Current implementation only outputs 3 numbers for busyness, 0, 50 and 100.
Fix this so that the 50% is replaced by a curve, more meaningful.
This can be replaced in each use case by a suitable calculation for
that use case.
Fixes:
609e79841fcf ("examples/l3fwd-power: add telemetry mode")
Signed-off-by: David Hunt <david.hunt@intel.com>
Acked-by: Anatoly Burakov <anatoly.burakov@intel.com>
* reference CYCLES to be used to
* measure core busyness based on poll count
*/
-#define MIN_CYCLES 1500000ULL
-#define MAX_CYCLES 2500000ULL
+#define MIN_CYCLES 1500000ULL
+#define MAX_CYCLES 22000000ULL
/* (500ms) */
#define TELEMETRY_INTERVALS_PER_SEC 2
br = FULL;
} else if (diff_tsc > MIN_CYCLES &&
diff_tsc < MAX_CYCLES) {
- br = PARTIAL;
+ br = (diff_tsc * 100) / MAX_CYCLES;
} else {
br = ZERO;
}