examples/flow_classify: fix NUMA check of port and core
authorMin Hu (Connor) <humin29@huawei.com>
Thu, 29 Apr 2021 00:50:46 +0000 (08:50 +0800)
committerThomas Monjalon <thomas@monjalon.net>
Wed, 12 May 2021 19:46:05 +0000 (21:46 +0200)
commit78a5545ef92b48553be4a244514a2514ca9b09b0
tree5fadb3bfce03bad29bfc80ce637dcc8395ae3610
parent7861009f7b2ca7a028ee7fe867c90cd5560de529
examples/flow_classify: fix NUMA check of port and core

According to the comments and logging, the author just hope user to use
the core and device which are in the same numa node for optimal
performance. If not, A warning gives out.

For example in flow_classify:
./build/flow_classify -a 0000:7d:00.1  -l 93
Here:
0000:7d:00.1 is on numa node 0.
core 93  is on numa node 3.

The two are not in same numa node, but no warning gives out in old codes
when device is on node 0.
This patch includes the node 0 in the check.

Fixes: bab16ddaf2c1 ("examples/flow_classify: add sample application")
Cc: stable@dpdk.org
Signed-off-by: Min Hu (Connor) <humin29@huawei.com>
Tested-by: Bernard Iremonger <bernard.iremonger@intel.com>
Acked-by: Bernard Iremonger <bernard.iremonger@intel.com>
Reviewed-by: Ferruh Yigit <ferruh.yigit@intel.com>
examples/flow_classify/flow_classify.c