fix PMD wording
[dpdk.git] / doc / guides / nics / intel_vf.rst
1 ..  SPDX-License-Identifier: BSD-3-Clause
2     Copyright(c) 2010-2014 Intel Corporation.
3
4 Intel Virtual Function Driver
5 =============================
6
7 Supported Intel® Ethernet Controllers (see the *DPDK Release Notes* for details)
8 support the following modes of operation in a virtualized environment:
9
10 *   **SR-IOV mode**: Involves direct assignment of part of the port resources to different guest operating systems
11     using the PCI-SIG Single Root I/O Virtualization (SR IOV) standard,
12     also known as "native mode" or "pass-through" mode.
13     In this chapter, this mode is referred to as IOV mode.
14
15 *   **VMDq mode**: Involves central management of the networking resources by an IO Virtual Machine (IOVM) or
16     a Virtual Machine Monitor (VMM), also known as software switch acceleration mode.
17     In this chapter, this mode is referred to as the Next Generation VMDq mode.
18
19 SR-IOV Mode Utilization in a DPDK Environment
20 ---------------------------------------------
21
22 The DPDK uses the SR-IOV feature for hardware-based I/O sharing in IOV mode.
23 Therefore, it is possible to partition SR-IOV capability on Ethernet controller NIC resources logically and
24 expose them to a virtual machine as a separate PCI function called a "Virtual Function".
25 Refer to :numref:`figure_single_port_nic`.
26
27 Therefore, a NIC is logically distributed among multiple virtual machines (as shown in :numref:`figure_single_port_nic`),
28 while still having global data in common to share with the Physical Function and other Virtual Functions.
29 The DPDK fm10kvf, iavf, igbvf or ixgbevf as a Poll Mode Driver (PMD) serves for the Intel® 82576 Gigabit Ethernet Controller,
30 Intel® Ethernet Controller I350 family, Intel® 82599 10 Gigabit Ethernet Controller NIC,
31 Intel® Fortville 10/40 Gigabit Ethernet Controller NIC's virtual PCI function, or PCIe host-interface of the Intel Ethernet Switch
32 FM10000 Series.
33 Meanwhile the DPDK Poll Mode Driver (PMD) also supports "Physical Function" of such NIC's on the host.
34
35 The DPDK PF/VF Poll Mode Driver (PMD) supports the Layer 2 switch on Intel® 82576 Gigabit Ethernet Controller,
36 Intel® Ethernet Controller I350 family, Intel® 82599 10 Gigabit Ethernet Controller,
37 and Intel® Fortville 10/40 Gigabit Ethernet Controller NICs so that guest can choose it for inter virtual machine traffic in SR-IOV mode.
38
39 For more detail on SR-IOV, please refer to the following documents:
40
41 *   `SR-IOV provides hardware based I/O sharing <http://www.intel.com/network/connectivity/solutions/vmdc.htm>`_
42
43 *   `PCI-SIG-Single Root I/O Virtualization Support on IA
44     <http://www.intel.com/content/www/us/en/pci-express/pci-sig-single-root-io-virtualization-support-in-virtualization-technology-for-connectivity-paper.html>`_
45
46 *   `Scalable I/O Virtualized Servers <http://www.intel.com/content/www/us/en/virtualization/server-virtualization/scalable-i-o-virtualized-servers-paper.html>`_
47
48 .. _figure_single_port_nic:
49
50 .. figure:: img/single_port_nic.*
51
52    Virtualization for a Single Port NIC in SR-IOV Mode
53
54
55 Physical and Virtual Function Infrastructure
56 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
57
58 The following describes the Physical Function and Virtual Functions infrastructure for the supported Ethernet Controller NICs.
59
60 Virtual Functions operate under the respective Physical Function on the same NIC Port and therefore have no access
61 to the global NIC resources that are shared between other functions for the same NIC port.
62
63 A Virtual Function has basic access to the queue resources and control structures of the queues assigned to it.
64 For global resource access, a Virtual Function has to send a request to the Physical Function for that port,
65 and the Physical Function operates on the global resources on behalf of the Virtual Function.
66 For this out-of-band communication, an SR-IOV enabled NIC provides a memory buffer for each Virtual Function,
67 which is called a "Mailbox".
68
69 Intel® Ethernet Adaptive Virtual Function
70 ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
71 Adaptive Virtual Function (IAVF) is a SR-IOV Virtual Function with the same device id (8086:1889) on different Intel Ethernet Controller.
