net/mlx5: create rearm queue for packet pacing
[dpdk.git] / drivers / net / mlx5 / mlx5_flow_meter.c
index c4d28b2..86c334b 100644 (file)
@@ -9,6 +9,8 @@
 #include <rte_mtr.h>
 #include <rte_mtr_driver.h>
 
+#include <mlx5_devx_cmds.h>
+
 #include "mlx5.h"
 #include "mlx5_flow.h"
 
@@ -53,8 +55,8 @@ mlx5_flow_meter_action_create(struct mlx5_priv *priv,
        MLX5_SET(flow_meter_parameters,
                 attr, ebs_mantissa, srtcm->ebs_mantissa);
        mtr_init.next_table =
-               fm->attr.transfer ? fm->mfts->transfer.tbl->obj :
-                   fm->attr.egress ? fm->mfts->egress.tbl->obj :
+               fm->transfer ? fm->mfts->transfer.tbl->obj :
+                   fm->egress ? fm->mfts->egress.tbl->obj :
                                       fm->mfts->ingress.tbl->obj;
        mtr_init.reg_c_index = priv->mtr_color_reg - REG_C_0;
        mtr_init.flow_meter_parameter = fm->mfts->fmp;
@@ -301,7 +303,7 @@ mlx5_flow_mtr_cap_get(struct rte_eth_dev *dev,
        if (!priv->mtr_en)
                return -rte_mtr_error_set(error, ENOTSUP,
                                          RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
-                                         "Meter is not support");
+                                         "Meter is not supported");
        memset(cap, 0, sizeof(*cap));
        cap->n_max = 1 << qattr->log_max_flow_meter;
        cap->n_shared_max = cap->n_max;
@@ -347,7 +349,7 @@ mlx5_flow_meter_profile_add(struct rte_eth_dev *dev,
        if (!priv->mtr_en)
                return -rte_mtr_error_set(error, ENOTSUP,
                                          RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
-                                         "Meter is not support");
+                                         "Meter is not supported");
        /* Check input params. */
        ret = mlx5_flow_meter_profile_validate(dev, meter_profile_id,
                                               profile, error);
@@ -400,19 +402,19 @@ mlx5_flow_meter_profile_delete(struct rte_eth_dev *dev,
        if (!priv->mtr_en)
                return -rte_mtr_error_set(error, ENOTSUP,
                                          RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
-                                         "Meter is not support");
+                                         "Meter is not supported");
        /* Meter profile must exist. */
        fmp = mlx5_flow_meter_profile_find(priv, meter_profile_id);
        if (fmp == NULL)
                return -rte_mtr_error_set(error, ENOENT,
                                          RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
                                          &meter_profile_id,
-                                         "Meter profile id invalid.");
+                                         "Meter profile id is invalid.");
        /* Check profile is unused. */
        if (fmp->ref_cnt)
                return -rte_mtr_error_set(error, EBUSY,
                                          RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
-                                         NULL, "Meter profile in use.");
+                                         NULL, "Meter profile is in use.");
        /* Remove from list. */
        TAILQ_REMOVE(&priv->flow_meter_profiles, fmp, next);
        rte_free(fmp);
@@ -629,11 +631,12 @@ mlx5_flow_meter_create(struct rte_eth_dev *dev, uint32_t meter_id,
                        };
        int ret;
        unsigned int i;
+       uint32_t idx = 0;
 
