net/mlx4: remove soft counters compilation option
[dpdk.git] / doc / guides / nics / mlx4.rst
1 ..  BSD LICENSE
2     Copyright 2012 6WIND S.A.
3     Copyright 2015 Mellanox
4
5     Redistribution and use in source and binary forms, with or without
6     modification, are permitted provided that the following conditions
7     are met:
8
9     * Redistributions of source code must retain the above copyright
10     notice, this list of conditions and the following disclaimer.
11     * Redistributions in binary form must reproduce the above copyright
12     notice, this list of conditions and the following disclaimer in
13     the documentation and/or other materials provided with the
14     distribution.
15     * Neither the name of 6WIND S.A. nor the names of its
16     contributors may be used to endorse or promote products derived
17     from this software without specific prior written permission.
18
19     THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
20     "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
21     LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
22     A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
23     OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
24     SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
25     LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
26     DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
27     THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
28     (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
29     OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
30
31 MLX4 poll mode driver library
32 =============================
33
34 The MLX4 poll mode driver library (**librte_pmd_mlx4**) implements support
35 for **Mellanox ConnectX-3** and **Mellanox ConnectX-3 Pro** 10/40 Gbps adapters
36 as well as their virtual functions (VF) in SR-IOV context.
37
38 Information and documentation about this family of adapters can be found on
39 the `Mellanox website <http://www.mellanox.com>`_. Help is also provided by
40 the `Mellanox community <http://community.mellanox.com/welcome>`_.
41
42 There is also a `section dedicated to this poll mode driver
43 <http://www.mellanox.com/page/products_dyn?product_family=209&mtag=pmd_for_dpdk>`_.
44
45 .. note::
46
47    Due to external dependencies, this driver is disabled by default. It must
48    be enabled manually by setting ``CONFIG_RTE_LIBRTE_MLX4_PMD=y`` and
49    recompiling DPDK.
50
51 Implementation details
52 ----------------------
53
54 Most Mellanox ConnectX-3 devices provide two ports but expose a single PCI
55 bus address, thus unlike most drivers, librte_pmd_mlx4 registers itself as a
56 PCI driver that allocates one Ethernet device per detected port.
57
58 For this reason, one cannot white/blacklist a single port without also
59 white/blacklisting the others on the same device.
60
61 Besides its dependency on libibverbs (that implies libmlx4 and associated
62 kernel support), librte_pmd_mlx4 relies heavily on system calls for control
63 operations such as querying/updating the MTU and flow control parameters.
64
65 For security reasons and robustness, this driver only deals with virtual
66 memory addresses. The way resources allocations are handled by the kernel
67 combined with hardware specifications that allow it to handle virtual memory
68 addresses directly ensure that DPDK applications cannot access random
69 physical memory (or memory that does not belong to the current process).
70
71 This capability allows the PMD to coexist with kernel network interfaces
72 which remain functional, although they stop receiving unicast packets as
73 long as they share the same MAC address.
74
75 Compiling librte_pmd_mlx4 causes DPDK to be linked against libibverbs.
76
77 Features
78 --------
79
80 - Multi arch support: x86_64 and POWER8.
81 - RSS, also known as RCA, is supported. In this mode the number of
82   configured RX queues must be a power of two.
83 - VLAN filtering is supported.
84 - Link state information is provided.
85 - Promiscuous mode is supported.
86 - All multicast mode is supported.
87 - Multiple MAC addresses (unicast, multicast) can be configured.
88 - Scattered packets are supported for TX and RX.
89 - Inner L3/L4 (IP, TCP and UDP) TX/RX checksum offloading and validation.
90 - Outer L3 (IP) TX/RX checksum offloading and validation for VXLAN frames.
91 - RX interrupts.
92
93 Limitations
94 -----------
95
96 - RSS hash key cannot be modified.
