5 ENIC Poll Mode Driver
6 =====================
7
8 ENIC PMD is the DPDK poll-mode driver for the Cisco System Inc. VIC Ethernet
9 NICs. These adapters are also referred to as vNICs below. If you are running
10 or would like to run DPDK software applications on Cisco UCS servers using
11 Cisco VIC adapters the following documentation is relevant.
12
13 How to obtain ENIC PMD integrated DPDK
14 --------------------------------------
15
16 ENIC PMD support is integrated into the DPDK suite. dpdk-<version>.tar.gz
17 should be downloaded from http://core.dpdk.org/download/
18
19
20 Configuration information
21 -------------------------
22
23 - **DPDK Configuration Parameters**
24
25   The following configuration options are available for the ENIC PMD:
26
27   - **CONFIG_RTE_LIBRTE_ENIC_PMD** (default y): Enables or disables inclusion
28     of the ENIC PMD driver in the DPDK compilation.
29
30 - **vNIC Configuration Parameters**
31
32   - **Number of Queues**
33
34     The maximum number of receive queues (RQs), work queues (WQs) and
35     completion queues (CQs) are configurable on a per vNIC basis
36     through the Cisco UCS Manager (CIMC or UCSM).
37
38     These values should be configured as follows:
39
40     - The number of WQs should be greater or equal to the value of the
41       expected nb_tx_q parameter in the call to
42       rte_eth_dev_configure()
43
44     - The number of RQs configured in the vNIC should be greater or
45       equal to *twice* the value of the expected nb_rx_q parameter in
46       the call to rte_eth_dev_configure().  With the addition of Rx
47       scatter, a pair of RQs on the vnic is needed for each receive
48       queue used by DPDK, even if Rx scatter is not being used.
49       Having a vNIC with only 1 RQ is not a valid configuration, and
50       will fail with an error message.
51
52     - The number of CQs should set so that there is one CQ for each
53       WQ, and one CQ for each pair of RQs.
54
55     For example: If the application requires 3 Rx queues, and 3 Tx
56     queues, the vNIC should be configured to have at least 3 WQs, 6
57     RQs (3 pairs), and 6 CQs (3 for use by WQs + 3 for use by the 3
58     pairs of RQs).
59
60   - **Size of Queues**
61
62     Likewise, the number of receive and transmit descriptors are configurable on
63     a per-vNIC basis via the UCS Manager and should be greater than or equal to
64     the nb_rx_desc and   nb_tx_desc parameters expected to be used in the calls
65     to rte_eth_rx_queue_setup() and rte_eth_tx_queue_setup() respectively.
66     An application requesting more than the set size will be limited to that
67     size.
68
69     Unless there is a lack of resources due to creating many vNICs, it
70     is recommended that the WQ and RQ sizes be set to the maximum.  This
71     gives the application the greatest amount of flexibility in its
72     queue configuration.
73
74     - *Note*: Since the introduction of Rx scatter, for performance
75       reasons, this PMD uses two RQs on the vNIC per receive queue in
76       DPDK.  One RQ holds descriptors for the start of a packet, and the
77       second RQ holds the descriptors for the rest of the fragments of
78       a packet.  This means that the nb_rx_desc parameter to
79       rte_eth_rx_queue_setup() can be a greater than 4096.  The exact
80       amount will depend on the size of the mbufs being used for
81       receives, and the MTU size.
82
83       For example: If the mbuf size is 2048, and the MTU is 9000, then
84       receiving a full size packet will take 5 descriptors, 1 from the
85       start-of-packet queue, and 4 from the second queue.  Assuming
86       that the RQ size was set to the maximum of 4096, then the
87       application can specify up to 1024 + 4096 as the nb_rx_desc
88       parameter to rte_eth_rx_queue_setup().
89
90   - **Interrupts**
91
92     At least one interrupt per vNIC interface should be configured in the UCS
93     manager regardless of the number receive/transmit queues. The ENIC PMD
94     uses this interrupt to get information about link status and errors
95     in the fast path.
96
97     In addition to the interrupt for link status and errors, when using Rx queue
98     interrupts, increase the number of configured interrupts so that there is at
99     least one interrupt for each Rx queue. For example, if the app uses 3 Rx
100     queues and wants to use per-queue interrupts, configure 4 (3 + 1) interrupts.
