doc: update mlx4 documentation
[dpdk.git] / doc / guides / nics / mlx4.rst
1 ..  BSD LICENSE
2     Copyright 2012 6WIND S.A.
3     Copyright 2015 Mellanox
4
5     Redistribution and use in source and binary forms, with or without
6     modification, are permitted provided that the following conditions
7     are met:
8
9     * Redistributions of source code must retain the above copyright
10     notice, this list of conditions and the following disclaimer.
11     * Redistributions in binary form must reproduce the above copyright
12     notice, this list of conditions and the following disclaimer in
13     the documentation and/or other materials provided with the
14     distribution.
15     * Neither the name of 6WIND S.A. nor the names of its
16     contributors may be used to endorse or promote products derived
17     from this software without specific prior written permission.
18
19     THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
20     "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
21     LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
22     A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
23     OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
24     SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
25     LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
26     DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
27     THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
28     (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
29     OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
30
31 MLX4 poll mode driver library
32 =============================
33
34 The MLX4 poll mode driver library (**librte_pmd_mlx4**) implements support
35 for **Mellanox ConnectX-3** and **Mellanox ConnectX-3 Pro** 10/40 Gbps adapters
36 as well as their virtual functions (VF) in SR-IOV context.
37
38 Information and documentation about this family of adapters can be found on
39 the `Mellanox website <http://www.mellanox.com>`_. Help is also provided by
40 the `Mellanox community <http://community.mellanox.com/welcome>`_.
41
42 There is also a `section dedicated to this poll mode driver
43 <http://www.mellanox.com/page/products_dyn?product_family=209&mtag=pmd_for_dpdk>`_.
44
45 .. note::
46
47    Due to external dependencies, this driver is disabled by default. It must
48    be enabled manually by setting ``CONFIG_RTE_LIBRTE_MLX4_PMD=y`` and
49    recompiling DPDK.
50
51 Implementation details
52 ----------------------
53
54 Most Mellanox ConnectX-3 devices provide two ports but expose a single PCI
55 bus address, thus unlike most drivers, librte_pmd_mlx4 registers itself as a
56 PCI driver that allocates one Ethernet device per detected port.
57
58 For this reason, one cannot white/blacklist a single port without also
59 white/blacklisting the others on the same device.
60
61 Besides its dependency on libibverbs (that implies libmlx4 and associated
62 kernel support), librte_pmd_mlx4 relies heavily on system calls for control
63 operations such as querying/updating the MTU and flow control parameters.
64
65 For security reasons and robustness, this driver only deals with virtual
66 memory addresses. The way resources allocations are handled by the kernel
67 combined with hardware specifications that allow it to handle virtual memory
68 addresses directly ensure that DPDK applications cannot access random
69 physical memory (or memory that does not belong to the current process).
70
71 This capability allows the PMD to coexist with kernel network interfaces
72 which remain functional, although they stop receiving unicast packets as
73 long as they share the same MAC address.
74
75 Compiling librte_pmd_mlx4 causes DPDK to be linked against libibverbs.
76
77 Configuration
78 -------------
79
80 Compilation options
81 ~~~~~~~~~~~~~~~~~~~
82
83 These options can be modified in the ``.config`` file.
84
85 - ``CONFIG_RTE_LIBRTE_MLX4_PMD`` (default **n**)
86
87   Toggle compilation of librte_pmd_mlx4 itself.
88
89 - ``CONFIG_RTE_LIBRTE_MLX4_DEBUG`` (default **n**)
90
91   Toggle debugging code and stricter compilation flags. Enabling this option
92   adds additional run-time checks and debugging messages at the cost of
93   lower performance.
94
95 - ``CONFIG_RTE_LIBRTE_MLX4_DEBUG_BROKEN_VERBS`` (default **n**)
96
97   Mellanox OFED versions earlier than 4.2 may return false errors from
98   Verbs object destruction APIs after the device is plugged out.
99   Enabling this option replaces assertion checks that cause the program
100   to abort with harmless debugging messages as a workaround.
101   Relevant only when CONFIG_RTE_LIBRTE_MLX4_DEBUG is enabled.
102
103 - ``CONFIG_RTE_LIBRTE_MLX4_TX_MP_CACHE`` (default **8**)
104
105   Maximum number of cached memory pools (MPs) per TX queue. Each MP from
106   which buffers are to be transmitted must be associated to memory regions
107   (MRs). This is a slow operation that must be cached.