72 IAVF Driver is VF driver which supports for all future Intel devices without requiring a VM update. And since this happens to be an adaptive VF driver,
73 every new drop of the VF driver would add more and more advanced features that can be turned on in the VM if the underlying HW device supports those
74 advanced features based on a device agnostic way without ever compromising on the base functionality. IAVF provides generic hardware interface and
75 interface between IAVF driver and a compliant PF driver is specified.
76
77 Intel products starting Ethernet Controller 700 Series to support Adaptive Virtual Function.
78
79 The way to generate Virtual Function is like normal, and the resource of VF assignment depends on the NIC Infrastructure.
80
81 For more detail on SR-IOV, please refer to the following documents:
82
83 *   `Intel® IAVF HAS <https://www.intel.com/content/dam/www/public/us/en/documents/product-specifications/ethernet-adaptive-virtual-function-hardware-spec.pdf>`_
84
85 .. note::
86
87     To use DPDK IAVF PMD on Intel® 700 Series Ethernet Controller, the device id (0x1889) need to specified during device
88     assignment in hypervisor. Take qemu for example, the device assignment should carry the IAVF device id (0x1889) like
89     ``-device vfio-pci,x-pci-device-id=0x1889,host=03:0a.0``.
90
91     When IAVF is backed by an Intel® E810 device, the "Protocol Extraction" feature which is supported by ice PMD is also
92     available for IAVF PMD. The same devargs with the same parameters can be applied to IAVF PMD, for detail please reference
93     the section ``Protocol extraction for per queue`` of ice.rst.
94
95 The PCIE host-interface of Intel Ethernet Switch FM10000 Series VF infrastructure
96 ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
97
98 In a virtualized environment, the programmer can enable a maximum of *64 Virtual Functions (VF)*
99 globally per PCIE host-interface of the Intel Ethernet Switch FM10000 Series device.
100 Each VF can have a maximum of 16 queue pairs.
101 The Physical Function in host could be only configured by the Linux* fm10k driver
102 (in the case of the Linux Kernel-based Virtual Machine [KVM]), DPDK PMD PF driver doesn't support it yet.
103
104 For example,
105
106 *   Using Linux* fm10k driver:
107
108     .. code-block:: console
109
110         rmmod fm10k (To remove the fm10k module)
111         insmod fm0k.ko max_vfs=2,2 (To enable two Virtual Functions per port)
112
113 Virtual Function enumeration is performed in the following sequence by the Linux* pci driver for a dual-port NIC.
114 When you enable the four Virtual Functions with the above command, the four enabled functions have a Function#
115 represented by (Bus#, Device#, Function#) in sequence starting from 0 to 3.
116 However:
117
118 *   Virtual Functions 0 and 2 belong to Physical Function 0
119
120 *   Virtual Functions 1 and 3 belong to Physical Function 1
121
122 .. note::
123
124     The above is an important consideration to take into account when targeting specific packets to a selected port.
125
126 Intel® X710/XL710 Gigabit Ethernet Controller VF Infrastructure
127 ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
128
129 In a virtualized environment, the programmer can enable a maximum of *128 Virtual Functions (VF)*
130 globally per Intel® X710/XL710 Gigabit Ethernet Controller NIC device.
131 The Physical Function in host could be either configured by the Linux* i40e driver
132 (in the case of the Linux Kernel-based Virtual Machine [KVM]) or by DPDK PMD PF driver.
133 When using both DPDK PMD PF/VF drivers, the whole NIC will be taken over by DPDK based application.
134
135 For example,
136
137 *   Using Linux* i40e  driver:
138
139     .. code-block:: console
140
141         rmmod i40e (To remove the i40e module)
142         insmod i40e.ko max_vfs=2,2 (To enable two Virtual Functions per port)
143
144 *   Using the DPDK PMD PF i40e driver:
145
146     Kernel Params: iommu=pt, intel_iommu=on
147
148     .. code-block:: console
149
150         modprobe uio
151         insmod igb_uio
152         ./dpdk-devbind.py -b igb_uio bb:ss.f
153         echo 2 > /sys/bus/pci/devices/0000\:bb\:ss.f/max_vfs (To enable two VFs on a specific PCI device)
154
155     Launch the DPDK testpmd/example or your own host daemon application using the DPDK PMD library.
156
157 Virtual Function enumeration is performed in the following sequence by the Linux* pci driver for a dual-port NIC.
158 When you enable the four Virtual Functions with the above command, the four enabled functions have a Function#
159 represented by (Bus#, Device#, Function#) in sequence starting from 0 to 3.