101
102   - **Receive Side Scaling**
103
104     In order to fully utilize RSS in DPDK, enable all RSS related settings in
105     CIMC or UCSM. These include the following items listed under
106     Receive Side Scaling:
107     TCP, IPv4, TCP-IPv4, IPv6, TCP-IPv6, IPv6 Extension, TCP-IPv6 Extension.
108
109
110 SR-IOV mode utilization
111 -----------------------
112
113 UCS blade servers configured with dynamic vNIC connection policies in UCSM
114 are capable of supporting SR-IOV. SR-IOV virtual functions (VFs) are
115 specialized vNICs, distinct from regular Ethernet vNICs. These VFs can be
116 directly assigned to virtual machines (VMs) as 'passthrough' devices.
117
118 In UCS, SR-IOV VFs require the use of the Cisco Virtual Machine Fabric Extender
119 (VM-FEX), which gives the VM a dedicated
120 interface on the Fabric Interconnect (FI). Layer 2 switching is done at
121 the FI. This may eliminate the requirement for software switching on the
122 host to route intra-host VM traffic.
123
124 Please refer to `Creating a Dynamic vNIC Connection Policy
125 <http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/vm_fex/vmware/gui/config_guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide_chapter_010.html#task_433E01651F69464783A68E66DA8A47A5>`_
126 for information on configuring SR-IOV adapter policies and port profiles
127 using UCSM.
128
129 Once the policies are in place and the host OS is rebooted, VFs should be
130 visible on the host, E.g.:
131
132 .. code-block:: console
133
134      # lspci | grep Cisco | grep Ethernet
135      0d:00.0 Ethernet controller: Cisco Systems Inc VIC Ethernet NIC (rev a2)
136      0d:00.1 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
137      0d:00.2 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
138      0d:00.3 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
139      0d:00.4 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
140      0d:00.5 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
141      0d:00.6 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
142      0d:00.7 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
143
144 Enable Intel IOMMU on the host and install KVM and libvirt, and reboot again as
145 required. Then, using libvirt, create a VM instance with an assigned device.
146 Below is an example ``interface`` block (part of the domain configuration XML)
147 that adds the host VF 0d:00:01 to the VM. ``profileid='pp-vlan-25'`` indicates
148 the port profile that has been configured in UCSM.
149
150 .. code-block:: console
151
152     <interface type='hostdev' managed='yes'>
153       <mac address='52:54:00:ac:ff:b6'/>
154       <driver name='vfio'/>
155       <source>
156         <address type='pci' domain='0x0000' bus='0x0d' slot='0x00' function='0x1'/>
157       </source>
158       <virtualport type='802.1Qbh'>
159         <parameters profileid='pp-vlan-25'/>
160       </virtualport>
161     </interface>
162
163
164 Alternatively, the configuration can be done in a separate file using the
165 ``network`` keyword. These methods are described in the libvirt documentation for
166 `Network XML format <https://libvirt.org/formatnetwork.html>`_.
167
168 When the VM instance is started, libvirt will bind the host VF to
169 vfio, complete provisioning on the FI and bring up the link.
170
171 .. note::
172
173     It is not possible to use a VF directly from the host because it is not
174     fully provisioned until libvirt brings up the VM that it is assigned
175     to.
176
177 In the VM instance, the VF will now be visible. E.g., here the VF 00:04.0 is
178 seen on the VM instance and should be available for binding to a DPDK.
179
180 .. code-block:: console
181
182      # lspci | grep Ether
183      00:04.0 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
184
185 Follow the normal DPDK install procedure, binding the VF to either ``igb_uio``
186 or ``vfio`` in non-IOMMU mode.
187
188 In the VM, the kernel enic driver may be automatically bound to the VF during
189 boot. Unbinding it currently hangs due to a known issue with the driver. To
190 work around the issue, blacklist the enic module as follows.
191 Please see :ref:`Limitations <enic_limitations>` for limitations in
192 the use of SR-IOV.
