mtr_error_set(error, EINVAL,
+ RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
+ NULL,
+ "MTR object meter profile invalid.");
return 0;
}
*/
static int
mlx5_flow_meter_modify_state(struct mlx5_priv *priv,
- struct mlx5_flow_meter *fm,
+ struct mlx5_flow_meter_info *fm,
uint32_t new_state,
struct rte_mtr_error *error)
{
static const struct mlx5_flow_meter_srtcm_rfc2697_prm srtcm = {
- .cbs_exponent = 20,
- .cbs_mantissa = 191,
- .cir_exponent = 0,
- .cir_mantissa = 200,
- .ebs_exponent = 0,
- .ebs_mantissa = 0,
+ .cbs_cir = RTE_BE32(MLX5_IFC_FLOW_METER_DISABLE_CBS_CIR_VAL),
+ .ebs_eir = 0,
};
uint64_t modify_bits = MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS |
MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR;
int ret;
if (new_state == MLX5_FLOW_METER_DISABLE)
- ret = mlx5_flow_meter_action_modify(priv, fm, &srtcm,
- modify_bits, 0);
+ ret = mlx5_flow_meter_action_modify(priv, fm,
+ &srtcm, modify_bits, 0, 0);
else
ret = mlx5_flow_meter_action_modify(priv, fm,
&fm->profile->srtcm_prm,
- modify_bits, 0);
+ modify_bits, 0, 1);
if (ret)
return -rte_mtr_error_set(error, -ret,
RTE_MTR_ERROR_TYPE_MTR_PARAMS,
struct rte_mtr_error *error)
{
struct mlx5_priv *priv = dev->data->dev_private;
- struct mlx5_flow_meter *fm;
+ struct mlx5_flow_meter_info *fm;
int ret;
if (!priv->mtr_en)
RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
"Meter is not supported");
/* Meter object must exist. */
- fm = mlx5_flow_meter_find(priv, meter_id);
+ fm = mlx5_flow_meter_find(priv, meter_id, NULL);
if (fm == NULL)
return -rte_mtr_error_set(error, ENOENT,
RTE_MTR_ERROR_TYPE_MTR_ID,
struct rte_mtr_error *error)
{
struct mlx5_priv *priv = dev->data->dev_private;
- struct mlx5_flow_meter *fm;
+ struct mlx5_flow_meter_info *fm;
int ret;
if (!priv->mtr_en)
RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
"Meter is not supported");
/* Meter object must exist. */
- fm = mlx5_flow_meter_find(priv, meter_id);
+ fm = mlx5_flow_meter_find(priv, meter_id, NULL);
if (fm == NULL)
return -rte_mtr_error_set(error, ENOENT,
RTE_MTR_ERROR_TYPE_MTR_ID,
struct mlx5_priv *priv = dev->data->dev_private;
struct mlx5_flow_meter_profile *fmp;
struct mlx5_flow_meter_profile *old_fmp;
- struct mlx5_flow_meter *fm;
+ struct mlx5_flow_meter_info *fm;
uint64_t modify_bits = MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS |
MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR;
int ret;
RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
NULL, "Meter profile not found.");
/* Meter object must exist. */
- fm = mlx5_flow_meter_find(priv, meter_id);
+ fm = mlx5_flow_meter_find(priv, meter_id, NULL);
if (fm == NULL)
return -rte_mtr_error_set(error, ENOENT,
RTE_MTR_ERROR_TYPE_MTR_ID,
if (fm->active_state == MLX5_FLOW_METER_DISABLE)
return 0;
ret = mlx5_flow_meter_action_modify(priv, fm, &fm->profile->srtcm_prm,
- modify_bits, fm->active_state);
+ modify_bits, fm->active_state, 1);
if (ret) {
fm->profile = old_fmp;
return -rte_mtr_error_set(error, -ret,