97 - RSS RETA cannot be configured
98 - RSS always includes L3 (IPv4/IPv6) and L4 (UDP/TCP). They cannot be
99   dissociated.
100
101 Configuration
102 -------------
103
104 Compilation options
105 ~~~~~~~~~~~~~~~~~~~
106
107 These options can be modified in the ``.config`` file.
108
109 - ``CONFIG_RTE_LIBRTE_MLX4_PMD`` (default **n**)
110
111   Toggle compilation of librte_pmd_mlx4 itself.
112
113 - ``CONFIG_RTE_LIBRTE_MLX4_DEBUG`` (default **n**)
114
115   Toggle debugging code and stricter compilation flags. Enabling this option
116   adds additional run-time checks and debugging messages at the cost of
117   lower performance.
118
119 - ``CONFIG_RTE_LIBRTE_MLX4_DEBUG_BROKEN_VERBS`` (default **n**)
120
121   Mellanox OFED versions earlier than 4.2 may return false errors from
122   Verbs object destruction APIs after the device is plugged out.
123   Enabling this option replaces assertion checks that cause the program
124   to abort with harmless debugging messages as a workaround.
125   Relevant only when CONFIG_RTE_LIBRTE_MLX4_DEBUG is enabled.
126
127 - ``CONFIG_RTE_LIBRTE_MLX4_SGE_WR_N`` (default **4**)
128
129   Number of scatter/gather elements (SGEs) per work request (WR). Lowering
130   this number improves performance but also limits the ability to receive
131   scattered packets (packets that do not fit a single mbuf). The default
132   value is a safe tradeoff.
133
134 - ``CONFIG_RTE_LIBRTE_MLX4_MAX_INLINE`` (default **0**)
135
136   Amount of data to be inlined during TX operations. Improves latency but
137   lowers throughput.
138
139 - ``CONFIG_RTE_LIBRTE_MLX4_TX_MP_CACHE`` (default **8**)
140
141   Maximum number of cached memory pools (MPs) per TX queue. Each MP from
142   which buffers are to be transmitted must be associated to memory regions
143   (MRs). This is a slow operation that must be cached.
144
145   This value is always 1 for RX queues since they use a single MP.
146
147 Environment variables
148 ~~~~~~~~~~~~~~~~~~~~~
149
150 - ``MLX4_INLINE_RECV_SIZE``
151
152   A nonzero value enables inline receive for packets up to that size. May
153   significantly improve performance in some cases but lower it in
154   others. Requires careful testing.
155
156 Run-time configuration
157 ~~~~~~~~~~~~~~~~~~~~~~
158
159 - The only constraint when RSS mode is requested is to make sure the number
160   of RX queues is a power of two. This is a hardware requirement.
161
162 - librte_pmd_mlx4 brings kernel network interfaces up during initialization
163   because it is affected by their state. Forcing them down prevents packets
164   reception.
165
166 - **ethtool** operations on related kernel interfaces also affect the PMD.
167
168 - ``port`` parameter [int]
169
170   This parameter provides a physical port to probe and can be specified multiple
171   times for additional ports. All ports are probed by default if left
172   unspecified.
173
174 Kernel module parameters
175 ~~~~~~~~~~~~~~~~~~~~~~~~
176
177 The **mlx4_core** kernel module has several parameters that affect the
178 behavior and/or the performance of librte_pmd_mlx4. Some of them are described
179 below.
180
181 - **num_vfs** (integer or triplet, optionally prefixed by device address
182   strings)
183
184   Create the given number of VFs on the specified devices.
185
186 - **log_num_mgm_entry_size** (integer)
187
188   Device-managed flow steering (DMFS) is required by DPDK applications. It is
189   enabled by using a negative value, the last four bits of which have a
190   special meaning.
191
192   - **-1**: force device-managed flow steering (DMFS).
193   - **-7**: configure optimized steering mode to improve performance with the
194     following limitation: VLAN filtering is not supported with this mode.
