net/mlx5: fix VLAN VID action validation
authorDekel Peled <dekelp@mellanox.com>
Wed, 22 Jan 2020 14:27:21 +0000 (16:27 +0200)
committerFerruh Yigit <ferruh.yigit@intel.com>
Wed, 5 Feb 2020 08:51:20 +0000 (09:51 +0100)
Validation function of 'set VLAN VID' action checks twice for existing
same action in flow rule.

This patch updates the validation function logic, to check the same
restrictions more efficiently.

Fixes: 5f163d520cff ("net/mlx5: support modify VLAN ID on existing VLAN header")
Fixes: b8c0372bc5ac ("net/mlx5: fix set VLAN ID/PCP in new header")
Cc: stable@dpdk.org
Signed-off-by: Dekel Peled <dekelp@mellanox.com>
Acked-by: Ori Kam <orika@mellanox.com>
Acked-by: Viacheslav Ovsiienko <viacheslavo@mellanox.com>
drivers/net/mlx5/mlx5_flow_dv.c

index de4b765..4b6a92c 100644 (file)
@@ -1815,10 +1815,10 @@ flow_dv_validate_action_set_vlan_pcp(uint64_t action_flags,
  *
  * @param[in] item_flags
  *   Holds the items detected in this rule.
+ * @param[in] action_flags
+ *   Holds the actions detected until now.
  * @param[in] actions
  *   Pointer to the list of actions remaining in the flow rule.
- * @param[in] attr
- *   Pointer to flow attributes
  * @param[out] error
  *   Pointer to error structure.
  *
@@ -1838,33 +1838,17 @@ flow_dv_validate_action_set_vlan_vid(uint64_t item_flags,
                return rte_flow_error_set(error, EINVAL,
                                          RTE_FLOW_ERROR_TYPE_ACTION, action,
                                          "VLAN VID value is too big");
-       /* there is an of_push_vlan action before us */
-       if (action_flags & MLX5_FLOW_ACTION_OF_PUSH_VLAN) {
-               if (mlx5_flow_find_action(actions + 1,
-                                         RTE_FLOW_ACTION_TYPE_OF_SET_VLAN_VID))
-                       return rte_flow_error_set(error, ENOTSUP,
-                                       RTE_FLOW_ERROR_TYPE_ACTION, action,
-                                       "Multiple VLAN VID modifications are "
-                                       "not supported");
-               else
-                       return 0;
-       }
-
-       /*
-        * Action is on an existing VLAN header:
-        *    Need to verify this is a single modify CID action.
-        *   Rule mast include a match on outer VLAN.
-        */
+       if (!(action_flags & MLX5_FLOW_ACTION_OF_PUSH_VLAN) &&
+           !(item_flags & MLX5_FLOW_LAYER_OUTER_VLAN))
+               return rte_flow_error_set(error, ENOTSUP,
+                                         RTE_FLOW_ERROR_TYPE_ACTION, action,
+                                         "set VLAN VID action must follow push"
+                                         " VLAN action or match on VLAN item");
        if (action_flags & MLX5_FLOW_ACTION_OF_SET_VLAN_VID)
                return rte_flow_error_set(error, ENOTSUP,
                                          RTE_FLOW_ERROR_TYPE_ACTION, action,
                                          "Multiple VLAN VID modifications are "
                                          "not supported");
-       if (!(item_flags & MLX5_FLOW_LAYER_OUTER_VLAN))
-               return rte_flow_error_set(error, EINVAL,
-                                         RTE_FLOW_ERROR_TYPE_ACTION, action,
-                                         "match on VLAN is required in order "
-                                         "to set VLAN VID");
        if (action_flags & MLX5_FLOW_ACTION_PORT_ID)
                return rte_flow_error_set(error, EINVAL,
                                          RTE_FLOW_ERROR_TYPE_ACTION, action,