160 However:
161
162 *   Virtual Functions 0 and 2 belong to Physical Function 0
163
164 *   Virtual Functions 1 and 3 belong to Physical Function 1
165
166 .. note::
167
168     The above is an important consideration to take into account when targeting specific packets to a selected port.
169
170     For Intel® X710/XL710 Gigabit Ethernet Controller, queues are in pairs. One queue pair means one receive queue and
171     one transmit queue. The default number of queue pairs per VF is 4, and can be 16 in maximum.
172
173 Intel® 82599 10 Gigabit Ethernet Controller VF Infrastructure
174 ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
175
176 The programmer can enable a maximum of *63 Virtual Functions* and there must be *one Physical Function* per Intel® 82599
177 10 Gigabit Ethernet Controller NIC port.
178 The reason for this is that the device allows for a maximum of 128 queues per port and a virtual/physical function has to
179 have at least one queue pair (RX/TX).
180 The current implementation of the DPDK ixgbevf driver supports a single queue pair (RX/TX) per Virtual Function.
181 The Physical Function in host could be either configured by the Linux* ixgbe driver
182 (in the case of the Linux Kernel-based Virtual Machine [KVM]) or by DPDK PMD PF driver.
183 When using both DPDK PMD PF/VF drivers, the whole NIC will be taken over by DPDK based application.
184
185 For example,
186
187 *   Using Linux* ixgbe driver:
188
189     .. code-block:: console
190
191         rmmod ixgbe (To remove the ixgbe module)
192         insmod ixgbe max_vfs=2,2 (To enable two Virtual Functions per port)
193
194 *   Using the DPDK PMD PF ixgbe driver:
195
196     Kernel Params: iommu=pt, intel_iommu=on
197
198     .. code-block:: console
199
200         modprobe uio
201         insmod igb_uio
202         ./dpdk-devbind.py -b igb_uio bb:ss.f
203         echo 2 > /sys/bus/pci/devices/0000\:bb\:ss.f/max_vfs (To enable two VFs on a specific PCI device)
204
205     Launch the DPDK testpmd/example or your own host daemon application using the DPDK PMD library.
206
207 *   Using the DPDK PMD PF ixgbe driver to enable VF RSS:
208
209     Same steps as above to install the modules of uio, igb_uio, specify max_vfs for PCI device, and
210     launch the DPDK testpmd/example or your own host daemon application using the DPDK PMD library.
211
212     The available queue number (at most 4) per VF depends on the total number of pool, which is
213     determined by the max number of VF at PF initialization stage and the number of queue specified
214     in config:
215
216     *   If the max number of VFs (max_vfs) is set in the range of 1 to 32:
217
218         If the number of Rx queues is specified as 4 (``--rxq=4`` in testpmd), then there are totally 32
219         pools (RTE_ETH_32_POOLS), and each VF could have 4 Rx queues;
220
221         If the number of Rx queues is specified as 2 (``--rxq=2`` in testpmd), then there are totally 32
222         pools (RTE_ETH_32_POOLS), and each VF could have 2 Rx queues;
223
224     *   If the max number of VFs (max_vfs) is in the range of 33 to 64:
225
226         If the number of Rx queues in specified as 4 (``--rxq=4`` in testpmd), then error message is expected
227         as ``rxq`` is not correct at this case;
228
229         If the number of rxq is 2 (``--rxq=2`` in testpmd), then there is totally 64 pools (RTE_ETH_64_POOLS),
230         and each VF have 2 Rx queues;
231
232     On host, to enable VF RSS functionality, rx mq mode should be set as RTE_ETH_MQ_RX_VMDQ_RSS
233     or RTE_ETH_MQ_RX_RSS mode, and SRIOV mode should be activated (max_vfs >= 1).
234     It also needs config VF RSS information like hash function, RSS key, RSS key length.
235
236 .. note::
237
238     The limitation for VF RSS on Intel® 82599 10 Gigabit Ethernet Controller is:
239     The hash and key are shared among PF and all VF, the RETA table with 128 entries is also shared
240     among PF and all VF; So it could not to provide a method to query the hash and reta content per
241     VF on guest, while, if possible, please query them on host for the shared RETA information.
242
243 Virtual Function enumeration is performed in the following sequence by the Linux* pci driver for a dual-port NIC.
244 When you enable the four Virtual Functions with the above command, the four enabled functions have a Function#
245 represented by (Bus#, Device#, Function#) in sequence starting from 0 to 3.