108
109   This value is always 1 for RX queues since they use a single MP.
110
111 Run-time configuration
112 ~~~~~~~~~~~~~~~~~~~~~~
113
114 - librte_pmd_mlx4 brings kernel network interfaces up during initialization
115   because it is affected by their state. Forcing them down prevents packets
116   reception.
117
118 - **ethtool** operations on related kernel interfaces also affect the PMD.
119
120 - ``port`` parameter [int]
121
122   This parameter provides a physical port to probe and can be specified multiple
123   times for additional ports. All ports are probed by default if left
124   unspecified.
125
126 Kernel module parameters
127 ~~~~~~~~~~~~~~~~~~~~~~~~
128
129 The **mlx4_core** kernel module has several parameters that affect the
130 behavior and/or the performance of librte_pmd_mlx4. Some of them are described
131 below.
132
133 - **num_vfs** (integer or triplet, optionally prefixed by device address
134   strings)
135
136   Create the given number of VFs on the specified devices.
137
138 - **log_num_mgm_entry_size** (integer)
139
140   Device-managed flow steering (DMFS) is required by DPDK applications. It is
141   enabled by using a negative value, the last four bits of which have a
142   special meaning.
143
144   - **-1**: force device-managed flow steering (DMFS).
145   - **-7**: configure optimized steering mode to improve performance with the
146     following limitation: VLAN filtering is not supported with this mode.
147     This is the recommended mode in case VLAN filter is not needed.
148
149 Prerequisites
150 -------------
151
152 This driver relies on external libraries and kernel drivers for resources
153 allocations and initialization. The following dependencies are not part of
154 DPDK and must be installed separately:
155
156 - **libibverbs** (provided by rdma-core package)
157
158   User space verbs framework used by librte_pmd_mlx4. This library provides
159   a generic interface between the kernel and low-level user space drivers
160   such as libmlx4.
161
162   It allows slow and privileged operations (context initialization, hardware
163   resources allocations) to be managed by the kernel and fast operations to
164   never leave user space.
165
166 - **libmlx4** (provided by rdma-core package)
167
168   Low-level user space driver library for Mellanox ConnectX-3 devices,
169   it is automatically loaded by libibverbs.
170
171   This library basically implements send/receive calls to the hardware
172   queues.
173
174 - **Kernel modules**
175
176   They provide the kernel-side verbs API and low level device drivers that
177   manage actual hardware initialization and resources sharing with user
178   space processes.
179
180   Unlike most other PMDs, these modules must remain loaded and bound to
181   their devices:
182
183   - mlx4_core: hardware driver managing Mellanox ConnectX-3 devices.
184   - mlx4_en: Ethernet device driver that provides kernel network interfaces.
185   - mlx4_ib: InifiniBand device driver.
186   - ib_uverbs: user space driver for verbs (entry point for libibverbs).
187
188 - **Firmware update**
189
190   Mellanox OFED releases include firmware updates for ConnectX-3 adapters.
191
192   Because each release provides new features, these updates must be applied to
193   match the kernel modules and libraries they come with.
194
195 .. note::
196
197    Both libraries are BSD and GPL licensed. Linux kernel modules are GPL
198    licensed.
199
200 Depending on system constraints and user preferences either RDMA core library
201 with a recent enough Linux kernel release (recommended) or Mellanox OFED,
202 which provides compatibility with older releases.
203
204 Current RDMA core package and Linux kernel (recommended)
205 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
206
207 - Minimal Linux kernel version: 4.14.
208 - Minimal RDMA core version: v15 (see `RDMA core installation documentation`_).
209
210 .. _`RDMA core installation documentation`: https://raw.githubusercontent.com/linux-rdma/rdma-core/master/README.md
211
212 .. _Mellanox_OFED_as_a_fallback:
213
214 Mellanox OFED as a fallback
215 ~~~~~~~~~~~~~~~~~~~~~~~~~~~
216
217 - `Mellanox OFED`_ version: **4.2**.
218 - firmware version: **2.42.5000** and above.
219
220 .. _`Mellanox OFED`: http://www.mellanox.com/page/products_dyn?product_family=26&mtag=linux_sw_drivers
221
222 .. note::
223
224    Several versions of Mellanox OFED are available. Installing the version
225    this DPDK release was developed and tested against is strongly
226    recommended. Please check the `prerequisites`_.
227
228 Installing Mellanox OFED
229 ^^^^^^^^^^^^^^^^^^^^^^^^
230
231 1. Download latest Mellanox OFED.
