net/mlx5: make meter action thread safe
authorSuanming Mou <suanmingm@nvidia.com>
Wed, 28 Oct 2020 09:33:26 +0000 (17:33 +0800)
committerFerruh Yigit <ferruh.yigit@intel.com>
Tue, 3 Nov 2020 22:35:04 +0000 (23:35 +0100)
This commit adds the spinlock for the meter action to make it be thread
safe. Atomic reference counter in all is not enough as the meter action
should be created synchronized with reference counter increment. With
only atomic reference counter, even the counter is increased, the action
may still not be created.

Signed-off-by: Suanming Mou <suanmingm@nvidia.com>
Acked-by: Matan Azrad <matan@nvidia.com>
drivers/net/mlx5/mlx5_flow.h
drivers/net/mlx5/mlx5_flow_meter.c

index 6cac3ab..cb5b77f 100644 (file)
@@ -845,6 +845,8 @@ struct mlx5_flow_meter {
        struct mlx5_flow_meter_profile *profile;
        /**< Meter profile parameters. */
 
+       rte_spinlock_t sl; /**< Meter action spinlock. */
+
        /** Policer actions (per meter output color). */
        enum rte_mtr_policer_action action[RTE_COLORS];
 
index b36bc7b..03a5e79 100644 (file)
@@ -679,6 +679,7 @@ mlx5_flow_meter_create(struct rte_eth_dev *dev, uint32_t meter_id,
        fm->shared = !!shared;
        fm->policer_stats.stats_mask = params->stats_mask;
        fm->profile->ref_cnt++;
+       rte_spinlock_init(&fm->sl);
        return 0;
 error:
        mlx5_flow_destroy_policer_rules(dev, fm, &attr);
@@ -1167,49 +1168,49 @@ mlx5_flow_meter_attach(struct mlx5_priv *priv, uint32_t meter_id,
                       struct rte_flow_error *error)
 {
        struct mlx5_flow_meter *fm;
+       int ret = 0;
 
        fm = mlx5_flow_meter_find(priv, meter_id);
        if (fm == NULL) {
                rte_flow_error_set(error, ENOENT,
                                   RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
                                   "Meter object id not valid");
-               goto error;
-       }
-       if (!fm->shared && fm->ref_cnt) {
-               DRV_LOG(ERR, "Cannot share a non-shared meter.");
-               rte_flow_error_set(error, EINVAL,
-                                 RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
-                                 "Meter can't be shared");
-               goto error;
+               return fm;
        }
-       if (!fm->ref_cnt++) {
-               MLX5_ASSERT(!fm->mfts->meter_action);
+       rte_spinlock_lock(&fm->sl);
+       if (fm->mfts->meter_action) {
+               if (fm->shared &&
+                   attr->transfer == fm->transfer &&
+                   attr->ingress == fm->ingress &&
+                   attr->egress == fm->egress)
+                       fm->ref_cnt++;
+               else
+                       ret = -1;
+       } else {
                fm->ingress = attr->ingress;
                fm->egress = attr->egress;
                fm->transfer = attr->transfer;
+                fm->ref_cnt = 1;
                /* This also creates the meter object. */
                fm->mfts->meter_action = mlx5_flow_meter_action_create(priv,
                                                                       fm);
-               if (!fm->mfts->meter_action)
-                       goto error_detach;
-       } else {
-               MLX5_ASSERT(fm->mfts->meter_action);
-               if (attr->transfer != fm->transfer ||
-                   attr->ingress != fm->ingress ||
-                   attr->egress != fm->egress) {
-                       DRV_LOG(ERR, "meter I/O attributes do not "
-                               "match flow I/O attributes.");
-                       goto error_detach;
+               if (!fm->mfts->meter_action) {
+                       fm->ref_cnt = 0;
+                       fm->ingress = 0;
+                       fm->egress = 0;
+                       fm->transfer = 0;
+                       ret = -1;
+                       DRV_LOG(ERR, "Meter action create failed.");
                }
        }
-       return fm;
-error_detach:
-       mlx5_flow_meter_detach(fm);
-       rte_flow_error_set(error, EINVAL, RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
-                         fm->mfts->meter_action ? "Meter attr not match" :
-                         "Meter action create failed");
-error:
-       return NULL;
+       rte_spinlock_unlock(&fm->sl);
+       if (ret)
+               rte_flow_error_set(error, EINVAL,
+                                  RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
+                                  fm->mfts->meter_action ?
+                                  "Meter attr not match" :
+                                  "Meter action create failed");
+       return ret ? NULL : fm;
 }
 
 /**
@@ -1222,15 +1223,16 @@ void
 mlx5_flow_meter_detach(struct mlx5_flow_meter *fm)
 {
 #ifdef HAVE_MLX5_DR_CREATE_ACTION_FLOW_METER
+       rte_spinlock_lock(&fm->sl);
        MLX5_ASSERT(fm->ref_cnt);
-       if (--fm->ref_cnt)
-               return;
-       if (fm->mfts->meter_action)
+       if (--fm->ref_cnt == 0) {
                mlx5_glue->destroy_flow_action(fm->mfts->meter_action);
-       fm->mfts->meter_action = NULL;
-       fm->ingress = 0;
-       fm->egress = 0;
-       fm->transfer = 0;
+               fm->mfts->meter_action = NULL;
+               fm->ingress = 0;
+               fm->egress = 0;
+               fm->transfer = 0;
+       }
+       rte_spinlock_unlock(&fm->sl);
 #else
        (void)fm;
 #endif