struct rte_mtr_error *error)
{
struct mlx5_priv *priv = dev->data->dev_private;
- struct mlx5_flow_meter *fm;
+ struct mlx5_flow_meter_info *fm;
if (!priv->mtr_en)
return -rte_mtr_error_set(error, ENOTSUP,
RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
"Meter is not supported");
/* Meter object must exist. */
- fm = mlx5_flow_meter_find(priv, meter_id);
+ fm = mlx5_flow_meter_find(priv, meter_id, NULL);
if (fm == NULL)
return -rte_mtr_error_set(error, ENOENT,
RTE_MTR_ERROR_TYPE_MTR_ID,
NULL, "Meter object id not valid.");
- fm->policer_stats.stats_mask = stats_mask;
+ if (mlx5_flow_meter_stats_enable_update(dev, fm, stats_mask))
+ return -rte_mtr_error_set(error, ENOENT,
+ RTE_MTR_ERROR_TYPE_MTR_ID,
+ NULL, "Fail to allocate "
+ "counter for meter.");
return 0;
}
int clear,
struct rte_mtr_error *error)
{
- static uint64_t meter2mask[RTE_MTR_DROPPED + 1] = {
- RTE_MTR_STATS_N_PKTS_GREEN | RTE_MTR_STATS_N_BYTES_GREEN,
- RTE_MTR_STATS_N_PKTS_YELLOW | RTE_MTR_STATS_N_BYTES_YELLOW,
- RTE_MTR_STATS_N_PKTS_RED | RTE_MTR_STATS_N_BYTES_RED,
- RTE_MTR_STATS_N_PKTS_DROPPED | RTE_MTR_STATS_N_BYTES_DROPPED
- };
struct mlx5_priv *priv = dev->data->dev_private;
- struct mlx5_flow_meter *fm;
- struct mlx5_flow_policer_stats *ps;
- uint64_t pkts_dropped = 0;
- uint64_t bytes_dropped = 0;
+ struct mlx5_flow_meter_info *fm;
uint64_t pkts;
uint64_t bytes;
- int i;
int ret = 0;
if (!priv->mtr_en)
RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
"Meter is not supported");
/* Meter object must exist. */
- fm = mlx5_flow_meter_find(priv, meter_id);
+ fm = mlx5_flow_meter_find(priv, meter_id, NULL);
if (fm == NULL)
return -rte_mtr_error_set(error, ENOENT,
RTE_MTR_ERROR_TYPE_MTR_ID,
NULL, "Meter object id not valid.");
- ps = &fm->policer_stats;
- *stats_mask = ps->stats_mask;
- for (i = 0; i < RTE_MTR_DROPPED; i++) {
- if (*stats_mask & meter2mask[i]) {
- ret = mlx5_counter_query(dev, ps->cnt[i], clear, &pkts,
+ *stats_mask = 0;
+ if (fm->bytes_dropped)
+ *stats_mask |= RTE_MTR_STATS_N_BYTES_DROPPED;
+ if (fm->pkts_dropped)
+ *stats_mask |= RTE_MTR_STATS_N_PKTS_DROPPED;
+ memset(stats, 0, sizeof(*stats));
+ if (fm->drop_cnt) {
+ ret = mlx5_counter_query(dev, fm->drop_cnt, clear, &pkts,
&bytes);
- if (ret)
- goto error;
- if (fm->action[i] == MTR_POLICER_ACTION_DROP) {
- pkts_dropped += pkts;
- bytes_dropped += bytes;
- }
- /* If need to read the packets, set it. */
- if ((1 << i) & (*stats_mask & meter2mask[i]))
- stats->n_pkts[i] = pkts;
- /* If need to read the bytes, set it. */
- if ((1 << (RTE_MTR_DROPPED + 1 + i)) &
- (*stats_mask & meter2mask[i]))
- stats->n_bytes[i] = bytes;
- }
- }
- /* Dropped packets/bytes are treated differently. */
- if (*stats_mask & meter2mask[i]) {
- ret = mlx5_counter_query(dev, ps->cnt[i], clear, &pkts,
- &bytes);
if (ret)
goto error;
- pkts += pkts_dropped;
- bytes += bytes_dropped;
/* If need to read the packets, set it. */
- if ((*stats_mask & meter2mask[i]) &
- RTE_MTR_STATS_N_PKTS_DROPPED)
+ if (fm->pkts_dropped)