195     This is the recommended mode in case VLAN filter is not needed.
196
197 Prerequisites
198 -------------
199
200 This driver relies on external libraries and kernel drivers for resources
201 allocations and initialization. The following dependencies are not part of
202 DPDK and must be installed separately:
203
204 - **libibverbs**
205
206   User space verbs framework used by librte_pmd_mlx4. This library provides
207   a generic interface between the kernel and low-level user space drivers
208   such as libmlx4.
209
210   It allows slow and privileged operations (context initialization, hardware
211   resources allocations) to be managed by the kernel and fast operations to
212   never leave user space.
213
214 - **libmlx4**
215
216   Low-level user space driver library for Mellanox ConnectX-3 devices,
217   it is automatically loaded by libibverbs.
218
219   This library basically implements send/receive calls to the hardware
220   queues.
221
222 - **Kernel modules** (mlnx-ofed-kernel)
223
224   They provide the kernel-side verbs API and low level device drivers that
225   manage actual hardware initialization and resources sharing with user
226   space processes.
227
228   Unlike most other PMDs, these modules must remain loaded and bound to
229   their devices:
230
231   - mlx4_core: hardware driver managing Mellanox ConnectX-3 devices.
232   - mlx4_en: Ethernet device driver that provides kernel network interfaces.
233   - mlx4_ib: InifiniBand device driver.
234   - ib_uverbs: user space driver for verbs (entry point for libibverbs).
235
236 - **Firmware update**
237
238   Mellanox OFED releases include firmware updates for ConnectX-3 adapters.
239
240   Because each release provides new features, these updates must be applied to
241   match the kernel modules and libraries they come with.
242
243 .. note::
244
245    Both libraries are BSD and GPL licensed. Linux kernel modules are GPL
246    licensed.
247
248 Currently supported by DPDK:
249
250 - Mellanox OFED **4.1**.
251 - Firmware version **2.36.5000** and above.
252
253 Getting Mellanox OFED
254 ~~~~~~~~~~~~~~~~~~~~~
255
256 While these libraries and kernel modules are available on OpenFabrics
257 Alliance's `website <https://www.openfabrics.org/>`_ and provided by package
258 managers on most distributions, this PMD requires Ethernet extensions that
259 may not be supported at the moment (this is a work in progress).
260
261 `Mellanox OFED
262 <http://www.mellanox.com/page/products_dyn?product_family=26&mtag=linux_sw_drivers>`_
263 includes the necessary support and should be used in the meantime. For DPDK,
264 only libibverbs, libmlx4, mlnx-ofed-kernel packages and firmware updates are
265 required from that distribution.
266
267 .. note::
268
269    Several versions of Mellanox OFED are available. Installing the version
270    this DPDK release was developed and tested against is strongly
271    recommended. Please check the `prerequisites`_.
272
273 Supported NICs
274 --------------
275
276 * Mellanox(R) ConnectX(R)-3 Pro 40G MCX354A-FCC_Ax (2*40G)
277
278 Quick Start Guide
279 -----------------
280
281 1. Download latest Mellanox OFED. For more info check the  `prerequisites`_.
282
283 2. Install the required libraries and kernel modules either by installing
284    only the required set, or by installing the entire Mellanox OFED:
285
286    For bare metal use:
287
288    .. code-block:: console
289
290         ./mlnxofedinstall
291
292    For SR-IOV hypervisors use:
293
294    .. code-block:: console
295
296         ./mlnxofedinstall --enable-sriov -hypervisor
297
298    For SR-IOV virtual machine use:
299
300    .. code-block:: console
301
302         ./mlnxofedinstall --guest
303
304 3. Verify the firmware is the correct one:
305
306    .. code-block:: console
307
308         ibv_devinfo
309
310 4. Set all ports links to Ethernet, follow instructions on the screen:
311
312    .. code-block:: console
313
314         connectx_port_config
315
316    Or in the manual way:
317
318    .. code-block:: console
319
320         PCI=<NIC PCI address>
321         echo eth > "/sys/bus/pci/devices/$PCI/mlx4_port0"
322         echo eth > "/sys/bus/pci/devices/$PCI/mlx4_port1"
323
324 5. In case of bare metal or hypervisor, configure optimized steering mode
325    by adding the following line to ``/etc/modprobe.d/mlx4_core.conf``:
326
327    .. code-block:: console
328
329         options mlx4_core log_num_mgm_entry_size=-7
330
331    .. note::
