net/i40e: determine number of queues per VF at run time
[dpdk.git] / doc / guides / nics / i40e.rst
1 ..  BSD LICENSE
2     Copyright(c) 2016 Intel Corporation. All rights reserved.
3     All rights reserved.
4
5     Redistribution and use in source and binary forms, with or without
6     modification, are permitted provided that the following conditions
7     are met:
8
9     * Redistributions of source code must retain the above copyright
10     notice, this list of conditions and the following disclaimer.
11     * Redistributions in binary form must reproduce the above copyright
12     notice, this list of conditions and the following disclaimer in
13     the documentation and/or other materials provided with the
14     distribution.
15     * Neither the name of Intel Corporation nor the names of its
16     contributors may be used to endorse or promote products derived
17     from this software without specific prior written permission.
18
19     THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
20     "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
21     LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
22     A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
23     OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
24     SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
25     LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
26     DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
27     THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
28     (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
29     OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
30
31 I40E Poll Mode Driver
32 ======================
33
34 The I40E PMD (librte_pmd_i40e) provides poll mode driver support
35 for the Intel X710/XL710/X722 10/40 Gbps family of adapters.
36
37
38 Features
39 --------
40
41 Features of the I40E PMD are:
42
43 - Multiple queues for TX and RX
44 - Receiver Side Scaling (RSS)
45 - MAC/VLAN filtering
46 - Packet type information
47 - Flow director
48 - Cloud filter
49 - Checksum offload
50 - VLAN/QinQ stripping and inserting
51 - TSO offload
52 - Promiscuous mode
53 - Multicast mode
54 - Port hardware statistics
55 - Jumbo frames
56 - Link state information
57 - Link flow control
58 - Mirror on port, VLAN and VSI
59 - Interrupt mode for RX
60 - Scattered and gather for TX and RX
61 - Vector Poll mode driver
62 - DCB
63 - VMDQ
64 - SR-IOV VF
65 - Hot plug
66 - IEEE1588/802.1AS timestamping
67 - VF Daemon (VFD) - EXPERIMENTAL
68
69
70 Prerequisites
71 -------------
72
73 - Identifying your adapter using `Intel Support
74   <http://www.intel.com/support>`_ and get the latest NVM/FW images.
75
76 - Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
77
78 - To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms"
79   section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
80
81 - Upgrade the NVM/FW version following the `IntelĀ® Ethernet NVM Update Tool Quick Usage Guide for Linux
82   <https://www-ssl.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-linux-usage-guide.html>`_ if needed.
83
84 Pre-Installation Configuration
85 ------------------------------
86
87 Config File Options
88 ~~~~~~~~~~~~~~~~~~~
89
90 The following options can be modified in the ``config`` file.
91 Please note that enabling debugging options may affect system performance.
92
93 - ``CONFIG_RTE_LIBRTE_I40E_PMD`` (default ``y``)
94
95   Toggle compilation of the ``librte_pmd_i40e`` driver.
96
97 - ``CONFIG_RTE_LIBRTE_I40E_DEBUG_*`` (default ``n``)
98
99   Toggle display of generic debugging messages.
100
101 - ``CONFIG_RTE_LIBRTE_I40E_RX_ALLOW_BULK_ALLOC`` (default ``y``)
102
103   Toggle bulk allocation for RX.
104
105 - ``CONFIG_RTE_LIBRTE_I40E_INC_VECTOR`` (default ``n``)
106
107   Toggle the use of Vector PMD instead of normal RX/TX path.
108   To enable vPMD for RX, bulk allocation for Rx must be allowed.
109
110 - ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` (default ``n``)
111
112   Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte.