        if (!priv->mtr_en)
                return -rte_mtr_error_set(error, ENOTSUP,
                                          RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
-                                         "Meter is not support");
+                                         "Meter is not supported");
        /* Validate the parameters. */
        ret = mlx5_flow_meter_validate(priv, meter_id, params, error);
        if (ret)
@@ -645,16 +648,18 @@ mlx5_flow_meter_create(struct rte_eth_dev *dev, uint32_t meter_id,
                                          RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
                                          NULL, "Meter profile id not valid.");
        /* Allocate the flow meter memory. */
-       fm = rte_calloc(__func__, 1,
-                       sizeof(struct mlx5_flow_meter), RTE_CACHE_LINE_SIZE);
+       fm = mlx5_ipool_zmalloc(priv->sh->ipool[MLX5_IPOOL_MTR], &idx);
        if (fm == NULL)
                return -rte_mtr_error_set(error, ENOMEM,
                                          RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
                                          "Memory alloc failed for meter.");
+       fm->idx = idx;
        /* Fill the flow meter parameters. */
        fm->meter_id = meter_id;
        fm->profile = fmp;
-       fm->params = *params;
+       memcpy(fm->action, params->action, sizeof(params->action));
+       fm->stats_mask = params->stats_mask;
+
        /* Alloc policer counters. */
        for (i = 0; i < RTE_DIM(fm->policer_stats.cnt); i++) {
                fm->policer_stats.cnt[i] = mlx5_counter_alloc(dev);
@@ -681,7 +686,7 @@ error:
        for (i = 0; i < RTE_DIM(fm->policer_stats.cnt); i++)
                if (fm->policer_stats.cnt[i])
                        mlx5_counter_free(dev, fm->policer_stats.cnt[i]);
-       rte_free(fm);
+       mlx5_ipool_free(priv->sh->ipool[MLX5_IPOOL_MTR], idx);
        return -rte_mtr_error_set(error, -ret,
                                  RTE_MTR_ERROR_TYPE_UNSPECIFIED,
                                  NULL, "Failed to create devx meter.");
@@ -718,7 +723,7 @@ mlx5_flow_meter_destroy(struct rte_eth_dev *dev, uint32_t meter_id,
        if (!priv->mtr_en)
                return -rte_mtr_error_set(error, ENOTSUP,
                                          RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
-                                         "Meter is not support");
+                                         "Meter is not supported");
        /* Meter object must exist. */
        fm = mlx5_flow_meter_find(priv, meter_id);
        if (fm == NULL)
@@ -732,7 +737,7 @@ mlx5_flow_meter_destroy(struct rte_eth_dev *dev, uint32_t meter_id,
                                          NULL, "Meter object is being used.");
        /* Get the meter profile. */
        fmp = fm->profile;
-       RTE_ASSERT(fmp);
+       MLX5_ASSERT(fmp);
        /* Update dependencies. */
        fmp->ref_cnt--;
        /* Remove from the flow meter list. */
@@ -744,7 +749,7 @@ mlx5_flow_meter_destroy(struct rte_eth_dev *dev, uint32_t meter_id,
        /* Free meter flow table */
        mlx5_flow_destroy_policer_rules(dev, fm, &attr);
        mlx5_flow_destroy_mtr_tbls(dev, fm->mfts);
-       rte_free(fm);
+       mlx5_ipool_free(priv->sh->ipool[MLX5_IPOOL_MTR], fm->idx);
        return 0;
 }
 
