unify tools naming
[dpdk.git] / doc / guides / linux_gsg / nic_perf_intel_platform.rst
1 How to get best performance with NICs on Intel platforms
2 ========================================================
3
4 This document is a step-by-step guide for getting high performance from DPDK applications on Intel platforms.
5
6
7 Hardware and Memory Requirements
8 --------------------------------
9
10 For best performance use an Intel Xeon class server system such as Ivy Bridge, Haswell or newer.
11
12 Ensure that each memory channel has at least one memory DIMM inserted, and that the memory size for each is at least 4GB.
13 **Note**: this has one of the most direct effects on performance.
14
15 You can check the memory configuration using ``dmidecode`` as follows::
16
17       dmidecode -t memory | grep Locator
18
19       Locator: DIMM_A1
20       Bank Locator: NODE 1
21       Locator: DIMM_A2
22       Bank Locator: NODE 1
23       Locator: DIMM_B1
24       Bank Locator: NODE 1
25       Locator: DIMM_B2
26       Bank Locator: NODE 1
27       ...
28       Locator: DIMM_G1
29       Bank Locator: NODE 2
30       Locator: DIMM_G2
31       Bank Locator: NODE 2
32       Locator: DIMM_H1
33       Bank Locator: NODE 2
34       Locator: DIMM_H2
35       Bank Locator: NODE 2
36
37 The sample output above shows a total of 8 channels, from ``A`` to ``H``, where each channel has 2 DIMMs.
38
39 You can also use ``dmidecode`` to determine the memory frequency::
40
41       dmidecode -t memory | grep Speed
42
43       Speed: 2133 MHz
44       Configured Clock Speed: 2134 MHz
45       Speed: Unknown
46       Configured Clock Speed: Unknown
47       Speed: 2133 MHz
48       Configured Clock Speed: 2134 MHz
49       Speed: Unknown
50       ...
51       Speed: 2133 MHz
52       Configured Clock Speed: 2134 MHz
53       Speed: Unknown
54       Configured Clock Speed: Unknown
55       Speed: 2133 MHz
56       Configured Clock Speed: 2134 MHz
57       Speed: Unknown
58       Configured Clock Speed: Unknown
59
60 The output shows a speed of 2133 MHz (DDR4) and Unknown (not existing).
61 This aligns with the previous output which showed that each channel has one memory bar.
62
63
64 Network Interface Card Requirements
65 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
66
67 Use a `DPDK supported <http://dpdk.org/doc/nics>`_ high end NIC such as the Intel XL710 40GbE.
68
69 Make sure each NIC has been flashed the latest version of NVM/firmware.
70
71 Use PCIe Gen3 slots, such as Gen3 ``x8`` or Gen3 ``x16`` because PCIe Gen2 slots don't provide enough bandwidth
72 for 2 x 10GbE and above.
73 You can use ``lspci`` to check the speed of a PCI slot using something like the following::
74
75       lspci -s 03:00.1 -vv | grep LnkSta
76
77       LnkSta: Speed 8GT/s, Width x8, TrErr- Train- SlotClk+ DLActive- ...
78       LnkSta2: Current De-emphasis Level: -6dB, EqualizationComplete+ ...
79
80 When inserting NICs into PCI slots always check the caption, such as CPU0 or CPU1 to indicate which socket it is connected to.
81
82 Care should be take with NUMA.
83 If you are using 2 or more ports from different NICs, it is best to ensure that these NICs are on the same CPU socket.
84 An example of how to determine this is shown further below.
85
86
87 BIOS Settings
88 ~~~~~~~~~~~~~
89
90 The following are some recommendations on BIOS settings. Different platforms will have different BIOS naming
91 so the following is mainly for reference:
92
93 #. Before starting consider resetting all BIOS settings to their default.
94
95 #. Disable all power saving options such as: Power performance tuning, CPU P-State, CPU C3 Report and CPU C6 Report.
96
97 #. Select **Performance** as the CPU Power and Performance policy.
98
99 #. Disable Turbo Boost to ensure the performance scaling increases with the number of cores.
100
101 #. Set memory frequency to the highest available number, NOT auto.
102
103 #. Disable all virtualization options when you test the physical function of the NIC, and turn on ``VT-d`` if you wants to use VFIO.
104
105
106 Linux boot command line
107 ~~~~~~~~~~~~~~~~~~~~~~~
108
109 The following are some recommendations on GRUB boot settings:
110
111 #. Use the default grub file as a starting point.
