RFC 4115 allows a meter with either cir and/or eir configured.
When only one is configured a divide by zero would occur.
Fixes:
655796d2b5fb ("meter: support RFC4115 trTCM")
Signed-off-by: Eelco Chaudron <echaudro@redhat.com>
static void
rte_meter_get_tb_params(uint64_t hz, uint64_t rate, uint64_t *tb_period, uint64_t *tb_bytes_per_period)
{
- double period = ((double) hz) / ((double) rate);
+ double period;
+
+ if (rate == 0) {
+ *tb_bytes_per_period = 0;
+ *tb_period = RTE_METER_TB_PERIOD_MIN;
+ return;
+ }
+
+ period = ((double) hz) / ((double) rate);
if (period >= RTE_METER_TB_PERIOD_MIN) {
*tb_bytes_per_period = 1;