113
114 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
115
116   Number of queues reserved for PF.
117
118 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
119
120   Number of queues reserved for each VMDQ Pool.
121
122 - ``CONFIG_RTE_LIBRTE_I40E_ITR_INTERVAL`` (default ``-1``)
123
124   Interrupt Throttling interval.
125
126
127 Runtime Config Options
128 ~~~~~~~~~~~~~~~~~~~~~~
129
130 - ``Number of Queues per VF`` (default ``4``)
131
132   The number of queue per VF is determined by its host PF. If the PCI address
133   of an i40e PF is aaaa:bb.cc, the number of queues per VF can be configured
134   with EAL parameter like -w aaaa:bb.cc,queue-num-per-vf=n. The value n can be
135   1, 2, 4, 8 or 16. If no such parameter is configured, the number of queues
136   per VF is 4 by default.
137
138
139 Driver compilation and testing
140 ------------------------------
141
142 Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
143 for details.
144
145
146 SR-IOV: Prerequisites and sample Application Notes
147 --------------------------------------------------
148
149 #. Load the kernel module:
150
151    .. code-block:: console
152
153       modprobe i40e
154
155    Check the output in dmesg:
156
157    .. code-block:: console
158
159       i40e 0000:83:00.1 ens802f0: renamed from eth0
160
161 #. Bring up the PF ports:
162
163    .. code-block:: console
164
165       ifconfig ens802f0 up
166
167 #. Create VF device(s):
168
169    Echo the number of VFs to be created into the ``sriov_numvfs`` sysfs entry
170    of the parent PF.
171
172    Example:
173
174    .. code-block:: console
175
176       echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
177
178
179 #. Assign VF MAC address:
180
181    Assign MAC address to the VF using iproute2 utility. The syntax is:
182
183    .. code-block:: console
184
185       ip link set <PF netdev id> vf <VF id> mac <macaddr>
186
187    Example:
188
189    .. code-block:: console
190
191       ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0
192
193 #. Assign VF to VM, and bring up the VM.
194    Please see the documentation for the *I40E/IXGBE/IGB Virtual Function Driver*.
195
196 #. Running testpmd:
197
198    Follow instructions available in the document
199    :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
200    to run testpmd.
201
202    Example output:
203
204    .. code-block:: console
205
206       ...
207       EAL: PCI device 0000:83:00.0 on NUMA socket 1
208       EAL: probe driver: 8086:1572 rte_i40e_pmd
209       EAL: PCI memory mapped at 0x7f7f80000000
210       EAL: PCI memory mapped at 0x7f7f80800000
211       PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a
212       Interactive-mode selected
213       Configuring Port 0 (socket 0)
214       ...
215
216       PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are
217       satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0.
218
219       ...
220       Port 0: 68:05:CA:26:85:84
221       Checking link statuses...
222       Port 0 Link Up - speed 10000 Mbps - full-duplex
223       Done
224
225       testpmd>
226
227
228 Sample Application Notes
229 ------------------------
230
231 Vlan filter
232 ~~~~~~~~~~~
233
234 Vlan filter only works when Promiscuous mode is off.
235
236 To start ``testpmd``, and add vlan 10 to port 0:
237
238 .. code-block:: console
239
240     ./app/testpmd -l 0-15 -n 4 -- -i --forward-mode=mac
241     ...
242
243     testpmd> set promisc 0 off
244     testpmd> rx_vlan add 10 0
245
246
247 Flow Director
248 ~~~~~~~~~~~~~
249
250 The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
251 The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload.
252
253 The default input set of each flow type is::
254
255    ipv4-other : src_ip_address, dst_ip_address
256    ipv4-frag  : src_ip_address, dst_ip_address
257    ipv4-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
258    ipv4-udp   : src_ip_address, dst_ip_address, src_port, dst_port
259    ipv4-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
260                 verification_tag
261    ipv6-other : src_ip_address, dst_ip_address
262    ipv6-frag  : src_ip_address, dst_ip_address
263    ipv6-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
264    ipv6-udp   : src_ip_address, dst_ip_address, src_port, dst_port
265    ipv6-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
266                 verification_tag
267    l2_payload : ether_type
268
269 The flex payload is selected from offset 0 to 15 of packet's payload by default, while it is masked out from matching.