193
194 .. code-block:: console
195
196      # cat /etc/modprobe.d/enic.conf
197      blacklist enic
198
199      # dracut --force
200
201 .. note::
202
203     Passthrough does not require SR-IOV. If VM-FEX is not desired, the user
204     may create as many regular vNICs as necessary and assign them to VMs as
205     passthrough devices. Since these vNICs are not SR-IOV VFs, using them as
206     passthrough devices do not require libvirt, port profiles, and VM-FEX.
207
208
209 .. _enic-generic-flow-api:
210
211 Generic Flow API support
212 ------------------------
213
214 Generic Flow API (also called "rte_flow" API) is supported. More advanced
215 capabilities are available when "Advanced Filtering" is enabled on the adapter.
216 Advanced filtering was added to 1300 series VIC firmware starting with version
217 2.0.13 for C-series UCS servers and version 3.1.2 for UCSM managed blade
218 servers. Advanced filtering is available on 1400 series adapters and beyond.
219 To enable advanced filtering, the 'Advanced filter' radio button should be
220 selected via CIMC or UCSM followed by a reboot of the server.
221
222 - **1200 series VICs**
223
224   5-tuple exact flow support for 1200 series adapters. This allows:
225
226   - Attributes: ingress
227   - Items: ipv4, ipv6, udp, tcp (must exactly match src/dst IP
228     addresses and ports and all must be specified)
229   - Actions: queue and void
230   - Selectors: 'is'
231
232 - **1300 and later series VICS with advanced filters disabled**
233
234   With advanced filters disabled, an IPv4 or IPv6 item must be specified
235   in the pattern.
236
237   - Attributes: ingress
238   - Items: eth, vlan, ipv4, ipv6, udp, tcp, vxlan, inner eth, vlan, ipv4, ipv6, udp, tcp
239   - Actions: queue and void
240   - Selectors: 'is', 'spec' and 'mask'. 'last' is not supported
241   - In total, up to 64 bytes of mask is allowed across all headers
242
243 - **1300 and later series VICS with advanced filters enabled**
244
245   - Attributes: ingress
246   - Items: eth, vlan, ipv4, ipv6, udp, tcp, vxlan, raw, inner eth, vlan, ipv4, ipv6, udp, tcp
247   - Actions: queue, mark, drop, flag, rss, passthru, and void
248   - Selectors: 'is', 'spec' and 'mask'. 'last' is not supported
249   - In total, up to 64 bytes of mask is allowed across all headers
250
251 The VIC performs packet matching after applying VLAN strip. If VLAN
252 stripping is enabled, EtherType in the ETH item corresponds to the
253 stripped VLAN header's EtherType. Stripping does not affect the VLAN
254 item. TCI and EtherType in the VLAN item are matched against those in
255 the (stripped) VLAN header whether stripping is enabled or disabled.
256
257 More features may be added in future firmware and new versions of the VIC.
258 Please refer to the release notes.
259
260 .. _overlay_offload:
261
262 Overlay Offload
263 ---------------
264
265 Recent hardware models support overlay offload. When enabled, the NIC performs
266 the following operations for VXLAN, NVGRE, and GENEVE packets. In all cases,
267 inner and outer packets can be IPv4 or IPv6.
268
269 - TSO for VXLAN and GENEVE packets.
270
271   Hardware supports NVGRE TSO, but DPDK currently has no NVGRE offload flags.
272
273 - Tx checksum offloads.
274
275   The NIC fills in IPv4/UDP/TCP checksums for both inner and outer packets.
276
277 - Rx checksum offloads.
278
279   The NIC validates IPv4/UDP/TCP checksums of both inner and outer packets.
280   Good checksum flags (e.g. ``PKT_RX_L4_CKSUM_GOOD``) indicate that the inner
281   packet has the correct checksum, and if applicable, the outer packet also
282   has the correct checksum. Bad checksum flags (e.g. ``PKT_RX_L4_CKSUM_BAD``)
283   indicate that the inner and/or outer packets have invalid checksum values.
284
285 - Inner Rx packet type classification
286
287   PMD sets inner L3/L4 packet types (e.g. ``RTE_PTYPE_INNER_L4_TCP``), and
288   ``RTE_PTYPE_TUNNEL_GRENAT`` to indicate that the packet is tunneled.