332
333         If VLAN filtering is used, set log_num_mgm_entry_size=-1.
334         Performance degradation can occur on this case.
335
336 6. Restart the driver:
337
338    .. code-block:: console
339
340         /etc/init.d/openibd restart
341
342    or:
343
344    .. code-block:: console
345
346         service openibd restart
347
348 7. Compile DPDK and you are ready to go. See instructions on
349    :ref:`Development Kit Build System <Development_Kit_Build_System>`
350
351 Performance tuning
352 ------------------
353
354 1. Verify the optimized steering mode is configured:
355
356   .. code-block:: console
357
358         cat /sys/module/mlx4_core/parameters/log_num_mgm_entry_size
359
360 2. Use environment variable MLX4_INLINE_RECV_SIZE=64 to get maximum
361    performance for 64B messages.
362
363 3. Use the CPU near local NUMA node to which the PCIe adapter is connected,
364    for better performance. For VMs, verify that the right CPU
365    and NUMA node are pinned according to the above. Run:
366
367    .. code-block:: console
368
369         lstopo-no-graphics
370
371    to identify the NUMA node to which the PCIe adapter is connected.
372
373 4. If more than one adapter is used, and root complex capabilities allow
374    to put both adapters on the same NUMA node without PCI bandwidth degradation,
375    it is recommended to locate both adapters on the same NUMA node.
376    This in order to forward packets from one to the other without
377    NUMA performance penalty.
378
379 5. Disable pause frames:
380
381    .. code-block:: console
382
383         ethtool -A <netdev> rx off tx off
384
385 6. Verify IO non-posted prefetch is disabled by default. This can be checked
386    via the BIOS configuration. Please contact you server provider for more
387    information about the settings.
388
389 .. note::
390
391         On some machines, depends on the machine integrator, it is beneficial
392         to set the PCI max read request parameter to 1K. This can be
393         done in the following way:
394
395         To query the read request size use:
396
397         .. code-block:: console
398
399                 setpci -s <NIC PCI address> 68.w
400
401         If the output is different than 3XXX, set it by:
402
403         .. code-block:: console
404
405                 setpci -s <NIC PCI address> 68.w=3XXX
406
407         The XXX can be different on different systems. Make sure to configure
408         according to the setpci output.
409
410 Usage example
411 -------------
412
413 This section demonstrates how to launch **testpmd** with Mellanox ConnectX-3
414 devices managed by librte_pmd_mlx4.
415
416 #. Load the kernel modules:
417
418    .. code-block:: console
419
420       modprobe -a ib_uverbs mlx4_en mlx4_core mlx4_ib
421
422    Alternatively if MLNX_OFED is fully installed, the following script can
423    be run:
424
425    .. code-block:: console
426
427       /etc/init.d/openibd restart
428
429    .. note::
430
431       User space I/O kernel modules (uio and igb_uio) are not used and do
432       not have to be loaded.