246 However:
247
248 *   Virtual Functions 0 and 2 belong to Physical Function 0
249
250 *   Virtual Functions 1 and 3 belong to Physical Function 1
251
252 .. note::
253
254     The above is an important consideration to take into account when targeting specific packets to a selected port.
255
256 Intel® 82576 Gigabit Ethernet Controller and Intel® Ethernet Controller I350 Family VF Infrastructure
257 ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
258
259 In a virtualized environment, an Intel® 82576 Gigabit Ethernet Controller serves up to eight virtual machines (VMs).
260 The controller has 16 TX and 16 RX queues.
261 They are generally referred to (or thought of) as queue pairs (one TX and one RX queue).
262 This gives the controller 16 queue pairs.
263
264 A pool is a group of queue pairs for assignment to the same VF, used for transmit and receive operations.
265 The controller has eight pools, with each pool containing two queue pairs, that is, two TX and two RX queues assigned to each VF.
266
267 In a virtualized environment, an Intel® Ethernet Controller I350 family device serves up to eight virtual machines (VMs) per port.
268 The eight queues can be accessed by eight different VMs if configured correctly (the i350 has 4x1GbE ports each with 8T X and 8 RX queues),
269 that means, one Transmit and one Receive queue assigned to each VF.
270
271 For example,
272
273 *   Using Linux* igb driver:
274
275     .. code-block:: console
276
277         rmmod igb (To remove the igb module)
278         insmod igb max_vfs=2,2 (To enable two Virtual Functions per port)
279
280 *   Using DPDK PMD PF igb driver:
281
282     Kernel Params: iommu=pt, intel_iommu=on modprobe uio
283
284     .. code-block:: console
285
286         insmod igb_uio
287         ./dpdk-devbind.py -b igb_uio bb:ss.f
288         echo 2 > /sys/bus/pci/devices/0000\:bb\:ss.f/max_vfs (To enable two VFs on a specific pci device)
289
290     Launch DPDK testpmd/example or your own host daemon application using the DPDK PMD library.
291
292 Virtual Function enumeration is performed in the following sequence by the Linux* pci driver for a four-port NIC.
293 When you enable the four Virtual Functions with the above command, the four enabled functions have a Function#
294 represented by (Bus#, Device#, Function#) in sequence, starting from 0 to 7.
295 However:
296
297 *   Virtual Functions 0 and 4 belong to Physical Function 0
298
299 *   Virtual Functions 1 and 5 belong to Physical Function 1
300
301 *   Virtual Functions 2 and 6 belong to Physical Function 2
302
303 *   Virtual Functions 3 and 7 belong to Physical Function 3
304
305 .. note::
306
307     The above is an important consideration to take into account when targeting specific packets to a selected port.
308
309 Validated Hypervisors
310 ~~~~~~~~~~~~~~~~~~~~~
311
312 The validated hypervisor is:
313
314 *   KVM (Kernel Virtual Machine) with  Qemu, version 0.14.0
315
316 However, the hypervisor is bypassed to configure the Virtual Function devices using the Mailbox interface,
317 the solution is hypervisor-agnostic.
318 Xen* and VMware* (when SR- IOV is supported) will also be able to support the DPDK with Virtual Function driver support.
319
320 Expected Guest Operating System in Virtual Machine
321 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
322
323 The expected guest operating systems in a virtualized environment are:
324
325 *   Fedora* 14 (64-bit)
326
327 *   Ubuntu* 10.04 (64-bit)
328
329 For supported kernel versions, refer to the *DPDK Release Notes*.
330
331 .. _intel_vf_kvm:
332
333 Setting Up a KVM Virtual Machine Monitor
334 ----------------------------------------
335
336 The following describes a target environment:
337
338 *   Host Operating System: Fedora 14
339
340 *   Hypervisor: KVM (Kernel Virtual Machine) with Qemu  version 0.14.0
341
342 *   Guest Operating System: Fedora 14
343
344 *   Linux Kernel Version: Refer to the  *DPDK Getting Started Guide*
345
346 *   Target Applications:  l2fwd, l3fwd-vf
347
348 The setup procedure is as follows:
349
350 #.  Before booting the Host OS, open **BIOS setup** and enable **Intel® VT features**.