stats->n_pkts_dropped = pkts;
/* If need to read the bytes, set it. */
- if ((*stats_mask & meter2mask[i]) &
- RTE_MTR_STATS_N_BYTES_DROPPED)
+ if (fm->bytes_dropped)
stats->n_bytes_dropped = bytes;
}
return 0;
error:
return -rte_mtr_error_set(error, ret, RTE_MTR_ERROR_TYPE_STATS, NULL,
- "Failed to read policer counters.");
+ "Failed to read meter drop counters.");
}
static const struct rte_mtr_ops mlx5_flow_mtr_ops = {
.capabilities_get = mlx5_flow_mtr_cap_get,
.meter_profile_add = mlx5_flow_meter_profile_add,
.meter_profile_delete = mlx5_flow_meter_profile_delete,
+ .meter_policy_validate = mlx5_flow_meter_policy_validate,
+ .meter_policy_add = mlx5_flow_meter_policy_add,
+ .meter_policy_delete = mlx5_flow_meter_policy_delete,
.create = mlx5_flow_meter_create,
.destroy = mlx5_flow_meter_destroy,
.meter_enable = mlx5_flow_meter_enable,
.meter_disable = mlx5_flow_meter_disable,
.meter_profile_update = mlx5_flow_meter_profile_update,
.meter_dscp_table_update = NULL,
- .policer_actions_update = NULL,
.stats_update = mlx5_flow_meter_stats_update,
.stats_read = mlx5_flow_meter_stats_read,
};
* Pointer to mlx5_priv.
* @param meter_id
* Meter id.
+ * @param mtr_idx
+ * Pointer to Meter index.
*
* @return
- * Pointer to the profile found on success, NULL otherwise.
+ * Pointer to the meter info found on success, NULL otherwise.
*/
-struct mlx5_flow_meter *
-mlx5_flow_meter_find(struct mlx5_priv *priv, uint32_t meter_id)
+struct mlx5_flow_meter_info *
+mlx5_flow_meter_find(struct mlx5_priv *priv, uint32_t meter_id,
+ uint32_t *mtr_idx)
{
- struct mlx5_flow_meters *fms = &priv->flow_meters;
- struct mlx5_flow_meter *fm;
+ struct mlx5_legacy_flow_meter *legacy_fm;
+ struct mlx5_legacy_flow_meters *fms = &priv->flow_meters;
+ struct mlx5_aso_mtr *aso_mtr;
+ struct mlx5_aso_mtr_pools_mng *pools_mng =
+ &priv->sh->mtrmng->pools_mng;
+ union mlx5_l3t_data data;
- TAILQ_FOREACH(fm, fms, next)
- if (meter_id == fm->meter_id)
- return fm;
+ if (priv->sh->meter_aso_en) {
+ rte_spinlock_lock(&pools_mng->mtrsl);
+ if (!pools_mng->n_valid || !priv->mtr_idx_tbl) {
+ rte_spinlock_unlock(&pools_mng->mtrsl);
+ return NULL;
+ }
+ if (mlx5_l3t_get_entry(priv->mtr_idx_tbl, meter_id, &data) ||
+ !data.dword) {
+ rte_spinlock_unlock(&pools_mng->mtrsl);
+ return NULL;
+ }
+ if (mtr_idx)
+ *mtr_idx = data.dword;
+ aso_mtr = mlx5_aso_meter_by_idx(priv, data.dword);
+ /* Remove reference taken by the mlx5_l3t_get_entry. */
+ mlx5_l3t_clear_entry(priv->mtr_idx_tbl, meter_id);
+ rte_spinlock_unlock(&pools_mng->mtrsl);
+ if (!aso_mtr || aso_mtr->state == ASO_METER_FREE)
+ return NULL;
+ return &aso_mtr->fm;
+ }
+ TAILQ_FOREACH(legacy_fm, fms, next)
+ if (meter_id == legacy_fm->fm.meter_id) {
+ if (mtr_idx)
+ *mtr_idx = legacy_fm->idx;
+ return &legacy_fm->fm;
+ }
return NULL;
}
+/**
+ * Find meter by index.
+ *
+ * @param priv
+ * Pointer to mlx5_priv.
+ * @param idx
+ * Meter index.
+ *
+ * @return
+ * Pointer to the meter info found on success, NULL otherwise.