433
434 #. Make sure Ethernet interfaces are in working order and linked to kernel
435    verbs. Related sysfs entries should be present:
436
437    .. code-block:: console
438
439       ls -d /sys/class/net/*/device/infiniband_verbs/uverbs* | cut -d / -f 5
440
441    Example output:
442
443    .. code-block:: console
444
445       eth2
446       eth3
447       eth4
448       eth5
449
450 #. Optionally, retrieve their PCI bus addresses for whitelisting:
451
452    .. code-block:: console
453
454       {
455           for intf in eth2 eth3 eth4 eth5;
456           do
457               (cd "/sys/class/net/${intf}/device/" && pwd -P);
458           done;
459       } |
460       sed -n 's,.*/\(.*\),-w \1,p'
461
462    Example output:
463
464    .. code-block:: console
465
466       -w 0000:83:00.0
467       -w 0000:83:00.0
468       -w 0000:84:00.0
469       -w 0000:84:00.0
470
471    .. note::
472
473       There are only two distinct PCI bus addresses because the Mellanox
474       ConnectX-3 adapters installed on this system are dual port.
475
476 #. Request huge pages:
477
478    .. code-block:: console
479
480       echo 1024 > /sys/kernel/mm/hugepages/hugepages-2048kB/nr_hugepages/nr_hugepages
481
482 #. Start testpmd with basic parameters:
483
484    .. code-block:: console
485
486       testpmd -l 8-15 -n 4 -w 0000:83:00.0 -w 0000:84:00.0 -- --rxq=2 --txq=2 -i
487
488    Example output:
489
490    .. code-block:: console
491
492       [...]
493       EAL: PCI device 0000:83:00.0 on NUMA socket 1
494       EAL:   probe driver: 15b3:1007 librte_pmd_mlx4
495       PMD: librte_pmd_mlx4: PCI information matches, using device "mlx4_0" (VF: false)
496       PMD: librte_pmd_mlx4: 2 port(s) detected
497       PMD: librte_pmd_mlx4: port 1 MAC address is 00:02:c9:b5:b7:50
498       PMD: librte_pmd_mlx4: port 2 MAC address is 00:02:c9:b5:b7:51
499       EAL: PCI device 0000:84:00.0 on NUMA socket 1
500       EAL:   probe driver: 15b3:1007 librte_pmd_mlx4
501       PMD: librte_pmd_mlx4: PCI information matches, using device "mlx4_1" (VF: false)
502       PMD: librte_pmd_mlx4: 2 port(s) detected
503       PMD: librte_pmd_mlx4: port 1 MAC address is 00:02:c9:b5:ba:b0
504       PMD: librte_pmd_mlx4: port 2 MAC address is 00:02:c9:b5:ba:b1
505       Interactive-mode selected
506       Configuring Port 0 (socket 0)
507       PMD: librte_pmd_mlx4: 0x867d60: TX queues number update: 0 -> 2
508       PMD: librte_pmd_mlx4: 0x867d60: RX queues number update: 0 -> 2
509       Port 0: 00:02:C9:B5:B7:50
510       Configuring Port 1 (socket 0)
511       PMD: librte_pmd_mlx4: 0x867da0: TX queues number update: 0 -> 2
512       PMD: librte_pmd_mlx4: 0x867da0: RX queues number update: 0 -> 2
513       Port 1: 00:02:C9:B5:B7:51
514       Configuring Port 2 (socket 0)
515       PMD: librte_pmd_mlx4: 0x867de0: TX queues number update: 0 -> 2
516       PMD: librte_pmd_mlx4: 0x867de0: RX queues number update: 0 -> 2
517       Port 2: 00:02:C9:B5:BA:B0
518       Configuring Port 3 (socket 0)
519       PMD: librte_pmd_mlx4: 0x867e20: TX queues number update: 0 -> 2
520       PMD: librte_pmd_mlx4: 0x867e20: RX queues number update: 0 -> 2
521       Port 3: 00:02:C9:B5:BA:B1
522       Checking link statuses...
523       Port 0 Link Up - speed 10000 Mbps - full-duplex
524       Port 1 Link Up - speed 40000 Mbps - full-duplex
525       Port 2 Link Up - speed 10000 Mbps - full-duplex
526       Port 3 Link Up - speed 40000 Mbps - full-duplex
527       Done
528       testpmd>