351
352 #.  While booting the Host OS kernel, pass the intel_iommu=on kernel command line argument using GRUB.
353     When using DPDK PF driver on host, pass the iommu=pt kernel command line argument in GRUB.
354
355 #.  Download qemu-kvm-0.14.0 from
356     `http://sourceforge.net/projects/kvm/files/qemu-kvm/ <http://sourceforge.net/projects/kvm/files/qemu-kvm/>`_
357     and install it in the Host OS using the following steps:
358
359     When using a recent kernel (2.6.25+) with kvm modules included:
360
361     .. code-block:: console
362
363         tar xzf qemu-kvm-release.tar.gz
364         cd qemu-kvm-release
365         ./configure --prefix=/usr/local/kvm
366         make
367         sudo make install
368         sudo /sbin/modprobe kvm-intel
369
370     When using an older kernel, or a kernel from a distribution without the kvm modules,
371     you must download (from the same link), compile and install the modules yourself:
372
373     .. code-block:: console
374
375         tar xjf kvm-kmod-release.tar.bz2
376         cd kvm-kmod-release
377         ./configure
378         make
379         sudo make install
380         sudo /sbin/modprobe kvm-intel
381
382     qemu-kvm installs in the /usr/local/bin directory.
383
384     For more details about KVM configuration and usage, please refer to:
385
386     `http://www.linux-kvm.org/page/HOWTO1 <http://www.linux-kvm.org/page/HOWTO1>`_.
387
388 #.  Create a Virtual Machine and install Fedora 14 on the Virtual Machine.
389     This is referred to as the Guest Operating System (Guest OS).
390
391 #.  Download and install the latest ixgbe driver from
392     `intel.com <https://downloadcenter.intel.com/download/14687>`_.
393
394 #.  In the Host OS
395
396     When using Linux kernel ixgbe driver, unload the Linux ixgbe driver and reload it with the max_vfs=2,2 argument:
397
398     .. code-block:: console
399
400         rmmod ixgbe
401         modprobe ixgbe max_vfs=2,2
402
403     When using DPDK PMD PF driver, insert DPDK kernel module igb_uio and set the number of VF by sysfs max_vfs:
404
405     .. code-block:: console
406
407         modprobe uio
408         insmod igb_uio
409         ./dpdk-devbind.py -b igb_uio 02:00.0 02:00.1 0e:00.0 0e:00.1
410         echo 2 > /sys/bus/pci/devices/0000\:02\:00.0/max_vfs
411         echo 2 > /sys/bus/pci/devices/0000\:02\:00.1/max_vfs
412         echo 2 > /sys/bus/pci/devices/0000\:0e\:00.0/max_vfs
413         echo 2 > /sys/bus/pci/devices/0000\:0e\:00.1/max_vfs
414
415     .. note::
416
417         You need to explicitly specify number of vfs for each port, for example,
418         in the command above, it creates two vfs for the first two ixgbe ports.
419
420     Let say we have a machine with four physical ixgbe ports:
421
422
423         0000:02:00.0
424
425         0000:02:00.1
426
427         0000:0e:00.0
428
429         0000:0e:00.1
430
431     The command above creates two vfs for device 0000:02:00.0:
432
433     .. code-block:: console
434
435         ls -alrt /sys/bus/pci/devices/0000\:02\:00.0/virt*
436         lrwxrwxrwx. 1 root root 0 Apr 13 05:40 /sys/bus/pci/devices/0000:02:00.0/virtfn1 -> ../0000:02:10.2
437         lrwxrwxrwx. 1 root root 0 Apr 13 05:40 /sys/bus/pci/devices/0000:02:00.0/virtfn0 -> ../0000:02:10.0
438
439     It also creates two vfs for device 0000:02:00.1:
440
441     .. code-block:: console
442
443         ls -alrt /sys/bus/pci/devices/0000\:02\:00.1/virt*
444         lrwxrwxrwx. 1 root root 0 Apr 13 05:51 /sys/bus/pci/devices/0000:02:00.1/virtfn1 -> ../0000:02:10.3
445         lrwxrwxrwx. 1 root root 0 Apr 13 05:51 /sys/bus/pci/devices/0000:02:00.1/virtfn0 -> ../0000:02:10.1
446
447 #.  List the PCI devices connected and notice that the Host OS shows two Physical Functions (traditional ports)
448     and four Virtual Functions (two for each port).