232
233 2. Install the required libraries and kernel modules either by installing
234    only the required set, or by installing the entire Mellanox OFED:
235
236    For bare metal use:
237
238    .. code-block:: console
239
240         ./mlnxofedinstall --dpdk --upstream-libs
241
242    For SR-IOV hypervisors use:
243
244    .. code-block:: console
245
246         ./mlnxofedinstall --dpdk --upstream-libs --enable-sriov --hypervisor
247
248    For SR-IOV virtual machine use:
249
250    .. code-block:: console
251
252         ./mlnxofedinstall --dpdk --upstream-libs --guest
253
254 3. Verify the firmware is the correct one:
255
256    .. code-block:: console
257
258         ibv_devinfo
259
260 4. Set all ports links to Ethernet, follow instructions on the screen:
261
262    .. code-block:: console
263
264         connectx_port_config
265
266 5. Continue with :ref:`section 2 of the Quick Start Guide <QSG_2>`.
267
268 Supported NICs
269 --------------
270
271 * Mellanox(R) ConnectX(R)-3 Pro 40G MCX354A-FCC_Ax (2*40G)
272
273 .. _qsg:
274
275 Quick Start Guide
276 -----------------
277
278 1. Set all ports links to Ethernet
279
280    .. code-block:: console
281
282         PCI=<NIC PCI address>
283         echo eth > "/sys/bus/pci/devices/$PCI/mlx4_port0"
284         echo eth > "/sys/bus/pci/devices/$PCI/mlx4_port1"
285
286    .. note::
287
288         If using Mellanox OFED one can permanently set the port link
289         to Ethernet using connectx_port_config tool provided by it.
290         :ref:`Mellanox_OFED_as_a_fallback`:
291
292 .. _QSG_2:
293
294 2. In case of bare metal or hypervisor, configure optimized steering mode
295    by adding the following line to ``/etc/modprobe.d/mlx4_core.conf``:
296
297    .. code-block:: console
298
299         options mlx4_core log_num_mgm_entry_size=-7
300
301    .. note::
302
303         If VLAN filtering is used, set log_num_mgm_entry_size=-1.
304         Performance degradation can occur on this case.
305
306 3. Restart the driver:
307
308    .. code-block:: console
309
310         /etc/init.d/openibd restart
311
312    or:
313
314    .. code-block:: console
315
316         service openibd restart
317
318 4. Compile DPDK and you are ready to go. See instructions on
319    :ref:`Development Kit Build System <Development_Kit_Build_System>`
320
321 Performance tuning
322 ------------------
323
324 1. Verify the optimized steering mode is configured:
325
326   .. code-block:: console
327
328         cat /sys/module/mlx4_core/parameters/log_num_mgm_entry_size
329
330 2. Use the CPU near local NUMA node to which the PCIe adapter is connected,
331    for better performance. For VMs, verify that the right CPU
332    and NUMA node are pinned according to the above. Run:
333
334    .. code-block:: console
335
336         lstopo-no-graphics
337
338    to identify the NUMA node to which the PCIe adapter is connected.
339
340 3. If more than one adapter is used, and root complex capabilities allow
341    to put both adapters on the same NUMA node without PCI bandwidth degradation,
342    it is recommended to locate both adapters on the same NUMA node.
343    This in order to forward packets from one to the other without
344    NUMA performance penalty.
345
346 4. Disable pause frames:
347
348    .. code-block:: console
349
350         ethtool -A <netdev> rx off tx off
351
352 5. Verify IO non-posted prefetch is disabled by default. This can be checked
353    via the BIOS configuration. Please contact you server provider for more
354    information about the settings.
355
356 .. note::
357
358         On some machines, depends on the machine integrator, it is beneficial
359         to set the PCI max read request parameter to 1K. This can be
360         done in the following way:
361
362         To query the read request size use:
363
364         .. code-block:: console
365
366                 setpci -s <NIC PCI address> 68.w
367
368         If the output is different than 3XXX, set it by:
369
370         .. code-block:: console
371
372                 setpci -s <NIC PCI address> 68.w=3XXX
373
374         The XXX can be different on different systems. Make sure to configure
375         according to the setpci output.
376
377 Usage example
378 -------------
379
380 This section demonstrates how to launch **testpmd** with Mellanox ConnectX-3
381 devices managed by librte_pmd_mlx4.
382
383 #. Load the kernel modules:
384
385    .. code-block:: console
386
387       modprobe -a ib_uverbs mlx4_en mlx4_core mlx4_ib
388
389    Alternatively if MLNX_OFED is fully installed, the following script can
390    be run:
391
392    .. code-block:: console
393
394       /etc/init.d/openibd restart
395
396    .. note::
397
398       User space I/O kernel modules (uio and igb_uio) are not used and do
399       not have to be loaded.
