When VF adds VLAN, Linux PF driver enables VLAN stripping by default,
this might have issues if the app configured DEV_RX_OFFLOAD_VLAN_STRIP.
This behavior of the Linux driver causes confusion with the DPDK app
using i40e_pmd. So it is better to reconfigure the vlan_offload, which
checks for DEV_RX_OFFLOAD_VLAN_STRIP flag in the dev_conf and enables or
disables the vlan strip in the PF.
Application cannot use rte_eth_dev_set_vlan_offload() to set
the VLAN_STRIP, as this will only work for the first time when
original and current config mismatch, but for all subsequent call
it will be ignored.
Fixes:
4861cde46116 ("i40e: new poll mode driver")
Cc: stable@dpdk.org
Signed-off-by: Souvik Dey <sodey@rbbn.com>
Acked-by: Jeff Guo <jia.guo@intel.com>
args.out_buffer = vf->aq_resp;
args.out_size = I40E_AQ_BUF_SZ;
err = i40evf_execute_vf_cmd(dev, &args);
- if (err)
+ if (err) {
PMD_DRV_LOG(ERR, "fail to execute command OP_ADD_VLAN");
+ return err;
+ }
+ /**
+ * In linux kernel driver on receiving ADD_VLAN it enables
+ * VLAN_STRIP by default. So reconfigure the vlan_offload
+ * as it was done by the app earlier.
+ */
+ err = i40evf_vlan_offload_set(dev, ETH_VLAN_STRIP_MASK);
+ if (err)
+ PMD_DRV_LOG(ERR, "fail to set vlan_strip");
return err;
}