449     This is the result of the previous step.
450
451 #.  Insert the pci_stub module to hold the PCI devices that are freed from the default driver using the following command
452     (see http://www.linux-kvm.org/page/How_to_assign_devices_with_VT-d_in_KVM Section 4 for more information):
453
454     .. code-block:: console
455
456         sudo /sbin/modprobe pci-stub
457
458     Unbind the default driver from the PCI devices representing the Virtual Functions.
459     A script to perform this action is as follows:
460
461     .. code-block:: console
462
463         echo "8086 10ed" > /sys/bus/pci/drivers/pci-stub/new_id
464         echo 0000:08:10.0 > /sys/bus/pci/devices/0000:08:10.0/driver/unbind
465         echo 0000:08:10.0 > /sys/bus/pci/drivers/pci-stub/bind
466
467     where, 0000:08:10.0 belongs to the Virtual Function visible in the Host OS.
468
469 #.  Now, start the Virtual Machine by running the following command:
470
471     .. code-block:: console
472
473         /usr/local/kvm/bin/qemu-system-x86_64 -m 4096 -smp 4 -boot c -hda lucid.qcow2 -device pci-assign,host=08:10.0
474
475     where:
476
477         — -m = memory to assign
478
479         — -smp = number of smp cores
480
481         — -boot = boot option
482
483         — -hda = virtual disk image
484
485         — -device = device to attach
486
487     .. note::
488
489         — The pci-assign,host=08:10.0 value indicates that you want to attach a PCI device
490         to a Virtual Machine and the respective (Bus:Device.Function)
491         numbers should be passed for the Virtual Function to be attached.
492
493         — qemu-kvm-0.14.0 allows a maximum of four PCI devices assigned to a VM,
494         but this is qemu-kvm version dependent since qemu-kvm-0.14.1 allows a maximum of five PCI devices.
495
496         — qemu-system-x86_64 also has a -cpu command line option that is used to select the cpu_model
497         to emulate in a Virtual Machine. Therefore, it can be used as:
498
499         .. code-block:: console
500
501             /usr/local/kvm/bin/qemu-system-x86_64 -cpu ?
502
503             (to list all available cpu_models)
504
505             /usr/local/kvm/bin/qemu-system-x86_64 -m 4096 -cpu host -smp 4 -boot c -hda lucid.qcow2 -device pci-assign,host=08:10.0
506
507             (to use the same cpu_model equivalent to the host cpu)
508
509         For more information, please refer to: `http://wiki.qemu.org/Features/CPUModels <http://wiki.qemu.org/Features/CPUModels>`_.
510
511 #.  If use vfio-pci to pass through device instead of pci-assign, steps 8 and 9 need to be updated to bind device to vfio-pci and
512     replace pci-assign with vfio-pci when start virtual machine.
513
514     .. code-block:: console
515
516         sudo /sbin/modprobe vfio-pci
517
518         echo "8086 10ed" > /sys/bus/pci/drivers/vfio-pci/new_id
519         echo 0000:08:10.0 > /sys/bus/pci/devices/0000:08:10.0/driver/unbind
520         echo 0000:08:10.0 > /sys/bus/pci/drivers/vfio-pci/bind
521
522         /usr/local/kvm/bin/qemu-system-x86_64 -m 4096 -smp 4 -boot c -hda lucid.qcow2 -device vfio-pci,host=08:10.0
523
524 #.  Install and run DPDK host app to take  over the Physical Function. Eg.
525
526     .. code-block:: console
527
528         ./<build_dir>/app/dpdk-testpmd -l 0-3 -n 4 -- -i
529
530 #.  Finally, access the Guest OS using vncviewer with the localhost:5900 port and check the lspci command output in the Guest OS.
531     The virtual functions will be listed as available for use.
532
533 #.  Configure and install the DPDK on the Guest OS as normal, that is, there is no change to the normal installation procedure.
534
535 .. note::
536
537     If you are unable to compile the DPDK and you are getting "error: CPU you selected does not support x86-64 instruction set",
538     power off the Guest OS and start the virtual machine with the correct -cpu option in the qemu- system-x86_64 command as shown in step 9.
539     You must select the best x86_64 cpu_model to emulate or you can select host option if available.
540
541 .. note::
542
543     Run the DPDK l2fwd sample application in the Guest OS with Hugepages enabled.
544     For the expected benchmark performance, you must pin the cores from the Guest OS to the Host OS (taskset can be used to do this) and
545     you must also look at the PCI Bus layout on the board to ensure you are not running the traffic over the QPI Interface.