270
271 Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``:
272
273 .. code-block:: console
274
275    ./app/testpmd -l 0-15 -n 4 -- -i --disable-rss --pkt-filter-mode=perfect \
276                  --rxq=8 --txq=8 --nb-cores=8 --nb-ports=1
277
278 Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1:
279
280 .. code-block:: console
281
282    testpmd> flow_director_filter 0 mode IP add flow ipv4-udp  \
283             src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \
284             fwd pf queue 1 fd_id 1
285
286 Check the flow director status:
287
288 .. code-block:: console
289
290    testpmd> show port fdir 0
291
292    ######################## FDIR infos for port 0      ####################
293      MODE:   PERFECT
294      SUPPORTED FLOW TYPE:  ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other
295                            ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other
296                            l2_payload
297      FLEX PAYLOAD INFO:
298      max_len:       16          payload_limit: 480
299      payload_unit:  2           payload_seg:   3
300      bitmask_unit:  2           bitmask_num:   2
301      MASK:
302        vlan_tci: 0x0000,
303        src_ipv4: 0x00000000,
304        dst_ipv4: 0x00000000,
305        src_port: 0x0000,
306        dst_port: 0x0000
307        src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000,
308        dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000
309      FLEX PAYLOAD SRC OFFSET:
310        L2_PAYLOAD:    0      1      2      3      4      5      6  ...
311        L3_PAYLOAD:    0      1      2      3      4      5      6  ...
312        L4_PAYLOAD:    0      1      2      3      4      5      6  ...
313      FLEX MASK CFG:
314        ipv4-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
315        ipv4-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
316        ipv4-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
317        ipv4-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
318        ipv4-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
319        ipv6-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
320        ipv6-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
321        ipv6-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
322        ipv6-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
323        ipv6-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
324        l2_payload:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
325      guarant_count: 1           best_count:    0
326      guarant_space: 512         best_space:    7168
327      collision:     0           free:          0
328      maxhash:       0           maxlen:        0
329      add:           0           remove:        0
330      f_add:         0           f_remove:      0
331
332
333 Delete all flow director rules on a port:
334
335 .. code-block:: console
336
337    testpmd> flush_flow_director 0
338
339 Floating VEB
340 ~~~~~~~~~~~~~
341
342 The IntelĀ® Ethernet Controller X710 and XL710 Family support a feature called
343 "Floating VEB".
344
345 A Virtual Ethernet Bridge (VEB) is an IEEE Edge Virtual Bridging (EVB) term
346 for functionality that allows local switching between virtual endpoints within
347 a physical endpoint and also with an external bridge/network.
348
349 A "Floating" VEB doesn't have an uplink connection to the outside world so all
350 switching is done internally and remains within the host. As such, this
351 feature provides security benefits.
352
353 In addition, a Floating VEB overcomes a limitation of normal VEBs where they
354 cannot forward packets when the physical link is down. Floating VEBs don't need
355 to connect to the NIC port so they can still forward traffic from VF to VF
356 even when the physical link is down.
357
358 Therefore, with this feature enabled VFs can be limited to communicating with
359 each other but not an outside network, and they can do so even when there is
360 no physical uplink on the associated NIC port.
361
362 To enable this feature, the user should pass a ``devargs`` parameter to the
363 EAL, for example::
364
365     -w 84:00.0,enable_floating_veb=1
366
367 In this configuration the PMD will use the floating VEB feature for all the
368 VFs created by this PF device.
369
370 Alternatively, the user can specify which VFs need to connect to this floating
371 VEB using the ``floating_veb_list`` argument::
372
373     -w 84:00.0,enable_floating_veb=1,floating_veb_list=1;3-4
374
375 In this example ``VF1``, ``VF3`` and ``VF4`` connect to the floating VEB,
376 while other VFs connect to the normal VEB.
377
378 The current implementation only supports one floating VEB and one regular
379 VEB. VFs can connect to a floating VEB or a regular VEB according to the
380 configuration passed on the EAL command line.