+ */
+struct mlx5_flow_meter_info *
+flow_dv_meter_find_by_idx(struct mlx5_priv *priv, uint32_t idx)
+{
+ struct mlx5_aso_mtr *aso_mtr;
+
+ if (priv->sh->meter_aso_en) {
+ aso_mtr = mlx5_aso_meter_by_idx(priv, idx);
+ if (!aso_mtr)
+ return NULL;
+ return &aso_mtr->fm;
+ } else {
+ return mlx5_ipool_get(priv->sh->ipool[MLX5_IPOOL_MTR], idx);
+ }
+}
+
/**
* Attach meter to flow.
* Unidirectional Meter creation can only be done
*
* @param [in] priv
* Pointer to mlx5 private data.
- * @param [in] meter_id
- * Flow meter id.
+ * @param[in] fm
+ * Pointer to flow meter.
* @param [in] attr
* Pointer to flow attributes.
* @param [out] error
* Pointer to error structure.
*
- * @return the flow meter pointer, NULL otherwise.
+ * @return
+ * 0 on success, a negative errno value otherwise and rte_errno is set.
*/
-struct mlx5_flow_meter *
-mlx5_flow_meter_attach(struct mlx5_priv *priv, uint32_t meter_id,
+int
+mlx5_flow_meter_attach(struct mlx5_priv *priv,
+ struct mlx5_flow_meter_info *fm,
const struct rte_flow_attr *attr,
struct rte_flow_error *error)
{
- struct mlx5_flow_meter *fm;
+ int ret = 0;
- fm = mlx5_flow_meter_find(priv, meter_id);
- if (fm == NULL) {
- rte_flow_error_set(error, ENOENT,
+ if (priv->sh->meter_aso_en) {
+ struct mlx5_aso_mtr *aso_mtr;
+
+ aso_mtr = container_of(fm, struct mlx5_aso_mtr, fm);
+ if (mlx5_aso_mtr_wait(priv->sh, aso_mtr)) {
+ return rte_flow_error_set(error, ENOENT,
+ RTE_FLOW_ERROR_TYPE_UNSPECIFIED,
+ NULL,
+ "Timeout in meter configuration");
+ }
+ rte_spinlock_lock(&fm->sl);
+ if (fm->shared || !fm->ref_cnt) {
+ fm->ref_cnt++;
+ } else {
+ rte_flow_error_set(error, EINVAL,
RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
- "Meter object id not valid");
- goto error;
- }
- if (!fm->shared && fm->ref_cnt) {
- DRV_LOG(ERR, "Cannot share a non-shared meter.");
- rte_flow_error_set(error, EINVAL,
- RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
- "Meter can't be shared");
- goto error;
- }
- if (!fm->ref_cnt++) {
- MLX5_ASSERT(!fm->mfts->meter_action);
- fm->ingress = attr->ingress;
- fm->egress = attr->egress;
- fm->transfer = attr->transfer;
- /* This also creates the meter object. */
- fm->mfts->meter_action = mlx5_flow_meter_action_create(priv,
- fm);
- if (!fm->mfts->meter_action)
- goto error_detach;
+ "Meter cannot be shared");
+ ret = -1;
+ }
+ rte_spinlock_unlock(&fm->sl);
} else {
- MLX5_ASSERT(fm->mfts->meter_action);
- if (attr->transfer != fm->transfer ||
- attr->ingress != fm->ingress ||
- attr->egress != fm->egress) {
- DRV_LOG(ERR, "meter I/O attributes do not "
- "match flow I/O attributes.");
- goto error_detach;
+ rte_spinlock_lock(&fm->sl);
+ if (fm->meter_action) {
+ if (fm->shared &&
+ attr->transfer == fm->transfer &&
+ attr->ingress == fm->ingress &&
+ attr->egress == fm->egress) {
+ fm->ref_cnt++;
+ } else {
+ rte_flow_error_set(error, EINVAL,
+ RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
+ fm->shared ?
