net/mlx5: add meter attach and detach
authorSuanming Mou <suanmingm@mellanox.com>
Fri, 8 Nov 2019 03:49:21 +0000 (05:49 +0200)
committerFerruh Yigit <ferruh.yigit@intel.com>
Mon, 11 Nov 2019 13:23:02 +0000 (14:23 +0100)
Add the meter attach and detach for the flow create.

When create the flow with meter, first try to find any created meter
action matches the flow meter id. If the meter action is already
created, just attach to it and increase the ref_cnt. If not, create
one.

For the dettach, decrease the ref_cnt, destroy the meter action while
the ref_cnt decreased to zero.

Signed-off-by: Suanming Mou <suanmingm@mellanox.com>
Acked-by: Matan Azrad <matan@mellanox.com>
drivers/net/mlx5/mlx5.h
drivers/net/mlx5/mlx5_flow.h
drivers/net/mlx5/mlx5_flow_meter.c

index f9e1396..e8148ce 100644 (file)
@@ -1040,5 +1040,11 @@ struct mlx5_devx_obj *mlx5_devx_cmd_create_td(struct ibv_context *ctx);
 int mlx5_flow_meter_ops_get(struct rte_eth_dev *dev, void *arg);
 struct mlx5_flow_meter *mlx5_flow_meter_find(struct mlx5_priv *priv,
                                             uint32_t meter_id);
+struct mlx5_flow_meter *mlx5_flow_meter_attach
+                                       (struct mlx5_priv *priv,
+                                        uint32_t meter_id,
+                                        const struct rte_flow_attr *attr,
+                                        struct rte_flow_error *error);
+void mlx5_flow_meter_detach(struct mlx5_flow_meter *fm);
 
 #endif /* RTE_PMD_MLX5_H_ */
index cdcca7a..ffb6886 100644 (file)
@@ -201,6 +201,7 @@ enum mlx5_feature_name {
 #define MLX5_FLOW_ACTION_SET_TAG (1ull << 32)
 #define MLX5_FLOW_ACTION_MARK_EXT (1ull << 33)
 #define MLX5_FLOW_ACTION_SET_META (1ull << 34)
+#define MLX5_FLOW_ACTION_METER (1ull << 35)
 
 #define MLX5_FLOW_FATE_ACTIONS \
        (MLX5_FLOW_ACTION_DROP | MLX5_FLOW_ACTION_QUEUE | \
@@ -585,6 +586,8 @@ struct mlx5_flow_meter {
        /**< Meter rule parameters. */
        struct mlx5_flow_meter_profile *profile;
        /**< Meter profile parameters. */
+       struct rte_flow_attr attr;
+       /**< Flow attributes. */
        struct mlx5_meter_domains_infos *mfts;
        /**< Flow table created for this meter. */
        struct mlx5_flow_policer_stats policer_stats;
@@ -631,6 +634,7 @@ struct rte_flow {
        struct mlx5_flow_counter *counter; /**< Holds flow counter. */
        struct mlx5_flow_mreg_copy_resource *mreg_copy;
        /**< pointer to metadata register copy table resource. */
+       struct mlx5_flow_meter *meter; /**< Holds flow meter. */
        LIST_HEAD(dev_flows, mlx5_flow) dev_flows;
        /**< Device flows that are part of the flow. */
        struct mlx5_fdir *fdir; /**< Pointer to associated FDIR if any. */
index c39e703..7b9d394 100644 (file)
 #include "mlx5.h"
 #include "mlx5_flow.h"
 