112
113 #. Reserve 1G huge pages via grub configurations. For example to reserve 8 huge pages of 1G size::
114
115       default_hugepagesz=1G hugepagesz=1G hugepages=8
116
117 #. Isolate CPU cores which will be used for DPDK. For example::
118
119       isolcpus=2,3,4,5,6,7,8
120
121 #. If it wants to use VFIO, use the following additional grub parameters::
122
123       iommu=pt intel_iommu=on
124
125
126 Configurations before running DPDK
127 ----------------------------------
128
129 1. Build the DPDK target and reserve huge pages.
130    See the earlier section on :ref:`linux_gsg_hugepages` for more details.
131
132    The following shell commands may help with building and configuration:
133
134    .. code-block:: console
135
136       # Build DPDK target.
137       cd dpdk_folder
138       make install T=x86_64-native-linuxapp-gcc -j
139
140       # Get the hugepage size.
141       awk '/Hugepagesize/ {print $2}' /proc/meminfo
142
143       # Get the total huge page numbers.
144       awk '/HugePages_Total/ {print $2} ' /proc/meminfo
145
146       # Unmount the hugepages.
147       umount `awk '/hugetlbfs/ {print $2}' /proc/mounts`
148
149       # Create the hugepage mount folder.
150       mkdir -p /mnt/huge
151
152       # Mount to the specific folder.
153       mount -t hugetlbfs nodev /mnt/huge
154
155 2. Check the CPU layout using using the DPDK ``cpu_layout`` utility:
156
157    .. code-block:: console
158
159       cd dpdk_folder
160
161       tools/cpu_layout.py
162
163    Or run ``lscpu`` to check the the cores on each socket.
164
165 3. Check your NIC id and related socket id:
166
167    .. code-block:: console
168
169       # List all the NICs with PCI address and device IDs.
170       lspci -nn | grep Eth
171
172    For example suppose your output was as follows::
173
174       82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
175       82:00.1 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
176       85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
177       85:00.1 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
178
179    Check the PCI device related numa node id:
180
181    .. code-block:: console
182
183       cat /sys/bus/pci/devices/0000\:xx\:00.x/numa_node
184
185    Usually ``0x:00.x`` is on socket 0 and ``8x:00.x`` is on socket 1.
186    **Note**: To get the best performance, ensure that the core and NICs are in the same socket.
187    In the example above ``85:00.0`` is on socket 1 and should be used by cores on socket 1 for the best performance.
188
189 4. Bind the test ports to DPDK compatible drivers, such as igb_uio. For example bind two ports to a DPDK compatible driver and check the status:
190
191    .. code-block:: console
192
193
194       # Bind ports 82:00.0 and 85:00.0 to dpdk driver
195       ./dpdk_folder/tools/dpdk-devbind.py -b igb_uio 82:00.0 85:00.0
196
197       # Check the port driver status
198       ./dpdk_folder/tools/dpdk-devbind.py --status
199
200    See ``dpdk-devbind.py --help`` for more details.
201
202
203 More details about DPDK setup and Linux kernel requirements see :ref:`linux_gsg_compiling_dpdk`.
204
205
206 Example of getting best performance for an Intel NIC
207 ----------------------------------------------------
208
209 The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with an
210 Intel server platform and Intel XL710 NICs.
211 For specific 40G NIC configuration please refer to the i40e NIC guide.
212
213 The example scenario is to get best performance with two Intel XL710 40GbE ports.
214 See :numref:`figure_intel_perf_test_setup` for the performance test setup.
215
216 .. _figure_intel_perf_test_setup:
217
218 .. figure:: img/intel_perf_test_setup.*
219
220    Performance Test Setup
221
222
223 1. Add two Intel XL710 NICs to the platform, and use one port per card to get best performance.
224    The reason for using two NICs is to overcome a PCIe Gen3's limitation since it cannot provide 80G bandwidth
225    for two 40G ports, but two different PCIe Gen3 x8 slot can.
226    Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
227
228       82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
229       85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
230
231 2. Connect the ports to the traffic generator. For high speed testing, it's best to use a hardware traffic generator.
232
233 3. Check the PCI devices numa node (socket id) and get the cores number on the exact socket id.
234    In this case, ``82:00.0`` and ``85:00.0`` are both in socket 1, and the cores on socket 1 in the referenced platform
235    are 18-35 and 54-71.
236    Note: Don't use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical
237    cores from different cores (e.g core18 and core19).
238
239 4. Bind these two ports to igb_uio.
240
241 5. As to XL710 40G port, we need at least two queue pairs to achieve best performance, then two queues per port
242    will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
243
244 6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
245    Compile the ``l3fwd sample`` with the default lpm mode.
246
247 7. The command line of running l3fwd would be something like the followings::
248
249       ./l3fwd -c 0x3c0000 -n 4 -w 82:00.0 -w 85:00.0 \
250               -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
251
252    This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
253    core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
254
255
256 8. Configure the traffic at a traffic generator.
257
258    * Start creating a stream on packet generator.