289   PMD does not set L3/L4 packet types for outer packets.
290
291 - Inner RSS
292
293   RSS hash calculation, therefore queue selection, is done on inner packets.
294
295 In order to enable overlay offload, the 'Enable VXLAN' box should be checked
296 via CIMC or UCSM followed by a reboot of the server. When PMD successfully
297 enables overlay offload, it prints the following message on the console.
298
299 .. code-block:: console
300
301     Overlay offload is enabled
302
303 By default, PMD enables overlay offload if hardware supports it. To disable
304 it, set ``devargs`` parameter ``disable-overlay=1``. For example::
305
306     -w 12:00.0,disable-overlay=1
307
308 By default, the NIC uses 4789 as the VXLAN port. The user may change
309 it through ``rte_eth_dev_udp_tunnel_port_{add,delete}``. However, as
310 the current NIC has a single VXLAN port number, the user cannot
311 configure multiple port numbers.
312
313 Ingress VLAN Rewrite
314 --------------------
315
316 VIC adapters can tag, untag, or modify the VLAN headers of ingress
317 packets. The ingress VLAN rewrite mode controls this behavior. By
318 default, it is set to pass-through, where the NIC does not modify the
319 VLAN header in any way so that the application can see the original
320 header. This mode is sufficient for many applications, but may not be
321 suitable for others. Such applications may change the mode by setting
322 ``devargs`` parameter ``ig-vlan-rewrite`` to one of the following.
323
324 - ``pass``: Pass-through mode. The NIC does not modify the VLAN
325   header. This is the default mode.
326
327 - ``priority``: Priority-tag default VLAN mode. If the ingress packet
328   is tagged with the default VLAN, the NIC replaces its VLAN header
329   with the priority tag (VLAN ID 0).
330
331 - ``trunk``: Default trunk mode. The NIC tags untagged ingress packets
332   with the default VLAN. Tagged ingress packets are not modified. To
333   the application, every packet appears as tagged.
334
335 - ``untag``: Untag default VLAN mode. If the ingress packet is tagged
336   with the default VLAN, the NIC removes or untags its VLAN header so
337   that the application sees an untagged packet. As a result, the
338   default VLAN becomes `untagged`. This mode can be useful for
339   applications such as OVS-DPDK performance benchmarks that utilize
340   only the default VLAN and want to see only untagged packets.
341
342
343 Vectorized Rx Handler
344 ---------------------
345
346 ENIC PMD includes a version of the receive handler that is vectorized using
347 AVX2 SIMD instructions. It is meant for bulk, throughput oriented workloads
348 where reducing cycles/packet in PMD is a priority. In order to use the
349 vectorized handler, take the following steps.
350
351 - Use a recent version of gcc, icc, or clang and build 64-bit DPDK. If
352   the compiler is known to support AVX2, DPDK build system
353   automatically compiles the vectorized handler. Otherwise, the
354   handler is not available.
355
356 - Set ``devargs`` parameter ``enable-avx2-rx=1`` to explicitly request that
357   PMD consider the vectorized handler when selecting the receive handler.
358   For example::
359
360     -w 12:00.0,enable-avx2-rx=1
361
362   As the current implementation is intended for field trials, by default, the
363   vectorized handler is not considered (``enable-avx2-rx=0``).
364
365 - Run on a UCS M4 or later server with CPUs that support AVX2.
366
367 PMD selects the vectorized handler when the handler is compiled into
368 the driver, the user requests its use via ``enable-avx2-rx=1``, CPU
369 supports AVX2, and scatter Rx is not used. To verify that the
370 vectorized handler is selected, enable debug logging
371 (``--log-level=pmd,debug``) and check the following message.
372
373 .. code-block:: console
374
375     enic_use_vector_rx_handler use the non-scatter avx2 Rx handler
376
377 .. _enic_limitations:
378
379 Limitations
380 -----------
381
382 - **VLAN 0 Priority Tagging**
383
384   If a vNIC is configured in TRUNK mode by the UCS manager, the adapter will
385   priority tag egress packets according to 802.1Q if they were not already
386   VLAN tagged by software. If the adapter is connected to a properly configured
387   switch, there will be no unexpected behavior.