+/**
+ * Create the meter action.
+ *
+ * @param priv
+ *   Pointer to mlx5_priv.
+ * @param[in] fm
+ *   Pointer to flow meter to be converted.
+ *
+ * @return
+ *   Pointer to the meter action on success, NULL otherwise.
+ */
+static void *
+mlx5_flow_meter_action_create(struct mlx5_priv *priv,
+                             struct mlx5_flow_meter *fm)
+{
+#ifdef HAVE_MLX5_DR_CREATE_ACTION_FLOW_METER
+       struct mlx5dv_dr_flow_meter_attr mtr_init;
+       void *attr = fm->mfts->fmp;
+       struct mlx5_flow_meter_srtcm_rfc2697_prm *srtcm =
+                                                    &fm->profile->srtcm_prm;
+
+       fm->mfts->fmp_size = MLX5_ST_SZ_BYTES(flow_meter_parameters);
+       memset(attr, 0, fm->mfts->fmp_size);
+       MLX5_SET(flow_meter_parameters, attr, valid, 1);
+       MLX5_SET(flow_meter_parameters, attr, bucket_overflow, 1);
+       MLX5_SET(flow_meter_parameters, attr,
+                start_color, MLX5_FLOW_COLOR_GREEN);
+       MLX5_SET(flow_meter_parameters, attr, both_buckets_on_green, 0);
+       MLX5_SET(flow_meter_parameters,
+                attr, cbs_exponent, srtcm->cbs_exponent);
+       MLX5_SET(flow_meter_parameters,
+                attr, cbs_mantissa, srtcm->cbs_mantissa);
+       MLX5_SET(flow_meter_parameters,
+                attr, cir_exponent, srtcm->cir_exponent);
+       MLX5_SET(flow_meter_parameters,
+                attr, cir_mantissa, srtcm->cir_mantissa);
+       MLX5_SET(flow_meter_parameters,
+                attr, ebs_exponent, srtcm->ebs_exponent);
+       MLX5_SET(flow_meter_parameters,
+                attr, ebs_mantissa, srtcm->ebs_mantissa);
+       mtr_init.next_table =
+               fm->attr.transfer ? fm->mfts->transfer.tbl->obj :
+                   fm->attr.egress ? fm->mfts->egress.tbl->obj :
+                                      fm->mfts->ingress.tbl->obj;
+       mtr_init.reg_c_index = priv->mtr_color_reg - REG_C_0;
+       mtr_init.flow_meter_parameter = fm->mfts->fmp;
+       mtr_init.flow_meter_parameter_sz = fm->mfts->fmp_size;
+       mtr_init.active = fm->active_state;
+       return mlx5_glue->dv_create_flow_action_meter(&mtr_init);
+#else
+       (void)priv;
+       (void)fm;
+       return NULL;
+#endif
+}
+
 /**
  * Find meter profile by id.
  *
@@ -1081,3 +1137,88 @@ mlx5_flow_meter_find(struct mlx5_priv *priv, uint32_t meter_id)
                        return fm;
        return NULL;
 }
+
+/**
+ * Attach meter to flow.
+ * Unidirectional Meter creation can only be done
+ * when flow direction is known, i.e. when calling meter_attach.
+ *
+ * @param [in] priv
+ *  Pointer to mlx5 private data.
+ * @param [in] meter_id
+ *  Flow meter id.
+ * @param [in] attr
+ *  Pointer to flow attributes.
+ * @param [out] error
+ *  Pointer to error structure.
+ *
+ * @return the flow meter pointer, NULL otherwise.
+ */
+struct mlx5_flow_meter *
+mlx5_flow_meter_attach(struct mlx5_priv *priv, uint32_t meter_id,
+                      const struct rte_flow_attr *attr,
+                      struct rte_flow_error *error)
+{
+       struct mlx5_flow_meter *fm;
+
+       fm = mlx5_flow_meter_find(priv, meter_id);
+       if (fm == NULL) {
+               rte_flow_error_set(error, ENOENT,
+                                  RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
+                                  "Meter object id not valid");
+               goto error;
+       }
+       if (!fm->shared && fm->ref_cnt) {
+               DRV_LOG(ERR, "Cannot share a non-shared meter.");
+               rte_flow_error_set(error, EINVAL,
+                                 RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
+                                 "Meter can't be shared");
+               goto error;
+       }
+       if (!fm->ref_cnt++) {
+               RTE_ASSERT(!fm->mfts->meter_action);
+               fm->attr = *attr;
+               /* This also creates the meter object. */
+               fm->mfts->meter_action = mlx5_flow_meter_action_create(priv,
+                                                                      fm);
+               if (!fm->mfts->meter_action)
+                       goto error_detach;
+       } else {
+               RTE_ASSERT(fm->mfts->meter_action);
+               if (attr->transfer != fm->attr.transfer ||
+                   attr->ingress != fm->attr.ingress ||
+                   attr->egress != fm->attr.egress) {
+                       DRV_LOG(ERR, "meter I/O attributes do not "
+                               "match flow I/O attributes.");
+                       goto error_detach;
+               }
+       }
+       return fm;
+error_detach:
+       mlx5_flow_meter_detach(fm);
+       rte_flow_error_set(error, EINVAL, RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
+                         fm->mfts->meter_action ? "Meter attr not match" :
+                         "Meter action create failed");
+error:
+       return NULL;
+}
+
+/**
+ * Detach meter from flow.
+ *
+ * @param [in] fm
+ *  Pointer to flow meter.
+ */
+void
+mlx5_flow_meter_detach(struct mlx5_flow_meter *fm)
+{
+       const struct rte_flow_attr attr = { 0 };
+
+       RTE_ASSERT(fm->ref_cnt);
+       if (--fm->ref_cnt)
+               return;
+       if (fm->mfts->meter_action)
+               mlx5_glue->destroy_flow_action(fm->mfts->meter_action);
+       fm->mfts->meter_action = NULL;
+       fm->attr = attr;
+}