400
401 #. Make sure Ethernet interfaces are in working order and linked to kernel
402    verbs. Related sysfs entries should be present:
403
404    .. code-block:: console
405
406       ls -d /sys/class/net/*/device/infiniband_verbs/uverbs* | cut -d / -f 5
407
408    Example output:
409
410    .. code-block:: console
411
412       eth2
413       eth3
414       eth4
415       eth5
416
417 #. Optionally, retrieve their PCI bus addresses for whitelisting:
418
419    .. code-block:: console
420
421       {
422           for intf in eth2 eth3 eth4 eth5;
423           do
424               (cd "/sys/class/net/${intf}/device/" && pwd -P);
425           done;
426       } |
427       sed -n 's,.*/\(.*\),-w \1,p'
428
429    Example output:
430
431    .. code-block:: console
432
433       -w 0000:83:00.0
434       -w 0000:83:00.0
435       -w 0000:84:00.0
436       -w 0000:84:00.0
437
438    .. note::
439
440       There are only two distinct PCI bus addresses because the Mellanox
441       ConnectX-3 adapters installed on this system are dual port.
442
443 #. Request huge pages:
444
445    .. code-block:: console
446
447       echo 1024 > /sys/kernel/mm/hugepages/hugepages-2048kB/nr_hugepages/nr_hugepages
448
449 #. Start testpmd with basic parameters:
450
451    .. code-block:: console
452
453       testpmd -l 8-15 -n 4 -w 0000:83:00.0 -w 0000:84:00.0 -- --rxq=2 --txq=2 -i
454
455    Example output:
456
457    .. code-block:: console
458
459       [...]
460       EAL: PCI device 0000:83:00.0 on NUMA socket 1
461       EAL:   probe driver: 15b3:1007 librte_pmd_mlx4
462       PMD: librte_pmd_mlx4: PCI information matches, using device "mlx4_0" (VF: false)
463       PMD: librte_pmd_mlx4: 2 port(s) detected
464       PMD: librte_pmd_mlx4: port 1 MAC address is 00:02:c9:b5:b7:50
465       PMD: librte_pmd_mlx4: port 2 MAC address is 00:02:c9:b5:b7:51
466       EAL: PCI device 0000:84:00.0 on NUMA socket 1
467       EAL:   probe driver: 15b3:1007 librte_pmd_mlx4
468       PMD: librte_pmd_mlx4: PCI information matches, using device "mlx4_1" (VF: false)
469       PMD: librte_pmd_mlx4: 2 port(s) detected
470       PMD: librte_pmd_mlx4: port 1 MAC address is 00:02:c9:b5:ba:b0
471       PMD: librte_pmd_mlx4: port 2 MAC address is 00:02:c9:b5:ba:b1
472       Interactive-mode selected
473       Configuring Port 0 (socket 0)
474       PMD: librte_pmd_mlx4: 0x867d60: TX queues number update: 0 -> 2
475       PMD: librte_pmd_mlx4: 0x867d60: RX queues number update: 0 -> 2
476       Port 0: 00:02:C9:B5:B7:50
477       Configuring Port 1 (socket 0)
478       PMD: librte_pmd_mlx4: 0x867da0: TX queues number update: 0 -> 2
479       PMD: librte_pmd_mlx4: 0x867da0: RX queues number update: 0 -> 2
480       Port 1: 00:02:C9:B5:B7:51
481       Configuring Port 2 (socket 0)
482       PMD: librte_pmd_mlx4: 0x867de0: TX queues number update: 0 -> 2
483       PMD: librte_pmd_mlx4: 0x867de0: RX queues number update: 0 -> 2
484       Port 2: 00:02:C9:B5:BA:B0
485       Configuring Port 3 (socket 0)
486       PMD: librte_pmd_mlx4: 0x867e20: TX queues number update: 0 -> 2
487       PMD: librte_pmd_mlx4: 0x867e20: RX queues number update: 0 -> 2
488       Port 3: 00:02:C9:B5:BA:B1
489       Checking link statuses...
490       Port 0 Link Up - speed 10000 Mbps - full-duplex
491       Port 1 Link Up - speed 40000 Mbps - full-duplex
492       Port 2 Link Up - speed 10000 Mbps - full-duplex
493       Port 3 Link Up - speed 40000 Mbps - full-duplex
494       Done
495       testpmd>