388
389   In test setups where an Ethernet port of a Cisco adapter in TRUNK mode is
390   connected point-to-point to another adapter port or connected though a router
391   instead of a switch, all ingress packets will be VLAN tagged. Programs such
392   as l3fwd may not account for VLAN tags in packets and may misbehave. One
393   solution is to enable VLAN stripping on ingress so the VLAN tag is removed
394   from the packet and put into the mbuf->vlan_tci field. Here is an example
395   of how to accomplish this:
396
397 .. code-block:: console
398
399      vlan_offload = rte_eth_dev_get_vlan_offload(port);
400      vlan_offload |= ETH_VLAN_STRIP_OFFLOAD;
401      rte_eth_dev_set_vlan_offload(port, vlan_offload);
402
403 Another alternative is modify the adapter's ingress VLAN rewrite mode so that
404 packets with the default VLAN tag are stripped by the adapter and presented to
405 DPDK as untagged packets. In this case mbuf->vlan_tci and the PKT_RX_VLAN and
406 PKT_RX_VLAN_STRIPPED mbuf flags would not be set. This mode is enabled with the
407 ``devargs`` parameter ``ig-vlan-rewrite=untag``. For example::
408
409     -w 12:00.0,ig-vlan-rewrite=untag
410
411 - **SR-IOV**
412
413   - KVM hypervisor support only. VMware has not been tested.
414   - Requires VM-FEX, and so is only available on UCS managed servers connected
415     to Fabric Interconnects. It is not on standalone C-Series servers.
416   - VF devices are not usable directly from the host. They can  only be used
417     as assigned devices on VM instances.
418   - Currently, unbind of the ENIC kernel mode driver 'enic.ko' on the VM
419     instance may hang. As a workaround, enic.ko should be blacklisted or removed
420     from the boot process.
421   - pci_generic cannot be used as the uio module in the VM. igb_uio or
422     vfio in non-IOMMU mode can be used.
423   - The number of RQs in UCSM dynamic vNIC configurations must be at least 2.
424   - The number of SR-IOV devices is limited to 256. Components on target system
425     might limit this number to fewer than 256.
426
427 - **Flow API**
428
429   - The number of filters that can be specified with the Generic Flow API is
430     dependent on how many header fields are being masked. Use 'flow create' in
431     a loop to determine how many filters your VIC will support (not more than
432     1000 for 1300 series VICs). Filters are checked for matching in the order they
433     were added. Since there currently is no grouping or priority support,
434     'catch-all' filters should be added last.
435   - The supported range of IDs for the 'MARK' action is 0 - 0xFFFD.
436   - RSS and PASSTHRU actions only support "receive normally". They are limited
437     to supporting MARK + RSS and PASSTHRU + MARK to allow the application to mark
438     packets and then receive them normally. These require 1400 series VIC adapters
439     and latest firmware.
440   - RAW items are limited to matching UDP tunnel headers like VXLAN.
441
442 - **Statistics**
443
444   - ``rx_good_bytes`` (ibytes) always includes VLAN header (4B) and CRC bytes (4B).
445     This behavior applies to 1300 and older series VIC adapters.
446     1400 series VICs do not count CRC bytes, and count VLAN header only when VLAN
447     stripping is disabled.
448   - When the NIC drops a packet because the Rx queue has no free buffers,
449     ``rx_good_bytes`` still increments by 4B if the packet is not VLAN tagged or
450     VLAN stripping is disabled, or by 8B if the packet is VLAN tagged and stripping
451     is enabled.
452     This behavior applies to 1300 and older series VIC adapters. 1400 series VICs
453     do not increment this byte counter when packets are dropped.
454
455 - **RSS Hashing**
456
457   - Hardware enables and disables UDP and TCP RSS hashing together. The driver
458     cannot control UDP and TCP hashing individually.
459
460 How to build the suite
461 ----------------------
462
463 The build instructions for the DPDK suite should be followed. By default
464 the ENIC PMD library will be built into the DPDK library.
465
466 Refer to the document :ref:`compiling and testing a PMD for a NIC
467 <pmd_build_and_test>` for details.
468
469 For configuring and using UIO and VFIO frameworks, please refer to the
470 documentation that comes with DPDK suite.