546
547 .. note::
548
549     *   The Virtual Machine Manager (the Fedora package name is virt-manager) is a utility for virtual machine management
550         that can also be used to create, start, stop and delete virtual machines.
551         If this option is used, step 2 and 6 in the instructions provided will be different.
552
553     *   virsh, a command line utility for virtual machine management,
554         can also be used to bind and unbind devices to a virtual machine in Ubuntu.
555         If this option is used, step 6 in the instructions provided will be different.
556
557     *   The Virtual Machine Monitor (see :numref:`figure_perf_benchmark`) is equivalent to a Host OS with KVM installed as described in the instructions.
558
559 .. _figure_perf_benchmark:
560
561 .. figure:: img/perf_benchmark.*
562
563    Performance Benchmark Setup
564
565
566 DPDK SR-IOV PMD PF/VF Driver Usage Model
567 ----------------------------------------
568
569 Fast Host-based Packet Processing
570 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
571
572 Software Defined Network (SDN) trends are demanding fast host-based packet handling.
573 In a virtualization environment,
574 the DPDK VF PMD performs the same throughput result as a non-VT native environment.
575
576 With such host instance fast packet processing, lots of services such as filtering, QoS,
577 DPI can be offloaded on the host fast path.
578
579 :numref:`figure_fast_pkt_proc` shows the scenario where some VMs directly communicate externally via a VFs,
580 while others connect to a virtual switch and share the same uplink bandwidth.
581
582 .. _figure_fast_pkt_proc:
583
584 .. figure:: img/fast_pkt_proc.*
585
586    Fast Host-based Packet Processing
587
588
589 SR-IOV (PF/VF) Approach for Inter-VM Communication
590 --------------------------------------------------
591
592 Inter-VM data communication is one of the traffic bottle necks in virtualization platforms.
593 SR-IOV device assignment helps a VM to attach the real device, taking advantage of the bridge in the NIC.
594 So VF-to-VF traffic within the same physical port (VM0<->VM1) have hardware acceleration.
595 However, when VF crosses physical ports (VM0<->VM2), there is no such hardware bridge.
596 In this case, the DPDK PMD PF driver provides host forwarding between such VMs.
597
598 :numref:`figure_inter_vm_comms` shows an example.
599 In this case an update of the MAC address lookup tables in both the NIC and host DPDK application is required.
600
601 In the NIC, writing the destination of a MAC address belongs to another cross device VM to the PF specific pool.
602 So when a packet comes in, its destination MAC address will match and forward to the host DPDK PMD application.
603
604 In the host DPDK application, the behavior is similar to L2 forwarding,
605 that is, the packet is forwarded to the correct PF pool.
606 The SR-IOV NIC switch forwards the packet to a specific VM according to the MAC destination address
607 which belongs to the destination VF on the VM.
608
609 .. _figure_inter_vm_comms:
610
611 .. figure:: img/inter_vm_comms.*
612
613    Inter-VM Communication
614
615
616 Windows Support
617 ---------------
618
619 *   IAVF PMD currently is supported only inside Windows guest created on Linux host.
620
621 *   Physical PCI resources are exposed as virtual functions
622     into Windows VM using SR-IOV pass-through feature.
623
624 *   Create a Windows guest on Linux host using KVM hypervisor.
625     Refer to the steps mentioned in the above section: :ref:`intel_vf_kvm`.
626
627 *   In the Host machine, download and install the kernel Ethernet driver
628     for `i40e <https://downloadcenter.intel.com/download/24411>`_
629     or `ice <https://downloadcenter.intel.com/download/29746>`_.
630
631 *   For Windows guest, install NetUIO driver
632     in place of existing built-in (inbox) Virtual Function driver.
633
634 *   To load NetUIO driver, follow the steps mentioned in `dpdk-kmods repository
635     <https://git.dpdk.org/dpdk-kmods/tree/windows/netuio/README.rst>`_.
636
637
638 Inline IPsec Support
639 --------------------
640
641 *   IAVF PMD supports inline crypto processing depending on the underlying
642     hardware crypto capabilities. IPsec Security Gateway Sample Application
643     supports inline IPsec processing for IAVF PMD. For more details see the
644     IPsec Security Gateway Sample Application and Security library
645     documentation.