+ "Meter attr not match." :
+ "Meter cannot be shared.");
+ ret = -1;
+ }
+ } else {
+ fm->ingress = attr->ingress;
+ fm->egress = attr->egress;
+ fm->transfer = attr->transfer;
+ fm->ref_cnt = 1;
+ /* This also creates the meter object. */
+ fm->meter_action = mlx5_flow_meter_action_create(priv,
+ fm);
+ if (!fm->meter_action) {
+ fm->ref_cnt = 0;
+ fm->ingress = 0;
+ fm->egress = 0;
+ fm->transfer = 0;
+ rte_flow_error_set(error, EINVAL,
+ RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
+ "Meter action create failed.");
+ ret = -1;
+ }
}
+ rte_spinlock_unlock(&fm->sl);
}
- return fm;
-error_detach:
- mlx5_flow_meter_detach(fm);
- rte_flow_error_set(error, EINVAL, RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
- fm->mfts->meter_action ? "Meter attr not match" :
- "Meter action create failed");
-error:
- return NULL;
+ return ret ? -rte_errno : 0;
}
/**
* Detach meter from flow.
*
+ * @param [in] priv
+ * Pointer to mlx5 private data.
* @param [in] fm
* Pointer to flow meter.
*/
void
-mlx5_flow_meter_detach(struct mlx5_flow_meter *fm)
+mlx5_flow_meter_detach(struct mlx5_priv *priv,
+ struct mlx5_flow_meter_info *fm)
{
#ifdef HAVE_MLX5_DR_CREATE_ACTION_FLOW_METER
+ rte_spinlock_lock(&fm->sl);
MLX5_ASSERT(fm->ref_cnt);
- if (--fm->ref_cnt)
- return;
- if (fm->mfts->meter_action)
- mlx5_glue->destroy_flow_action(fm->mfts->meter_action);
- fm->mfts->meter_action = NULL;
- fm->ingress = 0;
- fm->egress = 0;
- fm->transfer = 0;
+ if (--fm->ref_cnt == 0 && !priv->sh->meter_aso_en) {
+ mlx5_glue->destroy_flow_action(fm->meter_action);
+ fm->meter_action = NULL;
+ fm->ingress = 0;
+ fm->egress = 0;
+ fm->transfer = 0;
+ }
+ rte_spinlock_unlock(&fm->sl);
#else
+ (void)priv;
(void)fm;
#endif
}
+/**
+ * Flush meter with Rx queue configuration.
+ *
+ * @param[in] dev
+ * Pointer to Ethernet device.
+ */
+void
+mlx5_flow_meter_rxq_flush(struct rte_eth_dev *dev)
+{
+ struct mlx5_priv *priv = dev->data->dev_private;
+ struct mlx5_flow_meter_sub_policy *sub_policy;
+ struct mlx5_flow_meter_policy *mtr_policy;
+ void *entry;
+ uint32_t i, policy_idx;
+
+ if (!priv->mtr_en)
+ return;
+ if (priv->sh->mtrmng->policy_idx_tbl && priv->sh->refcnt == 1) {
+ MLX5_L3T_FOREACH(priv->sh->mtrmng->policy_idx_tbl,
+ i, entry) {
+ policy_idx = *(uint32_t *)entry;
+ sub_policy = mlx5_ipool_get
+ (priv->sh->ipool[MLX5_IPOOL_MTR_POLICY],
+ policy_idx);
+ if (!sub_policy || !sub_policy->main_policy)
+ continue;
+ mtr_policy = sub_policy->main_policy;
+ if (mtr_policy->is_queue || mtr_policy->is_rss)
+ mlx5_flow_destroy_sub_policy_with_rxq(dev,
+ mtr_policy);
+ }
+ }
+}
+
/**
* Flush meter configuration.