381
382 The floating VEB functionality requires a NIC firmware version of 5.0
383 or greater.
384
385
386 Limitations or Known issues
387 ---------------------------
388
389 MPLS packet classification on X710/XL710
390 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
391
392 For firmware versions prior to 5.0, MPLS packets are not recognized by the NIC.
393 The L2 Payload flow type in flow director can be used to classify MPLS packet
394 by using a command in testpmd like:
395
396    testpmd> flow_director_filter 0 mode IP add flow l2_payload ether \
397             0x8847 flexbytes () fwd pf queue <N> fd_id <M>
398
399 With the NIC firmware version 5.0 or greater, some limited MPLS support
400 is added: Native MPLS (MPLS in Ethernet) skip is implemented, while no
401 new packet type, no classification or offload are possible. With this change,
402 L2 Payload flow type in flow director cannot be used to classify MPLS packet
403 as with previous firmware versions. Meanwhile, the Ethertype filter can be
404 used to classify MPLS packet by using a command in testpmd like:
405
406    testpmd> ethertype_filter 0 add mac_ignr 00:00:00:00:00:00 ethertype \
407             0x8847 fwd queue <M>
408
409 16 Byte RX Descriptor setting on DPDK VF
410 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
411
412 Currently the VF's RX descriptor mode is decided by PF. There's no PF-VF
413 interface for VF to request the RX descriptor mode, also no interface to notify
414 VF its own RX descriptor mode.
415 For all available versions of the i40e driver, these drivers don't support 16
416 byte RX descriptor. If the Linux i40e kernel driver is used as host driver,
417 while DPDK i40e PMD is used as the VF driver, DPDK cannot choose 16 byte receive
418 descriptor. The reason is that the RX descriptor is already set to 32 byte by
419 the i40e kernel driver. That is to say, user should keep
420 ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC=n`` in config file.
421 In the future, if the Linux i40e driver supports 16 byte RX descriptor, user
422 should make sure the DPDK VF uses the same RX descriptor mode, 16 byte or 32
423 byte, as the PF driver.
424
425 The same rule for DPDK PF + DPDK VF. The PF and VF should use the same RX
426 descriptor mode. Or the VF RX will not work.
427
428 Receive packets with Ethertype 0x88A8
429 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
430
431 Due to the FW limitation, PF can receive packets with Ethertype 0x88A8
432 only when floating VEB is disabled.
433
434 Incorrect Rx statistics when packet is oversize
435 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
436
437 When a packet is over maximum frame size, the packet is dropped.
438 However the Rx statistics, when calling `rte_eth_stats_get` incorrectly
439 shows it as received.
440
441 VF & TC max bandwidth setting
442 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
443
444 The per VF max bandwidth and per TC max bandwidth cannot be enabled in parallel.
445 The dehavior is different when handling per VF and per TC max bandwidth setting.
446 When enabling per VF max bandwidth, SW will check if per TC max bandwidth is
447 enabled. If so, return failure.
448 When enabling per TC max bandwidth, SW will check if per VF max bandwidth
449 is enabled. If so, disable per VF max bandwidth and continue with per TC max
450 bandwidth setting.
451
452 TC TX scheduling mode setting
453 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
454
455 There're 2 TX scheduling modes for TCs, round robin and strict priority mode.
456 If a TC is set to strict priority mode, it can consume unlimited bandwidth.
457 It means if APP has set the max bandwidth for that TC, it comes to no
458 effect.
459 It's suggested to set the strict priority mode for a TC that is latency
460 sensitive but no consuming much bandwidth.
461
462 VF performance is impacted by PCI extended tag setting
463 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
464
465 To reach maximum NIC performance in the VF the PCI extended tag must be
466 enabled. The DPDK I40E PF driver will set this feature during initialization,
467 but the kernel PF driver does not. So when running traffic on a VF which is
468 managed by the kernel PF driver, a significant NIC performance downgrade has
469 been observed (for 64 byte packets, there is about 25% linerate downgrade for
470 a 25G device and about 35% for a 40G device).
