net/mlx5: fix flow mark with sampling and metering
If there are sample action and the meter action in the same flow,
mlx5 PMD performs several levels of splitting. For example, sampling
feature splits the original flow into prefix subflow with sample action,
and suffix subflow with the rest of actions. Then, metering feature
splits the sampling suffix subflow into its own meter subflows.
If mark action was added before the sample and meter action, the
flow mark flag was kept in the sample subflows but reset on
handling the metering split, causing the flow mark value missed.
This patch keeps the flow mark flag of previous subflow, and then
the following meter subflows handle the flow mark correctly.
Fixes: 9ade91dfe85d ("net/mlx5: fix group value of sample suffix flow")
Cc: stable@dpdk.org
Signed-off-by: Jiawei Wang <jiaweiw@nvidia.com>
Acked-by: Viacheslav Ovsiienko <viacheslavo@nvidia.com>