471
472 Supported Cisco VIC adapters
473 ----------------------------
474
475 ENIC PMD supports all recent generations of Cisco VIC adapters including:
476
477 - VIC 1200 series
478 - VIC 1300 series
479 - VIC 1400 series
480
481 Supported Operating Systems
482 ---------------------------
483
484 Any Linux distribution fulfilling the conditions described in Dependencies
485 section of DPDK documentation.
486
487 Supported features
488 ------------------
489
490 - Unicast, multicast and broadcast transmission and reception
491 - Receive queue polling
492 - Port Hardware Statistics
493 - Hardware VLAN acceleration
494 - IP checksum offload
495 - Receive side VLAN stripping
496 - Multiple receive and transmit queues
497 - Promiscuous mode
498 - Setting RX VLAN (supported via UCSM/CIMC only)
499 - VLAN filtering (supported via UCSM/CIMC only)
500 - Execution of application by unprivileged system users
501 - IPV4, IPV6 and TCP RSS hashing
502 - UDP RSS hashing (1400 series and later adapters)
503 - Scattered Rx
504 - MTU update
505 - SR-IOV on UCS managed servers connected to Fabric Interconnects
506 - Flow API
507 - Overlay offload
508
509   - Rx/Tx checksum offloads for VXLAN, NVGRE, GENEVE
510   - TSO for VXLAN and GENEVE packets
511   - Inner RSS
512
513 Known bugs and unsupported features in this release
514 ---------------------------------------------------
515
516 - Signature or flex byte based flow direction
517 - Drop feature of flow direction
518 - VLAN based flow direction
519 - Non-IPV4 flow direction
520 - Setting of extended VLAN
521 - MTU update only works if Scattered Rx mode is disabled
522 - Maximum receive packet length is ignored if Scattered Rx mode is used
523
524 Prerequisites
525 -------------
526
527 - Prepare the system as recommended by DPDK suite.  This includes environment
528   variables, hugepages configuration, tool-chains and configuration.
529 - Insert vfio-pci kernel module using the command 'modprobe vfio-pci' if the
530   user wants to use VFIO framework.
531 - Insert uio kernel module using the command 'modprobe uio' if the user wants
532   to use UIO framework.
533 - DPDK suite should be configured based on the user's decision to use VFIO or
534   UIO framework.
535 - If the vNIC device(s) to be used is bound to the kernel mode Ethernet driver
536   use 'ip' to bring the interface down. The dpdk-devbind.py tool can
537   then be used to unbind the device's bus id from the ENIC kernel mode driver.
538 - Bind the intended vNIC to vfio-pci in case the user wants ENIC PMD to use
539   VFIO framework using dpdk-devbind.py.
540 - Bind the intended vNIC to igb_uio in case the user wants ENIC PMD to use
541   UIO framework using dpdk-devbind.py.
542
543 At this point the system should be ready to run DPDK applications. Once the
544 application runs to completion, the vNIC can be detached from vfio-pci or
545 igb_uio if necessary.
546
547 Root privilege is required to bind and unbind vNICs to/from VFIO/UIO.
548 VFIO framework helps an unprivileged user to run the applications.
549 For an unprivileged user to run the applications on DPDK and ENIC PMD,
550 it may be necessary to increase the maximum locked memory of the user.
551 The following command could be used to do this.
552
553 .. code-block:: console
554
555     sudo sh -c "ulimit -l <value in Kilo Bytes>"
556
557 The value depends on the memory configuration of the application, DPDK and
558 PMD.  Typically, the limit has to be raised to higher than 2GB.
559 e.g., 2621440
560
561 The compilation of any unused drivers can be disabled using the
562 configuration file in config/ directory (e.g., config/common_linux).
563 This would help in bringing down the time taken for building the
564 libraries and the initialization time of the application.
565
566 Additional Reference
567 --------------------
568
569 - https://www.cisco.com/c/en/us/products/servers-unified-computing/index.html
570 - https://www.cisco.com/c/en/us/products/interfaces-modules/unified-computing-system-adapters/index.html
571
572 Contact Information
573 -------------------
574
575 Any questions or bugs should be reported to DPDK community and to the ENIC PMD
576 maintainers:
577
578 - John Daley <johndale@cisco.com>
579 - Hyong Youb Kim <hyonkim@cisco.com>