*
mlx5_flow_meter_flush(struct rte_eth_dev *dev, struct rte_mtr_error *error)
{
struct mlx5_priv *priv = dev->data->dev_private;
- struct mlx5_flow_meters *fms = &priv->flow_meters;
+ struct mlx5_legacy_flow_meters *fms = &priv->flow_meters;
struct mlx5_mtr_profiles *fmps = &priv->flow_meter_profiles;
struct mlx5_flow_meter_profile *fmp;
- struct mlx5_flow_meter *fm;
- const struct rte_flow_attr attr = {
- .ingress = 1,
- .egress = 1,
- .transfer = priv->config.dv_esw_en ? 1 : 0,
- };
+ struct mlx5_legacy_flow_meter *legacy_fm;
+ struct mlx5_flow_meter_info *fm;
+ struct mlx5_flow_meter_sub_policy *sub_policy;
void *tmp;
- uint32_t i;
+ uint32_t i, mtr_idx, policy_idx;
+ void *entry;
+ struct mlx5_aso_mtr *aso_mtr;
- TAILQ_FOREACH_SAFE(fm, fms, next, tmp) {
- /* Meter object must not have any owner. */
- MLX5_ASSERT(!fm->ref_cnt);
- /* Get meter profile. */
- fmp = fm->profile;
- if (fmp == NULL)
- return -rte_mtr_error_set(error, EINVAL,
+ if (!priv->mtr_en)
+ return 0;
+ if (priv->sh->meter_aso_en) {
+ if (priv->mtr_idx_tbl) {
+ MLX5_L3T_FOREACH(priv->mtr_idx_tbl, i, entry) {
+ mtr_idx = *(uint32_t *)entry;
+ if (mtr_idx) {
+ aso_mtr =
+ mlx5_aso_meter_by_idx(priv, mtr_idx);
+ fm = &aso_mtr->fm;
+ (void)mlx5_flow_meter_params_flush(dev,
+ fm, mtr_idx);
+ }
+ }
+ mlx5_l3t_destroy(priv->mtr_idx_tbl);
+ priv->mtr_idx_tbl = NULL;
+ }
+ } else {
+ TAILQ_FOREACH_SAFE(legacy_fm, fms, next, tmp) {
+ fm = &legacy_fm->fm;
+ if (mlx5_flow_meter_params_flush(dev, fm, 0))
+ return -rte_mtr_error_set(error, EINVAL,
RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
NULL, "MTR object meter profile invalid.");
- /* Update dependencies. */
- fmp->ref_cnt--;
- /* Remove from list. */
- TAILQ_REMOVE(fms, fm, next);
- /* Free policer counters. */
- for (i = 0; i < RTE_DIM(fm->policer_stats.cnt); i++)
- if (fm->policer_stats.cnt[i])
- mlx5_counter_free(dev,
- fm->policer_stats.cnt[i]);
- /* Free meter flow table. */
- mlx5_flow_destroy_policer_rules(dev, fm, &attr);
- mlx5_flow_destroy_mtr_tbls(dev, fm->mfts);
- mlx5_ipool_free(priv->sh->ipool[MLX5_IPOOL_MTR], fm->idx);
+ }
+ }
+ if (priv->sh->mtrmng->policy_idx_tbl && priv->sh->refcnt == 1) {
+ MLX5_L3T_FOREACH(priv->sh->mtrmng->policy_idx_tbl,
+ i, entry) {
+ policy_idx = *(uint32_t *)entry;
+ sub_policy = mlx5_ipool_get
+ (priv->sh->ipool[MLX5_IPOOL_MTR_POLICY],
+ policy_idx);
+ if (!sub_policy)
+ return -rte_mtr_error_set(error,
+ EINVAL,
+ RTE_MTR_ERROR_TYPE_METER_POLICY_ID,
+ NULL, "MTR object "
+ "meter policy invalid.");
+ if (__mlx5_flow_meter_policy_delete(dev, i,
+ sub_policy->main_policy,
+ error))
+ return -rte_mtr_error_set(error,
+ EINVAL,
+ RTE_MTR_ERROR_TYPE_METER_POLICY_ID,
+ NULL, "MTR object "
+ "meter policy invalid.");
+ mlx5_free(sub_policy->main_policy);
+ }
+ mlx5_l3t_destroy(priv->sh->mtrmng->policy_idx_tbl);
+ priv->sh->mtrmng->policy_idx_tbl = NULL;
}
TAILQ_FOREACH_SAFE(fmp, fmps, next, tmp) {
/* Check unused. */
TAILQ_REMOVE(&priv->flow_meter_profiles, fmp, next);
mlx5_free(fmp);
}
+ /* Delete default policy table. */
+ mlx5_flow_destroy_def_policy(dev);
+ if (priv->sh->refcnt == 1)
+ mlx5_flow_destroy_mtr_drop_tbls(dev);
return 0;
}