net/hns3: support flow control autoneg for copper port
If the flow control auto-negotiation is not supported and the flow
control modes on the local and link partner is asymmetric, the flow
control on the NIC does not take effect. The support of the
auto-negotiation capability requires the cooperation of the firmware
and driver.
This patch supports the flow control auto-negotiation only for copper
port. For optical ports, the forced flow control mode is still used.
Signed-off-by: Huisong Li <lihuisong@huawei.com>