471
472 For kernel version >= 4.11, the kernel's PCI driver will enable the extended
473 tag if it detects that the device supports it. So by default, this is not an
474 issue. For kernels <= 4.11 or when the PCI extended tag is disabled it can be
475 enabled using the steps below.
476
477 #. Get the current value of the PCI configure register::
478
479       setpci -s <XX:XX.X> a8.w
480
481 #. Set bit 8::
482
483       value = value | 0x100
484
485 #. Set the PCI configure register with new value::
486
487       setpci -s <XX:XX.X> a8.w=<value>
488
489 Vlan strip of VF
490 ~~~~~~~~~~~~~~~~
491
492 The VF vlan strip function is only supported in the i40e kernel driver >= 2.1.26.
493
494 DCB function
495 ~~~~~~~~~~~~
496
497 DCB works only when RSS is enabled.
498
499 High Performance of Small Packets on 40G NIC
500 --------------------------------------------
501
502 As there might be firmware fixes for performance enhancement in latest version
503 of firmware image, the firmware update might be needed for getting high performance.
504 Check with the local Intel's Network Division application engineers for firmware updates.
505 Users should consult the release notes specific to a DPDK release to identify
506 the validated firmware version for a NIC using the i40e driver.
507
508 Use 16 Bytes RX Descriptor Size
509 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
510
511 As i40e PMD supports both 16 and 32 bytes RX descriptor sizes, and 16 bytes size can provide helps to high performance of small packets.
512 Configuration of ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` in config files can be changed to use 16 bytes size RX descriptors.
513
514 High Performance and per Packet Latency Tradeoff
515 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
516
517 Due to the hardware design, the interrupt signal inside NIC is needed for per
518 packet descriptor write-back. The minimum interval of interrupts could be set
519 at compile time by ``CONFIG_RTE_LIBRTE_I40E_ITR_INTERVAL`` in configuration files.
520 Though there is a default configuration, the interval could be tuned by the
521 users with that configuration item depends on what the user cares about more,
522 performance or per packet latency.
523
524 Example of getting best performance with l3fwd example
525 ------------------------------------------------------
526
527 The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with an
528 Intel server platform and Intel XL710 NICs.
529
530 The example scenario is to get best performance with two Intel XL710 40GbE ports.
531 See :numref:`figure_intel_perf_test_setup` for the performance test setup.
532
533 .. _figure_intel_perf_test_setup:
534
535 .. figure:: img/intel_perf_test_setup.*
536
537    Performance Test Setup
538
539
540 1. Add two Intel XL710 NICs to the platform, and use one port per card to get best performance.
541    The reason for using two NICs is to overcome a PCIe Gen3's limitation since it cannot provide 80G bandwidth
542    for two 40G ports, but two different PCIe Gen3 x8 slot can.
543    Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
544
545       82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
546       85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
547
548 2. Connect the ports to the traffic generator. For high speed testing, it's best to use a hardware traffic generator.
549
550 3. Check the PCI devices numa node (socket id) and get the cores number on the exact socket id.
551    In this case, ``82:00.0`` and ``85:00.0`` are both in socket 1, and the cores on socket 1 in the referenced platform
552    are 18-35 and 54-71.
553    Note: Don't use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical
554    cores from different cores (e.g core18 and core19).
555
556 4. Bind these two ports to igb_uio.
557
558 5. As to XL710 40G port, we need at least two queue pairs to achieve best performance, then two queues per port
559    will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
560
561 6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
562    Compile the ``l3fwd sample`` with the default lpm mode.
563
564 7. The command line of running l3fwd would be something like the following::
565
566       ./l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \
567               -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
568
569    This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
570    core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
571
572 8. Configure the traffic at a traffic generator.
573
574    * Start creating a stream on packet generator.