@@ -823,7 +828,7 @@ mlx5_flow_meter_enable(struct rte_eth_dev *dev,
        if (!priv->mtr_en)
                return -rte_mtr_error_set(error, ENOTSUP,
                                          RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
-                                         "Meter is not support");
+                                         "Meter is not supported");
        /* Meter object must exist. */
        fm = mlx5_flow_meter_find(priv, meter_id);
        if (fm == NULL)
@@ -864,7 +869,7 @@ mlx5_flow_meter_disable(struct rte_eth_dev *dev,
        if (!priv->mtr_en)
                return -rte_mtr_error_set(error, ENOTSUP,
                                          RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
-                                         "Meter is not support");
+                                         "Meter is not supported");
        /* Meter object must exist. */
        fm = mlx5_flow_meter_find(priv, meter_id);
        if (fm == NULL)
@@ -912,7 +917,7 @@ mlx5_flow_meter_profile_update(struct rte_eth_dev *dev,
        if (!priv->mtr_en)
                return -rte_mtr_error_set(error, ENOTSUP,
                                          RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
-                                         "Meter is not support");
+                                         "Meter is not supported");
        /* Meter profile must exist. */
        fmp = mlx5_flow_meter_profile_find(priv, meter_profile_id);
        if (fmp == NULL)
@@ -975,7 +980,7 @@ mlx5_flow_meter_stats_update(struct rte_eth_dev *dev,
        if (!priv->mtr_en)
                return -rte_mtr_error_set(error, ENOTSUP,
                                          RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
-                                         "Meter is not support");
+                                         "Meter is not supported");
        /* Meter object must exist. */
        fm = mlx5_flow_meter_find(priv, meter_id);
        if (fm == NULL)
@@ -1032,7 +1037,7 @@ mlx5_flow_meter_stats_read(struct rte_eth_dev *dev,
        if (!priv->mtr_en)
                return -rte_mtr_error_set(error, ENOTSUP,
                                          RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
-                                         "Meter is not support");
+                                         "Meter is not supported");
        /* Meter object must exist. */
        fm = mlx5_flow_meter_find(priv, meter_id);
        if (fm == NULL)
@@ -1047,7 +1052,7 @@ mlx5_flow_meter_stats_read(struct rte_eth_dev *dev,
                                                 &bytes);
                        if (ret)
                                goto error;
-                       if (fm->params.action[i] == MTR_POLICER_ACTION_DROP) {
+                       if (fm->action[i] == MTR_POLICER_ACTION_DROP) {
                                pkts_dropped += pkts;
                                bytes_dropped += bytes;
                        }
@@ -1177,18 +1182,20 @@ mlx5_flow_meter_attach(struct mlx5_priv *priv, uint32_t meter_id,
                goto error;
        }
        if (!fm->ref_cnt++) {
-               RTE_ASSERT(!fm->mfts->meter_action);
-               fm->attr = *attr;
+               MLX5_ASSERT(!fm->mfts->meter_action);
+               fm->ingress = attr->ingress;
+               fm->egress = attr->egress;
+               fm->transfer = attr->transfer;
                /* This also creates the meter object. */
                fm->mfts->meter_action = mlx5_flow_meter_action_create(priv,
                                                                       fm);
                if (!fm->mfts->meter_action)
                        goto error_detach;
        } else {
-               RTE_ASSERT(fm->mfts->meter_action);
-               if (attr->transfer != fm->attr.transfer ||
-                   attr->ingress != fm->attr.ingress ||
-                   attr->egress != fm->attr.egress) {
+               MLX5_ASSERT(fm->mfts->meter_action);
+               if (attr->transfer != fm->transfer ||
+                   attr->ingress != fm->ingress ||
+                   attr->egress != fm->egress) {
                        DRV_LOG(ERR, "meter I/O attributes do not "
                                "match flow I/O attributes.");
                        goto error_detach;
@@ -1213,15 +1220,15 @@ error:
 void
 mlx5_flow_meter_detach(struct mlx5_flow_meter *fm)
 {
-       const struct rte_flow_attr attr = { 0 };
-
-       RTE_ASSERT(fm->ref_cnt);
+       MLX5_ASSERT(fm->ref_cnt);
        if (--fm->ref_cnt)
                return;
        if (fm->mfts->meter_action)
                mlx5_glue->destroy_flow_action(fm->mfts->meter_action);
        fm->mfts->meter_action = NULL;
-       fm->attr = attr;
+       fm->ingress = 0;
+       fm->egress = 0;
+       fm->transfer = 0;
 }
 
 /**
@@ -1253,7 +1260,7 @@ mlx5_flow_meter_flush(struct rte_eth_dev *dev, struct rte_mtr_error *error)
 
        TAILQ_FOREACH_SAFE(fm, fms, next, tmp) {
                /* Meter object must not have any owner. */
-               RTE_ASSERT(!fm->ref_cnt);
+               MLX5_ASSERT(!fm->ref_cnt);
                /* Get meter profile. */
                fmp = fm->profile;
                if (fmp == NULL)
@@ -1272,11 +1279,11 @@ mlx5_flow_meter_flush(struct rte_eth_dev *dev, struct rte_mtr_error *error)
                /* Free meter flow table. */
                mlx5_flow_destroy_policer_rules(dev, fm, &attr);
                mlx5_flow_destroy_mtr_tbls(dev, fm->mfts);
-               rte_free(fm);
+               mlx5_ipool_free(priv->sh->ipool[MLX5_IPOOL_MTR], fm->idx);
        }
        TAILQ_FOREACH_SAFE(fmp, fmps, next, tmp) {
                /* Check unused. */
-               RTE_ASSERT(!fmp->ref_cnt);
+               MLX5_ASSERT(!fmp->ref_cnt);
                /* Remove from list. */
                TAILQ_REMOVE(&priv->flow_meter_profiles, fmp, next);
                rte_free(fmp);